Site Code | Site Name | Building Code | Building Name | Level | Room No. | Location | Item Description | Material Type | Sample Status Removed? | Friability Removed? | Disturbance Potential | Control Priority | Control Reccomendations/Record of Remedial Works | Asbestos Removed? |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FSFG | Fowlers Gap Field Station | Fowlers Gap New Waste Tip Area | G | - | - | On Ground Surface | Fibre Cement Sheet Debris | Positive - Removed | - | - | - | Item Removed: UNSW site personnel informed RiskTech that fibre cement debris removed. No fibre cement debris sighted by RiskTech during the inspection. | Yes | |
KENC | Kensington Campus | J12 | Newton | 3 | 313 | Under Carpet | Floor Covering | Adhesive attached to Cream Vinyl Tiles | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | Fowlers Gap Old Waste Tip Area | G | - | Eastern Section, Localised Areas (Note: Asbestos warning signage & barrier mesh & fencing present) | On Ground Surface | Fibre Cement Sheet Debris | Positive (Amosite & Chrysotile) | Non-Friable | Low | P3 | Demolition-'Restricted access to this area. 'Remedial works should be undertaken by a Class A/B Contractor within a planned control program. | Yes | |
KENC | Kensington Campus | F10 | Chemical Sciences | G | GQ1 | - | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item Removed: System upgraded. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | M | M10 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 1Q1 | Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item Removed: System upgraded. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 2Q1 | Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item Removed: System upgraded. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 4Q2 | Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item Removed: System upgraded. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 408 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | - | - | - | - | Item not present (information provided by Spotless). Item not identified during vinyl tiles removal works undertaken in June 2012 | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 7Q2 | Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item Removed: System upgraded. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 8Q2 | Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item Removed: System upgraded. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 8Q4 | Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item Removed: System upgraded. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 9Q1 | Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item Removed: System upgraded. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | 10Q1 | Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item Removed: System upgraded. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | LR | R3 | Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | System upgraded. Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | F25 | Samuels | LG-5 | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F25 | Samuels | LG-5 | - | Communications Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F25 | Samuels | LG-5 | - | Toilets Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | F8 | Law Building | B-03 | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | F8 | Law Building | B-03 | - | Throughout | Electrical Cupboards | No asbestos materials identified | - | - | - | - | - | N/A |
Kenc | Kensington Campus | F8 | Law Building | B-03 | - | Throughout | Comminications Cupboards | No asbestos materials identified | - | - | - | - | - | N/A |
Kenc | Kensington Campus | F8 | Law Building | B-03 | - | Throughout | Chiller Plant Room | No asbestos materials identified | - | - | - | - | - | N/A |
Kenc | Kensington Campus | F8 | Law Building | B-03 | - | Throughout | Mechanical Plant Room | No asbestos materials identified | - | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | Fowlers Gap Old Waste Tip Area | G | - | Western Section, Localised Areas (Note: fencing present) | On Ground Surface | Fibre Cement Sheet Debris | Assumed Positive | Non-Friable | Low | P3 | Demolition-'Restricted access to this area. 'Remedial works should be undertaken by a Class A/B Contractor within a planned control program. | Yes | |
FSFG | Fowlers Gap Field Station | Fowlers Gap Old Waste Tip Area | G | - | Western Section, Localised Areas (Note: fencing present) | Former Metal Plant Item | Woven Insulation | Assumed Positive | Friable | Low | P3 | Demolition-'Restricted access to this area. 'Remedial works should be undertaken by a Class A/B Contractor within a planned control program. | Yes | |
KENC | Kensington Campus | G19 | John Niland Scientia | LG-1 | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G19 | John Niland Scientia | LG-1 | - | Electrical Cupboards Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G19 | John Niland Scientia | LG | LGA04 | Lift Motor Room | Hydraulic Lift | No asbestos materials identified | - | - | - | - | - | N/A |
KENC | Kensington Campus | G19 | John Niland Scientia | LG | LG14B | Lift Motor Room | Hydraulic Lift | No asbestos materials identified | - | - | - | - | - | N/A |
KENC | Kensington Campus | G19 | John Niland Scientia | LG-1 | - | Conference Rooms, Auditoriums and Amenities Areas | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G19 | John Niland Scientia | LG-1 | - | External Façade | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | Fowlers Gap New Waste Tip Area | G | - | - | No asbestos materials identified | - | Negative | - | - | - | - | N/A | |
Kenc | Kensington Campus | G25CP | Botany Street External Carpark | G | - | Exterior Throughout including Roadways, Gardens, Footpaths | No asbestos materials were identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B10 | University Village | G | - | Exterior, Entrance Areas | Awning | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G6 | Blockhouse | - | R1 | Lift Motor Room | Hydraulic Lift | No asbestos materials identified | - | - | - | - | - | N/A |
KENC | Kensington Campus | G6 | Blockhouse | - | R1 | Lift Motor Room | Lift Controller Cabinet | No asbestos materials identified | - | - | - | - | - | N/A |
KENC | Kensington Campus | H13 | The Red Centre | B-6 | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H13 | The Red Centre | B-6 | - | Electrical Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H13 | The Red Centre | B-6 | - | Communicationsl Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H13 | The Red Centre | B-6 | - | Plant Rooms | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LGQ4 | Fire Exit | Fire Door (tagged Bismac 199_) | Core Insulation | - | - | - | - | Item removed (fire doors tagged Bismac 199_) - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | G | GQ2 | Electrical Cupboard | Electrical Switch Board | Electrical Backing Board | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | G | GQ2 | Fire Exit, Adjacent GQ7 | Fire Door | Core Insulation | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | G | GQ5 | Fire Exit | Fire Door | Core Insulation | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | G | GQ6 | Fire Exit | Fire Door | Core Insulation | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 1Q1 | Electrical Cupboard | Electrical Switch Board | Electrical Backing Board | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 1Q3 | Fire Exit | Fire Door | Core Insulation | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 1Q4 | Fire Exit | Fire Door | Core Insulation | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 2Q1 | Electrical Cupboard | Electrical Switch Board | Electrical Backing Board | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 2Q2 | Fire Exit | Fire Door | Core Insulation | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 2Q3 | Fire Exit | Fire Door | Core Insulation | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 3Q1 | Electrical Cupboard | Electrical Switch Board | Electrical Backing Board | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 3Q2 | Fire Exit | Fire Door | Core Insulation | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 3Q3 | Fire Exit | Fire Door | Core Insulation | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 4Q1 | Electrical Cupboard | Electrical Switch Board | Electrical Backing Board | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 4Q2 | Fire Exit | Fire Door | Core Insulation | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 4Q3 | Fire Exit | Fire Door | Core Insulation | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 5Q1 | Electrical Cupboard | Electrical Switch Board | Electrical Backing Board | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 5Q2 | Fire Exit | Fire Door | Core Insulation | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 5Q3 | Fire Exit | Fire Door | Core Insulation | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 6Q1 | Electrical Cupboard | Electrical Switch Board | Electrical Backing Board | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 6Q2 | Fire Exit | Fire Door | Core Insulation | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 6Q3 | Fire Exit | Fire Door | Core Insulation | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 7Q1 | Electrical Cupboard | Electrical Switch Board | Electrical Backing Board | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 7Q2 | Fire Exit | Fire Door | Core Insulation | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 7Q3 | Fire Exit | Fire Door | Core Insulation | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | R1 | Plant Room | Fire Door | Core Insulation | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | B10 | University Village | G | - | Exterior, Northern Elevation | Balcony Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B10 | University Village | LG-7 | - | Throughout | No asbestos materials were identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B10 | University Village | LG-7 | - | Within Electrical Cabinets Electrical Backing Boards | No asbestos materials were identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B10 | University Village | LG-7 | - | Throughout Communications Cupboards | No asbestos materials were identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B10 | University Village | LG-7 | - | Fire Stairs and Entrance To Accommodation Areas Throughout | Fire Doors (Tagged 'Icon, 2009') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | B10B | Campus Village Café | G | G01 | Exterior, South Side | Wall Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | B10B | Campus Village Café | G | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B12A | Building 12A | G | G02 | North Side, Adjacent East Entrance | Switch Board | Electrical Backing Board | Removed -Positive (Chrysotile) | - | - | - | Item removed. No removal or clearance documentation available. | Yes |
KENC | Kensington Campus | B12A | Building 12A | G | - | Exterior, Roof | Roof Covering | Membrane | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B12A | Building 12A | G | G02 | West Entrance | Fire Doors (tagged 'Robson Doors, 202-') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B12A | Building 12A | G | G02 | South & East Entrances | Fire Doors (tagged 'Wormald, 201-') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B12A | Building 12A | G | G02 | Central, Main Switchgear | Within Electrical Cabinets | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B12A | Building 12A | G | G01 & G02 | Below Ground Service Trench (beneath metal cover plates) | Conduits | Moulded Fibre Cement Pipes | Suspected Positive | Non-friable | Low | P4 | Further investigation should be undertaken to confirm presence and extent of asbestos materials in the service trences prior to demolition or refurbishment works. | No |
KENC | Kensington Campus | B12A | Building 12A | G | G01 | No access (Ausgrid controlled) | - | - | - | - | - | - | - | No |
KENC | Kensington Campus | H22A | Garbage Disposal Unit H22A | G | 01 | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 01 | F1Q01 F1Q02 F1Q03 F1Q04 | Throughout | Fire Hose Reel Cupboards | No asbestos materials identified | - | - | - | - | - | N/A |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 02 | F2Q01 F2Q02 F2Q03 F2Q04 | Throughout | Fire Hose Reel Cupboards | No asbestos materials identified | - | - | - | - | - | N/A |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 03 | F3Q01 F3Q02 F3Q03 F3Q04 | Throughout | Fire Hose Reel Cupboards | No asbestos materials identified | - | - | - | - | - | N/A |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 04 | F4Q01 F4Q02 F4Q03 F4Q04 | Throughout | Fire Hose Reel Cupboards | No asbestos materials identified | - | - | - | - | - | N/A |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 05 | F5Q01 F5Q02 F5Q03 F5Q04 | Throughout | Fire Hose Reel Cupboards | No asbestos materials identified | - | - | - | - | - | N/A |
KENE | Kensington Environs | BS32 | 32 Botany Street | G | - | Exterior, West Sunroom | Wall Cladding | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | BS32 | 32 Botany Street | G | 6 | - | Wall Lining | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | BS32 | 32 Botany Street | G | 7 | - | Ceiling | Fibre Cement Sheeting | Positive (Amosite, Chrysotile and Crocidolite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | - | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | J12 | Newton | G | G17 | On Floor | Duct Work Gasket | Insulation / Debris | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | J12 | Newton | 1 | 1Q4 | Door | Fire Door | Insulation Core | - | - | - | - | Item Removed: No removal documentation provided. Fire doors tagged 'GRG Fire Doors, 201_'). | Yes |
KENC | Kensington Campus | J12 | Newton | 1 | 1Q5 | Riser Entrance | Fire Door | Insulation Core | - | - | - | - | Item Removed: No removal documentation provided. Fire doors tagged 'TDS 201_'). | Yes |
KENC | Kensington Campus | J12 | Newton | 2 | 2Q5 | Riser Entrance | Fire Door | Insulation Core | - | - | - | - | Item removed (fire door tagged GRG Fire Door, 201_). No removal documentation provided | Yes |
KENC | Kensington Campus | J12 | Newton | 3 | 302A | Plant Room | Toilet Exhaust Duct Work & Fan Joints | Mastic Sealant | Removed - Positive (chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 3 May 2021. Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | J12 | Newton | 3 | 302A | Plant Room | Calorifier Door | Rope Seal | - | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | J12 | Newton | 3 | 3Q3 | Riser Entrance | Fire Door | Insulation Core | - | - | - | - | Item Removed: No removal documentation provided. Fire doors tagged 'TDS 201_'). | Yes |
KENC | Kensington Campus | J12 | Newton | R | RQ01 | Plant Room Entrance | Fire Door | Insulation Core | - | - | - | - | Item Removed: No removal documentation provided. Fire doors tagged 'TDS 201_'). | Yes |
KENC | Kensington Campus | J12 | Newton | R | R02 | Plant Room | Boiler Flue | Rope Seal | - | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate (Ref: C107266:J134461). Removed by ATS 8/8/2015 | Yes |
KENC | Kensington Campus | J12 | Newton | R | R02 | Plant Room | Boiler Pipe Work | Gaskets | - | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate (Ref: C107266:J134461). Removed by ATS 8/8/2015. | Yes |
KENC | Kensington Campus | J17 | Ainsworth Building | - | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K14 | Physics Theatre | LG | LG09A | - | Floor Covering | Vinyl Tiles | - | - | - | - | Item Removed 19/8/2017. Refer to RiskTech Asbestos Clearance Certificate dated 19/9/2017. | Yes |
KENC | Kensington Campus | K14 | Physics Theatre | G | G19-G21 | - | Floor Covering | Vinyl Tiles | - | - | - | - | Item Removed 21/2/2009. Refer to NAA Clearance Certificate SS0263:71828 dated 21/2/2009. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LG07 | - | Floor Covering | Vinyl Tiles | - | - | - | - | Item Removed 18/06/2007. Refer to NAA Clearance Certificate 54547 and Air Monitoring Report 54547.001. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LG08 | - | Ceiling | Fibre Cement Sheeting | - | - | - | - | Item Removed 18/06/2007. Refer to NAA Clearance Certificate 54547 and Air Monitoring Report 54547.001. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LG22 | - | Floor Covering | Vinyl Tiles (cream colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LG22A | - | Floor Covering | Vinyl Tiles (cream colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LG23 | - | Floor Covering | Vinyl Tiles (cream colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LG24 | - | Floor Covering | Vinyl Tiles (cream colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LG24A | - | Floor Covering | Vinyl Tiles (cream colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LG24B | - | Floor Covering | Vinyl Tiles (cream colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LG32 | Duct Riser, Redundant on Floor | Flue | Moulded Fibre Cement | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LG32 | Duct Riser | Debris | Pipe Lagging | - | - | - | - | Item Removed 1/3/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.006-008. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LG44 | - | Air Conditioning Ductwork Heater Bank | Insulation Board | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LG55 | Duct Riser | Ceiling | Fibre Cement Sheeting | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LGQ02 | Throughout | Ceiling | Fibre Cement Sheeting | - | - | - | - | Item Removed on 11/01/2014 by Ashton Demolition Pty Ltd. Refer to Airsafe Clearance Certificate (ref: 21909) dated January 2014. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LGQ12 | - | Floor Covering | Vinyl Tiles | - | - | - | - | Item Removed 01/01/2008. Refer to NAA Clearance Certificate 71182 and Air Monitoring Report 71182.001 | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G05 | - | Floor Covering | Vinyl Tiles | - | - | - | - | Item Removed 16/02/2008. Refer to NAA Clearance Certificate 55783 dated February 2008. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G06 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G16 | - | Ceiling | Fibre Cement Sheeting | - | - | - | - | Item Removed 1/2/2009. Refer to NAA Clearance Certificate 71828 and Air Monitoring Report 71828.001. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G31 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G32 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G36 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 14/5/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.009-010. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G36 | Under Stud Partition Walls | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 13/08/2013. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.011-012. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G37 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 13/08/2013. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.011-012. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G37 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 13/08/2013. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.011-012. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G37 | Under Stud Partition Walls | Floor Covering | Vinyl Tiles | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G38 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 13/08/2013. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.011-012. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G38 | Under Stud Partition Walls | Floor Covering | Vinyl Tiles | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G39 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | No | |
KENC | Kensington Campus | K15 | Old Main | G | G40 | Mineral Separator Plinth | Bench | Fibre Cement Sheeting | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G42 | - | Oven Door Seal | Rope | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G43 | - | Pipework Insulation | Lagging | - | - | - | - | Item Removed 13/03/2008. Refer to NAA Clearance Certificate 62928 and Air Monitoring Reports 62829.006-008. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G46A | - | Ceiling | Fibre Cement Sheeting | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G48 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G49A | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G49B | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G49B | Under Stud Partition Walls | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G50 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G50A | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G51 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 1/4/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.009-010. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G51A | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 1/4/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.009-010. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G51B | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G52 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 1/4/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.009-010. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G53 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 1/4/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.009-010. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G53A | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 1/4/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.009-010. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G54 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 1/4/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.009-010. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G55 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 1/4/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.009-010. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G56 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 1/4/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.009-010. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G60C | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G61 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 14/01/2011. Refer to NAA Clearance Certificate 77747 and Air Monitoring Report 77747.020. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G61A | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G61C | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 1/1/2011. Refer to NAA Clearance Certificate 77747 and Air Monitoring Report 77747.020. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G62 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G62B | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G62C | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G62D | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G62D1 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G62F | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G64B | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | GQ12 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 1/10/2008. Refer to NAA Clearance Certificate 68997 and Air Monitoring Reports 68997.001-002. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | GQ14 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 11/02/2008. Refer to NAA Clearance Certificate 55783 and Air Monitoring Reports 55783.007-008. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | GQ15 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 1/02/2008. Refer to NAA Clearance Certificate 55783 and Air Monitoring Reports 55783.007-008. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | GQ18 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 4/02/2008. Refer to NAA Clearance Certificate 55783 and Air Monitoring Reports 55783.003-004. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | GQ19 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 1/02/2009. Refer to NAA Clearance Certificate 71828 and Air Monitoring Reports 71828.001 | Yes |
KENC | Kensington Campus | K15 | Old Main | G | GQ20 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 1/02/2009. Refer to NAA Clearance Certificate 71828 and Air Monitoring Reports 71828.001 | Yes |
KENC | Kensington Campus | K15 | Old Main | G | GQ21 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 1/02/2009. Refer to NAA Clearance Certificate 71828 and Air Monitoring Reports 71828.001 | Yes |
KENC | Kensington Campus | K15 | Old Main | G | GQ22 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 1/02/2009. Refer to NAA Clearance Certificate 71828 and Air Monitoring Reports 71828.001 | Yes |
KENC | Kensington Campus | K15 | Old Main | G | GQ25 | - | Floor Covering | Vinyl Tiles (green colour) | - | - | - | - | Item Removed 11/02/2008. Refer to NAA Clearance Certificate 55783 and Air Monitoring Reports 55783.001-002 | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 101 | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 101 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 101 | - | Floor Covering | Vinyl Tiles (blue colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 101A | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 101B | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 101C | Throughout | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 101C1 | Throughout | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 101C2 | Throughout | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 102 | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 102A | Throughout | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 102B | Throughout | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 102C | Throughout | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 105 | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 106 | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 107 | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 108 | Throughout | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 113 | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 114 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 115 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 116 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 117 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 118 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 119 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 119A | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 120 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 121 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 122 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 129 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 130 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 131 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 132 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 133 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 133A | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. Room no longer present or relocated. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 135 | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. Room no longer present or relocated. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 137 | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. Room no longer present or relocated. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 137A | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. Room no longer present or relocated. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 137B | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. Room no longer present or relocated. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 137C | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. Room no longer present or relocated. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 137D | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. Room no longer present or relocated. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 138A | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. Room no longer present or relocated. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 138B | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. Room no longer present or relocated. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 138C | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. Room no longer present or relocated. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 138D | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. Room no longer present or relocated. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 139 | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 141A | Above Suspended Ceiling | Ceiling | Fibre Cement Sheeting | - | - | - | - | Item Removed 21/03/2015 by Pure Contracting. Refer to Greencap Clearance Certificate 132192 dated March 2015. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 144 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 144A | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 145 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed 21/11/2015. Refer to Airsafe Asbestos Clearance Certificate dated 23/11/2015 (report reference: 29259). | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 145A | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 146 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed 21/11/2015. Refer to Airsafe Asbestos Clearance Certificate dated 23/11/2015 (report reference: 29259). | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 148 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed 15/9/2009. Refer to Clearance Report (ref:SS0263:76754 dated 15 September 2009) | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 152 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed 15/2/2014. Refer to NAA Clearance Certificate J124675 dated 17/2/2014. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 153 | Duct Riser | Pipework Insulation | Lagging | - | - | - | - | Item Removed 1/3/2009. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.006-008. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 154 | - | Ceiling | Fibre Cement Sheeting | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 155 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed 29-31/1/2008. Refer to Clearance Certificate SU0013:62829 dated 2 January 2008 dated 31 January 2008 | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 156 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed 1/1/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.001-003. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 157 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 158 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item removed 1/1/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.001-003. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 158 | Floor Under Bench and Stud Partition Walls and Doors or North & Eastern Area | Floor Covering | Vinyl Tiles | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 158A | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 158B | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 159 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 159 | Under East Stud Partition Wall | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 159A | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed 1/1/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.001-003. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 159B | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed 1/1/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.001-003. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 159C | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed 1/1/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.001-003. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 159D | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed 1/1/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.001-003. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 159E | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed 1/1/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.001-003. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 159F | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed 1/1/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.001-003. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 163 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 164 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q10 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q12 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed 1/5/2010. Refer to NAA Clearance Certificate 77747 and Air Monitoring Report 77747.010. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q12 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed 1/5/2010. Refer to NAA Clearance Certificate 77747 and Air Monitoring Report 77747.010. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q15 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q16 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q17 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed 1/2/2009. Refer to NAA Clearance Certificate 71705 and Air Monitoring Report 71705.001. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q18 | - | Floor Covering | Vinyl Tiles (light grey colour) | - | Item removed 1/2/2008. Refer to NAA Clearance Certificate 55783 and Air Monitoring Reports 55783.005--006. | Yes | |||
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q19 | - | Floor Covering | Vinyl Tiles (grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 210C | Duct Riser | Pipework Insulation | Lagging | - | - | - | - | Item Removed 1/3/2008. Refer to NAA Clearance Certificate 62829 and Air Monitoring Reports 62829.006-008. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 224 | - | Floor Covering | Vinyl Tiles (green and cream colour) | - | - | - | - | Item Removed 21/6/2014. Refer to Greencap Clearance Certificate J127216 dated June 2014. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 228 | Beneath Partition Walls | Floor Covering | Vinyl Tiles | - | - | - | - | Item Removed 9/11/2013 by Aston Demolition. Refer to Airsafe Air Monitoring and Clearance Reports 21307 dated November 2013. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 228 | - | Floor Covering | Vinyl Tiles | - | - | - | - | Item Removed 19/2/2011. Refer to NAA Clearance Certificate SS0263:77747 dated 19/2/2011. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 229 | Beneath Partition Walls | Floor Covering | Vinyl Tiles | - | - | - | - | Item Removed 9/11/2013 by Aston Demolition. Refer to Airsafe Air Monitoring and Clearance Reports 21307 dated November 2013. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 229 | - | Floor Covering | Vinyl Tiles | - | - | - | - | Item Removed 19/2/2011. Refer to NAA Clearance Certificate SS0263:77747 dated 19/2/2011. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 230 | Beneath Partition Walls | Floor Covering | Vinyl Tiles | - | - | - | - | Item Removed 9/11/2013 by Aston Demolition. Refer to Airsafe Air Monitoring and Clearance Reports 21307 dated November 2013. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 230 | Entry Way | Floor Covering | Vinyl Tiles | - | - | - | - | Item Removed 9/11/2013 by Aston Demolition. Refer to Airsafe Air Monitoring and Clearance Reports 21307 dated November 2013. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 233 | Entry Way | Floor Covering | Vinyl Tiles | - | - | - | - | Item Removed 9/11/2013 by Aston Demolition. Refer to Airsafe Air Monitoring and Clearance Reports 21307 dated November 2013. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 234 | - | Floor Covering | Vinyl Tiles | - | - | - | - | Item Removed 9/11/2013 by Aston Demolition. Refer to Airsafe Air Monitoring and Clearance Reports 21307 dated November 2013. | Yes |
KENC | Kensington Campus | K15B | Substation 31 | G | - | Substation 31 | - | No asbestos materials identified | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 1 | 1Q04 | Fire Exit | Fire Door | Core Insulation | - | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 3 | 301 | West | Fire Door (Tagged 1972) | Core Insulation | - | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401 | West | Fire Door (No tag) | Core Insulation | - | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | L5 | Building L5 | - | - | Throughout Building | No asbestos materials identified or suspected | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | M15 | Rupert Myers | 01-05 | - | Male and Female Toilets | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | M15 | Rupert Myers | 01-05 | - | Accessible Toilets | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | M15 | Rupert Myers | 01-05 | - | Electrical and Mechanical Riser Cupboards | Inside Electrical Cabinets | Electrical Backing Boards | Suspected Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | M15 | Rupert Myers | 01-05 | - | Fire Hose Reel Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | BS32 | 32 Botany Street | G | 7 | - | Wall Lining | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | BS32 | 32 Botany Street | G | - | Exterior, East | Eaves | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
Kenc | Kensington Campus | N13 | Barker Apartments | - | - | Throughout Building | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | - | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 01 | 1Q4 | North | Electrical Switchboard | No asbestos materials identified | - | - | - | - | - | N/A |
KENE | Kensington Environs | BS32 | 32 Botany Street | G | - | Exterior, East and South-East | Gable | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENC | Kensington Campus | SST1D | Main Service Tunnel H13 Branch | G | - | Throughout | No asbestos materials Identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | SST1E | Main Service Tunnel G14 Mid Branch | G | - | Throughout | No asbestos materials Identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | SST1F | Main Service Tunnel G17 Branch | G | - | Throughout | No asbestos materials Identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | SST1B | Main Service Tunnel F13 Branch | G | - | Throughout | No asbestos materials Identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | SST1A | Main Service Tunnel F12 Branch | G | - | Throughout | No asbestos materials Identified | - | - | - | - | - | - | N/A |
KENE | Kensington Environs | BS22 | Tiggers Place | - | - | Throughout Building | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | BS26 | 26 Botany Street | G | - | - | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | HS30 | 30 High Street | G - 1 | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | HS32 | 32 High Street | G - 1 | - | Throughout | No asbestos items identified | - | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | BS32 | 32 Botany Street | G | - | Exterior | Gable Verge Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | WR45 | 45 Wansey Road | G - 1 | - | - | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV1 | Laboratory 1 | G | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
KENE | Kensington Environs | BS32 | 32 Botany Street | G | - | Exterior, South-East | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENE | Kensington Environs | BS32 | 32 Botany Street | G | - | Exterior, South-East | Within Electrical Cabinet | Electrical Backing Board | Suspected Positive - Removed | - | - | - | - | Yes |
MANV | Manly Vale | MV5 | Toilet Block | G | - | Throughout or Localised Area(s) (beneath cement, plaster or similar material) | Soffit Formwork (Underside of Concrete Roof Slab) | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Investigate the presence of asbestos containing fibre cement sheet formwork in other areas prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C19 | Garbage Disposal Unit | G | G01 | Exterior Throughout | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV7 | Laboratory 4 | G | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
MANV | Manly Vale | MV9 | Laboratory 3 | G | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
KENC | Kensington Campus | C19 | Garbage Disposal Unit | G | G01 | Exterior Throughout | Wall Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R14 | Institute of Languages | G - 2 | - | Ground Level to Level 3, Communications Riser Cupboard | Fire Doors Door tagged ' Australasian Fire Doors, 1999' | Core Insulation | Suspected Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R17 | Substation R17 | G | - | Substation 6958 | No asbestos materials identified | - | - | - | - | - | - | N/A |
RANC | Randwick Campus | R1a | Randwick R1a | G | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
RANC | Randwick Campus | R1b | Randwick R1b | G | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
RANC | Randwick Campus | R1c | Randwick R1c | G | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
RANC | Randwick Campus | R1d | Randwick R1d | G | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
RANC | Randwick Campus | R1e | Randwick R1e | G | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
KENC | Kensington Campus | C19 | Garbage Disposal Unit | G | G01 | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R4 | Randwick R4 | G | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
RANC | Randwick Campus | R6 | Randwick R6 | G | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
RANC | Randwick Campus | R8 | Switchroom Throughout | G | Switchroom | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
Kenc | Kensington Campus | C20 | Morven Brown External Car Park | G | - | Exterior Throughout including Roadways, Gardens, Footpaths | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 512 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | - | Exterior, UCA Roof Area | Floor Covering & Base of Wall (beneath concrete pavers) | Bituminous Membrane | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | - | Exterior, UCA Roof Area | Inside Electrical Cabinet | Electrical Backing Board | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 18 | - | Roof Above Level 18 | Roof (beneath concrete plinths supporting plant & equipment eg; antennas, vents & covers) | Bituminous Membrane | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | 03 | 301 | East | Window Frames (between frame & pane) | Mastic Sealant (black colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | 01 | 1Q4 | Fire Services Riser Cupboard & Hydraulic Duct Riser Cupboard | Ductwork Joint & Joins | Mastic Sealant (red/green colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | 01 | 114 | East | Window Frames (between frame & pane) | Mastic Sealant (black colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 01 | 141 | Squash Courts (B7), Service Riser | Ductwork Joins | Mastic Sealant | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | 4 | 405 | Plant Room, Entrance | Fire Door (tagged 'Masterbilt') | Core Insulation | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 24 November 2020. Note: New door installed - no tag. | Yes | ||||
KENC | Kensington Campus | C22 | Chancellery | LG | LG20 | Serive Tunnel off LG20, Southern End, Floor Slab | Conduit | Moulded Fibre Cement Pipes | Positive | Non-friable | Low | P3 | Seal exposed edges of the pipes under controlled conditions. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | LR | R1Q01 | Exterior, Throughout, Trafficable Roof Area | Floor Covering (below concrete pavers) | Bituminous Membrane | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | RL2 | R5 | Lift Motor Room | Lift Motors (installed 2005) | Brake Pads | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | RL2 | R2Q01 | Exterior | Roof Floor Covering | Bituminous Membrane | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | RL2 | R2Q02 | Exterior | Roof Floor Covering | Bituminous Membrane | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LGQ3 | Switch Room / Substation No.9, Adjacent Entrance - on Floor | Conduit | Moulded Fibre Cement | Positive | Non-friable | Low | P3 | Seal damaged edges. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G1 | Throughout (except majority of northern section - vinyl floor tiles present beneath walls and fixtures / benches) | Floor Covering | Vinyl Floor Tiles (beneath vinyl sheeting & screed - cement based levelling compound) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G13 | Throughout (except majority of northern section - vinyl floor tiles present beneath walls and fixtures / benches) | Floor Covering | Vinyl Floor Tiles (beneath carpet tiles) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G14 | East | Wall | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G23 | Throughout (except majority of northern section - vinyl floor tiles present beneath walls and fixtures / benches) | Floor Covering | Vinyl Floor Tiles (beneath carpet tiles) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | G | G8C | - | Conduit | Moulded Fibre Cement Pipe | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 109 | North, Behind New Window Panelling | Window Beading | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 1Q03 | East | Window Beading | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | 1Q25 | Service Tunnel, East End, South Wall | Conduits | Moulded Fibre Cement Pipes & Bituminous Material | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 11 | - | Roof Terrace, Covered Terrace & Roof Above SE Fire Stairs (11Q9) | Roof Covering & Parapet Walls (assumed beneath new membrane and/or concrete topping) | Bituminous Membrane | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | Roof | - | Roof | Roof Covering (beneath new membrane) | Bituminous Membrane Remnants | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 108 | Previously Room 139 | Window Beading | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | - | Exterior, Surround Doors | Expansion Joints | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | B - 03 | - | Exterior, Below Windows | Expansion Wall Joints | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 1Q1 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 1Q4 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 1Q1 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 1Q4 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 2Q1 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 2Q4 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 2Q1 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 2Q4 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 3Q1 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 3Q2 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 3Q4 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 3Q1 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 3Q2 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 3Q4 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 4Q1 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 4Q4 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 4Q1 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 4Q4 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 5Q1 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 5Q2 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 5Q4 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 5Q1 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 5Q2 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 5Q4 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 6Q1 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 6Q2 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 6Q4 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 6Q1 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 6Q2 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 6Q4 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 7Q1 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 7Q2 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 7Q4 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 7Q1 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 7Q2 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 7Q4 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 8Q1 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 8Q2 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 8Q4 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 8Q1 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 8Q2 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 8Q4 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 9Q1 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 9Q2 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 9Q4 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 9Q1 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 9Q2 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 9Q4 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | BS34 | 34 to 36 Botany Street | G | G20B | Toilet Cubicle | Partitioning | Compressed Fibre Cement Sheeting | Removed - Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 4 November 2019. | Yes |
KENE | Kensington Environs | BS34 | 34 to 36 Botany Street | G | G20B | - | Ceiling | Fibre Cement Sheeting | Removed - Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 4 November 2019. | Yes |
KENE | Kensington Environs | O14 | Kangas House | G | - | Exterior, Western Building, Outside Rooms 1 - 8F | Eaves | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | O14 | Kangas House | G | GQ01 | Exterior, Electrical Cupboard | Meter Board | Electrical Backing Board | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G17 | Electrical Engineering | G | GQ20 | Substation 7 | Floor Penetrations, Electrical Conduits | Moulded Fibre Cement | Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions prior to demolition or refurbishment. | No |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 02 | - | Exterior, Surrounding | Eaves | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | 1Q11 | - | Beneath Sheet Vinyl | Adhesive | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | G | G12 | - | Air Conditioning Ductwork Heater Bank | Insulation Board | Positive | Friable | Low | P3 | Not sighted during inspection. Heater bank may be present above suspended ceiling tiles. If present, remedial works should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | C22 | Chancellery | LG | LG35 | West Side, SW Corner | Conduit | Moulded Fibre Cement Pipes | Positive | Non-friable | Low | P3 | Seal exposed edges of the pipes under controlled conditions. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | LG | LGQ8 | Adjacent LG23, Risers (adjacent Electrical Switchboard Cupboard) | Conduit | Moulded Fibre Cement Pipe | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 03 | - | Exterior Throughout | Eaves | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | G | UGQ1 | Exterior, East Side, Main Entrance | Awning Ceiling | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 22 December 2016. | Yes |
KENC | Kensington Campus | C22 | Chancellery | G | G23 | - | Fire Door (tagged ' Metabilt, 1970') | Core Insulation | Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 10 April 2019. | Yes |
KENC | Kensington Campus | C22 | Chancellery | G | G20A | - | Fire Door | Core Insulation | Positive - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided. New appearance fire door tagged ' Bismac, 2014'. | Yes |
KENC | Kensington Campus | C22 | Chancellery | G | G21 | - | Fire Door | Core Insulation | Positive - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided. New appearance fire door tagged ' Bismac, 2014'. | Yes |
KENC | Kensington Campus | C22 | Chancellery | G | G22 | - | Fire Door (tagged 'Metabilt, 1970') | Core Insulation | Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 10 April 2019. | Yes |
KENC | Kensington Campus | K14 | Physics Theatre | LG | LG11C | - | Floor Covering | Vinyl Tiles (green colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | 802 | Throughout | Windows | Mastic Sealant | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | G | G24 | - | Fire Door | Core Insulation | Positive - Removed | - | - | - | Item Removed: Refer to Greencap Clearance Certificate dated 28 September 2015. New appearance fire door tagged ' TDF, 2015'. | Yes |
KENC | Kensington Campus | C22 | Chancellery | 01 | 142 | - | Fire Door | Core Insulation | Positive - Removed | - | - | - | Item Removed: Refer to Greencap Clearance Certificate dated 28 September 2015. New appearance fire door tagged ' TDF, 2015'. | Yes |
MANV | Manly Vale | MV4 | Workshop | G | G03 | - | Floor Covering | Vinyl Tiles (grey colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MANV | Manly Vale | MV3 | Laboratory 2 | G | - | Exterior, Eastern Office/Amenities Section | Eaves | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G01 | East | Wall | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 02 | 242 | - | Fire Door | Core Insulation | Positive - Removed | - | - | - | Item removed prior to Greencap 2014 inspection. No removal documentation provided. | Yes |
KENC | Kensington Campus | C22 | Chancellery | 03 | 310B | Plant Room | Fire Door | Core Insulation | Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 21 October 2017. | Yes |
KENC | Kensington Campus | C22 | Chancellery | LG | LG29 | East Side, Access to Service Tunnel | Fire Door (no tag) | Core Insulation | Positive (Amosite) | Non-friable | Low | P3 | Remedial works should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | C22 | Chancellery | B | B08 | - | Ductwork Flange Joints | Sealant Mastic | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | LG | LG12 | Former Lift Motor Room, South Wall | Board (labelled 'Zelemite') | Electrical Backing Board | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 01 | 113-126 | North Wing, Under Carpet | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | 01 | 146-159 | South Wing, Under Carpet | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | 01 | 1Q1 | North Wing, Under Carpet | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | LG | LG03-LG04 | Various Locations - | Ceiling | Decorative Coating (vermiculite) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | LG | LG29 | - | Ceiling | Decorative Coating (vermiculite) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | LG | LG29A | - | Ceiling | Decorative Coating (vermiculite) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | LG | LG29B | - | Ceiling | Decorative Coating (vermiculite) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | LG | LG29C | - | Ceiling | Decorative Coating (vermiculite) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | G | G01-G38 | - | Ceiling | Decorative Coating (vermiculite) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | G | GQ1-GQ15 | Throughout Ceiling | Sprayed Insulation | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | 02 | 201-257 | - | Ceiling | Decorative Coating (vermiculite) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | 02 | 2Q1-2Q11 | - | Ceiling | Decorative Coating (vermiculite) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | 03 | 301-310 | Roof Space, Throughout Ceiling Beams | Sprayed Insulation | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | 03 | 3Q1-3Q6 | Throughout Ceiling Beams | Sprayed Insulation | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | LG | LGQ8 | - | Ceiling | Decorative Coating (vermiculite) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | B | B08A | - | Ductwork Flange Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | LG | LG15B | - | Ductwork Flange Joins (old ductwork only) | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 6 | 6Q05 | Cleaners Cupboard | On Floor | Vinyl Floor Tile Debris | Positive | Non-friable | Low | P3 | Remove under controlled conditions by a Class A/B contractor as part of a planned program of works or prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 1Q02 | Under Carpet | Floor Covering | Vinyl Floor Tiles | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q03 | Cleaners Cupboard | Floor Covering | Vinyl Tiles | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 4Q06 | Under Carpet | Floor Covering | Vinyl Tiles | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 4Q08 | Cleaners Cupboard | Floor Covering | Vinyl Tiles | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 5Q01 | Under Carpet | Floor Covering | Vinyl Floor Tiles | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K14 | Physics Theatre | 01 | - | Exterior, South Side | Infill Wall Panelling (Fascia) | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q18 | Corridor to Newtown Building | Floor Covering | Vinyl Tiles (beige colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment | No |
KENC | Kensington Campus | K15 | Old Main | 02 | - | Exterior, North, South & East | Eaves | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 2Q1 | Throughout | Floor Covering | Vinyl Tiles (Blue, Grey & White Colour) | Positive - removed | - | - | - | Item removed. Refer Risktech clearance cert dated Sept 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 2Q4 | Throughout | Floor Covering | Vinyl Tiles (Blue, Grey & White Colour) | Positive - removed | - | - | - | Item removed. Refer Risktech clearance cert dated Sept 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 3Q1 | Throughout | Floor Covering | Vinyl Tiles (Blue, Grey & White Colour) | Positive - removed | - | - | - | Item removed. Refer RiskTech clearance cert dated Sept 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 3Q4 | Throughout | Floor Covering | Vinyl Tiles (Blue, Grey & White Colour) | Positive - removed | - | - | - | Item removed. Refer RiskTech clearance cert dated Sept 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 4Q1 | Throughout | Floor Covering | Vinyl Tiles (Blue, Grey & White Colour) | Positive - removed | - | - | - | Item removed. Refer Risktech clearance cert dated 19 Aug 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 4Q4 | Throughout | Floor Covering | Vinyl Tiles (Blue, Grey & White Colour) | Positive - removed | - | - | - | Item removed. Refer Risktech clearance cert dated 19 Aug 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 5Q1 | Throughout | Floor Covering | Vinyl Tiles (Blue, Grey & White Colour) | Positive - removed | - | - | - | - | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 5Q4 | Throughout | Floor Covering | Vinyl Tiles (Blue, Grey & White Colour) | Positive - removed | - | - | - | - | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 1Q1 | Throughout | Floor Covering | Vinyl Tiles (Blue, Grey & White Colour) | Removed Positive | - | - | - | Item removed. Refer RiskTech clearance cert dated 9th Sept 23 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 1Q6 | Throughout | Floor Covering | Vinyl Tiles (Blue, Grey & White Colour) | Removed Positive | - | - | - | Item removed. Refer RiskTech clearance cert dated 9th Sept 23 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 206 | Throughout | Floor Covering | Vinyl Tiles (Light Green Colour) | Positive - removed | - | - | - | Item removed. Refer Risktech clearance cert dated Sept 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 301 | Throughout | Floor Covering | Vinyl Tiles (Grey & Aqua Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 408 | Throughout | Floor Covering | Vinyl Tiles (Blue & Black Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 601 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 601A | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 601B | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 603 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 604 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Removed | - | - | - | Item removed. Refer RiskTech Clearance cert dated 22nd November 2022 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 607 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 608 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 612 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 15 July 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 617 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - removed | - | - | - | Item removed. Refer RiskTech clearance cert dated Oct 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 6Q1 | Throughout | Floor Covering | Vinyl Tiles (Blue, Grey & White Colour) | Positive - removed | - | - | - | Item removed. Refer RiskTech clearance cert dated Oct 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 6Q4 | Throughout | Floor Covering | Vinyl Tiles (Blue, Grey & White Colour) | Positive - removed | - | - | - | Item removed. Refer RiskTech clearance cert dated Oct 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 7Q1 | Throughout | Floor Covering | Vinyl Tiles (Blue, Grey & White Colour) | Positive - removed | - | - | - | Item removed. Refer Risktech clearance cert dated Oct 23 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 7Q4 | Throughout | Floor Covering | Vinyl Tiles (Blue, Grey & White Colour) | Positive - removed | - | - | - | Item removed. Refer Risktech clearance cert dated Oct 23 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LGQ1 | Throughout | Floor Covering | Vinyl Tiles (Mustard & Aqua Colour) | Positive - removed | - | - | - | Item removed. Refer RiskTech clearance cert dated Dec 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LGQ2 | Throughout | Floor Covering | Vinyl Tiles (Mustard & Aqua Colour) | Positive - removed | - | - | - | Item removed. Refer RiskTech clearance cert dated Dec 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | G | GQ2 | Hallway Adjacent Lift Lobby | Floor Covering | Vinyl Tiles (Grey & Blue Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 709 | Throughout | Floor Covering | Vinyl Tiles (Light Green Colour) | Positive - removed | - | - | - | Item removed. Refer Risktech clearance cert dated Oct 23 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 401 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Grey Colour) | Positive - removed | - | - | - | Item removed. Refer Risktech clearance cert dated 05/08/2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 401A | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Grey Colour) | Positive - removed | - | - | - | Item removed. Refer Risktech clearance cert dated 05/08/2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 402 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Grey Colour) | Positive - removed | - | - | - | Item removed. Refer Risktech clearance cert dated 05/08/2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 404 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Grey Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 404A | Throughout (beneath new flooring) | Floor Covering | Vinyl Tiles (Grey Colour) | Positive - removed | - | - | - | Item removed. Refer RiskTech Clearance cert dated 30/05/2022 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 416 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Grey Colour) | Positive - removed | - | - | - | Item removed. Refer Risktech clearance cert dated 19 Aug 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 702 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Removed - Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 4 November 2019. Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 703 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 705 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Tiles removed | Refer Risktech Clearance Certificate dated 20210206 | Yes | |||
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 706 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 710 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 712 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - removed | - | - | - | Item removed. Refer Risktech clearance cert dated 15 July 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 715 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Removed - Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 4 November 2019. Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 716 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 717 | Beneath Partition Walls | Floor Covering | Vinyl Tiles (Blue Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 717A | Beneath Partition Walls | Floor Covering | Vinyl Tiles (Blue Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 717B | Beneath Partition Walls | Floor Covering | Vinyl Tiles (Blue Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 717C | Beneath Partition Walls | Floor Covering | Vinyl Tiles (Blue Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 718 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 719 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 720 | Throughout | Floor Covering | Vinyl Tiles (Grey Colour) | Positive - removed | - | - | - | Item removed. Refer Risktech clearance cert dated Oct 23 | Yes |
Kenc | Kensington Campus | G15 | Robert Webster Theatres | 01 | 191 | West, Interior & Exterior | Window Frames (Between Frame and Pane) | Mastic Sealant | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | LG | LG18 | - | Ductwork Flange Joins (old ductwork only) | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F22 | Bank | - | - | Exterior, South Side, SW Corner (Common Joint with Library Building F21) | Wall Expansion Joints | Mastic Sealant | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F22 | Bank | 01 | 104 | Australia Post - Store | Floor Covering | Vinyl Tiles (cream & green colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F22 | Bank | 2 | 210 | Formerly Room 208 | Ceiling Access Manhole Cover | Fibre Cement Sheeting | Removed: Positive | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F22 | Bank | 2 | 210 | Formerly Room 208, 208A & 208B | Floor Covering (suspected vinyl tiles beneath new sheet vinyl) | Vinyl Tiles (brown colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F22 | Bank | 2 | 211 | Formerly Room 210 & 211 | Floor Covering (suspected under new floor covering) | Vinyl Tiles (brown colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | B | - | North Side, Service Duct | Conduit | Moulded Fibre Cement Pipes | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G18 | Mid-South | Wall | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | 1 | 106 | Area Above Room 106, North and South | Wall Lining | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | 1 | 104 | Area Above Room 104 | Wall Lining | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | 03 | 3Q4 | South Electrical Cupboard (Sub-Board) | Wall Lining | Fibre Cement Sheeting | Removed: Positive | - | - | - | Item Removed. No removal or clearance documentation available. | Yes |
KENC | Kensington Campus | E4 | Squarehouse | 02 | East | Exterior Veranda | Window Frames (between frame and pane) | Mastic Sealant | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | 03 | 3Q7 | West Entry | Fire Door (no tag) | Core Insulation | Positive (chrysotile) | Friable | Low | P2 | Remove fire door by a Class A Contractor within a planned control program. Note: Localised delamination of timber skin at base of door | No |
Kenc | Kensington Campus | D9 | IO Myers Studio | G | G08A | East and North | Walls | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Removed under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | Yes |
Kenc | Kensington Campus | D9 | IO Myers Studio | G | G05 | Toilets, Central | Partition Wall | Compressed Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Removed under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | Yes |
Kenc | Kensington Campus | D9 | IO Myers Studio | G | G05 | North, East and South | Walls | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Removed under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | Yes |
CCS | Cliffbrook Campus | CC2 | Building CC2 | G | - | Exterior, surrounding | Eaves | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | LG | LG20 | Serive Tunnel off LG20 | Ductwork Flange Joins (old ductwork only) | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | LG | LG35 | - | Ductwork Flange Joins (old ductwork only) | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | G | G25 | Ceiling Space | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | G | G25 | Plumbling Duct off Toilets | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | LGQ3A | Wall Void | Conduits | Moulded Fibre Cement | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | LGQ11 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Positive | Non-friable | Low | P4 | Not sighted during RT2018 inspection. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG56 | Exterior | Window Sill Expansion Joint | Mastic Sealant | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ10 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ7 | Throughout | Wall Expansion Joint | Mastic Sealant | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q4 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q10 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q7 | Exterior | Window Beading (between frame and pane) | Mastic Sealant | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q7 | Throughout | Wall Expansion Joint | Mastic Sealant | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q11 | Stairwell | Fire Door (No Door Tag) | Core Insulation | Positive | Friable | Low | P3 | Remedial works should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q10 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q7 | Throughout | Wall Expansion Joint | Mastic Sealant | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q7 | Throughout | Wall Expansion Joint | Mastic Sealant | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q7 | Throughout | Window Beading (between frame and pane) | Mastic Sealant | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q7 | Throughout | Window Beading (between frame and pane) | Mastic Sealant | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q7 | Throughout | Window Beading (between frame and pane) | Mastic Sealant | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 338 | South | Window Beading (between frame and pane) | Mastic Sealant | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | G | G26 | Ceiling Space | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | G | G26 | Plumbling Duct off Toilets | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | LG | LGQ01 | Pool (B4), Perimeter Throughout | Pipework Sleeves | Moulded Fibre Cement | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | LG | LGQ01 | Pool (B4), Service Tunnel | Pipework & Collars | Moulded Fibre Cement Material | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | B21 | Repository | G | G01 | Perimeter & Throughout | Floor Expansion Joints | Mastic Sealant | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | AS14 | 14 Arthur Street | G | - | Exterior, South Section, South & East Sides | Wall Cladding | Fibre Cement Sheeting | Positive (chrysotile & amosite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS12 | 12 Arthur Street | G | - | Exterior, South and West | Wall | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS10 | 10 Arthur Street | G | - | Exterior, Eastern Side, Surrounding Door | Infill Panels | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS10 | 10 Arthur Street | G | G08 | - | Ceiling | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS10 | 10 Arthur Street | G | G07 | West | Wall | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS8 | 8 Arthur Street | G | - | Exterior, Garage, Surrounding | Eaves | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS8 | 8 Arthur Street | G | - | Ceiling Space | Upper Ceiling | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS8 | 8 Arthur Street | G | - | Corridor | Ceiling Access Panel | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | A27 | Golf House | G | - | Exterior, North, South & East | Eaves | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENC | Kensington Campus | C22 | Chancellery | G | G26A | Ceiling Space | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 01 | 146 | Ceiling Space | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 01 | 147 | Ceiling Space | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 01 | 147A | Ceiling Space | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 02 | 2Q14 | Ceiling Space | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 02 | 2Q15 | Ceiling Space | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 02 | 2Q16 | Ceiling Space | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | G | GQ5 | - | Fire Doors (tagged 'Wormald, 198-') | Core Insulation | Assumed Positive | Friable | Low | P3 | Undertake sampling of fire doors under controlled conditions. If positive, remedial works should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | C22 | Chancellery | G | GQ8 | - | Fire Doors (tagged 'Wormald, 198-') | Core Insulation | Assumed Positive | Friable | Low | P3 | Undertake sampling of fire doors under controlled conditions. If positive, remedial works should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | C22 | Chancellery | G | GQ9 | - | Fire Doors (tagged 'Wormald, 198-') | Core Insulation | Assumed Positive | Friable | Low | P3 | Undertake sampling of fire doors under controlled conditions. If positive, remedial works should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | C22 | Chancellery | 01 | 135 | - | Fire Doors (tagged 'Wormald, 198-') | Core Insulation | Assumed Positive | Friable | Low | P3 | Undertake sampling of fire doors under controlled conditions. If positive, remedial works should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | C22 | Chancellery | 01 | 136 | - | Fire Doors (tagged 'Wormald, 198-') | Core Insulation | Assumed Positive | Friable | Low | P3 | Undertake sampling of fire doors under controlled conditions. If positive, remedial works should be undertaken by a Class A Contractor within a planned control program. | No |
RANC | Randwick Campus | R1 | Randwick R1 | G | G28/ G29 | Canteen | Window Frames | Mastic Sealant | Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q13 | Storage Cupboards (Ducts) | Ceiling | Fibre Cement Sheeting | Positive | Non-friable | Low | P3 | Remedial works should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 209A | - | On Top of Blockwork Walls | Sealant Mastic | Removed -Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 210 | Throughout | Window Beading | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 304 | Duct off Room 304 | Packing Material | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q8 | - | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 604 | - | Window Beading | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 6Q3 | North & East | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q6 | North & East | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q1 | - | Window Beading | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 701 | - | Window Beading | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 7Q3 | North & East | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1024 | - | Window Beading | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 10Q3 | North & East | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 812A | - | Window Beading | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 8Q1 | North & East | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 901 | - | Window Beading | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 11Q2 | South & West | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 12Q2 | South & West | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 13Q2 | West & South | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1301 | - | Window Beading | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 14Q2 | West & South | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1517A | - | Window Beading | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 01 | 137 | - | Fire Doors (tagged 'Wormald, 198-') | Core Insulation | Assumed Positive | Friable | Low | P3 | Undertake sampling of fire doors under controlled conditions. If positive, remedial works should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | C22 | Chancellery | 01 | 1Q5 | - | Fire Doors (tagged 'Wormald, 198-') | Core Insulation | Assumed Positive | Friable | Low | P3 | Undertake sampling of fire doors under controlled conditions. If positive, remedial works should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | C22 | Chancellery | 02 | 2Q7 | - | Fire Doors (tagged 'Wormald, 198-') | Core Insulation | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 18th Sept 2023 | Yes |
KENC | Kensington Campus | C22 | Chancellery | 02 | 2Q9 | - | Fire Doors (tagged 'Wormald, 198-') | Core Insulation | Assumed Positive | Friable | Low | P3 | Undertake sampling of fire doors under controlled conditions. If positive, remedial works should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | C22 | Chancellery | 03 | 310A | Service Cupboard, Roof Space | Ceiling (Eaves) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | - | - | Exterior Throughout | Eaves | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 01 | M1Q03 | Plumbling Duct off Room 146 Toilets | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 01 | M1Q04 | Plumbling Duct off Room 147 Toilets | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 02 | 2Q14 | Plumbling Duct off Toilets | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 02 | 2Q15 | Plumbling Duct off Toilets | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 303 | Under Carpet | Floor Covering | Vinyl Floor Tiles | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | 10Q2A | Gas Storage Cupboard | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | 10Q2A | Gas Storage Cupboard | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | LR | R1 | Western End, Plant Room | Hot Water Pipework (steam header) | Gasket | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 204 | North, Behind New Window Panelling | Window Beading | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J12 | Newton | G | G14 | Room WG8, North, East & South | Wall Lining | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MANV | Manly Vale | MV4 | Workshop | G | G03 | - | Ceiling | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J12 | Newton | 1 | 102 | South Wall | Wall Lining | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J12 | Newton | G | G14 | Room WG8A, Internal & External | Wall Lining | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J12 | Newton | G | G14 | Mezzanine Area (Room GM8), North & East | Wall Lining | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 723 | - | Window Frames | Sealant Mastic | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | LG | LGQ08 | Redundant Chiller Plant Room | Chiller Units, Pipework Flange Joints | Gaskets | Removed -Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 23 December 2000. | Yes |
KENC | Kensington Campus | E4 | Squarehouse | 01 | - | Exterior | Window Frames (between frame & pane) | Mastic Sealant (grey colour) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
COFA | Paddington Campus | CFAE | Block E | G | - | Exterior, North and South Elevations | Pebble Stone Horizontal Wall Joints (between concrete columns & wall panel sections) | Pointing | Positive | Non-friable | Low | P4 | Maintain in current condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 02 | - | Exterior, East, Outside Room 210-219A | Balcony Floor Covering | Bituminous Membrane | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 15 | - | Exterior, Perimeter (access via door in NE Fire Stairs (15Q1) | Roof Covering (assumed beneath new membrane) | Bituminous Membrane | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 03 | 310B | Plant Room Entrance | Fire Door (no tag) | Core Insulation | Assumed Positive | Friable | Low | P3 | Undertake sampling of fire doors under controlled conditions. If positive, remedial works should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | C22 | Chancellery | LG | LG35 | West Side | Wall | Bituminous Membrane | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | LG | LG45 | - | Air Conditioning Ductwork Heater Bank | Insulation Board | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LG55 | Duct Riser | Bituminous Flue (redundant material) | Moulded Fibre Cement | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LG55 | Duct Riser | Bituminous Flue | Moulded Fibre Cement | Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K14 | Physics Theatre | LG | LG12 | - | Flue | Moulded Fibre Cement | Removed - Positive | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G34 | - | Floor Covering | Vinyl Tiles (green colour) | Positive (Removed) | - | - | - | Item Removed 10/2/2018. Refer to RiskTech Clearance Certificate dated 10/2/2018. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G57 | - | Floor Covering | Vinyl Tiles (green colour) | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G58 | - | Floor Covering | Vinyl Tiles (green colour) | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G59 | - | Floor Covering | Vinyl Tiles (green colour) | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G59A | - | Floor Covering | Vinyl Tiles (green colour) | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G59C | - | Floor Covering | Vinyl Tiles (green colour) | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G59D | - | Floor Covering | Vinyl Tiles (green colour) | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G59E | - | Floor Covering | Vinyl Tiles (green colour) | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G59F | - | Floor Covering | Vinyl Tiles (green colour) | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G59G | - | Floor Covering | Vinyl Tiles (green colour) | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G59H | - | Floor Covering | Vinyl Tiles (green colour) | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 236A | Ceiling Space, on Top of Ceiling | Bitumen Pipe Collar | Moulded Fibre Cement | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | 01 | Former Room 103 | Throughout | Flue | Moulded Fibre Cement | Positive - Removed | - | - | - | Item removed 22/03/2014. Refer to NAA Clearance Certificate C107946:J125290. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | 01 | Former Room 114A | Throughout | Flue | Moulded Fibre Cement | Positive - Removed | - | - | - | Item removed 22/03/2014. Refer to NAA Clearance Certificate C107946:J125290. | Yes |
Kenc | Kensington Campus | C24 | Clancy Auditorium | R | - | South-East Corner | Flue | Moulded Fibre Cement | Positive (Removed) | - | - | - | Item Removed 4/3/2009. Refer to NAA Clearance Certificate SS0263:72214 and Air Monitoring Report 71828.001-003. | Yes |
Kenc | Kensington Campus | C24 | Clancy Auditorium | R | - | - | Wall Cladding Joints | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item Removed 13/07/2013. Refer to Safe Work & Environments Clearance Report dated 15/07/2013 | Yes |
Kenc | Kensington Campus | C24 | Clancy Auditorium | R | - | - | Wall Cladding | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item Removed 13/07/2013. Refer to Safe Work & Environments Clearance Report dated 15/07/2013 | Yes |
KENC | Kensington Campus | C22 | Chancellery | LG | LG12 | Entrance | Fire Door (tagged ' Fire Research - Installed 198-') | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | 01 | 1Q1 | Stairwell | Fire Door | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG69-71, LG57A & LG58 | Above Ceiling Tiles | Ceiling | Vermiculite | Positive - Removed | - | - | - | Item not sighted during 2014 or 2018 inspection. Further investigation may be required prior to refurbishment works in this area. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | G | Former Rooms G05, G05B, G06B, G06D, G06H, G07, G09, G10, G19, G19B, GQ06, GQ13 | Throughout | Ceilings | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 6 | 622 | Under Carpet | Floor Covering | Vinyl Tiles | Positive - Removed | - | - | - | Item removed by Pure Contracting on 23/7/2016 - Naa Clearance Certifcate (Ref: C107859:J145884) | Yes |
KENC | Kensington Campus | K17 | Building K17 | 6 | 623 | Under Carpet | Floor Covering | Vinyl Tiles | Positive - Removed | - | - | - | Item removed by Pure Contracting on 23/7/2016 - Naa Clearance Certifcate (Ref: C107859:J145884) | Yes |
KENC | Kensington Campus | K17 | Building K17 | 6 | 624 | Under Carpet | Floor Covering | Vinyl Tiles | Positive - Removed | - | - | - | Item removed by Pure Contracting on 23/7/2016 - Naa Clearance Certifcate (Ref: C107859:J145884) | Yes |
KENC | Kensington Campus | K17 | Building K17 | 6 | 625 | Under Carpet | Floor Covering | Vinyl Tiles | Positive - Removed | - | - | - | Item removed by Pure Contracting on 23/7/2016 - Naa Clearance Certifcate (Ref: C107859:J145884) | Yes |
RANC | Randwick Campus | R1 | Randwick R1 | G | G30 | Store Room, Entry | Fire Door | Core Insulation | Removed - Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 24 April 2019. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 18 | - | Roof Above Level 18 | Roof | Bituminous Membrane | Removed -Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 21 February 2019 | Yes |
KENC | Kensington Campus | C22 | Chancellery | G | UGQ1 | Exterior, East Side, Main Entrance | Soffit | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E4 | Squarehouse | R | RQ1 | West | Fire Door (no tag) | Core Insulation | Positive (Removed) | - | - | - | Item Removed by Pure Contracting on 23/01/2019. Refer to RiskTech Clearance and Air Monitoring Reports dated 23/01/2019. | Yes |
KENC | Kensington Campus | K14 | Physics Theatre | G | G29 | - | Bench Top | Compressed Fibre Cement Sheeting | Removed -Positive (chrysotile) | - | - | - | Item Removed 18/3/2017. Refer to RiskTech Clearance Certificate dated 18/3/2017. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 2Q8 | Fire Hydrant Cupboard | Floor Covering | Vinyl Tiles (brittle blue colour) | Positive (Removed) | - | - | - | Item Removed 29/4/2019 by Pure Contracting. Refer to RiskTech Clearance Certificate dated 29/4/2019. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 2Q7 | Electrical Cupboard | Floor Covering | Viny Tiles (green colour) | Positive (Removed) | - | - | - | Item Removed 29/4/2019 by Pure Contracting. Refer to RiskTech Clearance Certificate dated 29/4/2019. | Yes |
MANV | Manly Vale | MV3 | Laboratory 2 | B | - | Sub-Floor Space, Beneath Eastern Office/Amenities | Ground Surface, Debris | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item removed as part of the sampling process by RiskTech in July 2018. | Yes |
KENC | Kensington Campus | G27 | AGSM | 3 | 3Q3 | Fire Stairwell | Fire Door (tagged 'Masterbilt') | Core Insulation | Positive - Removed | - | - | - | Item Removed 2/6/2017 by ATS. Refer to RiskTech Clearance Certificate | Yes |
KENC | Kensington Campus | G27 | AGSM | 1 | 1Q3 | Fire Stairwell | Fire Door (tagged 'Masterbilt') | Core Insulation | Positive - Removed | - | - | - | Item Removed 2/6/2017 by ATS. Refer to RiskTech Clearance Certificate | Yes |
KENC | Kensington Campus | G27 | AGSM | 1 | 1Q2 | Fire Stairwell | Fire Door (tagged 'Masterbilt') | Core Insulation | Positive - Removed | - | - | - | Item Removed 2/6/2017 by ATS. Refer to RiskTech Clearance Certificate | Yes |
KENC | Kensington Campus | G27 | AGSM | G | GQ4 | Fire Stairwell | Fire Door (tagged 'Masterbilt') | Core Insulation | Positive - Removed | - | - | - | Item Removed 2/6/2017 by ATS. Refer to RiskTech Clearance Certificate | Yes |
KENC | Kensington Campus | G27 | AGSM | LG | LGQ3 | Fire Stairwell | Fire Door (no tag) | Core Insulation | Positive - Removed | - | - | - | Item Removed 2/6/2017 by ATS. Refer to RiskTech Clearance Certificate | Yes |
KENC | Kensington Campus | C22 | Chancellery | 01 | 132 | Under Carpet | Floor Covering | Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | G | - | Exterior, Façade | Façade Panel Expansion Joints | Mastic Sealant | Positive - Removed | - | - | - | Item removed by Pure Contracting Between November 2017 & March 2018 - Refer to RiskTech Clearance Certifcates | Yes |
KENC | Kensington Campus | K17 | Building K17 | 1 | - | Exterior, Façade | Façade Panel Expansion Joints | Mastic Sealant | Positive - Removed | - | - | - | Item removed by Pure Contracting Between November 2017 & March 2018 - Refer to RiskTech Clearance Certifcates | Yes |
KENC | Kensington Campus | K17 | Building K17 | 2 | - | Exterior, Façade | Façade Panel Expansion Joints | Mastic Sealant | Positive - Removed | - | - | - | Item removed by Pure Contracting Between November 2017 & March 2018 - Refer to RiskTech Clearance Certifcates | Yes |
KENC | Kensington Campus | K17 | Building K17 | 4 | - | Exterior, Façade | Façade Panel Expansion Joints | Mastic Sealant | Positive - Removed | - | - | - | Item removed by Pure Contracting Between November 2017 & March 2018 - Refer to RiskTech Clearance Certifcates | Yes |
KENC | Kensington Campus | K17 | Building K17 | 5 | - | Exterior, Façade | Façade Panel Expansion Joints | Mastic Sealant | Positive - Removed | - | - | - | Item removed by Pure Contracting Between November 2017 & March 2018 - Refer to RiskTech Clearance Certifcates | Yes |
KENC | Kensington Campus | K17 | Building K17 | 6 | - | Exterior, Façade | Façade Panel Expansion Joints | Mastic Sealant | Positive - Removed | - | - | - | Item removed by Pure Contracting Between November 2017 & March 2018 - Refer to RiskTech Clearance Certifcates | Yes |
KENC | Kensington Campus | K17 | Building K17 | 3 | - | Exterior, Façade | Façade Panel Expansion Joints | Mastic Sealant | Positive - Removed | - | - | - | Item removed by Pure Contracting Between November 2017 & March 2018 - Refer to RiskTech Clearance Certifcates | Yes |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | P09 | Pool (B4), Throughout | Air Conditioning Ductwork | Moulded Fibre Cement | Removed (Positive) | - | - | - | Item Removed: 8/5/2014. Refer to Airsafe Clearance Certificate (Job No. 23011). | Yes |
KENC | Kensington Campus | C22 | Chancellery | 01 | 1Q5 | Under Carpet | Floor Covering | Vinyl Tiles (light brown colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | B | B10 | - | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 18 | 1801 | North & East | Inside Electrical Cabinet (Note: new appearance cabinet) | Electrical Backing Board | Removed -Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | G6 | Blockhouse | G | G8C | - | Inside Electrical Cabinet | Electrical Backing Boards | Removed -Positive | - | - | - | Item Removed: 05-02-2014. No removal/clearance documentation was provided. New electrical cabinet present. | Yes |
KENC | Kensington Campus | G6 | Blockhouse | G | G10E | Electrical Room | Inside Electrical Cabinet | Electrical Backing Boards | Removed -Positive | - | - | - | Item Removed: 05-02-2014. No removal/clearance documentation was provided. New electrical cabinet present. | Yes |
Kenc | Kensington Campus | G15 | Robert Webster Theatres | 01 | 191B | South, Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | Positive (Removed) | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ4 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | C22 | Chancellery | B | BQ1 | - | Fire Door (tagged 'Cecon, 199_') | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG47 | Throughout | Floor Covering | Vinyl Floor Tiles (grey colour) | Positive - Removed | - | - | - | Removed 10-03-2014. Refer to NAA Clearance Certificate SS0263:77747 and Air Monitoring Report SS0263:77747.022. | Yes |
KENC | Kensington Campus | C20 | Morven Brown | LG | LGQ8 | Stairwell | Fire Door | Core Insulation | Positive - Removed | - | - | - | Removed 22-08-2018 by Pure Contracting. Refer to RiskTech Clearance and Air Monitoirng Report dated 22-08-2018. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LGQ6 | - | Floor Covering | Vinyl Floor Tiles (beige colour) | Positive - Removed | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 4 September 2008 (Ref: 68276). | Yes |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G1 | Northern Section Only | Floor Covering | Vinyl Floor Tiles (beneath vinyl sheeting) | Removed -Positive | - | - | - | Item Removed: Refer to RiskTech Asbestos Clearance Report dated 23 December 2017. | Yes |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G13 | Northern Section Only | Floor Covering | Vinyl Floor Tiles (beneath vinyl sheeting) | Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Report dated 23 December 2017. | Yes |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G14 | Southern Section | Floor Covering | Vinyl Floor Tiles (beneath vinyl sheeting) | Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Report dated 23 December 2017. | Yes |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G23 | Northern Section Only | Floor Covering | Vinyl Floor Tiles (beneath vinyl sheeting) | Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Report dated 23 December 2017. | Yes |
KENC | Kensington Campus | F21 | Library | 4 | 499A | Toilet | Ceiling | Fibre Cement Sheeting | Removed - Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 11 | 1199A | Toilet | Ceiling | Fibre Cement Sheeting | Removed - Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 9 | 999A | Toilet | Ceiling | Fibre Cement Sheeting | Removed - Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 10 | 1099A | Toilet | Ceiling | Fibre Cement Sheeting | Removed - Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 13 | 1399A | Toilet | Ceiling | Fibre Cement Sheeting | Removed - Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 14 | 1499A | Toilet | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 16 | 1604 | Lift Motor Room | Fire Door | Core Insulation | Removed - Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | C22 | Chancellery | B | BQ2 | - | Ceiling | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | G | GQ06 | Cleaners Cupboard | Floor Covering | Vinyl Tiles (brown colour) | Positive - Removed | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | G27 | AGSM | LG | LG01 | Riser Cupboard | Electrical Penetration | Insulation Material | Positive - Removed | - | - | - | Item Removed 20/3/2009. Refer to NAA Clearance Certificate SS0263:72606 | Yes |
KENC | Kensington Campus | G27 | AGSM | G | G02 | Riser Cupboard | Electrical Penetration | Insulation Material | Positive - Removed | - | - | - | Item Removed 20/3/2009. Refer to NAA Clearance Certificate SS0263:72606 | Yes |
KENC | Kensington Campus | G27 | AGSM | 1 | 112 | Riser Cupboard | Electrical Penetration | Insulation Material | Positive - Removed | - | - | - | Item Removed 20/3/2009. Refer to NAA Clearance Certificate SS0263:72606 | Yes |
KENC | Kensington Campus | G27 | AGSM | 2 | 234 | Riser Cupboard | Electrical Penetration | Insulation Material | Positive - Removed | - | - | - | Item Removed 20/3/2009. Refer to NAA Clearance Certificate SS0263:72606 | Yes |
KENC | Kensington Campus | G27 | AGSM | 3 | 321 | Riser Cupboard | Electrical Penetration | Insulation Material | Positive - Removed | - | - | - | Item Removed 20/3/2009. Refer to NAA Clearance Certificate SS0263:72606 | Yes |
DPFS | David Phillips Field | DP4 | Grounds Depot | G | G02 | Shower | Ceiling | Fibre Cement Sheeting | Positive - Removed | - | - | - | - | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 315, 316 & 316B | Previously 310 & 310A, Room 310 | Fume Cupboard | Millboard Lining | Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | ROQ2 | Lift Motor Room | Lift Controller Cabinet | Electrical Backing Board | Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | ROQ2 | Lift Motor Room | Lift Motors | Brake Pads | Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
MANV | Manly Vale | MV5 | Toilet Block | G | G01 | - | Boiler Pipe | Rope Lagging | Positive (removed) | - | - | - | No removal/clearance documentation was provided. | Yes |
MANV | Manly Vale | MV3 | Laboratory 2 | G | GQ2 | - | Floor Covering | Vinyl Tiles (light green colour) | Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
MANV | Manly Vale | MV3 | Laboratory 2 | B | Under G03-G09 | Sub-Floor Space | Ground Surface, Debris | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item removed 21/7/2012. Refer to NAA Clearance Certificate C107859:J111468 dated July 2012. | Yes |
KENC | Kensington Campus | C22 | Chancellery | B | BQ2 | Throughout | Floor Covering | Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | LG | LG18 | Entrance | Fire Door | Core Insulation | Negative | - | - | - | Item Removed: Prior to Greencap 2014 inspection. No removal documentation provided. | Yes |
MANV | Manly Vale | MV1 | Laboratory 1 | G | G01 | Water Research Service Pit | Pipes and Collars | Moulded Fibre Cement | Positive (Removed) | - | - | - | Item removed 21/09/2018 by Pure Contracting. Refer to RiskTech Clearance Certificate dated September 2018. | Yes |
MANV | Manly Vale | MV1 | Laboratory 1 | G | G03 | - | Floor Covering | Vinyl Tiles (grey colour) | Positive (Removed) | - | - | - | Item removed 21/08/2013 by Pure Contracting. Refer to NAA Clearance Certificate C107859:J121666-01. | Yes |
MANV | Manly Vale | MV1 | Laboratory 1 | G | G01 | South-West Wall | Within Electrical Cabinet | Electrical Backing Board | Positive (Removed) | - | - | - | Item removed. No removal documentation was provided. | Yes |
KENC | Kensington Campus | C22 | Chancellery | LG | LG17 | - | Ceiling | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | LG | LG18 | - | Floor Covering | Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | LG | LG17E | - | Floor Covering | Vinyl Tiles (black colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | LG | LG15 | Under Carpet | Floor Covering | Vinyl Tiles (brown colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | G | GQ8 | Under Carpet | Floor Covering | Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | G | G24 | Throughout | Floor Covering | Vinyl Tiles | Negative | - | - | - | N/A | |
KENC | Kensington Campus | C22 | Chancellery | 01 | 1Q5 | - | Ceiling | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 7 | 701 | - | Floor Covering | Vinyl Floor Tiles (brown colour) | Removed - Positive | - | - | - | Item Removed by Pure Contracting on 18/7/2015 - NAA Clearance Certificate (Ref: C107859:J134209) | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | - | Exterior, at LG12 | Flue | Moulded Fibre Cement | Positive (removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LG44 | - | Flue | Moulded Fibre Cement | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G43 | Riser | Flue | Moulded Fibre Cement | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G69A | Duct Riser | Flue | Moulded Fibre Cement | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G69A | Duct Riser | Pipework Insulation | Lagging | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 153 | Duct Riser | Flue | Moulded Fibre Cement | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 142 | - | Floor Covering | Vinyl Tiles (blue colour) | Positive (Removed) | - | - | - | Item Removed 21/11/2015. Refer to Airsafe Asbestos Clearance Certificate dated 23/11/2015 (report reference: 29259). | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 141A | Duct Riser | Flue | Moulded Fibre Cement | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 210C | Duct Riser | Flue | Moulded Fibre Cement | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 236A | Duct Riser | Flue | Moulded Fibre Cement | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 236A | Duct Riser | Pipework Insulation | Lagging | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 236A | Cleaner's Cupboard | Ceiling | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 141A | Duct Riser | Pipework Insulation | Lagging | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LGQ2 | Central, Hallway | Oven Door Seal | Rope Insulation | Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 315, 316 & 316B | Previously 310 & 310A, Throughout | Floor Covering | Vinyl Tiles (Blue, Grey & White Colour) | Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG6 | Throughout | Floor Covering | Vinyl Tiles (Aqua Colour) | Positive - Removed | - | - | - | Item removed 14/7/2014 by Pure Contracting - Airsafe Asbestos Clearance Certificate (Ref: 23811) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG6A | Throughout | Floor Covering | Vinyl Tiles (Aqua, Grey & White Colour) | Positive - Removed | - | - | - | Item removed 25/7/2010 by Cardinal Project Services - NAA Asbestos Clearance Certificate (Ref: SS0263:77747) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | G | G8 | Throughout | Floor Covering | Vinyl Tiles (Green Colour) | Positive - Removed | - | - | - | Item removed 8/11/2014 by Pure Contracting - Greencap-NAA Clearance Certificate (Ref: J107859:J130066) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 602 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 602A | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed 13/5/2009 by Cardinal Project Services - NAA Clearance Certificate (Ref: SU0013:738014) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 605 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 610 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed 25/8/2012 by Pure Contracting - NAA Clearance Certificate (Ref: C107946:J105057) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 611 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 611A | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 611B | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 613 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed 10/5/2014 by Pure Contracting - NAA Clearance Certificate (Ref: C107946:J126339) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 614 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed 26/9/2012 by Pure Contracting - NAA Clearance Certificate (Ref: C107946:J115471) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 615 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed 26/9/2012 by Pure Contracting - NAA Clearance Certificate (Ref: C107946:J115471) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 616 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG11 | Throughout | Floor Covering | Vinyl Tiles (Green Colour) | Positive - Removed | - | - | - | Item removed 1/12/2011 by Pure Contracting - NAA Clearance Certificate (Ref: SU0263:96374) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG3 | Throughout | Floor Covering | Vinyl Tiles (Mustard Colour) | Positive - Removed | - | - | - | Item removed 1/8/2013 by Pure Contracting - NAA Clearance Certificate (Ref: C107859:J121395) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | G | G6 | Throughout | Floor Covering | Vinyl Tiles (Green Colour) | Positive - Removed | - | - | - | Item removed 13/6/2015 by Pure Contracting - Greencap-NAA Clearance Certificate (Ref: J107859:J133139) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 501 | Throughout (previously rooms 501A, 501B, 501C, 501D, 501E & 501F | Floor Covering | Vinyl Tiles (Aqua, White & Light Green Colour) | Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 406A | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Grey Colour) | Positive - Removed | - | - | - | Item removed 18/9/2009 by Cardinal Project Services - NAA Clearance Certificate (Ref: SS0263:76754) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 406 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Grey Colour) | Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 701 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed 18/7/2015 by Pure Contracting - Greencap-NAA Clearance Certificate (Ref: C107859:J134209) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 704 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 707 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed 23/3/2019 by Pure Contracting - RiskTech Clearance Certifcate dated 25/3/2019 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 708 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed 25/8/2012 by Pure Contracting - NAA Clearance Certificate (Ref: C107946:J105057) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 713 | Throughout | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed - No removal documentation provided for review | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 717 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed 17/11/2018 by Pure Contracting - RiskTech Clearance Certifcate dated 17/11/2018 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 717A | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed 17/11/2018 by Pure Contracting - RiskTech Clearance Certifcate dated 17/11/2018 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 717B | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed 17/11/2018 by Pure Contracting - RiskTech Clearance Certifcate dated 17/11/2018 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 717C | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed 17/11/2018 by Pure Contracting - RiskTech Clearance Certifcate dated 17/11/2018 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 711 | Throughout | Floor Covering | Vinyl Tiles (Grey & Dark Blue Colour) | Positive - Removed | - | - | - | Item removed - No removal documentation provided for review | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 711A | Throughout | Floor Covering | Vinyl Tiles (Grey & Dark Blue Colour) | Positive - Removed | - | - | - | Item removed - No removal documentation provided for review | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | 802 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed 17/11/2018 by Pure Contracting - RiskTech Clearance Certifcate dated 17/11/2018 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | 802A | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Positive - Removed | - | - | - | Item removed 17/11/2018 by Pure Contracting - RiskTech Clearance Certifcate dated 17/11/2018 | Yes |
KENC | Kensington Campus | G27 | AGSM | LG | LGQ18 | (Previously Room LG08), Throughout | Ceiling | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | G27 | AGSM | LG | LGQ17 | (Previously Room LG09), Throughout | Ceiling | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | G27 | AGSM | 2 | 2Q3 | Fire Stairwell | Fire Door (tagged 'Masterbilt') | Core Insulation | Positive - Removed | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F22 | Bank | - | - | Exterior, West Side | Window Frames (between frame and pane) | Mastic Sealant | Removed - Positive | - | - | - | Item Removed: No removal/clearance documentation was provided. New appearance window framework - rubber seals. | Yes |
KENC | Kensington Campus | F13 | Science Theatre | LG | LG1 | Northern End, Eastern Side | Fire Door | Core Insulation | Positive - Removed | - | - | - | Item removed 27/2/2016 by ATS. Refer to Greencap Clearance Certificate dated 29/2/2016 (reference: C106266:J143335). | Yes |
KENC | Kensington Campus | F13 | Science Theatre | 1 | 1Q7 | Under Stair | Floor Lining | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed by Pure Contracting. Refer to RiskTech Clearance Certificate dated 3/6/2017. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | G | - | Exterior, Surrounding | Awning Ceiling | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | 01 | - | Exterior, Surrounding | Awning Ceiling | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | R | - | Under Air Conditioning Unit, covered by Loose Insulation Material | Floor Lining | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | 01 | Former Room 102 | Throughout | Flue | Moulded Fibre Cement | Positive - Removed | - | - | - | Item removed 5/6/2010. Refer to NAA Clearance Certificate SS0263:77747 dated June 2010. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | 01 | Former Room 102 | Ceiling Space | Pipework | Lagging | Positive - Removed | - | - | - | Item removed 5/6/2010. Refer to NAA Clearance Certificate SS0263:77747 dated June 2010. | Yes |
KENC | Kensington Campus | E4 | Squarehouse | G | G19 | Ceiling Space, Attached to Nail Heads | Debris | Fibre Cement Sheeting | Positive (Removed) | - | - | - | - | Yes |
KENC | Kensington Campus | D23 | Mathews Theatres | 01 | 150 | Plant Room, On Top of Air Handling Unit | Debris | Pipe Lagging | Removed - Positive | - | - | - | Item Removed 1/6/2007. Refer to NAA Clearance Certificate 57647. | Yes |
KENC | Kensington Campus | D23 | Mathews Theatres | 03 | 304 | - | Fire Door | Core Insulation | Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
Kenc | Kensington Campus | D16 | Goldstein Hall | 01 | 105 | - | Floor Covering | Vinyl Tiles (black colour) | Positive (Removed) | - | - | - | Item Removed 21/01/2011. Refer to NAA Clearance Report SS0263:77747. | Yes |
Kenc | Kensington Campus | D16 | Goldstein Hall | 02 | 201 | - | Wall | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item Removed. No removal documentation provided. | Yes |
Kenc | Kensington Campus | D16 | Goldstein Hall | 02 | 201 | - | Floor Covering | Vinyl Tiles | Positive (Removed) | - | - | - | Item Removed. No removal documentation provided. | Yes |
COFA | Paddington Campus | CFAC | Block C | 02 | C201 | Throughout | Floor Covering | Vinyl Tiles | Positive (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | G | CG11 | Throughout | Ceiling | Fibre Cement Sheeting | Positive (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | 01 | C1Q3 | Cupboard | Ceiling | Fibre Cement Sheeting | Positive (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | 02 | C2Q3 | Throughout | Floor Covering | Vinyl Tiles | Negative (Removed) | - | - | - | - | Yes |
KENC | Kensington Campus | F20 | Goodsell | 01 | 1Q6A | Plumbing Duct Adjacent Toilets | - | Insulation Debris | Removed - Positive | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 3 September 2007 (Ref: 59392). | Yes |
KENC | Kensington Campus | F20 | Goodsell | 01 | 1Q7 | Cleaners Room/Store Note: Previously Room 115A | Pipework | Insulation | Removed - Positive | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 3 September 2007 (Ref: 59392). | Yes |
KENC | Kensington Campus | F20 | Goodsell | 01 | 1Q6A | Plumbing Duct Adjacent Toilets | Pipework | Insulation | Removed - Positive | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 3 September 2007 (Ref: 59392). | Yes |
KENC | Kensington Campus | F20 | Goodsell | 02 | 217 | Cleaners Room/Store | Pipework | Insulation | Positive - Removed | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 3 September 2007 (Ref: 59392). | Yes |
KENC | Kensington Campus | C22 | Chancellery | 02 | 242 | - | Ceiling | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | 02 | 242 | Under Carpet | Floor Covering | Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | G | G15 | Cleaners Room/Store | Pipework | Insulation | Positive - Removed | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 3 September 2007 (Ref: 59392). | Yes |
KENC | Kensington Campus | F20 | Goodsell | 02 | 2Q3A | Plumbling Duct off Room 238 Toilets | Pipework | Insulation | Positive - Removed | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 3 September 2007 (Ref: 59392). | Yes |
KENC | Kensington Campus | C22 | Chancellery | 03 | 3Q2 | Under Carpet | Floor Covering | Vinyl Tiles (brown colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | LG | LGQ10 | Above Ceiling Tiles | Ceiling | Vermiculite | Positive - Removed | - | - | - | Item not sighted during 2014 inspection. Further investigation may be required prior to refurbishment works in this area. | Yes |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ11 | Stairwell | Fire Door | Core Insulation | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q12 | Ceiling Space | Ductwork Reheat Unit | Millboard Insulation | Positive - Removed | - | - | - | Item removed 30-06-2007. Refer to NAA Clearance Report SU0013:57917 | Yes |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q12 | Roof Space Access Door | Fire Door | Core Insulation | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q6 | Roof Space Access Door | Fire Door | Core Insulation | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q2 | Roof Space Access Door | Fire Door | Core Insulation | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENE | Kensington Environs | BS26 | 26 Botany Street | G | - | Exterior, Under Gate Column | Packer | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | G43 | Squash Courts (B7) | Partition Wall | Fibre Cement Sheeting | Removed (Positive) | - | - | - | Item Removed: No removal/clearance documentation provided. | Yes |
COFA | Paddington Campus | CFAC | Block C | B | CBQ5 | - | Awning ceiling | Fibre Cement Sheeting | Positive (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | G | - | Covered Walkway | Ceiling | Fibre Cement Sheeting | Positive (Removed) | - | - | - | - | Yes |
RANC | Randwick Campus | R1 | Randwick R1 | G | G34A/G35A | Female Toilets, South | Ceiling | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
RANC | Randwick Campus | R1 | Randwick R1 | G | - | Exterior, Windows | Infill Panels | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item removed by Uniport Australia Pty Ltd. Date of removal unknown. | Yes |
RANC | Randwick Campus | R1 | Randwick R1 | G | G28 | Adjacent Canteen Exit Door, West Side | Wall Panelling Surrounding Door | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG11 | Above Entrance | Duct Heater Banks x2 | Millboard | Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 730 | Service Duct Entry off Room 730 | Fire Door | Core Insulation | Removed - Positive | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate dated 16 March 2015 (Ref: J131981.002). Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 7Q3 | - | Fire Door | Core Insulation | Removed - Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 10Q3 | - | Fire Door | Core Insulation | Removed - Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 838 | - | Fire Door | Core Insulation | Removed - Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 837 | Service Duct Entry | Fire Door | Core Insulation | Removed - Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 18 | 1801 | - | Fire Door | Core Insulation | Removed -Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 18 | 1803 | - | Fire Door | Core Insulation | Removed -Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 931 | - | Fire Door | Core Insulation | Removed - Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 11Q2 | - | Fire Door | Core Insulation | Removed - Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 1428 | Service Duct Entry off Room 1428 | Fire Door | Core Insulation | Removed -Positive | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate dated 16 March 2015 (Ref: J131981.002). Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 1429 | - | Fire Door | Core Insulation | Removed -Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 13Q2 | - | Fire Door | Core Insulation | Removed -Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 13Q3 | - | Fire Door | Core Insulation | Removed -Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 14Q2 | - | Fire Door | Core Insulation | Removed -Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 17 | 1703 | - | Wall | Fibre Cement Sheeting | Removed -Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | C22 | Chancellery | 03 | 3Q3 | Roof Space, Throughout Ceiling Beams | Sprayed Insulation | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | 02 | 206 | - | Wall | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | 02 | 2Q3 | Exterior, Stairwell | Window Frames (between frame and pane) | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | 01 | - | Exterior, West Wing, North and South | Roof Covering | Bituminous Membrane | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | LG | LGQ1 | - | Floor Covering and Adhesive | Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | LG | LG35 | North | Fire Doors (tagged 'Bismac 2013'') | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | LG | LG29 LG29A LG29B LG29C | - | Floor Covering and Adhesive | Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | LG | LGQ8 | Under Carpet | Floor Covering | Vinyl Tiles and Adhesive (brown colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | G | G24 | - | Ceiling | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | LG | LGQ4 | Stairwell | Fire Door (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | LG | LGQ7 | Stairwell | Fire Door (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | LG | LGQ9 | Stairwell | Fire Door (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | LG | LGQ10 | Stairwell | Fire Door (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | G | G10 | - | Fire Door (tagged 'Bismac, 2014') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | G | G11 | West | Fire Door (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | G | G15 | West | Fire Door (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | G | GQ1 | Stairwell | Fire Door (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | G | GQ2 | Stairwell | Fire Door (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | G | GQ10 | Stairwell | Fire Doors (tagged ' Bismac, 2014') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | G | GQ13 | Stairwell | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | G | GQ14 | Stairwell | Fire Door | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Library | G | - | Biosciences North, | Awning Ceiling | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | C22 | Chancellery | 01 | 1Q2 | Stairwell | Fire Door (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 301 | Cleaners Cupboard | Floor Covering | Vinyl Tiles (dark brown colour) | Positive - Removed | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | C22 | Chancellery | 01 | 1Q7 | Stairwell | Fire Door (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 208A | - | Floor Covering | Vinyl Tiles & Adhesive (green colour) | Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
Kenc | Kensington Campus | G15 | Robert Webster Theatres | 02 | 290A | Lecture Theatre B, East Side, Projector Room, Ceiling Space, Above Ceiling | Ceiling | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item Removed by Pure Contracting on 10/6/2016. Refer to Greencap Clearance Certificate (C107859/J145185) dated 14/6/18. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 815 | - | Fire Door | Core Insulation | Removed - Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 8Q1 | - | Fire Door | Core Insulation | Removed - Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 8Q6 | - | Fire Door | Core Insulation | Removed - Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 17 | RQ01 | Western Roof Section, Near NW Corner, Surrounding Roof Opening to Duct Riser | Roof | Bituminous Membrane | Removed -Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 25 May 2019. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | G | Former Room G06 | Throughout Former Kitchen | Ceiling | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | G | Former Room G05 | Throughout | Ceiling | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | G | Former Room GQ06 | East Hallway | Floor Covering | Vinyl Tiles (brown colour) | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | G | Former Room G02B | Under Carpet Tiles | Floor Covering | Vinyl Tiles (blue and black colour) | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | R | - | Under Air Conditioning Unit, covered by Loose Insulation Material | Floor Lining | Fibre Cement Sheeting Debris | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | 01 | 1Q1, 1Q4, 1Q7 | Throughout, Beneath Purple Carpet | Floor Covering | Vinyl Tiles (blue and black colour) | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | C22 | Chancellery | 01 | 1Q9 | Stairwell | Fire Doors (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D9 | IO Myers Studio | G | G06 | East and South | Walls | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed by Pure Contracting on 19/03/2016. Refer to Greencap Clearance Certificate C107859:J143853 dated 21/03/16. | Yes |
FSFG | Fowlers Gap Field Station | FG4 | Fowlers Gap Cottage 5 | G | - | Exterior, Surrounding Cottage | Ground Surface | Fibre Cement Sheet Debris | Positive - Removed | - | - | - | Item Removed: UNSW site personnel informed RiskTech that fibre cement debris removed. RiskTech also removed fibre cement debris as part of the inspection process. | Yes |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | - | Exterior, Surrounding Cottage | On Ground Surface | Fibre Cement Sheet Debris | Positive - Removed | - | - | - | Item removed: UNSW site personnel informed RiskTech that fibre cement debris removed. RiskTech also removed fibre cement debris as part of the inspection process. | Yes |
FSFG | Fowlers Gap Field Station | FG5 | Fowlers Gap Cottage 2 | G | - | Exterior, Surrounding Cottage | On Ground Surface | Fibre Cement Sheet Debris | Positive - Removed | - | - | - | Item Removed: UNSW site personnel informed RiskTech that fibre cement debris removed. RiskTech also removed fibre cement debris as part of the inspection process. | Yes |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | - | Exterior, Surrounding Building | On Ground Surfaces | Fibre Cement Sheet Debris | Positive - Removed | - | - | - | Item removed. UNSW informed RiskTech that fibre cement debris removed. RiskTech also removed fibre cement debris as part of the inspection process. | Yes |
KENC | Kensington Campus | C22 | Chancellery | 02 | 239 | - | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | 02 | 239A | - | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
FSFG | Fowlers Gap Field Station | FG10 | Fowlers Gap Nissan Hut | G | - | Exterior, Surrounding Shed | On Ground Surface | Fibre Cement Sheet Debris | Positive - Removed | - | - | - | Demolished-Item Removed: UNSW site personnel informed RiskTech that fibre cement debris removed. RiskTech also removed fibre cement debris as part of the inspection process. | Yes |
FSFG | Fowlers Gap Field Station | FG10 | Fowlers Gap Nissan Hut | G | G01 | Storage Racks | Stored Pipes | Moulded Fibre Cement Pipes (x 2) | Positive - Removed | - | - | - | Demolished-Item Removed: UNSW site personnel informed RiskTech that fibre cement pipes removed. No stored asbestos containing fibre cement pipes sighted by RiskTech during the inspection. | Yes |
FSFG | Fowlers Gap Field Station | FG6 | Fowlers Gap Machinery Shed | G | - | Exterior, Surrounding Shed | On Ground Surface | Fibre Cement Sheet Debris | Positive - Removed | - | - | - | Item Removed: UNSW site personnel informed RiskTech that fibre cement debris removed. No fibre cement debris sighted by RiskTech during the inspection. | Yes |
KENC | Kensington Campus | C22 | Chancellery | 02 | 239B | - | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP4 | Grounds Depot | G | G02 | Shower | Cubicle Partitions | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed by Pure Contracting on 15/8/2017. Refer to RiskTech Clearance Report dated 15/08/2017. | Yes |
COFA | Paddington Campus | CFAC | Block C | SB | CSB04 | North | Floor Covering | Vinyl Tiles (grey colour) | Positive (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | SB | CSB04 | North | Floor Covering | Vinyl Tiles (cream colour) | Positive (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAA | Block A | G | AG14 | - | Flue | Bituminous Material | Positive (Removed) | - | - | - | Item removed prior to RiskTech inspection. No asbestos removal documentation was available for review. | Yes |
CCS | Cliffbrook Campus | CC2 | Building CC2 | G | - | Exterior, North | Communications Pit | Moulded Fibre Cement | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENE | Kensington Environs | BS30 | 30 Botany Street | 1 | 104 | Kitchen, Beneath Grey Vinyl | Floor Covering | Sheet Vinyl (beige colour) | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation provided. | Yes |
KENE | Kensington Environs | HS46 | 46 High Street | G | - | Switch Room, West Side | Electrical Cabinet | Electrical Backing Board | Removed -Positive | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F13 | Science Theatre | LG | LG1B | Boiler Room | Boiler, Pipe Flange Joint | Gasket | Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | G44 | Squash Courts (B7) | Floor Covering | Vinyl Tiles (orange/tan colour) | Removed (Positive) | - | - | - | Item Removed: 8/5/2014. Refer to Airsafe Clearance Certificate (Job No. 23011). | Yes |
KENE | Kensington Environs | BS34 | 34 to 36 Botany Street | G | G07 | Interior, Throughout | Flooring | Compressed Fibre Cement Sheeting | Removed (Positive) | - | - | - | Item Removed: 24-05-2014. Refer to Airsafe Inspection Report dated 24-05-2014 | Yes |
COFA | Paddington Campus | CFAA | Block A | B | AB3 | Plant Room | Air Conditioning Ductwork - Reheat Unit | Millboard Lining | Positive (Removed) | - | - | - | FM advised that this item had been removed prior to 27/07/2016. No asbestos removal documentation was available for review. | Yes |
COFA | Paddington Campus | CFAA | Block A | B | AB4 | Plant Room, West Side | Flue | Bituminous Material | Positive (Removed) | - | - | - | Item removed prior to RiskTech inspection. No asbestos removal documentation was available for review. | Yes |
COFA | Paddington Campus | CFAA | Block A | B | AB5 | Southern End | Flue | Bituminous Material | Positive (Removed) | - | - | - | Item removed prior to RiskTech inspection. No asbestos removal documentation was available for review. | Yes |
COFA | Paddington Campus | CFAA | Block A | B | AB2 | Exterior, Ceiling Penetration | Flue | Bituminous Material | Positive (Removed) | - | - | - | Item removed prior to RiskTech inspection. No asbestos removal documentation was available for review. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LG06 & LG07C | - | Floor Covering | Vinyl Tiles | Positive (Removed) | - | - | - | Item Removed 18/06/2007. Refer to NAA Clearance Certificate 54547 and Air Monitoring Report 54547.001. | Yes |
RANC | Randwick Campus | R1 | Randwick R1 | 01 | - | Roof Space Throughout | - | Fibre Cement Sheet Debris & Dust | Positive (Removed) | - | - | - | Item removed. Refer to RiskTech Clearance Certificate dated 10/6/2016. | Yes |
KENC | Kensington Campus | C22 | Chancellery | 02 | 2Q1 | Stairwell | Fire Doors (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAA | Block A | G | AG11A | Throughout | Wall | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item removed by Aston Demolition. Refer to Airsafe Clearance Report dated 3/10/2016. Note: Room number discrepancies. | Yes |
COFA | Paddington Campus | CFAA | Block A | G | AG11B | Throughout | Wall | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item removed by Aston Demolition. Refer to Airsafe Clearance Report dated 3/10/2016. Note: Room number discrepancies. | Yes |
COFA | Paddington Campus | CFAA | Block A | G | AG11A | Throughout | Ceiling | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item removed by Aston Demolition. Refer to Airsafe Clearance Report dated 3/10/2016. Note: Room number discrepancies. | Yes |
COFA | Paddington Campus | CFAA | Block A | G | AG11B | Throughout | Ceiling | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item removed by Aston Demolition. Refer to Airsafe Clearance Report dated 3/10/2016. Note: Room number discrepancies. | Yes |
KENC | Kensington Campus | C22 | Chancellery | 02 | 2Q3 | Stairwell | Fire Doors (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 623 | - | Fire Door | Core Insulation | Removed - Positive | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate dated 16 March 2015 (Ref: J131981.002). Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 624 | - | Fire Door | Core Insulation | Removed - Positive | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate dated 16 March 2015 (Ref: J131981.002). Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 103-107 | - | Bulkhead | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item removed 16/6/2007. Refer to NAA Clearance Report SU0013:57545 and Air Monitoring Reports 57545.001 & 002 | Yes |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 103-107 | - | Heater Bank | Millboard Insulation | Positive - Removed | - | - | - | Item removed 16/6/2007. Refer to NAA Clearance Report SU0013:57545 and Air Monitoring Reports 57545.001 & 002 | Yes |
Kenc | Kensington Campus | C6 | International House | G | G99 | Office - Ceiling Space | Hot Water Pipework | Insulation | Removed - Positive | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
KENC | Kensington Campus | G27 | AGSM | 1 | 110 | Communications Riser Cupboard | Fire Door (no tag) | Core Insulation | Removed - Positive (chrysotile & amosite) | - | - | - | Item Removed. No removal / clearance documentation available. | Yes |
KENC | Kensington Campus | F21 | Library | 3 | 322 | Electrical Room Adjacent Fire Stairs (3Q14) | On Soffit Surrounding Column | Insulation Residue & Bituminous Coating (adhesive) | Removed - 'Positive (chrysotile & amosite) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 25 May 2000. | Yes |
KENC | Kensington Campus | F12 | Dalton | G | - | Exterior of GQ2 | Window Frames (between frame and pane) | Mastic Sealant | Positive (chrysotile & amosite) | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LGQ2 | Substation No.9, Entrance | Fire Door - Double Doors (no tag) | Core Insulation | Removed - Positive (Chrysotile & Amosite) | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 3 December 2020. | Yes |
KENC | Kensington Campus | D23 | Mathews Theatres | 01 | 150 | North Entrance, Adjacent Room 1Q3 | Fire Door (tagged 'Metabilt, 1973') | Core Insulation | Removed -Positive (chrysotile & amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated. | Yes |
KENC | Kensington Campus | D23 | Mathews Theatres | 01 | 105 | Riser Entrance | Fire Door (tagged 'Metabilt, 1973') | Core Insulation | Removed -Positive (chrysotile & amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated. | Yes |
CCS | Cliffbrook Campus | CC1 | Cliffbrook House | G | - | Exterior, North-East | Communications Pit | Moulded Fibre Cement | Positive (Amosite & Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 02 | 2Q5 | Stairwell | Fire Doors (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 1 | 186A | Store - Riser | Access Panel | Fibre Cement Sheeting | Positive (Amosite & Chrysotile) - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 23rd December 2019 | Yes |
Kenc | Kensington Campus | C24 | Clancy Auditorium | LG | LG3 | Entrance | Fire Door (No Tag) | Core Insulation | Positive (chrysotile & amosite) | Friable | Low | P2 | Remedial works should be undertaken by a Class A Contractor within a planned control program. Note: Timber skin at base of door delaminating. | No |
Kenc | Kensington Campus | B21 | Repository | G | G01 | Exterior, Eastern Side, Surrounding Pipe Ends | Waterproof Membrane | Bituminous Membrane | Positive (chrysotile & amosite) | Non-friable | Low | P3 | Consideration should be given for the remediation (removal or sealing) of the membrane with an encapsulant / paint under controlled conditions by a Class A/B contractor. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 232 | Ceiling Space | Toilet Cistern | Moulded Fibre Cement | Positive (chrysotile & amosite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment | No |
KENC | Kensington Campus | C22 | Chancellery | 02 | 2Q10 | Stairwell | Fire Doors (tagged 'Fire Systems Engineering, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G16 | Stage Left | Flue | Moulded Fibre Cement Pipe | Removed: Positive (chrysotile & amosite) | - | - | - | Item Removed. Refer to Risktech Compliance Asbestos Clearance Certificate dated 26 August 2019. | Yes |
KENC | Kensington Campus | C22 | Chancellery | 02 | 2Q11 | Stairwell | Fire Doors (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | 03 | 3Q1 | Stairwell | Fire Doors (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | 03 | 3Q6 | Stairwell | Fire Doors (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D18 | Phillip Baxter College | G-7 | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D18 | Phillip Baxter College | G-7 | - | Throughout, Electrical Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D18 | Phillip Baxter College | G-7 | - | Throughout, Communications Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D18 | Phillip Baxter College | G-7 | - | Throughout, Fire Stairs, Services Cupboards, Accommodation Rooms | Fire Doors (tagged 'Exodus, 2013') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D18 | Phillip Baxter College | G-7 | - | Throughout, Kitchenettes and Cleaner's Rooms | Floor Covering | Sheet Vinyl | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D23 | Bio Sciences North | LG | ELGQ01 | Biolink, | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New fire door tagged 'Ikon Door - Manufactured 201-'). | Yes |
Kenc | Kensington Campus | D24 | Bio Sciences North | LG | ELGQ01A | Biolink, | Inside Electrical Distribution Cabinets | Electrical Backing Boards | Suspected Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New switchboard electrical cabinets). | Yes |
Kenc | Kensington Campus | D25 | Bio Sciences North | LG | ELGQ01A | Biolink, | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New fire door tagged 'Ikon Door - Manufactured 201-'). | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | GQ12 | Biolink, | Fire Door (tagged 'Inglis, 1990') | Insulation Core | - | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 255 | Biolink | Ceiling Tiles | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech Clearance cert dated 13/10/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G22 | Biolink, | Drainage Pipe (wrapped in black plastic sheeting) | Moulded Fibre Cement Pipe | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 139 | Biolink | Drainage Pipe | Moulded Fibre Cement Pipe | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 240 | Biolink | Drainage Pipe | Moulded Fibre Cement Pipe | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 254 | Biolink | Drainage Pipe | Moulded Fibre Cement Pipe | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 340 | Biolink | Drainage Pipe | Moulded Fibre Cement Pipe | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q7 | Biolink | Drainage Pipe | Moulded Fibre Cement Pipe (wrapped in black plastic sheeting) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 458 | Biolink | Drainage Pipe | Moulded Fibre Cement Pipe | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q7 | Biolink | Drainage Pipe | Moulded Fibre Cement Pipe (wrapped in black plastic sheeting) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q10 | - | Drainage Pipe | Moulded Fibre Cement Pipe (wrapped in black plastic sheeting) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | R01 | Plant Room | Drainage Pipe | Moulded Fibre Cement Pipe | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | GQ13 | Biolink | On Concrete Floor Slab (beneath floor covering) | Bituminous Adhesive | Positive - Removed | - | - | - | Item Removed: Refer to Risktech Clearance Certificate dated 10 September 2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 134 | Biolink | On Concrete Floor Slab (beneath floor covering) | Bituminous Adhesive | Removed - Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 28 September 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q12 | Biolink | On Concrete Floor Slab (beneath vinyl floor tiles) | Bituminous Adhesive | Removed -Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 30 October 2020 & 28 September 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 138 | Biolink | On Concrete Floor Slab (suspected beneath carpet & tiles) | Bituminous Adhesive | Removed -Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 28 September 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 138A | Biolink | On Concrete Floor Slab (suspected beneath carpet & tiles) | Adhesive | Positive | - | - | - | Item removed. Refer Risktech Clearance cert dated 28/09/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 143 | Biolink | On Concrete Floor Slab (suspected beneath floor linoleum) | Bituminous Adhesive | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 132A | Biolink | Fire Door | Insulation Core | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 23 March 2020. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 240 | Biolink, | Walls | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. (Note: No access at time of inspection - construction area). | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 340 | Biolink, | Walls | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. (Note: No access at time of inspection - construction area). | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG024 | Biolink, | Drainage Pipe (wrapped in black plastic sheeting) | Moulded Fibre Cement Pipe | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 254 | Biolink, | On Pipe | Loose Rpe Packing Insulation | Positive - Removed | - | - | - | Item Removed by RiskTech in 2017 (part of sampling process) | Yes |
FSFG | Fowlers Gap Field Station | FG22 | Fowlers Gap Greenhouse | G | - | Exterior, Approximately 50m East of Greenhouse | Protective Barriers | Moulded Fibre Cement Pipe Sections | Positive (Amosite & Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
Kenc | Kensington Campus | C6 | International House | Roof | - | Above Men's Toilet Riser | Flues (assumed present - no access on roof) | Compressed Bituminous Pipes | Positive (chrysotile & amosite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
FSW | Wellington Field Station | WFS1 | Wellington Field Station Cottage | G | 1 | Main Residence, Exterior, All Sides | Walls & Gables | Profiled Fibre Cement Sheeting | Positive (Amosite & Chrysotile) | Non-friable | Low | P3 | Repair/seal the localised damage areas to the wall sheeting under controlled conditions within a planned control program. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS4A | Wellington Field Station Cool Room | G | G01 | Throughout | Ceiling | Fibre Cement Sheeting | Positive (Amosite & Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSSL | Smiths Lake Field Station | SL4 | Smiths Lake Boat Shed | G | - | Sub-Floor Space | On Top of Brick Piers, Packing Material | Fibre Cement Sheeting | Positive (chrysotile & amosite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 565 | Between Room 565 & 565A | Partition Wall | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed: Refe to NAA Clearance Report (Ref: C107946:J105057) dated March 2012. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q12 | Biolink, Electrical Riser Cupboard | Floor Slab Penetrations | Packing Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to NAA Clearance Report C107859:J125585 dated March 2014. Material has been removed from accessible locations. | Yes |
KENC | Kensington Campus | F22 | Bank | 01 | - | Exterior, West, Covered Entry | Ceiling | Fibre Cement Sheeting | Positive (chrysotile & amosite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D14 | UNSW Hall | G | MBGQ02 | Riser adjacent Room BG94A | Flue | Bituminous Cement | Positive (Amosite & Chrysotile) | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | - | Exterior, All Sides | Walls | Profiled Fibre Cement Sheeting | Positive (Amosite & Chrysotile) | Non-friable | Low | P3 | Repair/seal the localised damage areas to the wall sheeting under controlled conditions within a planned control program. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | - | Far SW Corner Room, Toilet (former uncovered awning) | Ceiling | Fibre Cement Sheeting | Positive (Amosite & Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | G01 | NW Corner Room, | Ceiling | Fibre Cement Sheeting | Positive (Amosite & Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 2Q7 | Biolink, Communication Riser Cupboard | Floor Slab Penetrations | Packing Insulation | Removed -Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 13 October 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q6 | Biolink, Electrical Riser Cupboard | Floor Slab Penetrations | Packing Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to NAA Clearance Report C107859:J125585 dated March 2014. Material has been removed from accessible locations. | Yes |
FSH | Hay Field Station | HFS3 | Hay Field Station Machinery Shed | G | - | Approx. 20 Metres South East of Shed - Adjacent Scrap Metal Stockpile | Disused Pipe | Moulded Fibre Cement Material | Positive (Amosite & Chrysotile) | Non-friable | Low | P3 | Remove disused fibre cement pipe under controlled conditions within a planned control program. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG06 | Biolink, | Debris | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
FSFG | Fowlers Gap Field Station | FG1 | Fowlers Gap Solarch House | G | - | Exterior Throughout | Walls | Fibre Cement Sheeting (pebble mix finish) | Positive (Amosite & Chrysotile) | Non-friable | Low | P4 | Removed between 26/08/2024 to 31/08/2023 as per Asbestos Clearance Certificate dated 03/09/2024 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 138 | Biolink, West | Wall | Fibre Cement Sheeting | Removed -Positive (amosite & chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 28 September 2021. | Yes |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | - | Exterior, North | (pebble mix finish) | Moulded Fibre Cement Material | Positive (Amosite & Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | - | Exterior, All Sides | Walls | Profiled Fibre Cement Sheeting | Positive (Amosite & Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 01 | - | Exterior, East | Windows (between Metal Framework & Glass) | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | AS22 | 22 Arthur Street | G | - | Exterior, Main Residence, Surrounding | FG001-38 | Fibre Cement Sheeting | Positive (Amosite & Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS20 | 20 Arthur Street | G | - | Exterior, Garage | Positive | Corrugated Fibre Cement Sheeting | Positive (Amosite & Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS12 | 12 Arthur Street | G | - | Exterior, North | (chrysotile & | Fibre Cement Sheeting | Positive (Amosite & Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS10 | 10 Arthur Street | G | - | Exterior, West | amosite) | Moulded Fibre Cement | Positive (Amosite & Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS2 | 2 Arthur Street | G | - | Exterior, Rear, South, East and West | 1 & 2 ~250 m² Fair-Good Non-friable Low Low Yes P4 | Fibre Cement Sheeting | Positive (Amosite & Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS2 | 2 Arthur Street | G | - | Exterior, Garage, East and West | Gable | Fibre Cement Sheeting | Positive (Amosite & Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | HS34 | 34 High Street | 2 | 105 | Interior, Unit 3, Kitchen | Service Riser, Wall Lining | Fibre Cement Sheeting | Positive (Amosite & Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | HS34 | 34 High Street | 2 | 106 | Interior, Unit 4, Kitchen | Service Riser, Wall Lining | Fibre Cement Sheeting | Positive (Amosite & Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | HS34 | 34 High Street | 1 | G06 | Interior, Unit 1, Kitchen | Service Riser, Wall Lining | Fibre Cement Sheeting | Positive (Amosite & Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 4Q02 | Communications Riser Cupboard, South Wall Penetration | Packing Material | Insulation | Removed - Assumed Positive | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 6 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 5 | 5Q01 | Communications Riser Cupboard, On Top of Blockwork South Wall & Vertical Wall Expansion Joint | Packing Material | Insulation | Removed -Positive (Amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 6 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 6 | 6Q01 | Fire Hose Cupboard | Packing Material | Insulation | Removed | - | - | - | Item removed. Refer RiskTech Clearance Certificate 20210616 | Yes |
KENC | Kensington Campus | K17 | Building K17 | 7 | 703 | Lift Motor Room, North & East Walls | Packing Material | Insulation | Removed | - | - | - | Item removed. Refer RiskTech Clearance Certificate 20210616 | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1227 | - | Fire Panel Above Door | Core Insulation | Removed - Positive (amosite) | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 1 May 2020. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1027 | - | Fire Panel Above Door | Core Insulation | Positive (amosite) | Friable | Low | P3 | Remove fire panel by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 730 | - | Fire Panel Above Door | Core Insulation | Positive (amosite) | Friable | Low | P3 | Remove fire panel by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F21 | Library | 10 | 10Q8 | SW Fire Stairs, West | Structural Steel Element (Angle) | Insulation (encapsulated) | Positive (amosite) | Friable | Low | P3 | Consider removal of asbestos insulation from the steel angle under controlled conditions by a Class A contractor as part of a planned control program. | No |
KENC | Kensington Campus | F21 | Library | LG | LGQ08 | Redundant Chiller Plant Room | Inside Cable Tray / Ducts | Insulation Debris | Removed - 'Positive (amosite) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 22 June 2020 & 29 October 2021. | Yes |
KENC | Kensington Campus | F21 | Library | LG | LGQ08 | Redundant Chiller Plant Room | On Soffit & Adjacent Surfaces | Insulation Residue (mostly beneath white coloured encapsulant) | Removed - 'Positive (amosite) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 22 June 2020 & 29 October 2021. | Yes |
KENC | Kensington Campus | F21 | Library | LG | LGQ08 | Redundant Chiller Plant Room | Hot Water Pipework | Insulation (calico covered) | Removed - 'Positive (amosite) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 22 June 2020 & 29 October 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG06 | Biolink, | Fire Door | Insulation Core | Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New fire door). | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG06 | Biolink, | Walls & Ceiling | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed: Refer to WSP Clearance Certificate dated May 2017. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG01 | Biosciences North | Pipe System Flange Blanket | Woven Insulation | Removed - Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G22 | Biolink | Fire Door | Insulation Core | Positive - Removed | - | - | - | Item Removed: Refer to Greencap NAA Asbestos Clearance Certificate (Ref: C107266:J134916.003) dated 28 September 2015. (Note: New fire door tagged 'TDF 2014'). | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | GQ13 | Biolink | Ceiling Tiles | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | C6 | International House | G | G3 | Accommodation Room - Bulkhead Ceiling Space / Wardrobe Cupboard (upper area) | Hot Water Pipework | Insulation (localised exposed insulation) | Removed -Positive (amosite) | - | - | - | Item Removed: Refer to RiskTech Asbestos Clearance Certificate dated 23 December 2019. Removed by Pure Contracting. | Yes |
Kenc | Kensington Campus | C6 | International House | G | GQ8 | Plumbing Riser Adjacent Room G2 | Hot Water Pipework | Insulation (no insulation covering present) | Removed -Positive (amosite) | - | - | - | Item Removed: Refer to RiskTech Asbestos Clearance Certificate dated 23 December 2019. Removed by Pure Contracting. | Yes |
Kenc | Kensington Campus | C6 | International House | 1 | 196 | Female Amenities / Toilets - Plumbing Riser | On Floor, Walls & Other Surfaces | Insulation Residue & Debris | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 23rd December 2019 | Yes |
Kenc | Kensington Campus | C6 | International House | 2 | 296 | Female Amenities / Toilets - Plumbing Riser | On Floor, Walls & Other Surfaces | Insulation Residue & Debris | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 23rd December 2019 | Yes |
Kenc | Kensington Campus | C6 | International House | 2 | 299 | Male Amenities / Toilets - Plumbing Riser | On Floor, Walls & Other Surfaces | Insulation Residue & Debris | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 23rd December 2019 | Yes |
Kenc | Kensington Campus | C6 | International House | 3 | 396 | Female Amenities / Toilets - Plumbing Riser | On Floor, Walls & Other Surfaces | Insulation Residue & Debris | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 23rd December 2019 | Yes |
Kenc | Kensington Campus | C6 | International House | 3 | 399 | Male Amenities / Toilets - Plumbing Riser | On Floor, Walls & Other Surfaces | Insulation Residue & Debris | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 23rd December 2019 | Yes |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | G2 | South | Fire Damper Panel | Core Insulation | Positive (amosite) | Friable | Low | P3 | Remediation works on fire panels should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1510A | Below Windows, Behind Plasterboard Wall Panelling | Façade Spandrel Panel Brackets | Insulation | Positive (amosite) | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1123 | Below Windows, Behind Plasterboard Wall Panelling | Façade Spandrel Panel Brackets | Insulation | Positive (amosite) | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 1407 | Below Windows, Behind Plasterboard Wall Panelling | Façade Spandrel Panel Brackets | Insulation | Positive (amosite) | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G16 | Stage Left | Flue | Insulation (beneath metal sheet covering but localised exposed insulation) | Removed: Positive (amosite) | - | - | - | Item Removed. Refer to Risktech Compliance Asbestos Clearance Certificate dated 26 August 2019. | Yes |
KENC | Kensington Campus | F21 | Library | 2 | - | Old Northern Building Section, Eastern Shaft Openings (North, South & Centre) | On Soffit, Top of Ductwork & Adjacent Surfaces | Insulation Residue & Debris | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 25 March 2019. | Yes |
KENC | Kensington Campus | F21 | Library | 2 | - | Old Northern Building Section, | On Soffit & Adjacent Surfaces | Insulation Residue & Debris | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 11 February 2019. | Yes |
KENC | Kensington Campus | F21 | Library | 3 | - | Old Northern Building Section, Eastern Shaft Openings (North, South & Centre) | On Soffit, Top of Ductwork & Adjacent Surfaces | Insulation Residue & Debris | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 18 March 2019. | Yes |
KENC | Kensington Campus | F21 | Library | 3 | - | Old Northern Building Section, | On Soffit & Adjacent Surfaces | Insulation Residue & Debris | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 11 February 2019. | Yes |
KENC | Kensington Campus | F21 | Library | 4 | - | Old Northern Building Section, Western Shaft Openings (North, South & Centre) | On Soffit, Top of Ductwork & Adjacent Surfaces | Insulation Residue & Debris | Removed - Positive (amosite) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 11 March 2019. | Yes |
KENC | Kensington Campus | F21 | Library | 4 | - | Old Northern Building Section, Eastern Shaft Openings (North, Centre & South) | On Soffit & Adjacent Surfaces | Insulation Residue & Debris | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 2 December 2020. | Yes |
Kenc | Kensington Campus | C6 | International House | G | G28 | Accommodation Room | Fire Door | Insulation Core | Removed Positive (amosite) | - | - | - | Item Removed: Refer to Asbestos Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | G | G29 | Accommodation Room | Fire Door | Insulation Core | Removed - Positive (amosite) | - | - | - | Item Removed: Refer to Asbestos Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | G | G30 | Accommodation Room | Fire Door | Insulation Core | Removed - Positive (amosite) | - | - | - | Item Removed: Refer to Asbestos Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | 2 | 219 | Accommodation Room | Fire Panels Above Fire Door | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | 2 | 220 | Accommodation Room | Fire Door | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | 1 | 152 | Accommodation Room | Fire Door | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | 1 | 120 | Accommodation Room | Fire Door | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | 3 | 320 | Accommodation Room | Fire Panels Above Fire Door | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
KENC | Kensington Campus | K17 | Building K17 | 1 | 1Q02 | Pipe Work Riser Adjacent Room 110A (Toilets), Top of Block Work Walls | Packing Material | Insulation | Positive (Amosite) - Removed | - | - | - | Item removed 30/3/2019 by Pure Contracting - RiskTech Clearance Certifcate dated 1/4/2019 | Yes |
KENC | Kensington Campus | F21 | Library | 1 | 107 | South of Fire Stair (1Q1) | On Soffit Adjacent Column (brick header wall section removed) | Insulation | Removed - Positive (amosite) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 17 February 2019. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | MLG Q02 | Service Tunnel off Room LG5 | Pipework | Insulation | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 15 April 2019. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | 130A | Plant Room, Inside AHU No.5, Base of Return Air Shaft Duct | On Duct | Fibrous Insulation Debris | Removed - Positive (amosite) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 25 February 2019. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | 130A | Plant Room, Inside AHU No.5, Pre-Filter Area | On Filter Bags | Fibrous Insulation Debris | Removed - Positive (amosite) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 25 February 2019. | Yes |
Kenc | Kensington Campus | C6 | International House | G | G19 | Accommodation Room | Fire Door | Insulation Core | Removed - Positive (amosite) | - | - | - | Item Removed: Refer to Asbestos Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | 2 | 219 | Accommodation Room | Fire Door | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | G | G30 | Accommodation Room | Fire Panels Above Fire Door | Insulation Core | Removed - Positive (amosite) | - | - | - | Item Removed: Refer to Asbestos Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | G | G29 | Accommodation Room | Fire Panels Above Fire Door | Insulation Core | Removed - Positive (amosite) | - | - | - | Item Removed: Refer to Asbestos Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | 3 | 319 | Accommodation Room | Fire Panels Above Fire Door | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | 2 | 220 | Accommodation Room | Fire Panels Above Fire Door | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | 1 | 119 | Accommodation Room | Fire Panels Above Fire Door | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | G | G28 | Accommodation Room | Fire Panels Above Fire Door | Insulation Core | Removed - Positive (amosite) | - | - | - | Item Removed: Refer to Asbestos Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | G | G18 | Accommodation Room | Fire Panels Above Fire Door | Insulation Core | Removed - Positive (amosite) | - | - | - | Item Removed: Refer to Asbestos Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
KENC | Kensington Campus | F21 | Library | 14 | 1402 | Western Perimeter Wall Cavity, Behind Plasterboard Wall Lining | Sliding Fire Door ('Fire Control Pty Ltd' – Manufactured in 1974’) | Core Insulation | Positive (amosite) | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | C6 | International House | G | GQ3 | North Corridor, Adjacent Fire Stairs GQ2 | Fire Door | Insulation Core | Removed - Positive (amosite) | - | - | - | - | Yes |
Kenc | Kensington Campus | C6 | International House | 3 | 319 | Accommodation Room | Fire Door | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | 3 | 320 | Accommodation Room | Fire Door | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | 1 | 151 | Accommodation Room | Fire Door | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | 1 | 119 | Accommodation Room | Fire Door | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | G | GQ21 | Fire Stairs | Fire Door (tag 'Padde Fire Control 1972') | Insulation Core | Removed - Positive (amosite) | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 3 | 3Q2 | Fire Stairs | Fire Door (tag 'Advanced Metal Door Frames, 2015') | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 3 | 3Q6 | Fire Stairs | Fire Doors (tag 'Padde Fire Control 1972') | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 3 | 303 | Accommodation Room | Fire Door (tag 'Advanced Metal Door Frames, 2015') | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 3 | 3Q11 | Fire Stairs | Fire Door (tag 'Advanced Metal Door Frames, 2015') | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 2 | 2Q11 | Fire Stairs | Fire Door (tag 'Advanced Metal Door Frames, 2015') | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 2 | 2Q6 | Fire Stairs | Fire Doors (tag 'Padde Fire Control 1972') | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 1 | 1Q13 | Fire Stairs | Fire Door (tag 'Advanced Metal Door Frames, 2015') | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 1 | 1Q11 | Fire Stairs | Fire Door (tag 'Padde Fire Control 1972') | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 1 | 1Q5 | Fire Stairs | Fire Doors (tag 'Padde Fire Control 1972') | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | G | GQ22 | North Corridor, East End | Fire Door | Insulation Core | Removed - Positive (amosite) | - | - | - | Item Removed: Refer to Asbestos Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | G | GQ15 | South Corridor to G84 | Fire Door (tag 'Advanced Metal Door Frames, 2015') | Insulation Core | Removed - Positive (amosite) | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
KENC | Kensington Campus | F21 | Library | 1 | 1Q9 | Corridor (Outside Room 127), Localised Areas | On Top of Brick Wall & Ductwork | Insulation Debris | Removed - Positive (amosite) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 17 February 2019. | Yes |
KENE | Kensington Environs | AS24 | 24 Arthur Street | G | Ceiling Space, Throughout | Pipework Lagging | Insulation | Positive (Amosite) - Removed | - | - | - | No removal/clearance documentation was provided. | Yes | |
KENE | Kensington Environs | AS24 | 24 Arthur Street | G | - | Ceiling Space, Adjacent Ceiling Access Panel | Pipework Lagging | Insulation | Positive (Amosite) - Removed | - | - | - | No removal/clearance documentation was provided. | Yes |
Kenc | Kensington Campus | C6 | International House | 1 | 196 | Female Amenities / Toilets - Plumbing Riser | Hot Water Pipework | Insulation | Positive (Amosite) - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 1 | 199 | Male Amenities / Toilets - Plumbing Riser | Hot Water Pipework | Insulation | Removed - Positive (amosite) | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 2 | 296 | Female Amenities / Toilets - Plumbing Riser | Hot Water Pipework | Insulation | Positive (Amosite) - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 2 | 299 | Male Amenities / Toilets - Plumbing Riser | Hot Water Pipework | Insulation | Positive (Amosite) - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 3 | 396 | Female Amenities / Toilets - Plumbing Riser | Hot Water Pipework | Insulation | Positive (Amosite) - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 3 | 399 | Male Amenities / Toilets - Plumbing Riser | Hot Water Pipework | Insulation | Positive (Amosite) - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 1 | 120 | Accommodation Room | Fire Panels Above Fire Door | Insulation Core | Positive (Amosite) - Removed | - | - | - | Item Removed: Refer to Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | G | G94 | Plumbing Riser | Hot Water Pipework | Insulation | Removed - Positive (amosite) | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | G | G95 | Office - Ceiling Space | Hot Water Pipework | Insulation | Removed - Positive (amosite) | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | G | G97 | Office - Ceiling Space | Hot Water Pipework | Insulation | Removed - Positive (amosite) | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 130 | Biolink | Fire Door | Insulation Core | Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New fire door tagged 'Bismac 2006'). | Yes |
FSW | Wellington Field Station | WFS1 | Wellington Field Station Cottage | G | 1 | Main Residence, Exterior, All Sides | Eaves & Awning Ceiling | Fibre Cement Sheeting | Positive (Amosite, Chrysotile and Crocidolite) | Non-friable | Low | P3 | Repair/seal the localised damage areas and secure loose sheeting under controlled conditions within a planned control program. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
CCS | Cliffbrook Campus | CC1 | Cliffbrook House | G | - | Exterior, North-East | Cable Conduit | Moulded Fibre Cement | Positive (Amosite, Chrysotile and Crocidolite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B15 | Old Tote | 01 | - | Exterior, West Above Main Entrance | Wall Cladding | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 16th December | Yes |
KENC | Kensington Campus | B14D | Fig Tree Theatre | G | - | Exterior, North Side, under Roof Edge | Fascia Panelling | Fibre Cement Sheeting | Positive (Amosite, Chrysotile and Crocidolite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MISC | Miscellaneous | BC34 | Woolley House | 04 | - | Sub-Floor Space off Room G09 (Bed 3), Adjacent Hot Water Heater Unit | On Ground | Fibre Cement Sheet Debris | Positive (Amosite, Chrysotile and Crocidolite) | Non-friable | Med | P3 | Restrict access to the sub-floor space to authorised persons only. Remove debris under controlled conditions by a Class A/B contractor or competent person within a planned control programs. | No |
MISC | Miscellaneous | BC34 | Woolley House | 04 | - | Sub-Floor Space off Room G09 (Bed 3), Adjacent Hot Water Heater Unit | On Ground | Insulation Board Debris | Positive (Amosite, Chrysotile and Crocidolite) | Friable | Med | P2 | Restrict access to the sub-floor space to authorised persons only. Remove debris under controlled conditions by a Class A contractor as soon as practicable. | No |
KENC | Kensington Campus | D14 | UNSW Hall | G | EAGQ01 | GQ14 Corridor, Electrical Cupboard (DB-1) | Conduit | Moulded Fibre Cement | Positive (Amosite, Chrysotile and Crocidolite) | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
KENC | Kensington Campus | D14 | UNSW Hall | G | BG95 | Main Switch Room, South-East Corner | Electrical Conduits | Moulded Fibre Cement | Positive (Amosite, Chrysotile and Crocidolite) | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q12 | Biolink | Ceiling Tiles | Fibre Cement Sheeting | Removed -Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENE | Kensington Environs | BS30 | 30 Botany Street | 1 | 102 | Bathroom | Ceiling | Fibre Cement Sheeting | Positive (Amosite, Chrysotile and Crocidolite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | AS20 | 20 Arthur Street | G | - | Exterior, Garage, Surrounding | Eaves | Fibre Cement Sheeting | Positive (Amosite, Chrysotile and Crocidolite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS20 | 20 Arthur Street | G | - | Exterior, Garage | Wall Cladding | Fibre Cement Sheeting | Positive (Amosite, Chrysotile and Crocidolite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS10 | 10 Arthur Street | G | G08 | Shower Cubicle | Wall | Fibre Cement Sheeting | Positive (Amosite, Chrysotile and Crocidolite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENC | Kensington Campus | SST1 | Main Service Tunnel | G | - | Service Tunnel below Building G14 (Access via Service Tunnel F13 Branch) | Electrical Conduits | Moulded Fibre Cement Pipes | Positive (Chrysotile & Crocidolite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | 1Q23 | Service Tunnel, East End, North Wall | Conduits | Moulded Fibre Cement Pipes | Positive (chrysotile & crocidolite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B14D | Fig Tree Theatre | G | - | Exterior, North East, Entrance | Wall Cladding Around Doorway | Fibre Cement Sheeting | Positive (Chrysotile and Crocidolite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 137 | Biolink | Walls | Fibre Cement Sheeting | Removed -Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENE | Kensington Environs | WR41 | 41 Wansey Road | LG | - | Exterior, Backyard, North-East, to Neighbouring Property Shed | Wall | Fibre Cement Sheeting | Positive (Chrysotile and Crocidolite) | Non-friable | Low | P3 | Repair/seal localised damage under controlled conditions. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS10 | 10 Arthur Street | G | GQ4 | Exterior, Garage, South | Gable End | Fibre Cement Sheeting | Positive (Chrysotile and Crocidolite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENC | Kensington Campus | SST1 | Main Service Tunnel | G | - | Adjacent Entrance to F12 Branch, North Side | Old Gas Pipe Work Flange Joints | Gaskets | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 144 | Biolink | Fire Door | Insulation Core | Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
FSSL | Smiths Lake Field Station | SL6 | Smiths Lake COLA | G | - | Exterior, East | Inside Electrical Cabinet | Electrical Backing Board | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 535 | Biosciences North | Fire Door | Insulation Core | Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G7 | Electrical Cupboard | Conduit | Moulded Fibre Cement Pipe | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 6 | 6Q01 | Communications Riser | Debris | Loose Insulation | Removed | - | - | - | Item removed. Refer RiskTech Clearance Certificate 20210616 | Yes |
KENC | Kensington Campus | K17 | Building K17 | 7 | 706 | Roof Area, Near SE Corner | Inside Electrical Cabinet | Electrical Backing Board | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 541 | Biosciences North | Fire Door | Insulation Core | Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | J14 | Keith Burrows Theatre | G | - | Exterior, North Side | Window Frames (between frame and pane) | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J12 | Newton | G | G12 | Stairwell to Mezzanine Level (Room GM6A & GM6B) | Wall Lining | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J12 | Newton | G | G12 | Mezzanine Area (Room GM6A & GM6B) | Wall Lining | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Med | P3 | Remove fibre cement sheet south upper wall section in Room GM6A under controlled conditions by a Class A/B contractor as part of a program of works or prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J12 | Newton | R | R02 | Plant Room | Duct Work Joints | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J12 | Newton | G | G03 | Exterior, East Side of Building, Entrance to Electrical Switch Room | Wall Expansion Joints Around Door Frame | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | HS46 | 46 High Street | 01 | - | South-East Entrance Area | Vertical Expansion Joint Between Brickwork & Concrete Section | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 533 | Biosciences North | Walls | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 301 | Biosciences North | Fume Cupboard, Internal Lining | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 210B | Store Room (Formerley a Cool Room), East Wall | Duct Heater Bank | Millboard | Positive (Chrysotile) | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | RQ01 | Concrete Plinths, Beneath Metal Capping | Floor Covering | Bituminous Membrane | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
FSW | Wellington Field Station | WFS1 | Wellington Field Station Cottage | G | 1 | Main Residence, Exterior, West Side | Inside Electrical Cabinet | Electrical Backing Board | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | - | Exterior, Sub-Floor Space | On Ground, Debris | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P3 | Restrict access to the sub-floor space area to authorised personnel only. Remove fibre cement sheet debris under controlled conditions within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 17 | 1704 | Cooling Tower Room | Floor & Support Structures | Bituminous Membrane (beneath new non-asbestos membrane) | Removed - Positive (chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 2 December 2019. Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 1 | M1Q04 | Service Tunnel Access off Room 116, East End | Inside Electrical Cabinet | Electrical Backing Board | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | M1Q04 | Service Tunnel Access off Room 116, East End, East & South Walls | Conduits | Moulded Fibre Cement Pipes | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 313 | Between East Wall & Perimeter South Wall | Expansion Joint | Sealant Mastic | Positive (Chrysotile) - removed | - | - | - | Item removed. Refer Airsafe clearance cert dated 13-17/10/23 | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1228 | - | Fire Panel Above Door | Core Insulation | Removed - Assumed Positive (amosite) | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 1 May 2020. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q5 | Plant Room (access via Fire Stairs 4Q7) | Ductwork Flange Joins | Sealant Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 10 | 10Q8 | Duct (Shaft) off SW Fire Stairs, North | Ducwork Flange Joins | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | 1Q12 | Electrical Room off Fire Stairs (1Q2) | On Soffit Surrounding Column | Insulation Residue & Bituminous Coating (adhesive) | Removed -Positive (chrysotile) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 25 May 2000. | Yes |
KENC | Kensington Campus | F21 | Library | LG | LGQ05 | Plant Room - Air Handling Unit | Air Handling Unit, Panel Joins | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | Yes |
KENC | Kensington Campus | F21 | Library | 15 | 1501 | Plant Room | Toilet Exhaust Ductwork, Joints & Joins | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | GQ6A | Electrical Cupboard Adjacent Room G24A Toilets | - | Electrical Backing Board | Removed - Positive (chrysotile) | - | - | - | Item Removed: No removal or clearance documentation available. | Yes |
KENC | Kensington Campus | F20 | Goodsell | G | - | Exterior, East Side, North East Corner, Outside Room G2A, Covered Exit | Awning Roof | Bituminous Membrane | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 221 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F17 | Rex Vowels Theatre | 1 | LGQ5 | Plant Room, Level 1 | Duct Work Joints | Mastic Sealant | Positive - removed | Item removed. Refer RiskTech clearance cert dated Dec 23 | Yes | |||
KENC | Kensington Campus | F13 | Science Theatre | G | - | Exterior, Eastern Façade | Window Frames (between frame & pane) | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G11 | East | Window Frames (between frame & pane) | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G07 | Electrical Cupboard | Floor | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | - | Exterior, Façade | Windows (between frame and façade wall) | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | - | Exterior, Façade (access via room 318) | Windows (between frame and façade wall) | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 301B | Biosciences North | Fume Cupboard, Internal Lining | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 416 | Biosciences North | Fume Cupboard, Internal Lining | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 510 | Biosciences North | Fume Cupboard, Internal Lining | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | D23 | Mathews Theatres | 01 | - | Exterior, West Side | Expansion Joint between Brickwork Wall Sections | Mastic Sealant | Positive (chrysotile) | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 01 | 101 | Ductwork Service Risers | Ductwork Joins | Mastic Sealant (red colour) | Positive (chrysotile) | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 01 | 101 | Ductwork Service Risers | Ductwork Flange Joints | Mastic Sealant (black colour) | Positive (chrysotile) | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D14 | UNSW Hall | G | FAGQ01 | GQ14 Corridor, North Fire Hydrant Cupboard, Ceiling Height | Loose Penetration Cover | Fibre Cement Sheeting | Positive (Chrysotile) | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
Kenc | Kensington Campus | D14 | UNSW Hall | G | A90 | Exterior, East | Window Frames (between frame and pane) | Mastic Sealant | Positive (Chrysotile) | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 301A | Biosciences North | Walls | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q7 | Fire Hose Reel Cupboard, | Wall | Fibre Cement Sheeting | Positive (Amosite & Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 131A | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech Clearance cert dated 28/09/2021 | Yes |
Kenc | Kensington Campus | G15 | Robert Webster Theatres | 02 | 290A | Lecture Theatre B, East Side Projector Room, Roof Space | Ductwork Joints & Joins | Mastic Sealant (black colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 352 | Biolink, | Walls | Fibre Cement Sheeting | Positive (Amosite & Chrysotile) - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17th November 2021 | Yes |
Kenc | Kensington Campus | D16 | Goldstein Hall | G | GQ13 | Main Switch Room | Electrical Distribution Board Cabinet | Electrical Backing Board | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to refurbishment. | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | G4B | Female Toilet, Riser | Ductwork Joints & Joins | Mastic Sealant (red colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | LG | LG1 | Air Handling Unit | Joins | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | 01 | - | Roof Space | Old Ductwork Joins | Mastic Sealant (white colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | - | Exterior, Eastern Side of Building, Southern End | Window Sill Expansion Joint | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | - | Exterior, West Side of Building | Wall Expansion Joint | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | - | Exterior, North-West Corner of Building | Window Sill Expansion Joint | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 2Q24 | Exterior, South | Windows (between frame and pane) | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q17 | South Roof Section (beneath concrete plinths supporting plant & equipment) | Roof | Bituminous Membrane | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 11 | - | Roof Above Lounge (roof above former Room 1111, 1113, 1114 & 1115 and Covered Terrace) | Roof Covering (beneath new membrane) | Bituminous Membrane | Removed - Positive (Chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 21 October 2019. | yes |
KENC | Kensington Campus | F13 | Science Theatre | 2 | - | Throughout, Above Stage (G17, G18 & G19) & Auditorum (G9) and Roof Space | Former Roof Cladding (below new metal roof cladding & support structure) | Bituminous Felt Coated Metal Sheeting ('galbestos') | Positive (Chrysotile) | Non-friable | Low | P4 | Pure Contracting undertook set up works involving segregating of the work area, laying plastic sheeting beneath and adjacent to the covered walkway and installing warning signage. The removal of the asbestos containing membrane was undertaken using hand tools and hammer drills fitted with lifting blades, where necessary. Following the removal works, the work area was cleaned with Type H HEPA vacuum cleaners and wet wiping methods. Asbestos waste was placed in labelled 200 μm asbestos waste bags and then transported from site. | Yes |
KENC | Kensington Campus | F13 | Science Theatre | G | G16 | Stage Left | Ceiling | Fibre Cement Sheeting | Positive (chrysotile) | Non-friable | Low | P3 | Consider sealing the edges of the ceiling sheets under controlled conditions by a Class A/B contractor as part of a planned control program. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MISC | Miscellaneous | BC34 | Woolley House | 02 | UGQ02 | Exterior, Level 2, Deck, Common to Room G06 (Bed 1) | Windows (between glass & internal timber framework) | Caulking Mastic | Positive (Chrysotile) | Non-friable | Low | P3 | Repair or remove deteriorating window caulking under controlled conditions by a Class A/B contractor or competent person within a planned control programs. | No |
MISC | Miscellaneous | BC34 | Woolley House | 02 | G05 | Living (common to Deck UGQ02) | Windows (between glass & internal timber framework) | Caulking Mastic | Positive (Chrysotile) | Non-friable | Low | P3 | Repair or remove deteriorating window caulking under controlled conditions by a Class A/B contractor or competent person within a planned control programs. | No |
MISC | Miscellaneous | BC34 | Woolley House | 02 | G06 | Bed 1 | Windows (between glass & internal timber framework) | Caulking Mastic | Positive (Chrysotile) | Non-friable | Low | P3 | Repair or remove deteriorating window caulking under controlled conditions by a Class A/B contractor or competent person within a planned control programs. | No |
RANC | Randwick Campus | R1 | Randwick R1 | LG | - | Tunnel or Former Open Pit, Northern Section, East of Access Point (via floor manhole cover) | Stockpile Demolition Material | Fibre Cement Sheeting | Positive (chrysotile) | Non-Friable | Low | P3 | Restrict access to the tunnel (former pit) to authorised personnel. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | - | Exterior, Façade, North Open Balcony | Vertical Joint Between Base of Metal Window Framework & Concrete Façade Panel | Sealant Mastic (dark grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | - | Exterior, Façade, Covered Verandah U3Q02 | Horizontal Joint Between Base of Metal Window Framework & Concrete Façade Panel | Sealant Mastic (dark grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 1410 | North | Vertical Expansion Wall Joints | Sealant Mastic (grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | - | Exterior, Façade, North, 2nd Bay from East Side | Vertical Joint (joint closest to window) Between Metal Window Framework & Column | Sealant Mastic (dark grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | - | Exterior, Façade, North, 2nd Bay from East Side | Vertical Joint (joint closest to column) Between Metal Window Framework & Column | Sealant Mastic (dark grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | - | Exterior, Façade, North, 2nd Bay from East Side | Horizontal Joint Between Base of Metal Window Framework & Concrete Façade Panel | Sealant Mastic (dark grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | - | Exterior, Façade, South | Vertical Joint (joint closest to column) Between Metal Window Framework & Column | Caulking Sealant (grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1219 | South | Between Lower Metal Window Framework & Glass | Sealant Mastic (grey & black colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 818 | South | Between Lower Metal Window Framework & Glass | Sealant Mastic (grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 1410 | North | Between Lower Metal Window Framework & Glass | Sealant Mastic (grey & black colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1503 | North | Between Lower Metal Window Framework & Glass | Sealant Mastic (grey & black colour) | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1512 | South | Between Lower Metal Window Framework & Glass | Sealant Mastic (grey & black colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | - | Exterior, Façade, South, Far SE Corner | Vertical Joint Between Metal Window Framework & Concrete Façade Panel | Sealant Mastic (dark grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | - | Exterior, Façade, East, Far SE Corner | Horizontal Joint Between Base of Metal Window Framework & Concrete Façade Panel | Sealant Mastic (dark grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | - | Exterior, Façade, South | Vertical Joint (joint closest to column) Between Metal Window Framework & Column | Caulking Sealant (grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 11 | - | Roof Area, Exterior, Façade | Between Metal Window Framework & Glass | Mastic Sealant (dark grey/black colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | - | Exterior, Façade, South | Vertical Joint (joint closest to window) Between Metal Window Framework & Column | Caulking Sealant (grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | - | Exterior, Façade, Old Low Rise Northern Brick Section | Between Metal Window Framework & Glass | Caulking Mastic (brown colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | - | Exterior, Façade, South | Between Lower Metal Window Framework & Glass | Caulking Sealant (grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | - | Exterior, Façade, Tower Section, East (Section Adjoining Rear of Bank Building) | Vertical Joint Between Metal Window Framework & Concrete Façade Panel | Sealant Mastic (grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | - | Exterior, Façade, Tower Section, East | Vertical Joint Between Brick Wall & Concrete Façade Panel | Sealant Mastic (grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | - | Exterior, Façade, South | Between Lower Metal Window Framework & Glass | Sealant Mastic (dark grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | - | Exterior, Façade, South Tower Section, South | Vertical Joint Between Concrete Façade Panel & Column | Sealant Mastic (grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | - | Exterior, Façade, South Tower Section, South | Between Metal Window Framework & Glass | Mastic Sealant (dark grey/black colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | - | Exterior, Façade, South Tower Section, South | Horizontal Joint Between Metal Window Framework & Concrete Façade Panel | Sealant Mastic (grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | - | Exterior, Façade, South, Far SE Corner | Joint Between Metal Window Framework & Façade | Sealant Mastic (dark grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q7 | East & West | Walls | Fibre Cement Sheeting | Removed - Positive (amosite & chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 2 February 2022. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q8 | South, East & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q6 | Biolink, East & West | Walls | Fibre Cement Sheeting | Removed -Positive (amosite & chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 December 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q6 | Biolink, South, East & West | Walls | Fibre Cement Sheeting | Removed -Positive (amosite & chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 November 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 564 | North, South , East & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 567 | North, South & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 570 | South & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 569A | North & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 566 | North, South, East & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 568 | North, South & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 565 | North, South & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 562 | North, East & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | - | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 142 | Biolink, North & West | Walls | Fibre Cement Sheeting | Removed -Positive (amosite & chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 30 October 2020, 11 December 2020 & 28 September 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 449 | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 17/12/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 448B | Biolink, North, South & East | Walls | Fibre Cement Sheeting | Removed -Positive (amosite & chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 December 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 448 | South & East | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | G02 | Store | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 455A | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 17/12/2021 | Yes |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | - | Exterior, All Sides | Eaves (Note: Localised damage area on north side, NW corner) | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P3 | Remedial works should be undertaken by a Class A/B Contractor or competent person within a planned control program. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 357A | Biolink, | Walls | Fibre Cement Sheeting | Positive (Amosite & Chrysotile) - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 138A | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech Clearance cert dated 28/09/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 343 | Biolink, | Pipe Penetrations | Rope Packing Insulation | Positive (Amosite & Chrysotile) - removed | - | - | - | Item removed. Refer Risktech Clearance cert dated 17/11/2021. | Yes |
KENE | Kensington Environs | O14 | Kangas House | G | 8B | Below Windows & Sink | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | O14 | Kangas House | G | 9 | Northern Side, Adjacent Skylights | Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | O14 | Kangas House | G | 9A | Northern Side, Adjacent Skylights | Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | MS48A | Owls House Building 2 | G | - | Exterior, South Side | Gable Wall Panelling | Fibre Cement Sheeting | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | M2Q01 | Plant Room | Ductwork Joins | Sealant Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | G | G10D | Mezzanine Above G10D | Former Generator Plant | Gaskets | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
FSW | Wellington Field Station | WFS1 | Wellington Field Station Cottage | G | 2 | Laundry, All Sides | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P3 | Repair/seal the localised damage areas to the wall sheeting under controlled conditions within a planned control program. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS2A | Wellington Field Station Accommodation | G | G01 | Throughout | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P3 | Repair/seal the localised damage areas to the wall sheeting under controlled conditions within a planned control program. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS2A | Wellington Field Station Accommodation | G | G02 | Throughout | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P3 | Repair/seal the localised damage areas to the wall sheeting under controlled conditions within a planned control program. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS2A | Wellington Field Station Accommodation | G | G03 | Throughout | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P3 | Repair/seal the localised damage areas to the wall sheeting under controlled conditions within a planned control program. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS2A | Wellington Field Station Accommodation | G | G04 | Throughout | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P3 | Repair/seal the localised damage areas to the wall sheeting under controlled conditions within a planned control program. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS2A | Wellington Field Station Accommodation | G | G05 | Throughout | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P3 | Repair/seal the localised damage areas to the wall sheeting under controlled conditions within a planned control program. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS2A | Wellington Field Station Accommodation | G | - | Exterior, All Sides | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P3 | Repair/seal the localised damage areas to the wall sheeting under controlled conditions within a planned control program. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS2 | Wellington Field Station Shearing Shed | G | G01 | West Side, Toilets & Shower Room, Corridor, Laboratory & SW Corner Room | Floor Covering | Vinyl Tiles (white colour) | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS2 | Wellington Field Station Shearing Shed | G | G01 | West Side, NW Corner Room & Adjacent Kitchen | Floor Covering | Vinyl Tiles (white colour) | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSSL | Smiths Lake Field Station | SL1 | Smiths Lake Laboratory | G | UGQ2 | Exterior, South Note: Eastern section of eaves on south side is masonite | Eaves | Fibre Cement Sheeting | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 2Q7 | Biolink, East (common to Room 260) | Walls | Fibre Cement Sheeting | Removed -Positive (amosite & chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 13 October 2021. | Yes |
FSSL | Smiths Lake Field Station | SL1 | Smiths Lake Laboratory | G | - | Exterior, East | Inside Electrical Cabinet | Electrical Backing Board | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 142A | Biolink, | Wall | Fibre Cement Sheeting | Removed | - | - | - | item removed. Refer Risktech Clearance cert dated 28/09/2021 | Yes |
RANC | Randwick Campus | R5 | Randwick R5 | G | - | Exterior, North, Ground Surfaces (assumed present beneath vegetation / leaf litter) | Debris | Fibre Cement Sheeting | Positive (chrysotile) | Non-Friable | Medium | P3 | Restrict access to north side ground surfaces. Undertake removal/remedial works of fibre cement sheeting debris within a planned control program. | No |
RANC | Randwick Campus | R1f | Randwick R1f | G | - | Exterior, South & West of Building, Ground Surface | Debris | Fibre Cement Sheeting | Positive (chrysotile) (Removed) | - | - | - | Item Removed: RiskTech Compliance removed fibre cement debris as part of the inspection process. | Yes |
RANC | Randwick Campus | R1 | Randwick R1 | G | G28 | Under New Vinyl Floor Sheet | Floor Covering (suspected present beneath sheet vinyl) | Vinyl Tiles (tan colour) | Positive (chrysotile) | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MANV | Manly Vale | MV12 | Cool Room | G | G01 | - | Floor Covering Underlay (beneath sheet vinyl floor covering) | Bituminous Material | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | LG | LG42 | Electrical Switch Room | Floor Covering (suspected beneath grey sheet vinyl) | Vinyl Tiles (beige colour) | Positive (chrysotile) | Non-friable | Low | P4 | Confirm presence and extent of asbestos containing vinyl floor tiles beneath grey sheet vinyl and if present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment | No |
KENC | Kensington Campus | K14 | Physics Theatre | LG | LG13 | - | Floor Covering | Vinyl Tiles (grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | J14 | Keith Burrows Theatre | G-1 | - | Exterior, North, West & East Sides | Vertical Wall Expansion Joints | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 01 | 1Q1 | Stairwell, South | Windows (between frame and glazing) | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | G15 | Robert Webster Theatres | 01-02 | - | Exterior, West Side | Façade Wall Panel Joints | Pointing | Positive (chrysotile) | Non-friable | Med | P3 | Remediate (remove and/or seal) under controlled conditions by a Class A/B contractor within a planned control program. | No |
KENC | Kensington Campus | F13 | Science Theatre | 2 | - | Stage, Mezzanine Level, North | Service Riser Panelling | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G07 | Electrical Cupboard, East and West | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | G | - | Exterior, South | Walkway Roof Covering | Bitumen Membrane | Removed: Positive (chrysotile) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 12 February 2024. | Yes |
KENC | Kensington Campus | F12 | Dalton | G | - | Exterior, East of Building, Covered Walkway | Roof Covering | Bituminous Membrane | Positive (chrysotile) | - | - | - | Item Removed - Refer to RiskTech Compliance Asbestos Clearance Certificate dated 12 February 2024. | No |
KENC | Kensington Campus | F12 | Dalton | 02 | 2Q2 | North-East & South-East | Window Frames (between frame and pane) | Mastic Sealant | Positive (chrysotile) | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 141A | Biolink, | Wall | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech Clearance cert dated 28/09/2021 | Yes |
KENC | Kensington Campus | D23 | Mathews Theatres | 01 | 150 | Plant Room, Western Section | Ductwork Flange Joints | Mastic Sealant (grey colour) | Positive (chrysotile) | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions prior to demolition or refurbishment. | No |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | - | Exterior, East & West | Eaves | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | - | Exterior, All Sides | Eaves | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G09 | Kitchen | Floor Covering | Vinyl Tiles | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | GQ7 | Mens Toilet & Amenities | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | GQ2 | Corridor | Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | GQ2 | Corridor | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G07A | Pantry | Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G07 | Kitchen | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G07A | Pantry | Floor Covering | Vinyl Tiles | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G07 | Kitchen | Floor Covering | Vinyl Tiles | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | - | Carport, South & East | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P3 | Repair/seal the localised damage areas under controlled conditions within a planned control program. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | - | Far SW Corner Room, Toilet (former uncovered awning) | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | G01 | Far NW Corner Room, | Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 256 | North, South & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktach Clearance cert dated 13/10/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 255 | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech Clearance cert dated 13/10/2021 | Yes |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | UCA | Exterior, Northern Side, Uncovered Awning Area | Awning Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P3 | Repair/seal the localised damage areas under controlled conditions within a planned control program. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | UCA | Exterior, Southern Side, Uncovered Awning Area | Awning Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS2 | Hay Field Station Workshop | G | - | Exterior, West Side (Outside Room G04) - On Ground | Disused Pipe Collar | Moulded Fibre Cement Material | Positive (Chrysotile) | Non-friable | Low | P3 | Remove disused fibre cement pipe collar under controlled conditions within a planned control program. | No |
FSFG | Fowlers Gap Field Station | FG1 | Fowlers Gap Solarch House | G | G12 | Southern Store Room Adjacent Carport | Flooring | Compressed Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG1 | Fowlers Gap Solarch House | G | G13 | Southern Store Room Adjacent Carport | Flooring | Compressed Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG4 | Fowlers Gap Cottage 5 | G | - | Exterior, Subfloor Space | On Top of Brick Suppport Piers - Packing | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG15 | Fowlers Gap Cottage 1 | G | - | Exterior, Verandah, North, East and West Sides | Flooring | Compressed Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 272 | Biolink, East | Wall | Fibre Cement Sheeting | Removed -Positive (amosite & chrysotile) | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 132A | Biolink, North, South, East & West (above cool room) | Walls | Fibre Cement Sheeting | Removed -Positive (amosite & chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 28 September 2021. | Yes |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | G05 | Laundry | Floor Covering | Sheet Vinyl | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | - | Exterior, All Sides | Walls | Profiled Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Removed between 26/08/2024 to 31/08/2023 as per Asbestos Clearance Certificate dated 03/09/2024 | Yes |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | G05 | Near SE Corner, Entrance Area to Laundry | Floor Covering | Vinyl Tiles | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | G17 | Northern Toilets & Showers | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | G18 | Northern Toilets & Showers | Walls (Note: Localised damaged area - temporarily covered) | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P3 | Remedial works should be undertaken by a Class A/B Contractor or competent person within a planned control program. | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | G04 | Laboratory Store | Floor Covering | Vinyl Tiles (green and brown colour) | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 132B | Biolink, North, South, East & West | Walls | Fibre Cement Sheeting | Removed -Positive (amosite & chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 28 September 2021. | Yes |
KENE | Kensington Environs | BS30 | 30 Botany Street | 1 | 114 | North-East, Low Level | Infill Panels | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | BS30 | 30 Botany Street | G | UGQ01 | South Entrance to Level 1 | Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | AS22 | 22 Arthur Street | G | - | Exterior, Main Residence, Rear, South, East and West | Wall Cladding | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS22 | 22 Arthur Street | G | - | Verandah | Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS8 | 8 Arthur Street | G | - | Exterior, Garage, North and South | Gable | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS4 | 4 Arthur Street | G | G12 | Exterior, Garage, North | Gable | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS4 | 4 Arthur Street | G | - | Exterior, Verandah, South | Eaves | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS2 | 2 Arthur Street | G | - | Rear Sunroom, South, East and West | Wall Lining | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENC | Kensington Campus | F13 | Science Theatre | LG | LG1 | Plant Room | Air Conditioning Ductwork Flange Joints | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | C6 | International House | 1 | 199 | Male Amenities / Toilets - Plumbing Riser | Flues x 2 | Compressed Bituminous Pipes | Removed - Positive (visually confirmed) | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 2 | 299 | Male Amenities / Toilets - Plumbing Riser | Flues x 2 | Compressed Bituminous Pipes | Positive - Removed (visually confirmed) | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 3 | 399 | Male Amenities / Toilets - Plumbing Riser | Flues x 2 | Compressed Bituminous Pipes | Positive - Removed (visually confirmed) | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 132 | Biolink, South & East | Walls | Fibre Cement Sheeting | Removed -Positive (amosite & chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 28 September 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 138 | Biolink | Ceiling Tiles | Fibre Cement Sheeting | Removed -Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 134 | Biolink, North, South, East & West | Walls | Fibre Cement Sheeting | Removed -Positive (amosite & chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 28 September 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | GQ13 | Biolink, | Walls | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed: Refer to Risktech Clearance Certificate dated 10 September 2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G21 | Biolink, | Pipe Penetrations | Rope Packing Insulation | Positive - Removed | - | - | - | Item Removed: Refer to Risktech Clearance Certificate dated 10 September 2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG30 | Biosciences North, | Inside Electrical Cabinet | Electrical Backing Board Debris | Positive (Chrysotile) | Non-friable | Low | P3 | Remove under controlled conditions by a Class A/B contractor as part of a planned control program or prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG30 | Biosciences North, | Inside Electrical Cabinet | Electrical Backing Board | Positive (Chrysotile) | Non-friable | Low | P4 | Remediate under controlled conditions by a Class A/B contractor as part of a planned control program or prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | R01 | Plant Room, Throughout | Old Air Conditioning Ductwork - Flange Joints & Joins | Sealant Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 352 | Biolink | Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17th November 2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554A | - | Ceiling | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 555 | - | Ceiling Tiles | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/22 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 561 | - | Fume Cupboard, Internal Lining | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450 | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 17/12/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 457 | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 349 | Biolink, | Walls | Fibre Cement Sheeting | Positive (Chrysotile) - removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/11/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 260 | Biolink, | Pipe Penetrations | Rope Packing Insulation (suspected beneath sealant covering) | Removed | - | - | - | Item removed. Refer Risktech Clearance cert dated 13/10/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q7 | Biolink, | Pipe Penetrations | Rope Packing Insulation | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450 | Biolink, | Pipe Penetrations | Rope Packing Insulation | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 257 | Biolink | Fume Cupboard, Internal Lining | Fibre Cement Sheeting | Removed -Positive (chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 13 October 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 260 | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech Clearance cert dated 13/10/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 258 | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech Clearance cert dated 13/10/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 257 | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech Clearance cert dated 13/10/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 138A | Biolink, | Ceiling | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech Clearance cert dated 28/09/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 141A | Biolink, | Pipe Penetrations | Rope Packing Insulation | Removed | - | - | - | Item removed. Refer RiskTech Clearance cert dated 28/09/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 139 | Biolink | Air Conditioning Ductwork - Flange Joints | Sealant Mastic | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G23 | Biolink, | Wall | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed: Refer to Risktech Clearance Certificate dated 10 September 2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 343 | Biolink | Floor Covering | Vinyl Floor Tiles (mustard coloured) | Assumed Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | 101 | Laundry | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | 101 | Laundry | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | 102 | Garbage Bin Room | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | 105 | Laundry | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | 105 | Laundry | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | 107 | Garbage Bin Room | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | 107 | Garbage Bin Room | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | 110 | Laundry | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | 110 | Laundry | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | 114 | Laundry | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 360 | Biolink | Floor Covering | Vinyl Floor Tiles (mustard coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | J14 | Keith Burrows Theatre | G | G03 | Male Toilet, Ceiling Space | Ductwork Joins | Mastic Sealant (red colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | J12 | Newton | 1 | 1Q2 | Opposite Lifts | Windows | Mastic Sealant | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | J12 | Newton | 3 | 3Q1 | Opposite Lifts | Windows | Mastic Sealant | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | LG | LG04 | Plant Room, Adjacent Entrance | Air Conditioning Ductwork Heater Bank | Insulation Board | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q6 | Biolink | Floor Covering | Vinyl Floor Tiles (mustard coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q9 | Biolink | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 15 | 1501 | Plant Room | Vertical Wall Stiffeners (behind metal cover) | Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 15 | 1501 | Plant Room | On Top of Blockwork Walls | Insulation Packing | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F13 | Science Theatre | 1 | 110A | Throughout | Cubicle Partitions | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G12A/G13A | Male and Female Toilets | Cubicle Partitions | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F13 | Science Theatre | 1 | 101A | Throughout | Cubicle Partitions | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 448 | Biolink | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 448B | Biolink | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 449 | Biolink | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450C | Biolink | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP1 | Central Amenities | G | GQ4, GQ5, GQ6, GQ7, G07, G08 | Throughout | Wall Lining | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP1 | Central Amenities | G | GQ10, GQ11, GQ12, GQ13, G12, G14, G15 | Throughout | Cubicle Partitions | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP1 | Central Amenities | G | GQ10, GQ11, GQ12, GQ13, G12 G14, G15 | Throughout | Wall Lining | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | B15 | Old Tote | G | - | Exterior, Surrounding | Windows | Mastic sealant | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | B15 | Old Tote | 02 | - | Exterior, Surrounding | Windows | Mastic sealant | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | B14D | Fig Tree Theatre | G | 2 | Make Up/Preparation Rooms | Floor Covering under Carpet Tiles | Vinyl Tiles (Cream colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | B14D | Fig Tree Theatre | G | 1 | Hallway (only) | Floor Covering under Carpet Tiles | Vinyl Tiles (cream colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | B14D | Fig Tree Theatre | G | 2 | Make Up/Preparation Rooms | Floor Covering under Carpet Tiles | Vinyl Tiles (Brown colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | B14D | Fig Tree Theatre | G | 1 | Hallway (only) | Floor Covering under Carpet Tiles | Vinyl Tiles (Brown colour) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450E | Biolink | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 05 | 5Q4 | Exterior, Surrounding | Eaves | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450F | Biolink | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | G | G02 | Throughout | Cubicle Partitions | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | G | G11A | Change Room adjacent Female Bathroom | Cubicle Partitions | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | G | G09 | Male Bathroom | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | G | G09A | Male Bathroom | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | G | G10 | Female Bathroom | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | G | G10A | Female Bathroom | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | G | G12 | Equipment Store 1 | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | - | Exterior, Surrounding | Awning Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | LG | - | Various Toilet Riser Ducts | Waste Pipe | Moulded Fibre Cement | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | G | - | Various Toilet Riser Ducts | Waste Pipe | Moulded Fibre Cement | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | 01 | - | Various Toilet Riser Ducts | Waste Pipe | Moulded Fibre Cement | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | 02 | - | Various Toilet Riser Ducts | Waste Pipe | Moulded Fibre Cement | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | 03 | - | Various Toilet Riser Ducts | Waste Pipe | Moulded Fibre Cement | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E12 | UNSW Business School | G-6 | - | Toilets Throughout | Wall Linings | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E12 | UNSW Business School | 6 | 6Q13 | Male Toilet | Wall Linings | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP4 | Grounds Depot | G | G02 | Shower | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP4 | Grounds Depot | G | G02 | Shower | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP4 | Grounds Depot | G | G02 | Toilet | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | 01 | 1Q7 | - | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | 01 | 1Q7 | Behind Ceramic Walls Tiles | Wall Linings | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | 01 | 1Q10 | Throughout, Behind Ceramic Walls Tiles | Wall Linings | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | 01 | 1Q11 | Throughout, Behind Ceramic Walls Tiles | Wall Linings | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | G | GQ10 | - | Wall Linings | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D10 | Building D10 | G | GQ1 | Exterior, at Entrance | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | G | - | Exterior, West | Ceiling Panels | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 01 | - | Exterior, North-East Terrace | Ceiling Panels | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 04 | - | Exterior, North-West Terrace | Ceiling Panels | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAE | Block E | G | JEGQ01 | Exterior | Ceiling Panels | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | 03 | D3Q3 | Cooling Tower Plant Room | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | G13A | Behind Ceramic Walls Tiles | Wall Linings | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | G | - | Interior Throughout Level, Various Rooms, Under Carpet | Floor Covering | Vinyl Floor Tiles (white colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | - | Interior Throughout Level, Various Rooms, Under Carpet | Floor Covering | Vinyl Floor Tiles (white colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | - | Interior Throughout Level, Various Rooms, Under Carpet | Floor Covering | Vinyl Floor Tiles (white colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | - | Interior Throughout Level, Various Rooms, Under Carpet | Floor Covering | Vinyl Floor Tiles (white colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | G | - | Interior Throughout Level, Various Rooms, Under Carpet | Floor Covering | Vinyl Floor Tiles (cream colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | - | Interior Throughout Level, Various Rooms, Under Carpet | Floor Covering | Vinyl Floor Tiles (cream colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | - | Interior Throughout Level, Various Rooms, Under Carpet | Floor Covering | Vinyl Floor Tiles (cream colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | - | Interior Throughout Level, Various Rooms, Under Carpet | Floor Covering | Vinyl Floor Tiles (cream colour) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | C15 | White House | 01 | 1Q3 | Male Toilet | Wall Lining | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | C15 | White House | 01 | 1Q5 | Male Toilet | Wall Lining | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | C15 | White House | 01 | 1Q6 | Female Toilet | Wall Lining | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | C15 | White House | 01 | 1Q7 | Female Toilet | Wall Lining | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | - | Exterior, Throughout | Windows (between frame and pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | 01 | - | Interior, Throughout | Windows (between frame and pane) | Mastic Sealant | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | LG | - | Exterior, North Side, Outside Room LG28 | Windows (between frame and pane) | Mastic Sealant | Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | G | - | Exterior, Eastern Side, Near SE Corner Amenities Block | Infill Wall Panelling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | G | GQ3 | North Corridor, East End | Fire Door | Insulation Core | Assumed Negative | - | - | - | - | No |
MISC | Miscellaneous | BC34 | Woolley House | - | - | Exterior, Outside Laundry Entry | Eaves | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
MISC | Miscellaneous | BC34 | Woolley House | 02 | GQ02 | Ensuite | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 455A | Biolink | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q6 | Biolink | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 551 | - | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 551A | - | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 2 | 214 | - | Beams | Insulation (vermiculite) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 1 | 126 | - | Soffit Surrounding Columns | Insulation Board (vermiculite) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 1 | 128 | - | Soffit Surrounding Columns | Insulation Board (vermiculite) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 4 | 480A | - | Floor Covering | Vinyl Floor Tiles (cream colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 4 | 4Q4 | Fire Stairs | Floor Covering | Vinyl Floor Tiles (cream colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 4 | 4Q9 | - | Floor Covering | Vinyl Floor Tiles (cream colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | G | G05 | South adjoining Room | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | G | G07 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | G | G08 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | G | G11 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | G | G12 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | G | G12A | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | G | G13 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | G | G14 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | G | G14A | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | G | G14B | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R1 | Randwick R1 | G | - | Ceiling Space, South | Air Conditioning Ductwork Heater Bank | Insulation Board | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 1 | - | Surrounding Brick Walls (inspected in Rooms 1Q2, 101-110, 113-115 & 134) | Expansion Joints | Mastic Sealant | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | LG | LG05B | Ceiling Space | Air Conditioning Ductwork Heater Bank | Insulation Board | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | G | - | Ceiling Space (Inspected in Rooms G09C, GQ1, GQ3, GQ4 during 2008 Inspections) | Air Conditioning Ductwork Heater Bank | Insulation Board | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 1 | - | Ceiling Space | Air Conditioning Ductwork Heater Bank | Insulation Board | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 2 | - | Ceiling Space (inspected in Rooms 211, 228, 2Q1, 2Q4 during 2008 Inspections) | Air Conditioning Ductwork Heater Bank | Insulation Board | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 3 | - | Ceiling Space | Air Conditioning Ductwork Heater Bank | Insulation Board | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 553 | - | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554 | - | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554A | - | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554B | - | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554C | - | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 561 | - | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 562 | - | Floor Covering (suspected beneath carpet) | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 563 | - | Floor Covering (suspected beneath carpet) | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 564 | - | Floor Covering (suspected beneath floor covering) | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 565 | - | Floor Covering (beneath carpet) | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 567 | - | Floor Covering (beneath carpet) | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q7 | - | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q11 | Biolink | Floor Covering | Vinyl Floor Tiles (green coloured) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 252 | Biolink, North & East | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | - | Biolink, Throughout | Steel Beams | Insulation | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | - | Biolink,Throughout | Steel Beams | Insulation | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | - | Biolink, Throughout | Steel Beams | Insulation | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | - | Biolink, Throughout | Steel Beams | Insulation | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | - | Biolink, | Steel Beams | Insulation | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | - | Throughout | Steel Beams | Insulation | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 264 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 261 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 137B | Biolink, South & East | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | - | Biolink, | Steel Beams | Insulation | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 353 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17th November 2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 354A | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17th November 2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 355 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17th November 2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 356 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 360 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 353 | Biolink | Ceiling | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17th November 2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 354A | Biolink | Ceiling Tiles | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17th November 2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 355 | Biolink | Ceiling Tiles | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17th November 2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 356 | Biolink | Ceiling Tiles | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q9 | Biolink | Ceiling Tiles | Fibre Cement Sheeting | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 November 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552 | - | Ceiling Tiles | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearnce cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552A | - | Ceiling Tiles | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552B | West Section | Ceiling Tiles | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552C | West Section | Ceiling Tiles | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q11 | North, South, East & West | Walls | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 2 February 2022. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 1 | 1Q03 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 103 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 104 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 104A | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 104B | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 105 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 105A | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 105B | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 106 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 107 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 111A | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 111B | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 111C | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 111E | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 111F | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 111G | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 111H | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 112 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 113 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 101A | Central | Columns / Pylon | Moulded Fibre Cement | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 6 | 601 | North | Columns / Pylon | Moulded Fibre Cement | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 6 | 603 | North | Columns / Pylon | Moulded Fibre Cement | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | LG | LG22A | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | LG | LG23 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | LG | LG24 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | LG | LG24A | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | LG | LG24B | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G31 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G11 | - | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G11A | - | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G11B | - | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G13 | - | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G13A | - | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G13B | - | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G13C | - | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G06 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G07 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G37 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G38 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G39 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G48 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G49 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G49B | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G50 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G50A | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G52 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G53 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G53A | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G54 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G55 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G56 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G57 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G58 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G59 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G59A | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G59C | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G59D | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G59E | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G59F | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G59G | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G59H | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G60C | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G61 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G61A | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G61C | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G62 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G62B | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G62C | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G62D | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G62D1 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G62F | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G64B | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | GQ12 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | GQ14 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | GQ15 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | GQ18 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | GQ19 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | GQ20 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | GQ21 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | GQ22 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | GQ25 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 114 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 115 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 116 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 117 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 118 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 119 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 119A | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 120 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 121 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 122 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 129 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 130 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 131 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 132 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 133 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 133A | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 144 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 144A | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 145 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 145A | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 146 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 146A | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 148 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 149 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 150 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 151 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 152 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 155 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 156 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 157 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 158 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 158A | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 158B | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 159 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 159B | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 159C | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 159D | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 159E | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 159F | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 162 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 163 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 164 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q9 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q10 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q11 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q12 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q12 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q15 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q16 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q17 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 101A | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 101B | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 101C | Throughout | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 101C1 | Throughout | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 101C2 | Throughout | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 102 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 102A | Throughout | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 102B | Throughout | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 102C | Throughout | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 105 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | Item Removed. No removal/clearance documentation was provided. | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 106 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 107 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 108 | Throughout | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 113 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 135 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 137 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 137A | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 137B | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 137C | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 137D | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 138A | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 138B | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 138C | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 138D | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 139 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q18 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 210E | Toilet | Cubicle Partition Wall | Compressed Fibre Cement Sheet | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 225 | - | Floor Covering | Vinyl Tiles (grey colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 226 | - | Floor Covering | Vinyl Tiles (grey colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 226B | - | Floor Covering | Vinyl Tiles (grey colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 204 | - | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 205A | - | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 205B | - | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 205C | - | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 210A | - | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 211-220 | - | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 222 | - | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 223 | - | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 239 | - | Floor Covering | Vinyl Tiles (flexible dark blue colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 2Q5-2Q8 | - | Floor Covering | Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | 01 | 1Q2 | Exterior, North West Section, Eastern Side | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 101 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | G | G5 | Throughout | Floor Covering | Adhesive attached to Blue & Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | G | GQ7 | Cleaners Store Room | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | G | G4 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | G | G7 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 103 | Throughout | Floor Covering | Adhesive attached to Grey Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 105 | Throughout | Floor Covering | Adhesive attached to Grey Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 115 | Throughout | Floor Covering | Adhesive attached to Grey Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 107 | Throughout | Floor Covering | Adhesive attached to Light Green Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 201 | Throughout - Previously 201A & 201B | Floor Covering | Adhesive attached to Aqua &Grey Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 102 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 104 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 106 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 108 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 109 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 110 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 111, 111A, 111B | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 112 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 113 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 114 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 202 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 203 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 204 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 205 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 207 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 208 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 209 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 210 & 210A | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 211 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 212 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 213 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 214 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 302 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 303 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 309 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 314 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 305 | Throughout | Floor Covering | Adhesive attached to Light Green Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 405 | Throughout | Floor Covering | Adhesive attached to Light Green Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 505 | Throughout | Floor Covering | Adhesive attached to Light Green Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 606 | Throughout | Floor Covering | Adhesive attached to Light Green Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 407 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 410 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 410A & 410B | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 411 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 412 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 413 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 414 | Throughout | Floor Covering | Adhesive attached to Blue & Black Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 415 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG8 | Throughout | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG9 | Throughout | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG11 | Throughout | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG12 | Throughout | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG13 | Throughout | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | G | G5 | Throughout | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | G | G6 | Throughout | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | G | G7 | Throughout | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | G | G8 | Throughout | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 103-106 | Throughout | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 304 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 307 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 308 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 311 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 312 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 313 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 502 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 503 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 504 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 506 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 507 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 508 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 509 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 510 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 511 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 512 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 513 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 514 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Assumed Negative | - | - | - | - | Yes |
KENC | Kensington Campus | H13 | The Red Centre | G | - | Exterior, Northern Façade. Various Sections | Wall Cladding | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | LG | LG01-LG07 & LG40 | Throughout | Ceiling | Decorative Coating (vermiculite) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | LG | LG09A | Throughout | Floor Covering | Vinyl Tiles (off white colour) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q9 | Biolink, North, South, East & West | Walls | Fibre Cement Sheeting | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 November 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 448A | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 17/12/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 349A | Biolink, South. East & West | Walls | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 November 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 349C | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 349D | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350 | Biolink, Ceiling Space (E-W Partition Wall) | Walls | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 November 2021. | Yes |
KENC | Kensington Campus | F22 | Bank | 01 | 107 | Northern Campus Precinct - Store | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F22 | Bank | 01 | - | Exterior, North | Awning Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F22 | Bank | 02 | 205 | - | Floor Covering (under carpet tiles) | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F22 | Bank | 02 | 206 | - | Floor Covering (under carpet tiles) | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F22 | Bank | 2 | 2Q2 | - | Floor Covering (under carpet tiles) | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G17 | - | Ceiling | Sprayed Insulation (vermiculite) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 02 | 2Q2 | North Electrical Cupboard | Door Lining | Compressed Fibre Cement Sheet | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 03 | 3Q3 | Electrical Cupboard | Door Lining | Compressed Fibre Cement | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | G | GQ2 | Possibly Beneath Sheet Vinyl | Floor Covering | Vinyl Tiles (beige colour) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350 | Biolink, North, South, East & West | Walls | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 November 2021. | Yes |
Kenc | Kensington Campus | D9 | IO Myers Studio | G | G01B | Toilets | Partition Wall | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | G | G14A | - | Cubicle Partitions | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | 01 | 1Q1 | - | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | 01 | 1Q11 | - | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | G | A96 | Throughout | Cubicle Partitions | Compressed Fibre Cement | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | G | A95 | Windows | Infill Panels | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | C195 | Throughout | Cubicle Partitions | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | C199 | Throughout | Cubicle Partitions | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | B198A | Windows | Infill Panel | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | C194 | Windows | Infill Panel | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | C198 | Windows | Infill Panel | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | B298A | Windows | Infill Panels | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | C295 | Throughout | Cubicle Partitions | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 03 | C399 | Throughout | Cubicle Partitions | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
CCS | Cliffbrook Campus | CC4 | Building CC4 | G | G04 | - | Floor Covering | Vinyl Tiles (grey colour) | Negative | - | - | - | - | No |
CCS | Cliffbrook Campus | CC4 | Building CC4 | G | G05 | - | Floor Covering | Vinyl Tiles (grey colour | Assumed Negative | - | - | - | - | No |
CCS | Cliffbrook Campus | CC4 | Building CC4 | G | G06 | - | Floor Covering | Vinyl Tiles (grey colour) | Assumed Negative | - | - | - | - | No |
CCS | Cliffbrook Campus | CC4 | Building CC4 | G | G07 | - | Floor Covering | Vinyl Tiles (grey colour) | Assumed Negative | - | - | - | - | No |
CCS | Cliffbrook Campus | CC4 | Building CC4 | G | GQ1 | - | Floor Covering | Vinyl Tiles (grey colour) | Assumed Negative | - | - | - | - | No |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 01 | 115A | Toilet | Partition Wall | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | LG | LG2 | - | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | LG | LG2 | - | Wall | Vermiculite | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | LG | LG3 | - | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | LG | LG2 | - | Floor | Vermiculite | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | G9C | - | Within Electrical Cabinet | Electrical Backing Board | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | G14 | Exterior of G14 | Wall Cladding | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | G1A | - | Wall Linings | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | G1B | - | Wall Linings | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350A | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350B | Biolink, North, South & East | Walls | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 November 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350C | Biolink, North, South & East | Walls | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 November 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350D | Biolink, North & South | Walls | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 November 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 554 | East | Pipe Penetrations | Rope Packing Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 2 February 2022. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q10 | East | Pipe Penetration | Rope Packing Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 2 February 2022. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | R01 | Plant Room, West, Near SW Corner | Pipe Penetrations (suspected beneath sealant covering) | Rope Packing Insulation | Assumed Positive | Friable | Low | P3 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A contractor as part of a planned control program or prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450B | Biolink, | Pipe Penetrations | Rope Packing Insulation | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q7 | Biolink, | Pipe Penetration | Rope Packing Insulation (suspected beneath sealant covering) | Assumed Positive - removed | - | - | - | Item Removed. Refer Risktech Clearance Cert dated 17/11/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 449 | Biolink, | Pipe Penetrations | Rope Packing Insulation (suspected beneath sealant covering) | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 259 | Biolink | Fume Cupboard, Internal Lining | Fibre Cement Sheeting | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 13 October 2021. | Yes |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ1-GQ13 | Throughout | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G2 | Exterior | Wall Cladding | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | G | - | Exterior, Front Entrance | Column | Moulded Fibre Cement | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG1-LG67 & LGQ1-LGQ9 | Throughout | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | LGQ2 | Horizontal Window | Infill Panels | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | LGQ6 | Horizontal Window | Infill Panels | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG43 | Throughout Cleaner's Store | Floor Covering | Vinyl Floor Tiles (cream colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G1-G69 | Throughout | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ2 | Adjacent Window | Floor and Ceiling of Window Sill | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ8 | Adjacent Window | Floor and Ceiling of Window Sill | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ12 | Adjacent Window | Floor and Ceiling of Window Sill | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ1, GQ2, GQ4, GQ6, GQ7, GQ8, GQ10, GQ12 | Beneath Carpet | Floor Covering | Vinyl Floor Tiles (cream colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | LGQ4 | Throughout | Floor Covering | Vinyl Floor Tiles (grey colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ3, GQ5, GQ9, GQ11 | Suspected Under Sheet Vinyl | Floor Covering | Vinyl Floor Tiles (grey colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q2 | Adjacent Window | Floor and Ceiling of Window Sill | Fibre cement sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q6 | Adjacent Window | Floor and Ceiling of Window Sill | Fibre cement sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q12 | Adjacent Window | Floor and Ceiling of Window Sill | Fibre cement sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 101-171 | Throughout | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q1, 1Q2, 1Q4, 1Q6, 1Q7, 1Q8, 1Q10, 1Q12 | Under Carpet | Floor Covering | Vinyl Floor Tiles (cream colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q2 | Adjacent Window | Floor and Ceiling of Window Sill | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q8 | Adjacent Window | Floor and Ceiling of Window Sill | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q12 | Adjacent Window | Floor and Ceiling of Window Sill | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 201-214 & 216-251, 253, 255, 257, 259-282 | Throughout | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 252, 254, 256, 258 & 2Q2 | Above Set Ceiling | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q2 | Adjacent Window | Floor of Window Sill | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q6 | Adjacent Window | Floor of Window Sill | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q12 | Adjacent Window | Floor of Window Sill | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 301-31, 313-326, 328-356 & 358-372 | Throughout | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 01 | 1Q3 | Gymnasium (B5), East | Fire Door (tagged 'Fire Door Co. Pty Ltd, no date') | Core Insulation | Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 02 | 2Q1 | Gymnasium (B5), West | Fire Door (tagged 'Fire Door Co. Pty Ltd, no date') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 02 | 2Q2 | Gymnasium (B5), North | Fire Door (tagged 'Fire Door Co. Pty Ltd, no date') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 02 | 202 | Gymnasium (B5), Lift Motor Room | Fire Door (tagged 'Fire Door Co. Pty Ltd, no date') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 02 | 203 | Gymnasium (B5), South-East | Fire Door (tagged 'Fire Door Co. Pty Ltd, no date') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 01 | 1Q3 | Squash Courts (B7), Fire Stairs, West | Fire Door (tagged 'Fire Door Co. Pty Ltd, no date') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 01 | 1Q3 | Squash Courts (B7), Fire Stairs, East | Fire Door (no door tag) | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 02 | 2Q5 | Squash Courts (B7), East | Fire Door (tagged 'Fire Door Co. Pty Ltd, no date') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 02 | 2Q7 | Squash Courts (B7) | Fire Door (tagged 'Fire Door Co. Pty Ltd, no date') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 02 | 2Q2 | Gymnasium (B5), Throughout | Floor Covering | Vinyl Tiles (green colour) | Assumed Negative | - | - | - | - | No |
KENE | Kensington Environs | AS8 | 8 Arthur Street | G | - | Garage | Wall Lining | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R1 | Randwick R1 | G | G10 | - | Floor Covering | Vinyl Tiles (brown colour) | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R1 | Randwick R1 | G | G10A | - | Floor Covering | Vinyl Tiles (brown colour) | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R1 | Randwick R1 | G | G13 | - | Floor Covering | Vinyl Tiles (brown colour) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 353 | Biolink, | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17th November 2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 354A | Biolink, | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17th November 2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 355 | Biolink, | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17th November 2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 356 | Biolink, | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q9 | Biolink, | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 456 | Biolink, | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Restrict access to the ceiling space to authorised personnel. Remove under controlled conditions by a Class A/B contractor as part of a planned control program or prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q1, 1Q2, 1Q4, 1Q6, 1Q8, 1Q10, 1Q12 | Throughout | Ceiling | Vermiculite | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q02 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q03 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q04 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q05 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q07 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 201 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 201A | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 201B | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 201C | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 201D | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 201E | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 201F | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 201G | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 202 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 203 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 204 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 205 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 206 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 207 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 208 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 209 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 210 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 211 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 212 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 213 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 216 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 217 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 217A | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 217F | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 217G | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 217H | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 218 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 3Q02 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 304 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 306 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 307 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 308 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 309 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 310 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 311 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 312 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 02 | 2Q1 | Stairwell | Fire Door (tagged 'Wormald, no date') | Core Insulation | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAA | Block A | G | AG12 | Under Carpet | Floor Covering | Compressed Fibre Cement Sheet | Assumed Negative | - | - | - | - | No |
KENE | Kensington Environs | WR45 | 45 Wansey Road | G | - | Exterior, Entrance, East | Gable | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENE | Kensington Environs | WR45 | 45 Wansey Road | G | - | Throughout | Gable | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
FSW | Wellington Field Station | WFS23 | Wellington Field Station Administration | G | - | East Side | Awning Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552 | Ceiling Space | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Restrict access to the ceiling space to authorised personnel. Remove under controlled conditions by a Class A/B contractor as part of a planned control program or prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552A | Ceiling Space | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Restrict access to the ceiling space to authorised personnel. Remove under controlled conditions by a Class A/B contractor as part of a planned control program or prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552B | Ceiling Space | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Restrict access to the ceiling space to authorised personnel. Remove under controlled conditions by a Class A/B contractor as part of a planned control program or prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552C | Ceiling Space | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Restrict access to the ceiling space to authorised personnel. Remove under controlled conditions by a Class A/B contractor as part of a planned control program or prior to demolition or refurbishment. | No |
FSSL | Smiths Lake Field Station | SL6 | Smiths Lake COLA | G | G01 | - | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554A | Ceiling Space | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Restrict access to the ceiling space to authorised personnel. Remove under controlled conditions by a Class A/B contractor as part of a planned control program or prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 555 | Ceiling Space | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Restrict access to the ceiling space to authorised personnel. Remove under controlled conditions by a Class A/B contractor as part of a planned control program or prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 562 | Ceiling Space | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Restrict access to the ceiling space to authorised personnel. Remove under controlled conditions by a Class A/B contractor as part of a planned control program or prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 563 | Ceiling Space | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Restrict access to the ceiling space to authorised personnel. Remove under controlled conditions by a Class A/B contractor as part of a planned control program or prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 564 | Ceiling Space | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Restrict access to the ceiling space to authorised personnel. Remove under controlled conditions by a Class A/B contractor as part of a planned control program or prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 565 | Ceiling Space | Debris | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Restrict access to the ceiling space to authorised personnel. Remove under controlled conditions by a Class A/B contractor as part of a planned control program or prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R1 | Randwick R1 | G | G27 | Under New Vinyl Floor Sheet | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
MANV | Manly Vale | MV7 | Laboratory 4 | G | - | Toilet | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q01 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | - | Exterior, North Side, Outside Room 210A, & 210B Left Side Windows | Windows (between frame and pane) | Mastic Sealant | Negative | - | - | - | - | No |
KENC | Kensington Campus | J12 | Newton | R | RQ03 | Roof Area | Roof Covering | Bituminous Membrane | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 3Q1 | Electrical Cupboard | HV Electrical Cable | Bituminous Wrap Material | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 4Q1 | Electrical Cupboard | HV Electrical Cable | Bituminous Wrap Material | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 5Q1 | Electrical Cupboard | HV Electrical Cable | Bituminous Wrap Material | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 6Q1 | Electrical Cupboard | HV Electrical Cable | Bituminous Wrap Material | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 7Q1 | Electrical Cupboard | HV Electrical Cable | Bituminous Wrap Material | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1623 | Former Room 1623 | Floor Covering | Vinyl Floor Tiles (beige colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | G | BG86 | Exterior, East Side | Infill Panels | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 566 | Ceiling Space | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Restrict access to the ceiling space to authorised personnel. Remove under controlled conditions by a Class A/B contractor as part of a planned control program or prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | C15 | White House | 01 | - | Balcony, North and West | Flooring | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | - | Pool (B4), Exterior, North, Chemical Storage Shed | Wall Cladding | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | G | G09 | Male Bathroom | Wall Linings | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | G | G09A | Male Bathroom | Wall Linings | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | G | G10A | Female Bathroom | Wall Linings | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | G | G11 | Change Room adjacent Female Bathroom | Wall Linings | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | G | G11A | Change Room adjacent Female Bathroom | Wall Linings | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 567 | Ceiling Space | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Restrict access to the ceiling space to authorised personnel. Remove under controlled conditions by a Class A/B contractor as part of a planned control program or prior to demolition or refurbishment. | No |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | - | Exterior, West Entrance | Flooring | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | - | Exterior, East Side, Adjacent Water Tank | Low Level Wall Panelling | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 137 | Biolink | On Concrete Floor Slab (suspected beneath black linoleum and tiles) | Bituminous Adhesive | Assumed Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 137A | Biolink | On Concrete Floor Slab (suspected beneath black linoleum and tiles) | Bituminous Adhesive | Assumed Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 137C | Biolink | On Concrete Floor Slab (suspected beneath black linoleum and tiles) | Bituminous Adhesive | Assumed Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 137D | Biolink | On Concrete Floor Slab (suspected beneath black linoleum and tiles) | Bituminous Adhesive | Assumed Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 137E | Biolink | On Concrete Floor Slab (suspected beneath black linoleum and tiles) | Bituminous Adhesive | Assumed Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q9 | Biolink | On Concrete Floor Slab (beneath vinyl floor tiles) | Bituminous Adhesive | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 November 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 448 | Biolink | On Concrete Floor Slab (beneath tiles) | Adhesive | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 448B | Biolink | On Concrete Floor Slab (beneath vinyl floor tiles) | Adhesive | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 December 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 449 | Biolink | On Concrete Floor Slab (beneath tiles) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450 | Biolink | On Concrete Floor Slab (suspected beneath new floor covering) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450A | Biolink | On Concrete Floor Slab (suspected beneath new floor covering) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
KENE | Kensington Environs | AS4 | 4 Arthur Street | G | - | Exterior, Surrounding | Eaves | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | 1Q1 | West End of Corridor | Fire Door (tagged 'Wormald, 198_') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | 1Q4 | West End of Corridor | Fire Door (tagged 'Wormald, 198_') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | 2Q1 | East and West | Fire Door (tagged 'Wormald, 198_') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | 2Q4 | West End of Corridor | Fire Door (tagged 'Wormald, 198_') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 03 | 3Q1 | East End of Corridor | Fire Door (tagged 'Wormald, 198_') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | G34 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450B | Biolink | On Concrete Floor Slab (suspected beneath new floor covering) | Adhesive | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450C | Biolink | On Concrete Floor Slab (beneath tiles) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | MLG Q02 | Northern Service Tunnel, Western End | Air Conditioning Ductwork Heater Unit | Millboard Insulation Board | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 6 | 6Q01 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 6 | 610 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 6 | 622 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 6 | 623 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 6 | 624 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 6 | 625 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 4Q02 | Communications Riser Cupboard | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 4Q02 | - | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 4Q05 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401A | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401B | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401C | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401D | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401E | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401F | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401G | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401H | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401I | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401J | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401K | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 402 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 403 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 405 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 406 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 407 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 408 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 409 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 410 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 412 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 412A | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 412B | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 412C | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 412D | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 412E | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 5Q03 | Under Carpet | Floor Covering | Vinyl Floor Tiles | Assumed Negative | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501A | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501B | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501C | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501D | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501E | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501F | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501G | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501H | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501I | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501J | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501K | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501L | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501M | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 502 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 503 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 504 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 505 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 506 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 507 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 508 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 510 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 510A | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 510B | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 510C | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 510D | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 144 | - | Wall | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 140 | - | Fire Door (tagged 'Bismac, 2002') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 145A | - | Fire Door (tagged 'Bismac, 2013') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 156 | East | Fire Door (tagged 'Bismac, 2012') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 177 | South | Fire Door (tagged 'Bismac, 2021') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 179 | Sprinkler Pump Room | Fire Door (no tag) | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 182 | North, Ducts x 2 | Fire Doors (tagged 'Bismac, 2021') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q1 | - | Fire Door (tagged 'Bismac, 2006') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q3 | - | Fire Door (tagged 'Australasian, 2002') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q6 | - | Fire Door (tagged 'Bismac, 2006') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q8 | - | Fire Door (tagged 'TDF, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q10 | West | Fire Door (tagged 'Bismac, 2013') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q11 | North | Fire Door (not tag) | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q13 | - | Fire Door (tagged 'TDF, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q25 | Service Duct Entry | Fire Door (no tag) | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q3 | - | Fire Doors (tagged 'Bismac, 2021') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q8 | - | Fire Door (tagged 'Bismac, 2002') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q9 | - | Fire Doors (tagged 'TDF, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q10 | - | Fire Door (tagged 'Bismac, 2000') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | M2Q02 | Service Duct off Room 2Q27 | Fire Door (tagged 'Bismac, 2021) | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q4 | - | Fire Door (tagged 'TDF, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q7 | - | Fire Doors (tagged 'Bismac, 2002') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q8 | - | Fire Door (tagged 'Bismac, 2005') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q10 | - | Fire Door (tagged 'TDF, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q12 | - | Fire Door (tagged 'Bismac, 2005') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q14 | - | Fire Door (tagged 'Wormald, 20--') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | M3Q02 | Service Duct off Room 3Q19 | Fire Door (tagged 'Bismac, 2021') | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q4 | - | Fire Door (no tag) | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q6 | - | Fire Door (tagged 'Bismac Fire Doors, 2021') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q8 | - | Fire Door (tagged 'Hume Doors, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 625 | Service Duct | Fire Door (tagged 'TDF, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 6Q2 | - | Fire Door (tagged 'Bismac Fire Doors, 2023') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 6Q3 | - | Fire Door (tagged 'Bismac, 2003') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 730 | Service Duct Entry off Room 730 | Fire Door (tagged 'TDF, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 7Q2 | - | Fire Door (tagged 'Hume Doors, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 7Q3 | - | Fire Door (tagged 'Hume Doors, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 7Q9 | Plant Room | Fire Doors (tagged ' Bismac Fire Doors, 2021') | Core Insulation | Assumed Negative | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 837 | Service Duct Entry | Fire Doors (no tag) | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 838 | - | Fire Doors (no tag) | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 8Q1 | - | Fire Door (no tag) | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 8Q6 | - | Fire Door (no tag) | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 930 | Service Duct Entry | Fire Door (tagged 'TDF, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 9Q2 | - | Fire Door (tagged 'Bismac, 20--') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 9Q3 | - | Fire Door (tagged 'Bismac, 20--') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1026 | Service Duct Entry | Fire Door (tagged 'TDF, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 10Q2 | - | Fire Door (tagged 'Hume Doors, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 10Q3 | - | Fire Door (tagged 'Hume Doors, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1126 | Service Duct Entry | Fire Door (tagged 'TDF, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 11Q2 | - | Fire Door (tagged 'Hume Doors, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 11Q3 | - | Fire Door (tagged 'Hume Doors, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1227 | Service Duct Entry | Fire Door (tagged 'TDF, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1228 | - | Fire Door (tagged 'Bismac, 2011') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 12Q2 | - | Fire Door (tagged 'Hume Doors, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 12Q3 | - | Fire Door (tagged 'Hume Doors, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1326 | Service Duct Entry off Room 1326 | Fire Door (tagged 'TDF, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 13Q2 | - | Fire Door (tagged 'Hume Doors, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 13Q3 | - | Fire Door (tagged 'Hume Doors, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 1428 | Service Duct Entry off Room 1428 | Fire Door (tagged 'TDF, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 1429 | - | Fire Door (tagged ' Bismac Fire Door, 2021') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 14Q2 | - | Fire Door (tagged 'Hume Doors, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 14Q3 | - | Fire Door (tagged 'Hume Doors, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 15Q2 | - | Fire Door (tagged 'Bismac, 20--') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 15Q3 | - | Fire Door (tagged 'Bismac, 20--') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | M15Q 01 | Service Duct Entry off Room 15Q8, Toilets | Fire Door (tagged 'Bismac, 2021') | Core Insulation | Assumed Negative | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | M15Q 02 | Service Duct Adjacent Room 1502A | Fire Door (tagged 'Bismac, 20--') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1629 | Duct Entry | Fire Door (tagged 'TDF, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 16Q1 | - | Fire Door (tagged 'Bismac Fire Doors, 2019') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 16Q2 | Fire Door (tagged 'Hume Doors, 2015') | Core Insulation | Not Sampled - New Appearance | - | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 16Q3 | - | Fire Door (tagged 'Hume Doors, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 17 | 1701 | - | Fire Door (tagged 'Bismac, 2013') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 17 | 1702 | - | Fire Door (tagged 'TDF, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 17 | 1704 | - | Fire Door (tagged 'Bismac, 2013') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 18 | 1801 | - | Fire Door (tagged 'Bismac, 2005') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 18 | 1803 | - | Fire Door (tagged 'TDF, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1201 - 1226 | - | Panel Above Doors | Solid Timber | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1301 - 1316 | - | Panel Above Doors | Solid Timber | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1601 - 1607 & 1609 - 1612 | - | Panel Above Doors | Solid Timber | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G7 | - | Ceiling | Decorative Vermiculite Coating (on metal) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G13 | - | Ceiling | Decorative Vermiculite Coating (on metal) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G9 | East & West | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G10 | East & West | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G15 | - | Wall | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G18 | - | Wall | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G21 | - | Wall | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENE | Kensington Environs | O14 | Kangas House | G | 1 | - | Floor Covering | Vinyl Floor Tiles (light brown colour - beneath other floor coverings) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G2 | - | Floor Covering | Adhesive Beneath Vinyl Floor Tiles & Floor Surface | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G3 | - | Floor Covering | Adhesive Beneath Vinyl Floor Tiles & Floor Surface | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G4 | - | Floor Covering | Adhesive Beneath Vinyl Floor Tiles & Floor Surface | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G5 | - | Floor Covering | Adhesive Beneath Vinyl Floor Tiles & Floor Surface | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G6 | - | Floor Covering | Adhesive Beneath Vinyl Floor Tiles & Floor Surface | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G7 | - | Floor Covering | Adhesive Beneath Vinyl Floor Tiles & Floor Surface | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G13 | - | Floor Covering | Adhesive Beneath Vinyl Floor Tiles & Floor Surface | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G16 | - | Floor Covering | Adhesive Beneath Vinyl Floor Tiles & Floor Surface | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G23 | - | Floor Covering | Adhesive Beneath Vinyl Floor Tiles & Floor Surface | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G25 | - | Floor Covering | Adhesive Beneath Vinyl Floor Tiles & Floor Surface | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G6 | Blockhouse | G | G8B | - | Floor Covering | Vinyl Floor Tiles (black colour) | Assumed Negative | - | - | - | - | No |
KENE | Kensington Environs | O14 | Kangas House | G | 4 | - | Floor Covering | Vinyl Floor Tiles (dark brown colour - beneath other floor coverings) | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450D | Biolink | On Concrete Floor Slab (suspected beneath new floor covering) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
KENC | Kensington Campus | F21 | Library | 3 | 3Q11 | Fire Stairs | Floor Covering (beneath carpet) | Vinyl Floor Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | G | G8 | Throughout | Floor Covering | Adhesive attached to Green Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | G | G6 | Throughout | Floor Covering | Adhesive attached to Green Vinyl Tiles | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450E | Biolink | On Concrete Floor Slab (beneath tiles) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
KENE | Kensington Environs | O14 | Kangas House | G | - | Exterior, Eastern Building, South Side (Outside Room 63) | Awning Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G6 | Blockhouse | - | - | Roof, Western End, Plant Room (Air Handling Unit) | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | No |
KENC | Kensington Campus | G6 | Blockhouse | - | - | Exterior | Wall Expansion Joints | Sealant Mastic | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450F | Biolink | On Concrete Floor Slab (beneath tiles) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450G | Biolink | On Concrete Floor Slab (suspected beneath new floor covering) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 455A | Biolink | On Concrete Floor Slab (beneath tiles) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
KENE | Kensington Environs | BS22 | Tiggers Place | G | G55A | South & West | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENE | Kensington Environs | BS22 | Tiggers Place | G | G22 | Northern Side of Site, Shed | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENE | Kensington Environs | BS22 | Tiggers Place | G | G70 | Northern Side of Site, Shed | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENE | Kensington Environs | BS22 | Tiggers Place | G | - | External, Southern Verandah Adjacent G01 to G56 | Awning Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENE | Kensington Environs | BS22 | Tiggers Place | G | - | External, Verandah Adjacent G05 & G11 | Awning Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENE | Kensington Environs | BS22 | Tiggers Place | G | - | External, Verandah Adjacent G52 & G54 | Awning Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENE | Kensington Environs | BS22 | Tiggers Place | G | - | External, Adjacent G05 & G11, Below Windows | Infill Wall Panels | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 2Q7 | - | Floor Covering | Vinyl Tiles (flexible blue colour) | Assumed Negative (Removed) | - | - | - | - | Yes |
KENC | Kensington Campus | E6 | Roundhouse | G | Former Room G04B | Throughout | Wall Lining | Fibre Cement Sheeting | Assumed Negative - Removed | - | - | - | - | Yes |
KENC | Kensington Campus | E6 | Roundhouse | 01 | Former Rooms 107B, 111, 112, 113 | Under Grey Carpet | Floor Covering | Vinyl Tiles (black colour) | Assumed Negative - Removed | - | - | - | ' | Yes |
KENC | Kensington Campus | E6 | Roundhouse | 01 | 1Q1 | Throughout, Perimeter Surrounding | Railing | Fibre Cement Sheeting | Assumed Negative - Removed | - | - | - | - | Yes |
KENC | Kensington Campus | K14 | Physics Theatre | LG | LG15 | - | Floor Covering | Vinyl Tiles (green colour) | Removed - Positive (chrysotile) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 20 April 2021. | Yes |
KENC | Kensington Campus | K14 | Physics Theatre | LG | LGQ13 | - | Floor Covering | Vinyl Tiles (green colour) | Removed - Assumed Positive | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 20 April 2021. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 731 | - | Fire Panel Above Door | Core Insulation | Assumed Positive | Friable | Low | P3 | Remove fire panel by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 837 | - | Fire Panel Above Door | Core Insulation | Assumed Positive | Friable | Low | P3 | Remove fire panel by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 838 | - | Fire Panel Above Door | Core Insulation | Assumed Positive | Friable | Low | P3 | Remove fire panel by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 917 | - | Fire Panel Above Door | Core Insulation | Assumed Positive | Friable | Low | P3 | Remedial works should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 930 | - | Fire Panel Above Door | Core Insulation | Assumed Positive | Friable | Low | P3 | Remove fire panel by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 931 | - | Fire Panel Above Door | Core Insulation | Assumed Positive | Friable | Low | P3 | Remove fire panel by a Class A Contractor within a planned control program. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q6 | Biolink | On Concrete Floor Slab (beneath vinyl floor tiles) | Adhesive | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 December 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 551 | - | On Concrete Floor Slab (beneath tiles) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 551A | - | On Concrete Floor Slab (beneath tiles) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552 | - | On Concrete Floor Slab (suspected beneath carpet) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552A | - | On Concrete Floor Slab (suspected beneath carpet) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 552B | - | On Concrete Floor Slab (suspected beneath carpet) | Bituminous Adhesive | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 2 February 2022. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552C | - | On Concrete Floor Slab (suspected beneath carpet) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 553 | - | On Concrete Floor Slab (beneath tiles) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554 | - | On Concrete Floor Slab (beneath tiles) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer Risktech clearane cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554A | - | On Concrete Floor Slab (beneath tiles) | Adhesive | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554B | - | On Concrete Floor Slab (beneath tiles) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554C | - | On Concrete Floor Slab (beneath tiles) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 561 | - | On Concrete Floor Slab (beneath tiles) | Bituminous Adhesive | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 562 | - | On Concrete Floor Slab (suspected beneath tiles & carpet) | Adhesive | Removed | Friable | Low | - | Item Removed: Refer to RiskTech Clearance Certificate dated 20200321. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 563 | - | On Concrete Floor Slab (suspected beneath tiles & carpet) | Adhesive | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 564 | - | On Concrete Floor Slab (suspected beneath floor covering) | Adhesive | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 565 | - | On Concrete Floor Slab (beneath tiles & carpet) | Adhesive | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 567 | - | On Concrete Floor Slab (beneath tiles & carpet) | Adhesive | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q7 | - | On Concrete Floor Slab (beneath tiles) | Adhesive | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q8 | - | On Concrete Floor Slab (suspected beneath carpet & tiles) | Adhesive | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q11 | Biolink | On Concrete Floor Slab (beneath tiles) | Adhesive | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 2 February 2022. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 456 | Biolink | Ceiling Tiles (except northern section) | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 456 | Biolink | Fire Door (tagged 'Masterbilt') | Insulation Core | Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 20200321. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 551 | - | Fire Door (no tag) | Insulation Core | Removed | Friable | Low | - | Item Removed: Refer to RiskTech Clearance Certificate dated 20200321. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552 | - | Fire Door (no tag) | Insulation Core | Removed | Friable | Low | - | Item Removed: Refer to RiskTech Clearance Certificate dated 20200321. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 553 | - | Fire Door (no tag) | Insulation Core | Removed | Friable | Low | - | Item Removed: Refer to RiskTech Clearance Certificate dated 20200321. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 560 | - | Fire Door (no tag) | Insulation Core | Removed | Friable | Low | - | Item Removed: Refer to RiskTech Clearance Certificate dated 20200321. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 561 | - | Fire Door (no tag) | Insulation Core | Removed | Friable | Low | - | Item Removed: Refer to RiskTech Clearance Certificate dated 20200321. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 562 | - | Fire Door (no tag) | Insulation Core | Removed | Friable | Low | - | Item Removed: Refer to RiskTech Clearance Certificate dated 20200321. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 563 | - | Fire Door (no tag) | Insulation Core | Removed | Friable | Low | - | Item Removed: Refer to RiskTech Clearance Certificate dated 20200321. | - |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 564 | - | Fire Door (no tag) | Insulation Core | Removed | Friable | Low | - | Item Removed: Refer to RiskTech Clearance Certificate dated 20200321. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 565 | - | Fire Door (no tag) | Insulation Core | Removed | Friable | Low | - | Item Removed: Refer to RiskTech Clearance Certificate dated 20200321. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q11 | - | Fire Door (no tag) | Insulation Core | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 2 February 2022. | Yes |
KENE | Kensington Environs | BS34 | Bio Sciences North | G | G21A | - | Ceiling | Fibre Cement Sheeting | Removed - Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 4 November 2019. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 130 | Biolink, | Walls (East and South side) | Fibre Cement Sheeting | Removed | Item Removed: Refer to RiskTech Clearance Certificate dated 20201030 | Yes | |||
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 131 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Seal damaged areas to walls in ceiling space. Remediate under controlled conditions by a Class A/B contractor as part of a planned control program or remove prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G22 | Biolink, | Air Conditioning Ductwork - Flange Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 254 | Biolink | Air Conditioning Ductwork - Flange Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q7 | Biolink | Air Conditioning Ductwork - Flange Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q7 | Biolink | Air Conditioning Ductwork - Flange Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q10 | - | Air Conditioning Ductwork - Flange Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G20 | Biolink, Ceiling Space, West Wall | Pipe Penetrations | Rope Packing Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 10 September 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | - | Biolink, Throughout | Old Air Conditioning Ductwork - Flange Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | - | Biolink, Throughout | Old Air Conditioning Ductwork - Flange Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | - | Biolink, Throughout | Old Air Conditioning Ductwork - Flange Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | - | Biolink, Throughout | Old Air Conditioning Ductwork - Flange Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | - | Biolink, | Old Air Conditioning Ductwork - Flange Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | - | Biolink, Throughout (except Room 4Q7) | Old Air Conditioning Ductwork - Flange Joints | Sealant Mastic | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 December 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | - | Biolink, Throughout (except Room 5Q10) | Old Air Conditioning Ductwork - Flange Joints | Sealant Mastic | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 2 February 2022. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q12 | Biolink, East (common to north section of Room 142) & West (common to Room 130) | Walls | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 30 October 2020. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 256 | Biolink | Ceiling Tiles | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktach Clearance cert dated 13/10/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 241 | Biolink, | On Concrete Floor Slab (suspected beneath floor covering) | Bituminous Adhesive | Assumed Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 252 | Biolink, Former Room 251 | On Concrete Floor Slab (suspected beneath floor covering) | Bituminous Adhesive | Assumed Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 260 | Biolink | On Concrete Floor Slab (beneath floor covering) | Adhesive | Removed | - | - | - | Item removed. Refer Risktech Clearance cert dated 13/10/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 272 | Biolink | On Concrete Floor Slab (beneath carpet) | Adhesive | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 340 | Biolink | Fire Door | Insulation Core | Removed | Friable | Low | - | Item Removed: Refer to RiskTech Clearance Certificate dated 20200321. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 458 | Biolink | Fire Door | Insulation Core | Removed | Friable | Low | - | Item Removed: Refer to RiskTech Clearance Certificate dated 20200321. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | - | Biolink, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G20 | Biolink, Perimeter Façade Walls (behind concrete wall section & behind infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G21 | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G23 | Biolink, South, Perimeter Façade Walls, (behind removed wall sheeting) | Spandrel Brackets x 7 | Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 10 September 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G23A | Biolink, Perimeter Façade Walls (behind concrete wall sections & behind infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G23B | Biolink, Perimeter Façade Walls (behind concrete wall section & behind infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G27 | Biolink, Perimeter Façade Walls (behind concrete wall sections & behind infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G27A | Biolink, Perimeter Façade Walls (behind concrete wall sections & behind infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G29 | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G29A | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | - | Biolink, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 130 | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 131A | Biolink, West, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer RiskTech Clearance cert dated 28/09/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 132 | Biolink, Perimeter Façade Walls (behind concrete wall sections & behind infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 137 | Biolink, Perimeter Façade Walls (behind concrete wall sections & behind infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 137A | Biolink, Perimeter Façade Walls (behind concrete wall sections & behind infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 137B | Biolink, Perimeter Façade Walls (behind concrete wall sections & behind infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 138 | Biolink, Perimeter Façade Walls (behind concrete wall sections & behind infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 138A | Biolink, South, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 138B | Biolink, South, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 141A | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 141B | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 142 | Biolink, Perimeter Façade Walls (behind concrete wall sections & behind infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 143 | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | - | Biolink, Perimeter Façade Walls (behind concrete wall sections & behind infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 241 | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 241D | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 256 | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 257 | Biolink, South & East, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer Risktech Clearance cert dated 13/10/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 258 | Biolink, South, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer Risktech Clearance cert dated 13/10/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 259 | Biolink, South, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer Risktech Clearance cert dated 13/10/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 262 | Biolink, South & West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 263A | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 263B | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 263C | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 263D | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 264 | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 272 | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | - | Biolink, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 343 | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance cert dated 17/11/2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 343A | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 347 | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 349 | Biolink, South, Perimeter Façade Walls (behind removed wall panelling | Spandrel Brackets | Insulation | Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 November 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 349D | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350 | Biolink, South, Perimeter Façade Walls (behind removed wall panelling) | Spandrel Brackets | Insulation | Removed-Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 November 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350A | Biolink, South & West, | Spandrel Brackets | Insulation | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021 | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 220 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | SST1 | Main Service Tunnel | G | - | Throughout, Main Service Tunnel | Old Gas Pipe Work Flange Joints | Gaskets | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350B | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350C | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350D | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 352 | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 353 | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | G | GQ03 | Communications Riser Cupboard, On Top of Blockwork South Wall & Residue on Brown Timber Strip Panel Attached to South Wall | Packing Material | Insulation | Removed - Positive (Amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 12 &16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 1 | 1Q02 | Communications Riser Cupboard, Inside Pipe Conduits (~30mm diameter x 6 pipes) | Packing Material | Insulation | Removed - Positive (Amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 6 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q03 | Communications Riser Cupboard, On Top of Blockwork South Wall | Packing Material | Insulation | Removed - Assumed Positive | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 2 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 3 | 3Q01 | Fire Hose Reel Cupboard | Packing Material | Insulation | Removed | - | - | - | Item removed. See Risktech clearance cert dated 20210616 | Yes |
KENC | Kensington Campus | K17 | Building K17 | 3 | 3Q02 | Communications Risers | Packing Material | Insulation | Removed | - | - | - | Item removed. See Risktech clearance cert dated 20210616 | Yes |
KENC | Kensington Campus | K17 | Building K17 | 6 | 6Q01 | Communications Riser | Packing Material | Insulation | Removed | - | - | - | Item removed. Refer RiskTech Clearance Certificate 20210616 | Yes |
KENC | Kensington Campus | K17 | Building K17 | 6 | 6Q01 | Ceiling Adjacent Fire Hose Reel Cupboard | Packing Material | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 7 | 7Q02 | Corridor Adjacent Lift Motor Room | Packing Material | Insulation | Removed | - | - | - | Item removed. Refer RiskTech Clearance Certificate 20210616 | Yes |
KENC | Kensington Campus | K17 | Building K17 | 7 | 7Q02 | Hallway Adjacent Lift Motor Room | Remnants on West Wall Adjacent to Block Work | Insulation | Removed | - | - | - | Item removed. Refer RiskTech Clearance Certificate 20210616 | Yes |
KENC | Kensington Campus | K17 | Building K17 | 7 | 7Q01 | Fire Stairwell | Packing Material | Insulation | Assumed negative, refer Risktech report Nov 2020, not on list | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 7 | 7Q02 | Hallway Adjacent Lift Motor Room | Packing Material Remnants | Insulation | Removed | - | - | - | Item removed. Refer RiskTech Clearance Certificate 20210616 | Yes |
KENC | Kensington Campus | J12 | Newton | G | G12A | - | Wall Lining | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J12 | Newton | 1 | 1Q5 | Duct Riser | Duct Work Joints | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J12 | Newton | 2 | 2Q5 | Duct Riser | Duct Work Joints | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | Yes |
KENC | Kensington Campus | J12 | Newton | 3 | 302A | Plant Room | Toilet Exhaust Duct Work Joints | Mastic Sealant | Removed | Item removed, refer to clearance certfiicate dated 20210501 | Yes | |||
KENC | Kensington Campus | J12 | Newton | 3 | 3Q3 | Duct Riser | Duct Work Joints | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J12 | Newton | R | RQ01 | Duct Riser | Duct Work Joints | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | HS46 | 46 High Street | 1-03 | - | Exterior Facade Note: May be present to other height restricted areas | Expansion Joints | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 354A | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | G | G08F | Communications Riser Cupboard | Fire Door (no tag) | Core Insulation | Removed - Positive (chrysotile & amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 19 December 2021. | Yes |
KENC | Kensington Campus | G27 | AGSM | 2 | 208 | Communications Riser Cupboard (Room C2Q02) | Fire Door (no tag) | Core Insulation | Removed - Positive (chrysotile & amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 19 December 2021. | Yes |
KENC | Kensington Campus | G27 | AGSM | 3 | 321 | Communications Riser Cupboard (Room CQ301) | Fire Door (no tag) | Core Insulation | Removed - Positive (chrysotile & amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 19 December 2021. | Yes |
FSW | Wellington Field Station | WFS2 | Wellington Field Station Shearing Shed | G | G01 | West Side, SW Corner Room - North Wall | Electrical Panel | Electrical Backing Board | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS2 | Wellington Field Station Shearing Shed | G | G01 | Shearing Area, East Side, NE Corner | Electrical Panel | Electrical Backing Board | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS1 | Wellington Field Station Cottage | G | 1 | Main Residence, Exterior, South Side, South East | Infill Wall Panelling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS1 | Wellington Field Station Cottage | G | 1 | Main Residence, Exterior, South Side, South East | Window Infill Panelling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS1 | Wellington Field Station Cottage | G | 1 | Main Residence, East Room - Sunroom | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS1 | Wellington Field Station Cottage | G | 2 | Laundry, Exterior, All Sides | Walls | Profiled Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Repair/seal the localised damage areas to the wall sheeting under controlled conditions within a planned control program. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS1 | Wellington Field Station Cottage | G | 2 | Laundry, Exterior, All Sides | Eaves | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS1 | Wellington Field Station Cottage | G | 2 | Laundry | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS8 | Hay Field Station - Managers Office | G | - | Exterior, Sub-Floor Space | On Top of Piers, Packing | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q5 | Electrical Cupboard | Above, Within & Suspected Beneath Floor Slab - Conduits | Moulded Fibre Cement Pipes | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q10 | - | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 183 | - | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | M2Q02 | Service Duct off Room 2Q27 | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | M3Q02 | Service Duct off Room 3Q19 | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | M4Q01 | Service Duct off Room 4Q5 | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 520 | Service Duct Entry off Room 520 | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q10 | Service Duct off Room 5Q10, Toilets | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 618 | Service Duct off Room 618 | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 625 | Service Duct | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 730 | Service Duct off Room 730 | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 7Q7 | Service Duct off Room 7Q7, Toilets | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 837 | Service Duct off Room 837 | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 8Q10 | Service Duct off Room 8Q10, Toilets | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 923 | Service Duct off Room 923, Toilets | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 930 | Service Duct off Room 930 | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1026 | Service Duct off Room 1026 | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 10Q7 | Service Duct off Room 10Q7, Toilets | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1126 | Service Duct off Room 1126 | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 11Q7 | Service Duct off Room 11Q7, Toilets | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1221 | Service Duct off Room 1221, Toilets | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1227 | Service Duct off Room 1227 | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1326 | Service Duct off Room 1326 | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 13Q9 | Service Duct off Room 13Q9, Toilets | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 1428 | Service Duct off Room 1428 | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 14Q7 | Service Duct off Room 14Q7, Toilets | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | M15Q 01 | Service Duct off Room 15Q8, Toilets | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | M15Q 02 | Service Duct Adjacent Room 1502A | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1620 | Service Duct off Room 1620, Toilets | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1629 | Duct Adjacent Room 1629 | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1228 | - | Fire Panel Above Door | Core Insulation | Removed - Assumed Positive (amosite) | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 1 May 2020. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1326 | - | Fire Panels Above Door | Core Insulation | Assumed Positive | Friable | Low | P3 | Remedial works should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1327 | - | Fire Panels Above Door | Core Insulation | Assumed Positive | Friable | Low | P3 | Remedial works should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 1428 | - | Fire Panel Above Door | Core Insulation | Assumed Positive | Friable | Low | P3 | Remove fire panel by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 1429 | - | Fire Panel Above Door | Core Insulation | Assumed Positive | Friable | Low | P3 | Remove fire panel by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1628 | Former Room 1628 & 1629 | Fire Panels Above Door | Core Insulation | Removed - Positive (amosite) | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 1 May 2020. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1026 | - | Fire Panel Above Door | Core Insulation | Assumed Positive | Friable | Low | P3 | Remove fire panel by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1126 | - | Fire Panel Above Door | Core Insulation | Assumed Positive | Friable | Low | P3 | Remove fire panel by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1127 | - | Fire Panel Above Door | Core Insulation | Assumed Positive | Friable | Low | P3 | Remove fire panel by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 623 | - | Fire Panel Above Door | Core Insulation | Assumed Positive | Friable | Low | P3 | Remove fire panel by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 624 | - | Fire Panel Above Door | Core Insulation | Assumed Positive | Friable | Low | P3 | Remove fire panel by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F21 | Library | LG | - | Old Northern Building Section, Throughout | Within Wall Cavities & Voids and On Soffit Above Brick Walls & Services | Insulation Residue & Debris | Assumed Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | 122B | Cleaners Room | On Soffit Surrounding Column | Insulation Residue & Bituminous Coating (adhesive) | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 25 May 2000. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | E1Q01 | Electrical Room off Fire Stairs (1Q12) | On Soffit Surrounding Column | Suspected Insulation Residue & Bituminous Coating (beneath new insulation board) | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | Yes |
KENC | Kensington Campus | F21 | Library | 2 | 216 | Electrical Room Adjacent Fire Stairs (2Q4) | On Soffit Surrounding Column | Insulation Residue & Bituminous Coating (adhesive) | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 25 May 2000. | Yes |
KENC | Kensington Campus | F21 | Library | 2 | 242 | Electrical Room Adjacent Fire Stairs (2Q16) | On Soffit Surrounding Column | Insulation Residue & Bituminous Coating (adhesive) | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 25 May 2000. | Yes |
KENC | Kensington Campus | F21 | Library | 2 | 243 | Cleaners Room | On Soffit Surrounding Column | Insulation Residue & Bituminous Coating (adhesive) | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 25 May 2000. | Yes |
KENC | Kensington Campus | F21 | Library | 2 | - | Old Northern Building Section, Throughout | Within Wall Cavities & Voids and On Soffit Above Brick Walls & Services | Insulation Residue & Debris | Assumed Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 2 | - | Old Northern Building Section, Throughout | On Soffit Surrounding Columns, Beneath New Insulation Board | Insulation Residue & Bituminous Coating (adhesive) | Assumed Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 3 | 304 | Cleaners Room | On Soffit Surrounding Column | Suspected Insulation Residue & Bituminous Coating (beneath new insulation board) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 3 | 305 | Electrical Room Adjacent Fire Stairs (3Q2) | On Soffit Surrounding Column | Insulation Residue & Bituminous Coating (adhesive) | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 25 May 2000. | Yes |
KENC | Kensington Campus | F21 | Library | 3 | 324 | Cleaners Room | On Soffit Surrounding Column | Suspected Insulation Residue & Bituminous Coating (beneath new insulation board) | Assumed Positive | Non-friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 4 | - | Old Northern Building Section, Throughout | Within Wall Cavities & Voids and On Soffit Above Brick Walls & Services | Insulation Residue & Debris | Assumed Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 4 | - | Old Northern Building Section, | On Soffit Surrounding Columns, Beneath New Insulation Board | Insulation Residue & Bituminous Coating (adhesive) | Assumed Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | 130A | Plant Room, West Side, SW Corner | Conduits | Moulded Fibre Cement Pipes | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | LG | LGQ06 | Air Conditioning Plant Room | Hot Water Pipework | Insulation (calico covered) | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 22 June 2020, 17 July 2020 & 21 December 2023. | Yes |
KENC | Kensington Campus | F21 | Library | LG | LGQ02 | Air Conditioning Plant Room | Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | LG | LGQ03 | Air Conditioning Plant Room | Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | LG | LGQ06 | Air Conditioning Plant Room | Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | LG | LGQ07 | Air Conditioning Plant Room | Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | LG | - | South West Plant Room | Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | 130A | Plant Room | Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | - | Main Floor Area, Shafts (Ducts) | Old Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 2 | - | Main Floor Area, Shafts (Ducts) | Old Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 3 | - | Main Floor Area, Shafts (Ducts) | Old Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 4 | - | Main Floor Area, Shafts (Ducts) | Old Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 5 | - | Ceiling Space, Shafts (Ducts) | Old Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | Yes |
KENC | Kensington Campus | F21 | Library | 6 | - | Ceiling Space, Shafts (Ducts) | Old Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 7 | - | Ceiling Space, Shafts (Ducts) | Old Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 8 | - | Ceiling Space, Shafts (Ducts) | Old Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 9 | - | Ceiling Space, Shafts (Ducts) | Old Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 10 | - | Ceiling Space, Shafts (Ducts) | Old Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 11 | - | Ceiling Space, Shafts (Ducts) | Old Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 12 | - | Ceiling Space, Shafts (Ducts) | Old Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 13 | - | Ceiling Space, Shafts (Ducts) | Old Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 14 | - | Ceiling Space, Shafts (Ducts) | Old Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 15 | 1501 | Plant Room | Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 15 | 15Q5 | Plant Room | Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | LG | LG19 | South Side, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | LG | LG21 | South Side, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 1Q6A | Ceiling Space Note: Previously Room 122A | Ductwork Flange Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | E2Q02 | Electrical Cupboard Adjacent Room 236A | - | Electrical Backing Boards | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | B | - | Throughout, Perimeter Brick Walls (behind intersecting brick walls) | On Vertical Metal Plate Strip | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | LG | - | Throughout, Perimeter Brick Walls (behind intersecting brick walls) | On Vertical Metal Plate Strip | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | - | Throughout, Perimeter Brick Walls (behind intersecting brick walls) | On Vertical Metal Plate Strip | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | - | Throughout, Perimeter Brick Walls (behind intersecting brick walls) | On Vertical Metal Plate Strip | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | - | Throughout, Perimeter Brick Walls (behind intersecting brick walls) | On Vertical Metal Plate Strip | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | - | Throughout, Perimeter Brick Walls (behind intersecting brick walls) | On Vertical Metal Plate Strip | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | LG | - | Exterior, East Side, Above Room LG16 | Roof | Bituminous Membrane | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | LG | - | Exterior, South Side, Outside Room LGQ2A, Covered Entry | Awning Roof | Bituminous Membrane | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G1 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G2 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G2A | North & South Sides, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G3 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G4 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G5 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G6 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G7 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G8 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G9 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G10 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G12 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G13 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G13A | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G14 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G16 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G17 | South Side, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G17A | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G18 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G18A | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G19A | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G19B | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G19C | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G19D | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G20 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G22 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G30 | North & South Sides, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G31 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G32 | South & West Sides, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G35 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 101 | South & East Sides, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 102 | North & East Sides, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 103 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 104 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 105 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 106 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 107 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 108 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 109 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 110 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 111 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 112 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 113 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 114 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 115 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 116 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 117 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 118 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 119 | South Side, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 120 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 121 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 124 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 125 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 125B | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 125C | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 127 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 128 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 129 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 130 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 131 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 132 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 133 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 134 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 135 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 136 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 138 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 139 | South & West Sides, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 1Q6 | East Side, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 201 | North & South Sides, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 203 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 204 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 205 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 207 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 208 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 209 | South Side, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 210 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 211 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 212 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 213 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 215 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 216 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 218 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 219 | North & South Sides, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 220 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 223 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 223A | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 224 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 226 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 227A | South Side, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 227B | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 228 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 233 | South Side, Below Window | Vertical Expansion Wall Joint1 | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 235 | South Side, Below Window | Vertical Expansion Wall Joint1 | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 237 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 239 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 241 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 243 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 244 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 245 | South & West Sides, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 246 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 248 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 250 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 252 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 2Q3A | East Side, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 301 | East Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 302 | North & East Sides, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 303 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 304 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 304A | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 305 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 306 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 307 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 308 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 309 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 310 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 311 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 312 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 314 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 315 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 316 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 317 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 318 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 319 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 320 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 321 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 322 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 323 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 324 | North Side, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 326 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | LG | MLG Q02 | Service Tunnel off Room LG5, Behind Room LG1 | Pipework | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F17 | Rex Vowels Theatre | LG | LGQ5 | Plant Room, Mezzanine Level | Air Conditioning Ductwork Section, Flange Joints (from air handling unit) | Mastic Sealant | Removed - Positive (Chrysotile) | - | - | - | Item Removed - Refer to RiskTech Compliance Asbestos Clearance Certificate dated 4 December 2023. | Yes |
KENC | Kensington Campus | F13 | Science Theatre | G | - | Exterior, Southern Façade | Window Frames (between frame & pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | G | - | Exterior, Western Façade | Window Frames (between frame & pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | 1 | - | Exterior, Eastern Façade | Window Frames (between frame & pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | 1 | - | Exterior, Southern Façade | Window Frames (between frame & pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | 1 | 100 | East | Window Frames (between frame & pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G07 | Electrical Cupboard, Ceiling Space | Attached to Nail Heads and Behind Plasterboard Wall | Fibre Cement Sheet Remamnts | Assumed Positive | Non-friable | Med | P3 | Restirct access to the ceiling space of Electrical Cupboard to authorised personnel. Only. Remove under controlled conditions by a Class A/B contractor as part of a planned control program. | No |
KENC | Kensington Campus | F12 | Dalton | 01 | - | Exterior of 1Q2 | Window Frames (between frame and pane) | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F12 | Dalton | 02 | - | Exterior of 2Q2 | Window Frames (between frame and pane) | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | - | Exterior, Façade | Windows (between frame and façade wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | - | Exterior, Façade | Windows (between frame and façade wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | - | Exterior, Façade | Windows (between frame and façade wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | - | Exterior, Façade | Windows (between frame and façade wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | - | Exterior, Façade | Windows (between frame and façade wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | - | Exterior, Façade | Windows (between frame and façade wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | - | Exterior, Façade | Windows (between frame and façade wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | - | Exterior, Façade | Windows (between frame and façade wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 356 | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 357A | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | - | Biolink, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 448 | Biolink, West, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 17/12/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 448A | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 449 | Biolink, West, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450 | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 01 | - | Exterior, North Side | Expansion Joints between Brickwork Sections | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 01-03 | - | Exterior, North, East, South & West Sides | Expansion Joints between Concrete & Brick Wall Sections | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 01 | 103 | Ductwork Service Risers | Ductwork Joins | Mastic Sealant (red colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 02 | - | Ductwork Service Risers | Ductwork Joins | Mastic Sealant (red colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 03 | - | Ductwork Service Risers | Ductwork Joins | Mastic Sealant (red colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 03 | - | Roof Space | Ductwork Joins | Mastic Sealant (red colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 01 | 103 | Ductwork Service Risers | Ductwork Flange Joints | Mastic Sealant (black colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 02 | - | Ductwork Service Risers | Ductwork Flange Joints | Mastic Sealant (black colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 03 | - | Ductwork Service Risers | Ductwork Flange Joints | Mastic Sealant (black colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 03 | - | Roof Space | Ductwork Flange Joints | Mastic Sealant (black colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D14 | UNSW Hall | G | - | Interior & Exterior Throughout | Window Frames (between frame and pane) | Mastic Sealant | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | - | Interior & Exterior Throughout | Window Frames (between frame and pane) | Mastic Sealant | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | - | Interior & Exterior Throughout | Window Frames (between frame and pane) | Mastic Sealant | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
KENC | Kensington Campus | D14 | UNSW Hall | 03 | - | Interior & Exterior Throughout | Window Frames (between frame and pane) | Mastic Sealant | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450D | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450E | Biolink, South, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 17/12/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450F | Biolink, South, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 17/12/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450G | Biolink, South, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 17/12/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 456 | Biolink, East, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 17/12/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | - | Biolink, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 550 | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 551 | Biolink, West, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552A | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552B | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552C | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 553 | Biolink, West, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554 | Biolink, West, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer Risktech clearane cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554A | Biolink, South, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554B | Biolink, South, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer RiskTech clearance cert 2nd February 2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554C | Biolink, South & West, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer RiskTech clearance cert 2nd February 2022 | Yes |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | G03 | Gymnasium (B5), Gym Area, South Side | Ductwork Flange Joints | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | G06A/G06B/G07/G07A | Gymnasium (B5), Toilets | Ductwork Flange Joints | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B14D | Fig Tree Theatre | G | - | Exterior, North East, Entrance, Roof Area | Eaves | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B14D | Fig Tree Theatre | G | - | Exterior, East, Main Theatre Entrance | Awning | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B14D | Fig Tree Theatre | G | - | Exterior, East, Main Theatre Entrance | Gable & Eaves | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | LG | LGQ05 | Air Conditioning Plant Room Above AHU No.2 | On Roof of Air Handling Unit | Suspected Insulation Debris | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 25 February 2019 & 2 March 2020. | No |
KENC | Kensington Campus | F21 | Library | 2 | - | Old Northern Building Section, Eastern Shafts (North, South & Centre) | General Surfaces & Top of Brick Walls | Suspected Insulation Residue & Debris | Assumed Positive | Friable | Med | P3 | Remove under controlled conditions by a Class A contractor as part of a planned control program. | No |
KENC | Kensington Campus | F21 | Library | 2 | - | Old Northern Building Section, Eastrern Shaft Opening (Centre) | On Soffit & Adjacent Surfaces | Insulation Residue & Debris | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 11 February 2019. | No |
KENC | Kensington Campus | F21 | Library | 2 | - | Old Northern Building Section, Western Shafts (North, South & Centre) | General Surfaces & Top of Brick Walls | Suspected Insulation Residue & Debris | Assumed Positive | Friable | Med | P3 | Remove under controlled conditions by a Class A contractor as part of a planned control program. | No |
KENC | Kensington Campus | F21 | Library | 3 | - | Old Northern Building Section, Eastern Shafts (North, South & Centre) | General Surfaces & Top of Brick Walls | Suspected Insulation Residue & Debris | Assumed Positive | Friable | Med | P3 | Remove under controlled conditions by a Class A contractor as part of a planned control program. | No |
KENC | Kensington Campus | F21 | Library | 3 | - | Old Northern Building Section, Eastern Shaft Opening (Centre) | On Soffit & Adjacent Surfaces | Insulation Residue & Debris | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 11 February 2019. | Yes |
KENC | Kensington Campus | F21 | Library | 3 | - | Old Northern Building Section, Western Shafts (North, South & Centre) | General Surfaces & Top of Brick Walls | Suspected Insulation Residue & Debris | Assumed Positive | Friable | Med | P3 | Remove under controlled conditions by a Class A contractor as part of a planned control program. | No |
KENC | Kensington Campus | F21 | Library | 4 | - | Old Northern Building Section, Western Shafts (North, South & Centre) | General Surfaces & Top of Brick Walls | Suspected Insulation Residue & Debris | Assumed Positive | Friable | Med | P3 | Remove under controlled conditions by a Class A contractor as part of a planned control program. | No |
KENC | Kensington Campus | F21 | Library | 4 | - | Old Northern Building Section, Western Shaft Openings (North & Centre) | On Soffit & Adjacent Surfaces | Insulation Residue & Debris | Removed - Positive (amosite) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 11 February 2019. | Yes |
KENC | Kensington Campus | F21 | Library | 4 | - | Old Northern Building Section, Eastern Shafts (North, South & Centre) | General Surfaces & Top of Brick Walls | Suspected Insulation Residue & Debris | Assumed Positive | Friable | Med | P3 | Remove under controlled conditions by a Class A contractor as part of a planned control program. | No |
Kenc | Kensington Campus | G15 | Robert Webster Theatres | 01-02 | - | Ceiling Spaces, Risers | Ductwork Joints (older ductwork) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | 03 | - | Interior | Window Frames (between frame & pane) | Mastic Sealant (black colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | 01 | - | Interior, Various Locations, Ceiling Space | Older Ductwork Joints | Mastic Sealant (red/green colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | 02 | 2Q3 | Fire Services Riser Cupboard & Hydraulic Duct Riser Cupboard | Ductwork Joints & Joins | Mastic Sealant (red/green colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | 02 | - | Interior, Ceiling Space, Various Locations | Older Ductwork Joints | Mastic Sealant (red/green colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | 03 | 3Q3 | Fire Services Riser Cupboard & Hydraulic Duct Riser Cupboard | Ductwork Joints & Joins | Mastic Sealant (red/green colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | 03 | - | Interior, Ceiling Space, Various Locations | Older Ductwork Joints & Joins | Mastic Sealant (red/green colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | G | - | Interior, North & West | Window Frames (between frame & pane) | Mastic Sealant (black colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | 01 | - | Interior, Throughout | Window Frames (between frame & pane) | Mastic Sealant (black colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | 02 | - | Interior, Throughout | Window Frames (between frame & pane) | Mastic Sealant (black colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | C6 | International House | 1 | 1Q2 | Plumbing Riser Adjacent Room 126 | Hot Water Pipework | Insulation | Positive - Removed | - | Item Removed: Refer to RiskTech Clearance Certificate dated 23rd December 2019 | Yes | ||
Kenc | Kensington Campus | C6 | International House | 2 | 2Q3 | Plumbing Riser Adjacent Room 226 | Hot Water Pipework | Insulation | Positive - Removed | - | Item Removed: Refer to RiskTech Clearance Certificate dated 23rd December 2019 | Yes | ||
Kenc | Kensington Campus | C6 | International House | 3 | 3Q3 | Plumbing Riser Adjacent Room 326 | Hot Water Pipework | Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Asbestos Clearance Certificate dated 23 December 2019. Removed by Pure Contracting. | Yes |
Kenc | Kensington Campus | C6 | International House | 1 | 199 | Male Amenities / Toilets - Plumbing Riser | On Floor, Walls & Other Surfaces | Insulation Residue & Debris | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Asbestos Clearance Certificate dated 23 December 2019. Removed by Pure Contracting. | Yes |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | G13A | Mens Toilet, Ceiling Space | Ductwork Joints & Joins | Mastic Sealant (red colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. Note: Mastic to ductwork may be present above set ceilings and in other inaccessible locations in the building. | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | 01 | - | Roof Space | Old Ductwork Joints & Joins (mostly behind foil covering) | Mastic Sealant (grey colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | G16 | South | Fire Damper Panel | Core Insulation | Assumed Positive | Friable | Low | P3 | Remediation works on fire panels should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | - | Exterior Throughout Level | Window Sill Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | - | Exterior Throughout Level | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | - | Exterior Throughout Level | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | - | Exterior Throughout Level | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | - | Exterior Throughout Level | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | - | Exterior Throughout Level | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | - | Exterior Throughout Level | Window Sill Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | - | Exterior Throughout Level | Window Sill Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | - | Exterior Throughout Level | Window Sill Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 02 | 2Q6 | Squash Courts (B7), Duct Riser | Ductwork Joins | Mastic Sealant (red colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 03 | 343 | Squash Courts (B7), Gas Valve Plant Room, South Side | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status and if contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 03 | 343 | Squash Courts (B7), Gas Valve Plant Room | Ductwork Flange Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | LG | - | Exterior, Throughout | Windows (between frame and pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | - | Exterior | Windows (between frame and brick facade) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Remediate (remove and/or seal) deteriorating mastic sealant under controlled conditions by a Class A/B contractor within a planned control program. | No |
KENC | Kensington Campus | K15 | Old Main | 01 | - | Exterior, Throughout | Windows (between frame and pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | 02 | - | Exterior | Windows (between frame and pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 555 | Biolink, South, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/22 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 556 | Biolink, South, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
FSFG | Fowlers Gap Field Station | FG5 | Fowlers Gap Cottage 2 | G | - | Exterior, All Sides | Walls | Profiled & Flat Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG5 | Fowlers Gap Cottage 3 | G | - | Exterior, South, East & West Sides | Awning & Carports Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG5 | Fowlers Gap Cottage 4 | G | - | Exterior, West Side | Carport - Upper Wall Panelling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG5 | Fowlers Gap Cottage 5 | G | - | Exterior, All Sides | Eaves | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q17 | West Roof Section (beneath concrete pavers, new membrane and/or plinths) | Roof | Bituminous Membrane | Assumed Positive | Non-friable | Low | P4 | Investigate the presence and extent of asbestos containing roof membrane beneath concrete pavers, new membrane layers and/or plinths prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G17 | Stage | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Consider sealing the egdes of the ceiling sheets under controlled conditions by a Class A/B contractor as part of a planned control program. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G18 | Stage Right | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Consider sealing the egdes of the ceiling sheets under controlled conditions by a Class A/B contractor as part of a planned control program. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MISC | Miscellaneous | BC34 | Woolley House | 02 | G03 & G05 | Living, Dining & Main Entry | Windows (between glass & internal timber framework) | Caulking Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
MISC | Miscellaneous | BC34 | Woolley House | 03 | G07 & GQ04 | Bed 2 & Bathroom | Windows (between glass & internal timber framework) | Caulking Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
MISC | Miscellaneous | BC34 | Woolley House | 03 | G08 | Study | Windows (between glass & internal timber framework) | Caulking Mastic | Assumed Positive | Non-friable | Low | P3 | Repair or remove deteriorating window caulking under controlled conditions by a Class A/B contractor or competent person within a planned control programs. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | - | Exterior, Façade, Throughout | Between Metal Window Framework & Glass | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 17 | - | Exterior, Façade, Throughout | Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 18 | - | Exterior, Façade, Throughout | Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | - | Exterior, Façade, Throughout | Between Metal Window Framework & Glass | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | - | Exterior, Façade, Throughout | Between Metal Window Framework & Glass | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | - | Exterior, Façade, Throughout | Between Metal Window Framework & Glass | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | - | Exterior, Façade, Throughout | Between Metal Window Framework & Glass | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | - | Exterior, Façade, Throughout | Between Metal Window Framework & Glass | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | - | Exterior, Façade, Throughout | Between Metal Window Framework & Glass | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | - | Exterior, Façade, Throughout | Between Metal Window Framework & Glass | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | - | Exterior, Façade, Throughout | Between Metal Window Framework & Glass | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | - | Exterior, Façade, Throughout | Between Metal Window Framework & Glass | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | - | Exterior, Façade, Throughout | Between Metal Window Framework & Glass | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | - | Exterior, Façade, Throughout | Between Metal Window Framework & Glass | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | - | Exterior, Façade, Throughout | Between Metal Window Framework & Glass | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | - | Exterior, Façade, Throughout | Between Metal Window Framework & Glass | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | - | Exterior, Façade, Throughout | Between Metal Window Framework & Glass | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | - | Exterior, Façade, Throughout | Between Metal Window Framework & Glass | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 2 | - | Exterior, Façade, Tower | Between Metal Window Framework & Glass | Mastic Sealant (dark grey/black colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 3 | - | Exterior, Façade | Between Metal Window Framework & Glass | Mastic Sealant (dark grey/black colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 4 | - | Exterior, Façade | Between Metal Window Framework & Glass | Mastic Sealant (dark grey/black colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 5 | - | Exterior, Façade | Between Metal Window Framework & Glass | Mastic Sealant (dark grey/black colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 6 | - | Exterior, Façade | Between Metal Window Framework & Glass | Mastic Sealant (dark grey/black colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 7 | - | Exterior, Façade | Between Metal Window Framework & Glass | Mastic Sealant (dark grey/black colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 8 | - | Exterior, Façade | Between Metal Window Framework & Glass | Mastic Sealant (dark grey/black colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 9 | - | Exterior, Façade | Between Metal Window Framework & Glass | Mastic Sealant (dark grey/black colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 10 | - | Exterior, Façade | Between Metal Window Framework & Glass | Mastic Sealant (dark grey/black colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 12 | - | Exterior, Façade | Between Metal Window Framework & Glass | Mastic Sealant (dark grey/black colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 13 | - | Exterior, Façade | Between Metal Window Framework & Glass | Mastic Sealant (dark grey/black colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 14 | - | Exterior, Façade | Between Metal Window Framework & Glass | Mastic Sealant (dark grey/black colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 2 | - | Exterior, Façade, Old Low Rise Northern Brick Section, North Side | Between Metal Window Framework & Glass | Caulking Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 3 | - | Exterior, Façade, Old Low Rise Northern Brick Section | Between Metal Window Framework & Glass | Caulking Mastic (brown colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 4 | - | Exterior, Façade, Old Low Rise Northern Brick Section | Between Metal Window Framework & Glass | Caulking Mastic (brown colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | - | Exterior, Façade, Tower, Old Northern building Section, Throughout | Window Framework, Concrete Façade Panel & Brick Expansion Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 2 | - | Exterior, Façade, Tower, Old Northern building Section, Throughout | Window Framework, Concrete Façade Panel & Brick Expansion Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 3 | - | Exterior, Façade, Tower, Old Northern Building Section, Throughout | Window Framework, Concrete Façade Panel & Brick Expansion Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 4 | - | Exterior, Façade, Tower, Old Northern building Section, Throughout | Window Framework, Concrete Façade Panel & Brick Expansion Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 5 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 6 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 8 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 8 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 9 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 10 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 11 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 12 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 13 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 14 | - | Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 557 | Biolink, South & East, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 558 | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 559 | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 560 | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 561 | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 563 | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 564 | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 567 | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 568 | Biolink, East, | Spandrel Brackets | Insulation | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 570 | Biolink, East, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | - | Biolink, | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 565 | - | Ceiling Tiles | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 567 | - | Ceiling Tiles | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q8 | - | Ceiling Tiles | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | G01 | Cutting Room | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | G01A | Store | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | G03 | Store | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | G04 | Laboratory Store | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | G05 | Laboratory | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | G05A | Laboratory | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | G06 | Mid-North Office, North Side | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | G07 | Office | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | G08 | Balance room | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | G09 | Office | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | G010 | Toilet | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | G11 | Library | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | G12 | Kitchen | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | GQ1 | Corridor | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | GQ2 | Corridor | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | - | Exterior, Eastern Verandah, North, South & East Sides | Walls & Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | - | Exterior, Western Verandah, North, South & West Sides and Southern End of East Side | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | - | Exterior, All Sides | Eaves (Note: Localised damaged area on south side) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Remedial works should be undertaken by a Class A/B Contractor or competent person within a planned control program. | No |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | - | Exterior, South Side | Awning Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | - | Exterior, All Sides | Eaves | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | - | Exterior, South Side | Awning Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Item removed as per Risktech clearance certificate dated 3/09/2024 | Yes |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | - | Exterior, All Sides | Eaves | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Item removed as per Risktech clearance certificate dated 3/09/2024 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q11 | - | Ceiling Tiles | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 2 February 2022. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | M | MQ1 | (Previously Room MQ9, M15 & M16) Below Ceramic Floor Tiles | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below flooring prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | M | MQ2 | Below Ceramic Floor Tiles | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | M | M10 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new flooring) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | M | M11 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | M | M17 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 1Q2 | (Previously Rooms 114, 115, 116 & 117) Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 104 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 105 | Toilets, Entrance Hallway | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 107 | - | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 108 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 109 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 110 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 111 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 112 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 113A | (Previously Rooms 1Q2, 118, 118A & B) Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 113B | (Previously Room 118 & 118C) Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 206 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 208 | (Previously Rooms 207, 209 & 210) Under New Flooring Covering | Floor Covering | Adhesive (Clearance states adhesive present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 212 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 213 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 214 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 215 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 216 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 217 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 218 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 219 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 105 | Toilets, Entrance Hallway | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 107 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 205 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 211 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 310 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 205 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 211 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 303 | - | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 307 | Under Carpet Tiles | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 309 | Under Carpet Tiles | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 312 | Under Carpet | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 313 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 314 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 315 | - | Floor Covering | Adhesive (majority of adhesive removed except on the perimeter of the room) | Assumed Positive | Non-friable | Low | P4 | Majority of item removed by Pure Contracting on 10/3/2012. NAA Clearance Certificate (C107946:J105057) Maintain remaining material in current condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 316 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 321 | - | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 322 | - | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 323 | Entry Foyer & Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 324 | Entry Foyer & Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 410 | (Previously Rooms 410, 411) Throughout | Floor Covering | Adhesive (majority of adhesive removed except on the perimeter of the rooms) | Assumed Positive | Non-friable | Low | P4 | Majority of item removed by Pure Contracting on 9/6/2012. NAA Clearance Certificate (C107946:J111637) Maintain remaining material in current condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 412 | (Previously Rooms 414, 415/416) Wall Perimeter | Floor Covering | Adhesive (majority of adhesive removed except on the perimeter of the rooms) | Assumed Positive | Non-friable | Low | P4 | Majority of item removed by Pure Contracting on 9/6/2012. NAA Clearance Certificate (C107946:J111637) Maintain remaining material in current condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 303 | - | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 307 | Under Carpet Tiles | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 309 | Under Carpet Tiles | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 312 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 21 March 2023. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 313 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 314 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 316 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 321 | - | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 322 | - | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 4Q2 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 401 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 409 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 411 | (Previously Rooms 412, 413) Under Carpet | Floor Covering | Adhesive (majority of adhesive removed except on the perimeter of the rooms) | Assumed Positive | Non-friable | Low | P4 | Majority of item removed by Pure Contracting on 9/6/2012. NAA Clearance Certificate (C107946:J111637) Maintain remaining material in current condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 413 | (Previously Rooms 417, 418, 419) Wall Perimeter | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 514 | North Section of Room (previously Room 514A) | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 503B | - | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 505 | - | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 508 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 510 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 510A | - | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 511 | - | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 503B | - | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 505 | - | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 508 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 510 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 510A | - | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 511 | - | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 601 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 601A | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 602 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 603 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 603A | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 603B | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 606 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 607 | - | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 608 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 609 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 610 | - | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 611 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 612 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 614B | - | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 615 | - | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 606 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 607 | - | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 608 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 609 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 610 | - | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 611 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 612 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 614B | - | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 615 | - | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 701 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new flooring covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 701A | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 701B | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 701C | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 706 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 707 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 708 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 709 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 710 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 711 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 711A | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 712 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 713 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 714 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 714C | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 715 | - | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 716 | - | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 706 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 707 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 708 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 709 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 710 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 711 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 711A | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 712 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 713 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 714 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 714C | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 715 | - | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 716 | - | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 801A | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 801D | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 805 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 806 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 807 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 808 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 809 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 810 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 811 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 812 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 813 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 814 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 815 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 816 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 816A | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 819A | - | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 820 | (Previously Rooms 817, 818, 819 B-L) Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 822 | (Previously Rooms 817, 818, 819 B-L) Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 823 | (Previously Rooms 817, 818, 819 B-L) Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 824 | (Previously Rooms 817, 818, 819 B-L) Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 805 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 806 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 807 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 808 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 809 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 810 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 811 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 812 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 813 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 814 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 815 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 819A | - | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 901A | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 903 | Underneath existing fixtures (partition walls, equipment) | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 906 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 907 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 908 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 909 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 910 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 911 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 912 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 914 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 915 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 916 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 918 | Under Carpet | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 919 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 920 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 921 | Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 903 | Underneath existing fixtures (partition walls, equipment) | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 906 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 907 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 908 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 909 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 910 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 911 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 912 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 914 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 915 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 916 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 918 | Under Carpet | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | G | G05 | South adjoining Room | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | G | G11 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | G | G12 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | G | G12A | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | G | G13 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | G | G14 | Under Carpet | Floor Covering | Vinyl Tiles | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | G | G14A | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | G | G14B | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 563 | - | Ceiling Tiles | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 564 | - | Ceiling | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 569B | North | Wall | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 563 | North, South & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450A | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450B | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450C | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450D | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 17/12/2021 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | - | Exterior, Surrounding | Windows | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | - | Exterior, Surrounding | Windows | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | - | Exterior, Surrounding | Windows | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | - | Exterior, Surrounding | Windows | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | - | Exterior, Surrounding | Windows | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | - | Exterior, Surrounding | Windows | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | - | Exterior, Surrounding | Windows | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450E | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 17/12/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450F | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450G | Biolink, | Walls & Partition Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/12/21 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 451 | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 17/12/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 452A | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 17/12/2021 | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 452B | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 17/12/2021 | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 453 | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 17/12/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 454 | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 17/12/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 456 | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 17/12/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 550 | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearnce cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 551 | North, South & East | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 551A | North, South, East & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552 | North, South, East & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552A | North, South & East | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552B | North, South & East | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552C | North, South & East | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 553 | North, South & East | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
KENC | Kensington Campus | K17 | Building K17 | 1 | 1Q03 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 103 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 104 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 104A | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 104B | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 105 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 105A | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 105B | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 106 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 107 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 111A | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 111B | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 111C | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 111E | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 111F | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 111G | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 111H | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 112 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 113 | Under Carpet | Floor Covering | Vinyl Floor Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | LG | LG43 | - | Flue | Moulded Fibre Cement | Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G33 | - | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 155 | Electrical Cupboard | Floor Covering | Vinyl Tiles (grey colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 162 | Under Carpet Tiles | Floor Covering | Vinyl Tiles (grey colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q9 | Under Carpet Tiles | Floor Covering | Vinyl Tiles (grey colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q11 | Under Carpet Tiles | Floor Covering | Vinyl Tiles (grey colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment | No |
KENC | Kensington Campus | K15 | Old Main | 01 | - | Exterior, Northern Wings x 3 | Eaves | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | 02 | - | Exterior, North Side, Outside Room 210A, Right Side Window | Windows (between frame and pane) | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 101 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | - | - | - | Item removed 12/11/2011 by Aston Group - Gatex Asbestos Clearance Certificate (Ref: 6497.01ASCC) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | G | GQ7 | Cleaners Store Room | Floor Covering | Vinyl Tiles (Blue Colour) | Assumed Positive | Non-friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | G | G4 | Throughout | Floor Covering (benaeth carpet) | Vinyl Tiles (Blue Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 103 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Grey Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 105 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Grey Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 115 | Throughout | Floor Covering | Vinyl Tiles (Grey Colour) | Removed Positive | - | - | - | Item removed. Refer RiskTech clearance cert dated 9th Sept 23 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 107 | Throughout | Floor Covering | Vinyl Tiles (Light Green Colour) | Removed Positive | - | - | - | Item removed. Refer RiskTech clearance cert dated 9th Sept 23 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 102 | Throughout | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 104 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 106 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 108 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 109 | Throughout | Floor Covering | Vinyl Tiles (Aqua Colour) | Positive - removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 20231125 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 110 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 201 | Southeast, Under Computer Server | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 203 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 205 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 207 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 208 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 213 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 27 July 2019. Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 214 | Throughout | Floor Covering | Vinyl Tiles (Aqua Colour) | Positive - removed | - | - | - | Item removed. Refer Risktech clearance cert dated Sept 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 303 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 314 | Throughout | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - removed | - | - | - | Item removed. Refer RiskTech clearance cert dated Sept 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 305 | Throughout | Floor Covering | Vinyl Tiles (Light Green Colour) | Assumed Positive - removed | - | - | - | Item removed. Refer RiskTech clearance cert dated Sept 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 405 | Throughout | Floor Covering | Vinyl Tiles (Light Green Colour) | Positive - removed | - | - | - | Item removed. Refer Risktech clearance cert dated 19 Aug 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 505 | Throughout | Floor Covering | Vinyl Tiles (Light Green Colour) | Positive - removed | - | - | - | - | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 606 | Throughout | Floor Covering | Vinyl Tiles (Light Green Colour) | Positive - removed | - | - | - | Item removed. Refer RiskTech clearance cert dated Oct 2023 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 414 | Throughout | Floor Covering | Vinyl Tiles (Blue & Black Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 304 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 307 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Item removed- refer to Risktech Clearance Certificate dated 08/10/2024 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 308 | Throughout (beneath vinyl sheeting) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 311 | Throughout (beneath vinyl sheeting) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 312 | Throughout (beneath vinyl sheeting) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 502 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 503 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 504 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 506 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 510 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 513 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 514 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 27 July 2019. Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 515 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Grey Colour) | Positive - removed | - | - | - | - | Yes |
Kenc | Kensington Campus | G15 | Robert Webster Theatres | 01 | 191A | West, Interior & Exterior | Window Frames (Between Frame and Pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | G15 | Robert Webster Theatres | 02 | - | Exterior, West Side | Window Frames (Between Frame & Outer Metal Boxing) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F22 | Bank | 01 | 110 | Northern Campus Precinct - Store | Floor Covering (suspected vinyl tiles under sheet vinyl & carpet tiles) | Vinyl Tiles (cream & green colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F22 | Bank | 01 | 107 | Northern Campus Precinct - Store | Floor Covering | Vinyl Tiles (cream & green colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F22 | Bank | 01 | 108 | Northern Campus Precinct - Store | Floor Covering (suspected vinyl tiles under sheet vinyl & carpet tiles) | Vinyl Tiles (cream & green colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F22 | Bank | 02 | 201 | - | Floor Covering (under carpet tiles) | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F22 | Bank | 02 | 202 | - | Floor Covering (suspected vinyl tiles under carpet) | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F22 | Bank | 02 | 203 | - | Floor Covering (suspected vinyl tiles under carpet) | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F22 | Bank | 02 | 204 | - | Floor Covering (under carpet tiles) | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F22 | Bank | 02 | 205 | - | Floor Covering (under carpet tiles) | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F22 | Bank | 02 | 206 | - | Floor Covering (under carpet tiles) | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F22 | Bank | 02 | 207 | - | Floor Covering (suspected under new floor covering) | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F22 | Bank | 02 | 209 | - | Floor Covering (under carpet) | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F22 | Bank | 2 | 2Q2 | - | Floor Covering (under carpet tiles) | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | 1 | 104 | North-East, South-East and North-West | Service Riser Panelling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | 1 | 1Q7 | South of 106 | Service Riser Panelling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G15 | North-East, South-East & South-West | Service Riser Panelling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | 1 | 104 | Area Above Room 104 | Ceiling Infill | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | 1 | 104 | South and North-East | Wall Lining | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | 1 | 104 | Throughout | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | 02 | - | Exterior Throughout | Window Frames (between frame & pane) | Mastic Sealant (grey colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554 | North, South & East | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554A | North, South, East & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554B | North, South, East & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554C | North, South & East | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 555 | North, South, East & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 556 | North, South, East & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 557 | North, South & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 558 | North, South & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 559 | North, South & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer RiskTech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 560 | North, South & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 561 | North, South & West | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech clearance cert dated 02/02/2022 | Yes |
KENC | Kensington Campus | C20 | Morven Brown | LG | LGQ9 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | - | Exterior Throughout Level | Window Sill Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG24B | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG48 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | LGQ3A | Throughout | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G11 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G13 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G14 | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G15 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G16 | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G17 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G21 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G22 | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G24 | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G25 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G27 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G28 | North and West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G29 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G31 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G32 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G37 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G40 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G42 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G43 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G46 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G48 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G45 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G52 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G60 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | G62 | Throughout | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ1 | Throughout | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ10 | Throughout | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 304A | - | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 307 | - | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 310 | - | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | - | Interior/Exterior Throughout | Window Beading (Between Frame and Pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | - | Interior/Exterior Throughout | Window Beading (Between Frame and Pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | - | Interior/Exterior Throughout | Window Beading (between Frame and Pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | - | Interior/Exterior Throughout | Window Beading (between Frame and Pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | - | Interior/Exterior Throughout | Window Beading (between Frame and Pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 103 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 104 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 105 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 106 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 115 | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 117 | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 118 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 123 | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 124 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 126 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 128 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 129 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 133 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 134 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 135 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 137 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 139 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 142 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 143 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 144 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 145 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 147 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 148 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 151 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 152 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 154 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 158 | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 162 | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 163 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 165 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 168 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 170 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q1 | Throughout | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q4 | Throughout | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q10 | Throughout | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q4 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q10 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 204 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 205 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 207 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 208 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 209 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 210 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 211 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 213 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 214/215 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 218 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 223 | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 225 | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 226 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 228 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 231 | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 236 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 238 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 243 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 245 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 250 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 252 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 264 | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 265 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 267 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 268 | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 270 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 273 | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 275 | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 277 | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 280 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q1 | Throughout | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q10 | Throughout | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q4 | Throughout | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 316 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 323 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 324 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 329 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 330 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 335 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 336 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 340 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 341 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 342 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 344 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 353 | South | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 354 | North | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 360 | West | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 363 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 364 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 372 | East | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q1 | Throughout | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q10 | Throughout | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q4 | Throughout | Wall Expansion Joint | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 139 | Biolink, | Pipe Penetrations | Rope Packing Insulation (suspected beneath sealant covering) | Removed | - | - | - | Item removed. Refer RiskTech Clearance cert dated 28/09/2021 | Yes |
KENE | Kensington Environs | AS14 | 14 Arthur Street | G | - | Exterior, East, Entrance | Awning Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS10 | 10 Arthur Street | G | G02 | Eastern Side Door Surround | Infill Panels | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS10 | 10 Arthur Street | G | G07 | East | Wall | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 254 | Biolink, | Pipe Penetrations | Rope Packing Insulation | Removed | - | - | - | Item removed. Refer RiskTech Clearance cert dated 13/10/2021 | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 177 | North & East | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 179 | Sprinkler Pump Room, North & South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q11 | - | On Top of Blockwork Walls & Vertical Expansion Wall Joints x 5 | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q17 | South | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 201A | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 205 | South | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 209 | North | Vertical Expansion Wall Joint | Sealant Mastic | Removed -Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 209A | North | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 210 | North & SE Corner | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 229 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 230 | West (behind plasterboard wall) | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q1 | West (behind plasterboard wall) | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q5 | North & East | Vertical Expansion Wall Joints & Floor & Siffit Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q6 | North & South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q7 | West | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 301 | East, South & North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 302 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 303 | South, East & west | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 312 | North | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive - removed | - | - | - | Item removed. Refer Airsafe clearance cert dated 13-17/10/23 | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q5 | West & South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q6 | North & South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q9 | West | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q11 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 417 | - | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 418 | - | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 419 | North | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 420 | North | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 444 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 450 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 450 | East | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 453 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 454 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 455 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 456 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 457 | West | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 458 | West | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 459 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 460 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 462 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 463 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 464 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 465 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 466 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 467 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 470 | East | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 471 | East | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 472 | East | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 475 | East | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 475A | East | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q1 | - | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q7 | - | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q10 | - | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q12 | - | On Top of Blockwork Walls | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q18 | - | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q19 | - | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 618 | Service Duct off Room 618 | Fire Door (tagged 'Metalbilt') | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 259 | Biolink, | Walls | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech Clearance cert dated 13/10/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 255 | Biolink, | Debris | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktech Clearance cert dated 13/10/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 256 | Biolink, | Debris | Fibre Cement Sheeting | Removed | - | - | - | Item removed. Refer Risktach Clearance cert dated 13/10/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 349 | Biolink, | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/11/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 349B | Biolink, | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 349C | Biolink, | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 349D | Biolink, | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350 | Biolink, | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350A | Biolink, | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350B | Biolink, | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Restrict access to the ceiling space to authorised personnel. Remove under controlled conditions by a Class A/B contractor as part of a planned control program or prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350C | Biolink, | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Restrict access to the ceiling space to authorised personnel. Remove under controlled conditions by a Class A/B contractor as part of a planned control program or prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350D | Biolink, | Debris (suspected) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Restrict access to the ceiling space to authorised personnel. Remove under controlled conditions by a Class A/B contractor as part of a planned control program or prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 349 | Biolink | Ceiling Tiles | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech clearance cert dated 17/11/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 349B | Biolink | Ceiling | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 349C | Biolink | Ceiling | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 349D | Biolink | Ceiling | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350 | Biolink | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 November 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350A | Biolink | Ceiling | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021 | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350B | Biolink | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 November 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350C | Biolink | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 November 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350D | Biolink | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 November 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 2Q7 | Biolink | On Concrete Floor Slab (beneath tiles) | Adhesive | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 341 | Biolink | On Concrete Floor Slab (beneath tiles) | Adhesive | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 343 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance cert dated 17/11/2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 343A | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 343C | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 343D | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 344 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 345 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 346 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 347 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 341 | Biolink | Walls | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 342 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - removed | - | - | - | Item removed. Refer Risktech Clearance Cert dated 17/11/2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 458 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. (Note: No access at time of inspection - construction area). | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 573 | North, South, West & East | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. (Note: No access at time of inspection - construction area). | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 134 | Biolink, On Top of Metal Ceiling Hood | Debris | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 28 September 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q6 | Biolink | On Concrete Floor Slab (suspected beneath sheet vinyl) | Bituminous Adhesive | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LGQ11 | Biolink, Communications Riser Cupboard | Floor Slab Penetrations | Packing Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to NAA Clearance Report C107859:J125585 dated March 2014. Material has been removed from accessible locations. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | ELGQ02 | Biolink, Former Electrical Riser Cupboard off Room LGQ11 | Floor Slab Penetrations | Packing Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to NAA Clearance Report C107859:J125585 dated March 2014. Material has been removed from accessible locations. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | GQ13 | Biolink, | Floor Slab Penetrations | Packing Insulation | Assumed Positive - Removed | - | - | - | Item Removed: Refer to NAA Clearance Report C107859:J125585 dated March 2014. Material has been removed from accessible locations. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | GQ13 | Bilolink, | Floor Slab Penetrations | Packing insulation | Assumed Positive - Removed | - | - | - | Item Removed: Refer to NAA Clearance Report C107859:J125585 dated March 2014. Material has been removed from accessible locations. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q12 | Biolink, Communication Riser Cupboard | Floor Slab Penetrations | Packing Insulation | Removed -Positive | - | - | - | Item Removed: Refer to NAA Clearance Report C107859:J125585 dated March 2014. Material has been removed from accessible locations. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 2Q7 | Biolink, Electrical Riser Cupboard | Floor Slab Penetrations | Packing Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 13 October 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q6 | Biolink, Communication Riser Cupboard | Floor Slab Penetrations | Packing Insulation | Removed -Positive | - | - | - | Item Removed: Refer to NAA Clearance Report C107859:J125585 dated March 2014. Material has been removed from accessible locations. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q6 | Biolink, Communication Riser Cupboard | Floor Slab Penetrations | Packing Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to NAA Clearance Report C107859:J125585 dated March 2014. Material has been removed from accessible locations. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q6 | Biolink, Electrical Riser Cupboard | Floor Slab Penetrations | Packing Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to NAA Clearance Report C107859:J125585 dated March 2014. Material has been removed from accessible locations. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q7 | Communication Riser Cupboard | Floor Slab Penetrations | Packing Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to NAA Clearance Report C107859:J125585 dated March 2014. Material has been removed from accessible locations. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q7 | Electrical Riser Cupboard | Floor Slab Penetrations | Packing Insulation | Assumed Positive - Removed | - | - | - | Item Removed: Refer to NAA Clearance Report C107859:J125585 dated March 2014. Material has been removed from accessible locations. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | R01 | Plant Room, East Side, SE Corner | Floor Slab Penetration | Packing Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to NAA Clearance Report C107859:J125585 dated March 2014. Material has been removed from accessible locations. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 541 | Biosciences North | On Ground Surface (beneath new floor covering) | Bituminous Adhesive | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G29 | Biolink | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New fire door tag 'Bismac 2005'). | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 143 | Biolink | Ceiling Tiles | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 143A | Biolink | Ceiling Tiles | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 143A | Biolink | Walls | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 144 | Biolink | Walls | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 241 | Biolink, | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 252 | Biolink, Former Room 251 & 252 | Fire Door | Insulation Core | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 260 | Biolink | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 341 | Biolink, North Entry | Fire Door (tagged 'Inglis, 1990') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 342 | Biolink | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 346 | Biolink | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 349 | Biolink, | Fire Door | Insulation Core | Assumed Positive - removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q6 | Biolink | Ceiling Tiles | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q6 | Biolink, East (between Room 343 & 344) | Walls | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: NAA Clearance Report (Ref: SS00263:77747) dated October 2011. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q6 | Biolink | Ceiling Tiles | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 301D | Biosciences North | Walls | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G20 | Biolink, North, Access to Room G14 | Fire Door | Insulation Core | Removed - Assumed Positive | - | - | - | Item Removed: Refer to Greencap NAA Asbestos Clearance Certificate (Ref: C107266:J134916.003) dated 28 September 2015. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LGQ11 | Biolink | Walls | Fibre Cement Sheeting | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG03 | Biolink, Former Room LG21, Ceiling Space | Debris | Fibre Cement Sheeting | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 202 | Biosciences North | Fume Cupboard, Internal Lining | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 207 | Biosciences North | Fume Cupboard, Internal Lining | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG024 | Biolink, | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New fire door tagged 'Ikon Door - Manufactured 201-'). | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LGQ11 | Biolink | Ceiling Tiles | Fibre Cement Sheeting | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG03 | Biolink, Former Room LG21 | Walls & Ceiling | Fibre Cement Sheeting | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG07 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG08 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG10 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG10A | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG11 | Biolink, | Wall | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G29 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G29A | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 241 | Biolink, | Ceiling Tiles | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 134 | Biolink | Fire Door | Insulation Core | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. Note: New fire door tagged 'Bismac 20--'. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 137 | Biolink | Fire Door | Insulation Core | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 138 | Biolink | Fire Door | Insulation Core | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. Note: New fire door tagged 'Bismac 20--'. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 202 | Biosciences North, | Walls | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 205 | Biosciences North | Walls | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 139 | Biolink | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: Refer to Greencap NAA Asbestos Clearance Certificate (Ref: C107266:J134916.003) dated 28 September 2015. (Note: New fire door tagged 'TDF 2015'). | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 240 | Biolink | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: Refer to Greencap NAA Asbestos Clearance Certificate (Ref: C107266:J134916.003) dated 28 September 2015. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 254 | Biolink | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: Refer to Greencap NAA Asbestos Clearance Certificate (Ref: C107266:J134916.003) dated 28 September 2015. (Note: New fire door tagged 'TDF 2015'). | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 255 | Biolink | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: Refer to Greencap NAA Asbestos Clearance Certificate (Ref: C107266:J134916.003) dated 28 September 2015. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q7 | Biolink | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New fire door tagged 'Hume Door & Timber 2015'). | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q9 | Biolink | Fire Door | Insulation Core | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 448 | Biolink | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q02 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q03 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q04 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q05 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q07 | Under Carpet | Floor Covering | Vinyl Floor Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 201 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 201A | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 201B | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 201C | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 201D | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 201E | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 201F | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 201G | Under Carpet | Floor Covering | Vinyl Floor Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 202 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 203 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 204 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 205 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 206 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 207 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 208 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 209 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 210 | Under Carpet | Floor Covering | Vinyl Floor Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 211 | Throughout | Floor Covering | Vinyl Tiles (brown colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 212 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 213 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 216 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 217 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 217A | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 217F | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 217G | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 217H | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 218 | Under Carpet | Floor Covering | Vinyl Floor Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 3Q02 | Under Carpet | Floor Covering | Vinyl Floor Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 304 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 306 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 307 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 308 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 309 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 310 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 311 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 312 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | LR | R1 | Eastern Plant Room | Compressed Air Pipework | Gasket | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | WR41 | 41 Wansey Road | LG | - | Exterior, Backyard, North, to Neighbouring Property | Wall | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS1 | Wellington Field Station Cottage | G | 1 | Main Residence, East Room - Sunroom, West Side | Wall | Profiled Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS2 | Wellington Field Station Shearing Shed | G | G01 | West Side, Near NW Corner, Kitchen - South & West Sides | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS2A | Wellington Field Station Accommodation | G | G01 | Throughout | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS2A | Wellington Field Station Accommodation | G | G02 | Throughout | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS2A | Wellington Field Station Accommodation | G | G03 | Throughout | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS2A | Wellington Field Station Accommodation | G | G04 | Throughout | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS2A | Wellington Field Station Accommodation | G | G05 | Throughout | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS2A | Wellington Field Station Accommodation | G | - | Exterior, East | Awning Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Repair/seal the localised damage areas to the wall sheeting under controlled conditions within a planned control program. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS4A | Wellington Field Station Cool Room | G | G02 | Throughout | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSW | Wellington Field Station | WFS4A | Wellington Field Station Cool Room | G | G02 | Throughout | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q7 | Biolink | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New fire door tagged 'Hume Door & Timber 2015'). | Yes |
RANC | Randwick Campus | R1 | Randwick R1 | G | G27 | Under New Vinyl Floor Sheet | Floor Covering (suspected present beneath sheet vinyl) | Vinyl Tiles (tan colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q01 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 02 | 2Q1 | Stairwell, South | Windows (between frame and glazing) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 03 | 3Q1 | Stairwell, South | Windows (between frame and glazing) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 04 | 4Q1 | Stairwell, South | Windows (between frame and glazing) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 05 | 5Q1 | Stairwell, South | Windows (between frame and glazing) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | - | Throughout | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | - | Throughout | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | - | Throughout | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | - | Throughout | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | - | Throughout | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | - | Throughout | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | - | Throughout | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G16 | Stage Left, NW Corner | Service Riser Panelling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G08 & G08A | North & East (North Section) | Wall | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F12 | Dalton | G | GQ2 | North-East & South-East | Window Frames (between frame and pane) | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F12 | Dalton | 01 | 1Q2 | North-East & South-East | Window Frames (between frame and pane) | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | G | - | Exterior, North & West Elevations | Window Frames (between frame & pane) | Mastic Sealant (grey colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | 03 | - | Exterior Throughout | Window Frames (between frame & pane) | Mastic Sealant (grey colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q10 | - | Fire Door | Insulation Core | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. Note: New fire door tagged 'Hume Door & Timber 2015'. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 448B | Biolink | Fire Door | Insulation Core | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 449 | Biolink | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 450 | Biolink | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New fire door tagged 'Bismac 200-'). | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 457 | Biolink | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | D23 | Mathews Theatres | 01 | 150 | Plant Room, Western Section | Ductwork Joins | Mastic Sealant (grey colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 01 | 150 | Plant Room | Air Handling Unit Joints | Mastic Sealant | Removed -Assumed Positive | - | - | - | Item Removed. No removal/clearance documentation available. | Yes |
Kenc | Kensington Campus | D14 | UNSW Hall | G | A89 | - | Flue | Bituminous Cement | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
KENC | Kensington Campus | D14 | UNSW Hall | G | MAGQ01 | Riser adjacent Room A95A | Flue | Bituminous Cement | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
KENC | Kensington Campus | D14 | UNSW Hall | G | MCGQ02 | Riser adjacent Room CG21 | Flue | Bituminous Cement | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | A189 | - | Flue | Bituminous Cement | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | MA1Q01 | Riser Adjacent Room A198A | Flue | Bituminous Cement | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | C198 | Horizontal, Hot Water Units | Flue | Bituminous Cement | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | MC1Q05 | Riser Adjacent Room C198 | Flue | Bituminous Cement | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | MC1Q03 | Riser Adjacent Room C194A | Flue | Bituminous Cement | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | A289 | - | Flue | Bituminous Cement | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | MA2Q01 | Riser Adjacent A298A | Flue | Bituminous Cement | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | MC2Q03 | Riser Adjacent C295 | Flue | Bituminous Cement | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | C298 | Riser | Flue | Bituminous Cement | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
KENC | Kensington Campus | D14 | UNSW Hall | 03 | MC3Q01 | Riser Adjacent Room C394A | Flue | Bituminous Cement | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
KENC | Kensington Campus | D14 | UNSW Hall | 03 | MC3Q04 | Riser Adjacent Room C398 | Flue | Bituminous Cement | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | - | Exterior, West | Awning Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G02 | Quarters | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G03 | Quarters | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G04 | Quarters | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G05 | Quarters | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G06 | Dining Room | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G08 | Quarters | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G10 | Lounge Room | Floor Covering (beneath carpet) | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G11 | Quarters | Floor Covering (beneath carpet) | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G12 | Quarters | Floor Covering (beneath carpet) | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G14 | Common Room | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G15 | Quarters | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G16 | Quarters | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G17 | Quarters | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G18 | Quarters | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | GQ6 | Corridor | Floor Covering (beneath carpet) | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | GQ3 | Womens Toilet & Amenities | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | GQ4 | Womens Toilet | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | GQ5 | Corridor | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | GQ7 | Mens Toilet & Amenities | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | GQ3 | Womens Toilet & Amenities | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | GQ4 | Womens Toilet | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | GQ5 | Corridor | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G01 | Store Room | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G01 | Store Room | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G07A | Pantry | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G19 | Store Room | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G19 | Store Room | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | GQ1 | Corridor | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | GQ1 | Corridor | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G09 | Kitchen | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | G13 | Bathroom | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | - | Mid Western Room, Office, Between Main Bedroom Ensuite & Toilet | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | - | SE Corner Room, Sunroom | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | - | Mid Western Room, Office, Between Main Bedroom Ensuite & Toilet | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | - | SE Corner Room, Sunroom | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | G01 | Far NW Corner Room, | Walls (behind ceramic tiles) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG15 | Fowlers Gap Cottage 1 | G | G04/ G04A/G04B | Toilet and Two Shower Rooms | Walls (behind ceramic wall tiles) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG15 | Fowlers Gap Cottage 1 | G | G05 | Bathroom | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG15 | Fowlers Gap Cottage 1 | G | G09 | Far South-West Room, West Side | Wall | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG15 | Fowlers Gap Cottage 1 | G | G11 | South Side, Laundry, Behind Laundry Tub | Wall | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | G01 | Northern Room, East, West and North Sides | Walls | Fibre Cement Sheeting | Positive (Chrysotile) - Removed | Non-friable | Low | P4 | Removed between 26/08/2024 to 31/08/2023 as per Asbestos Clearance Certificate dated 03/09/2024 | Yes |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | G01 | Northern Room | Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) - Removed | Non-friable | Low | P4 | Item removed as per Risktech clearance certificate dated 3/09/2024 | Yes |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | G05 | Bathroom | Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) - Removed | Non-friable | Low | P4 | Item removed as per Risktech clearance certificate dated 3/09/2024 | Yes |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | G06 | Toilet Airlcok | Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) - Removed | Non-friable | Low | P4 | Item removed as per Risktech clearance certificate dated 3/09/2024 | Yes |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | G07 | Toilet | Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) - Removed | Non-friable | Low | P4 | Item removed as per Risktech clearance certificate dated 3/09/2024 | Yes |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | G08 | Laundry | Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) - Removed | Non-friable | Low | P4 | Item removed as per Risktech clearance certificate dated 3/09/2024 | Yes |
FSFG | Fowlers Gap Field Station | FG5 | Fowlers Gap Cottage 2 | G | G03 | Laundry | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG5 | Fowlers Gap Cottage 2 | G | G04 | Store | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG5 | Fowlers Gap Cottage 2 | G | G05 | Former Shower & Toilet | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG5 | Fowlers Gap Cottage 2 | G | G06 | Bathroom | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 138A | Biolink | Ceiling Tiles | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 252 | Biolink, Former Room 215 & 252 | Ceiling Tiles | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 241D | Biolink, | Walls & Ceiling Tiles | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
FSFG | Fowlers Gap Field Station | FG1 | Fowlers Gap Solarch House | G | - | Interior, Throughout House | Flooring | Compressed Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG1 | Fowlers Gap Solarch House | G | UCA | Exterior, Carport, West & South Side | Wall | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Removed between 26/08/2024 to 31/08/2023 as per Asbestos Clearance Certificate dated 03/09/2024 | Yes |
FSFG | Fowlers Gap Field Station | FG1 | Fowlers Gap Solarch House | G | G12 | Exterior, Southern Store Room (exterior walls) | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Removed between 26/08/2024 to 31/08/2023 as per Asbestos Clearance Certificate dated 03/09/2024 | No |
FSFG | Fowlers Gap Field Station | FG1 | Fowlers Gap Solarch House | G | G12 | Southern Store Room Adjacent Carport (internal walls) | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Removed between 26/08/2024 to 31/08/2023 as per Asbestos Clearance Certificate dated 03/09/2024 | No |
FSFG | Fowlers Gap Field Station | FG1 | Fowlers Gap Solarch House | G | G13 | Exterior, Southern Store Room (exterior walls) | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Removed between 26/08/2024 to 31/08/2023 as per Asbestos Clearance Certificate dated 03/09/2024 | No |
FSFG | Fowlers Gap Field Station | FG1 | Fowlers Gap Solarch House | G | G13 | Southern Store Room Adjacent Carport (internal walls) | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Removed between 26/08/2024 to 31/08/2023 as per Asbestos Clearance Certificate dated 03/09/2024 | No |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | - | Exterior, North Side | Old Sign 'Cottage 4' | Compressed Fibre Cement Sheet | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | GQ2 | Toilet Airlock | Flooring | Compressed Fibre Cement Sheet | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | GQ3 | Bathroom | Flooring | Compressed Fibre Cement Sheet | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | GQ4 | Toilet | Flooring | Compressed Fibre Cement Sheet | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | G05 | Laundry | Flooring | Compressed Fibre Cement Sheet | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | - | Exterior, North Side | Old Sign 'Cottage 3' | Compressed Fibre Cement Sheet | Positive (Chrysotile) - Removed | Non-friable | Low | P4 | Item removed as per Risktech clearance certificate dated 3/09/2024 | Yes |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | G05 | Bathroom | Flooring | Compressed Fibre Cement Sheet | Positive (Chrysotile) - Removed | Non-friable | Low | P4 | Item removed as per Risktech clearance certificate dated 3/09/2024 | Yes |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | G06 | Toilet Airlcok | Flooring | Compressed Fibre Cement Sheet | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | G07 | Toilet | Flooring | Compressed Fibre Cement Sheet | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | G08 | Laundry | Flooring | Compressed Fibre Cement Sheet | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 241 | Biolink, | Walls | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 252 | Biolink, Former Room 251, 252 & 253 | Walls | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 252 | Biolink, Former Room 251 | Ceiling Tiles | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG11 | Biosciences North | On Concrete Floor Slab (beneath floor covering) | Bituminous Adhesive | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG11B | Biosciences North | On Concrete Floor Slab (beneath floor covering) | Bituminous Adhesive | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG13 | Biosciences North | On Concrete Floor Slab (beneath floor covering) | Bituminous Adhesive | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG29 | Biosciences North | On Concrete Floor Slab (beneath floor covering) | Bituminous Adhesive | Assumed Positive - Removed | - | - | - | Item Assumed Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 140 | Biolink | Walls | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 356 | Biolink | Fire Door | Insulation Core | Assumed Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | R01 | Plant Room, East, Near SE Corner (on top of electrical cabinet) | Debris | Insulation | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | R01 | Plant Room, East, Near SE Corner (above electrical cabinet) | Soffit Penetration | Mastic Sealant | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | R01 | Plant Room, West Side, NW Corner | Hydrant Water Tank, Panel Joints | Mastic Sealant | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 252 | Biolink, West | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G23A | Biolink, South | Wall | Plasterboard Sheeting | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | G01 | Kitchen | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | GQ2 | Toilet Airlock | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | GQ2 | Toilet Airlock | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | GQ3 | Bathroom | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | GQ3 | Bathroom | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | GQ4 | Toilet | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | GQ4 | Toilet | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | G05 | Laundry | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | G05 | Laundry | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | - | Exterior, All Sides | Walls | Profiled Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | G16 | Near Northern End, Recreational Room | Floor Covering | Vinyl Tiles (suspected beneath vinyl sheeting) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | G16A | Near Northern End, Store Room off Recreational Room | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | G16A | Near Northern End, Store Room off Recreational Room | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | G02 | Kitchen Adjoining Far Southrern Room | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | G03 | Far Southern Accommodation Room | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | G04 | Far SE Corner, Bathroom | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | G05 | Near SE Corner, Laundry | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | G05A | Near SE Corner,Linen Cupboard Adjoining Laundry | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | G16 | Near Northern End, Recreational Room | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | - | Exterior, Subfloor Space | On Ground Surface | Fibre Cement Sheet Debris | Assumed Positive | Non-friable | Low-Med | P3 | Restrict access to the sub floor space to authorised personnel only. Remove fibre cement debris under controlled conditions by a Class A/B Contractor or competent person prior to demolition or refurbishment or when access is required. | No |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | - | Exterior, Subfloor Space | On Ground Surface | Fibre Cement Sheet Debris | Positive (Chrysotile) - Removed | Non-friable | Med | P3 | Item removed as per Risktech clearance certificate dated 3/09/2024 | Yes |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | - | Exterior, Subfloor Space | On Ground Surface | Fibre Cement Sheet Debris | Assumed Positive | Non-friable | Med | P3 | Restrict access to the sub floor space to authorised personnel only. Remove fibre cement debris under controlled conditions by a Class A/B Contractor or competent person prior to demolition or refurbishment or when access is required. | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | - | Exterior, Subfloor Space | On Ground Surfaces | Fibre Cement Sheet Debris | Assumed Positive | Non-friable | Low | P3 | Restrict access to the sub floor space to authorised personnel only. Remove fibre cement debris under controlled conditions by a Class A/B Contractor or competent person prior to demolition or refurbishment or when access is required. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 2Q7 | Biolink, East (walls common to Room 241, 244 & 252) | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D14 | UNSW Hall | G | EAGQ02 | GQ6 Corridor, Electrical Cupboard (DB-2) | Conduits x 2 | Moulded Fibre Cement | Assumed Positive | - | - | - | Item removed. Refer Airsafe clearance cert dated 7/2/2023 | Yes |
KENE | Kensington Environs | AS20 | 20 Arthur Street | G | - | Exterior, Garage, North and South | Gable | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS10 | 10 Arthur Street | G | GQ4 | Exterior, Garage, North | Gable End | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS8 | 8 Arthur Street | G | - | Exterior, Garage, West | Wall Cladding | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS8 | 8 Arthur Street | G | - | Exterior, Garage, South Wall to WR41 | Wall Cladding | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS4 | 4 Arthur Street | G | G12 | Exterior, Garage, South | Wall to WR41 | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS4 | 4 Arthur Street | G | G12 | Garage | Dividing Wall | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G08/G08A | East, Cupboard | Wedged Between Timber Wall & Ceiling Framework | Fibre Cement Sheet Remnants (sealed) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | LG | LG1 | Plant Room | Air Conditioning Ductwork Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | 2 | - | Throughout, Above Stage & Roof Space | Ductwork Flange Joints (beneath insulation & foil) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | LG | LGQ03 | Air Conditioning Plant Room | Air Handling Unit, Panel Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | LG | LGQ06 | Air Conditioning Plant Room | Air Handling Unit, Panel Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | LG | - | South West Plant Room | Air Handling Units, Panel Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | 130A | Plant Room | Air Handling Unit, Panel Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 15 | 1501 | Plant Room | Air Handling Units, Panel Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 2Q7 | Biolink, West (walls common to Room 262, 263 & 264) | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q12 | Biolink, Outside Room 143 | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 143 | Biolink, | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 264 | Biolink, | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 261 | Biolink, | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 272 | Biolink, | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 262A | Biolink,North, South, East & West | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 262 | Biolink, | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 263 | Biolink, | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 137A | Biolink, North, South & East | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 137B | Biolink, North & South | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | R01 | Plant Room, West Side, Near SW Corner | Base of Green Tank | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 138A | Biolink | Floor Covering | Vinyl Floor Tiles (green coloured) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 259 | Biolink | Steel Beams | Insulation | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 449 | Biolink | Steel Beams | Insulation | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | GQ13 | Biolink | Floor Covering | Vinyl Floor Tiles (green coloured) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 134 | Biolink | Floor Covering | Vinyl Floor Tiles (green coloured) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q12 | Biolink | Floor Covering | Vinyl Floor Tiles (green coloured) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 260 | Biolink | Floor Covering | Vinyl Floor Tiles (green coloured) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 272 | Biolink | Floor Covering | Vinyl Floor Tiles (green coloured) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 2Q7 | Biolink | Floor Covering | Vinyl Floor Tiles (green coloured) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 341 | Biolink | Floor Covering | Vinyl Floor Tiles (green coloured) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 342 | Biolink | Floor Covering | Vinyl Floor Tiles (mustard coloured) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 138 | Biolink | Floor Covering (beneath carpet) | Vinyl Floor Tiles (green coloured) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | R01 | Plant Room | Old Air Conditioning Ductwork | Gasket | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 450 | Biolink, | Debris | Fibre Cement Sheeting | Positive (Chrysotile) - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | 6Q3 | Electrical Riser Cupboard | Cable | Positive (Chrysotile) - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes | |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | GQ13 | Biolink, | Fire Door (tagged 'Inglis, 1990') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q13 | Biolink, | Fire Door (tagged 'Inglis, 1990') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 2Q10 | Biolink, | Fire Door (tagged 'Inglis, 1990') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 343 | Biolink | Fire Door (tagged ' Bismac 2006) | Insulation Core | Suspected Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350 | Biolink | Fire Door (tagged ' Bismac 2006) | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 360 | Biolink | Fire Door (tagged ' Bismac 2006) | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q8 | Biolink, | Fire Door (tagged ' Inglis 1990') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q6 | Biolink, | Fire Door (tagged 'Inglis, 1990') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q6 | Biolink, | Fire Door (tagged 'Nismac 2006') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q8 | Biolink, | Fire Door (tagged ' Inglis 1990') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 552B | - | Fire Door (tagged ' Fire Door Replacement Service 1996') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 554 | - | Fire Door (tagged ' Bismac 2005') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q8 | - | Fire Door (tagged ' TDF 2014') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q9 | - | Fire Door (tagged ' TDF 2014') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | RQ12 | - | Fire Door (tagged ' Inglis 1990') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG30 | Biosciences North, Plant Room | Old Plant Items & Hot Water Pipework, Flange Joints | Gaskets | Removed -Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. Note: Hot water vessel and associated hot water pipework removed | Yes |
KENC | Kensington Campus | F20 | Goodsell | 01 | - | Throughout, All Rooms | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G - 03 | - | Exterior, North Side, Near Centre | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 6 | 6Q01 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 6 | 610 | Under Carpet | Floor Covering | Vinyl Floor Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 4Q02 | Under Carpet | Floor Covering | Vinyl Floor Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 4Q05 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401A | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401B | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401C | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401D | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401E | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401F | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401G | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401H | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401I | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401J | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401K | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 402 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 403 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 405 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 406 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 407 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 408 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 409 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 410 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 412 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 412A | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 412B | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 412C | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 412D | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 412E | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 5Q03 | Cleaners Cupboard | Floor Covering | Vinyl Floor Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501A | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501B | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501C | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501D | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501E | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501F | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501G | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501H | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501I | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501J | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501K | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501L | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501M | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 502 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 503 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 504 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 505 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 506 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 507 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 508 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 510 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 510A | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 510B | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 510C | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 510D | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 111 | - | On Top of Blockwork Walls | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 182 | - | On Top of Blockwork Walls | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 183 | - | On Top of Blockwork Walls | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q8 | - | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q12 | - | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q13 | - | On Top of Blockwork Walls | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q19 | - | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 209A | - | Floor & Soffit Expansion Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q3 | - | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q4 | - | Floor & Soffit Expansion Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q4 | - | Walls, Floor & Soffit Expansion Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q5 | - | Floor & Soffit Expansion Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q8 | - | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q10 | - | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q14 | - | On Top of Blockwork Walls | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q27 | - | Floor & Soffit Expansion Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 301 | North (internal & external) | Surrounding Window Framework | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 302 | North (internal & external) | Surrounding Window Framework | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 303 | North (internal & external) | Surrounding Window Framework | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 306 | North (internal & external) | Surrounding Window Framework | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 310 | - | Floor & Soffit Expansion Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q2 | - | Floor & Soffit Expansion Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q2 | Room M3Q01 off Room 3Q2 | Wall, Floor & Soffit Expansion Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q4 | - | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q5 | North (internal & external) | Surrounding Window Framework | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q6 | - | Floor & Soffit Expansion Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q10 | - | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q19 | - | Walls, Floor & Soffit Expansion Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 6Q2 | South & West | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q4 | South & West | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q7 | South & West | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 7Q2 | South & West | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | - | Throughout | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 10Q2 | South & West | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | - | Throughout | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 8Q6 | South & West | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 9Q2 | South & West | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 9Q3 | North & East | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | - | Throughout | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 11Q3 | North & East | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 209 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 209A | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 210 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 214 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 226 | South (behind plasterboard wall) | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 227 | South & West (behind plasterboard wall) | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 228 | West (behind plasterboard wall) | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 229 | West | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 307 | North & South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 308 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 309 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 310 | South & North (behind timber panelling) | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 311 | South & North (behind timber panelling) | Vertical Expansion Wall Joints | Sealant Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 312 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive - removed | - | - | - | Item removed. Refer Airsafe clearance cert dated 13-17/10/23 | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 317 | South, West & East | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 401 | North | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 404 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 405 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 407 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 408 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 409 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 409A | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 409E | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 411F | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 411H | South | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 411K | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 411F | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 411F | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 415A | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 415B | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 415E | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 415F | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 501 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 503 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 504 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 506B | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 506C | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 508 | North | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 509 | North | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 511 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 512 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 513 | East | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 513A | East | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 513B | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 514 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 515 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 517 | South | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 517D | South | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 518 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q15 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 603 | North & West | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 604 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 606 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 608 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 608B | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 610 | North | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 611 | North | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 613 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 613A | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 615 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 615A | East | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 615B | East | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 615C | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 619 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 621 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 622C | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 622D | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 701 | North & West | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 703 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 705 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 707 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 710 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 713 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 714 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 716 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 717 | East | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 718D | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 719B | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 720 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 721 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 721A | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 722E | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 723E | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 801 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 802 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 804 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 806 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 808 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 810 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 812 | North | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 813 | North | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 814 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 816 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 817 | South & East | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 818C | South | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 818D | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 819 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 823 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 825 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 826 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 827A | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 901 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 902 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 904 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 906 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 907 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 910 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 912 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 914 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 915 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 917 | East | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 918 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 919 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 921A | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 926 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 927 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 928 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 929 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1001 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1002 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1004 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1006 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1008 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1010 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1012 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1013 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1014 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1015 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1016A | East | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1016C | East | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1017D | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1018D | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1018E | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1020 | South | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1021C | South | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1022E | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1023D | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1101 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1101A | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1103 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1105 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1106 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1107 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1109 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1111 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1112 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1113 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1113 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1113A | East | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1113C | East | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1113D | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1114 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1120 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1121 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1123 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1125 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1201 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1202 | North | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1204 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1206 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1208 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1209 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1211 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1213 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1215 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1216 | South & East | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1218 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1224 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1225 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1226 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 12Q3 | North & East | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1301 | West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1302 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1303 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1305 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1306 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1307 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1310 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1312 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1314 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1315 | South & East | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1315A | East | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1315B | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1316B | South | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1319 | South | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1322 | South | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1323 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1333 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1339 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 13Q3 | North & East | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Asumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | - | Throughout | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | - | Throughout | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | - | Throughout | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | - | Throughout | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | - | Throughout | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 14Q3 | North & East | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 181 | Substation No.10, NE Entry & Airlock | Fire Doors (tagged 'Metabilt') | Core Insulation | Removed - Assumed Positive | - | - | - | Items Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire doors tagged 'Bismac Fire Doors, 2021'. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q17 | South | Fire Door (tagged 'Metabilt') | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q4 | - | Fire Door (no tag) | Core Insulation | Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | M4Q01 | Service Duct off Room 4Q5 | Fire Door (tagged 'Metabilt') | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q10 | - | Fire Door (no tag) | Core Insulation | Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q12 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 520 | Service Duct Entry off Room 520 | Fire Door (tagged 'Metalbilt') | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q7 | - | Fire Door (no tag) | Core Insulation | Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q10 | Service Duct off Room 5Q10, Toilets | Fire Door (no tag) | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 620 | Plant Room | Fire Door (tagged 'Metalbilt') | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 7Q7 | Service Duct off Room 7Q7, Toilets | Fire Door (tagged 'Metalbilt') | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 8Q10 | Service Duct off Room 8Q10, Toilets | Fire Door (tagged 'Metalbilt') | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 923 | Service Duct off Room 923, Toilets | Fire Door (tagged 'Metalbilt') | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 10Q7 | Service Duct off Room 10Q7, Toilets | Fire Door (tagged 'Metalbilt') | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 11Q7 | Service Duct off Room 11Q7, Toilets | Fire Door (tagged 'Metalbilt') | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1221 | Service Duct off Room 1221, Toilets | Fire Door (tagged 'Metalbilt') | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 13Q9 | Service Duct Entry off Room 13Q9, Toilets | Fire Door (tagged 'Metalbilt') | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 14Q7 | Service Duct off Room 14Q7, Toilets | Fire Door (tagged 'Metalbilt') | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1620 | Service Duct Entry off Room 1620, Toilets | Fire Door (tagged 'Metalbilt') | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 1402 | North, South & East | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 1404 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 1406 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 1407 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 1408 | North & West | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1501 | North & West | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1502 | North & South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1503 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1505 | North | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1506 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1507 | North | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1508 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1509 | East | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1510 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1510A | South | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1511 | South | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1512 | South | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1629 | North & West (Former Room 1601) | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1602A | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1604 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1606 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1609 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1610 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1612 | North | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1613 | East | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1615 | East | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1616 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1618 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1622 | South | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1625 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1626 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1627 | South | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 16Q1 | - | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P3 | Remove deteriorating mastic sealant in vertical joint in north wall and consider sealing the mastic sealant in other walls under controlled conditions by a Class A/B contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 16Q2 | West & South | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 16Q3 | North & East | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 16Q5 | Lift Lobby Outside Fire Stairs 16Q1 | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 17 | 1701 | North, East & West | On Top of Blockwork Walls | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 17 | 1703 | West | On Top of Blockwork Wall | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 17 | 17Q01 | West, North & South | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 18 | 1802 | North & East | On Top of Blockwork Walls | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 18 | 1803 | West | On Top of Blockwork Wall & Vertical Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 18 | 18Q01 | All Sides | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 15Q4 | East | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 15Q2 | South & West | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 15Q3 | North & East | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | - | Throughout | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | ELGQ02 | Biolink, Former Electrical Riser Cupboard off Room LGQ11 | Beneath & Behind Electrical Cabinet (suspected) | Packing Insulation | Suspected Positive | Friable | Low | P3 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | - | Biosciences North, Undercroft, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | - | Biosciences North, East Bookend Riser, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | - | Biosciences North, West Bookend Riser, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG024 | Biosciences North, Ancillary Store A, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG03 | Biosciences North, Main Geo Store, Northern and Western Structural Walls | Conduits (Tubes) | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG04 | Biosciences North, Glasswash, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG05 | Biosciences North, Ancillary Store B, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG014 | Biosciences North, Rock Crush, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG016 | Biosciences North, Main Stores, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LGQ03 | Biosciences North, Substation, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LGQ04 | Biosciences North, AHU, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LGQ06 | Biosciences North, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LGQ07 | Biosciences North, Plant, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LGQ08 | Biosciences North, Plant, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LGQ09 | Biosciences North, Stair, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LGQ10 | Biosciences North, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LGQ11 | Biosciences North, Plant, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LGQ13 | Biosciences North, Substation, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LGLS150 | Biosciences North, Goods Lift, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | ELGQ04 | Biosciences North, Elec, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | MLGQ01 | Biosciences North, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G06A | Biosciences North, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G07 | Biosciences North, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G09 | Biosciences North, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | GQ03 | Biosciences North, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | GQ07 | Biosciences North, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | GQ15 | Biosciences North, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | GQ20 | Biosciences North, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | GQ50 | Biosciences North, East Riser 1, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | GQ51 | Biosciences North, East Riser 1, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | GLS150 | Biosciences North, West Riser A, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | MGQ01 | Biosciences North, Mech Plant, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | MGQ03 | Biosciences North, Plant, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MISC | Miscellaneous | BC34 | Woolley House | - | - | Exterior, Various Location | Windows (between glass & internal timber framework) | Caulking Mastic | Assumed Positive | Non-friable | Low | P3 | Repair or remove deteriorating window caulking under controlled conditions by a Class A/B contractor or competent person within a planned control programs. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | MGQ05 | Biosciences North, Riser D, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | MGQ06 | Biosciences North, West Riser A, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | MGQ07 | Biosciences North, Mech Riser F, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | MGQ08 | Biosciences North, Riser F, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | MGQ09 | Biosciences North, Mech Riser, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
FSFG | Fowlers Gap Field Station | FG5 | Fowlers Gap Cottage 2 | G | G04 | Store | Floor Covering | Vinyl Tiles (grey colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG5 | Fowlers Gap Cottage 2 | G | G05 | Former Shower & Toilet | Floor Covering | Vinyl Tiles (grey colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | EGQ01 | Biosciences North, Elec, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 01 | 102 | Gymnasium (B5), Throughout | Window Frames (between frame and pane) | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status and if contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | AS10 | 10 Arthur Street | G | - | Exterior, North and South | Gable | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | EGQ02 | Biosciences North, Elec, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | EGQ03 | Biosciences North, Main Switchroom, Eastern Structural Wall | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G2 | - | Floor Covering | Vinyl Floor Tiles (beneath carpet tiles) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G3 | - | Floor Covering | Vinyl Floor Tiles (beneath carpet tiles) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G4 | - | Floor Covering | Vinyl Floor Tiles (beneath carpet tiles) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G5 | - | Floor Covering | Vinyl Floor Tiles (beneath carpet tiles) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G6 | - | Floor Covering | Vinyl Floor Tiles (beneath carpet tiles) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G7 | - | Floor Covering | Vinyl Floor Tiles (beneath vinyl sheeting & screed - cement based levelling compound) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G7 | Electrical Cupboard | Floor Covering | Vinyl Floor Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G16 | - | Floor Covering | Vinyl Floor Tiles (beneath carpet tiles) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G22 | - | Floor Covering | Vinyl Floor Tiles (beneath carpet) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | O14 | Kangas House | G | - | Exterior, Eastern Building, Outside Rooms 50 - 53 & 60 - 63 | Eaves | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q4 | - | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | FGQ02 | Biosciences North, FHR, Southern Structural Wall | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | O14 | Kangas House | G | 1 | Northern Side, Adjacent Skylights | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | O14 | Kangas House | G | 1A | Northern Side, Adjacent Skylights | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | O14 | Kangas House | G | 2 | Northern Side, Adjacent Skylights | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | O14 | Kangas House | G | 2A | Northern Side, Adjacent Skylights | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | O14 | Kangas House | G | 8 | Northern Side, Adjacent Skylights | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | O14 | Kangas House | G | 8A | Northern Side, Adjacent Skylights | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | G | G8C | - | Ductwork Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | G | G10E | - | Ductwork Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 121A | Toilets, Ceiling Space | Ductwork Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 121B | Plant Room (off Toilets) | Ductwork Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | M1Q01 | Plant Room | Ductwork Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 2Q08 | Toilets, Ceiling Space | Ductwork Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 2Q10 | Toilets, Ceiling Space | Ductwork Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 2Q11 | Plant Room (off Toilets) (Note: Door to room noted as 221B) | Ductwork Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 101 | North | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 105 | North | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 106 | North | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 107 | North | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 108 | North | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 109 | North, Behind New Window Panelling | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 110 | North, Behind New Window Panelling | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 111 | North, Behind New Window Panelling | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 113 | East & South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 114 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 115 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 116 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 117 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 117A | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 118 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 120A | Toilets, Ceiling Space | Ductwork Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 122 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 123 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 124 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 125 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 201 | North | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 202 | North | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 203 | North | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 205 | North, Behind New Window Panelling | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 206 | North, Behind New Window Panelling | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 207 | North, Behind New Window Panelling | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 208 | North, Behind New Window Panelling | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 209 | East, Behind New Window Panelling | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 210 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 211 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 212 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 213 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 214 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 215 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 216 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 217 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 218 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 219 | South | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 221A | North | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 2Q03 | East | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 2Q05 | North | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | - | - | Exterior | Window Beading | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 221B | Plant Room | Ductwork Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 414 | - | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | G04 | Kitchen, South and East Sides | Walls | Fibre Cement Sheeting | Positive (Chrysotile) - Removed | Non-friable | Low | P4 | Removed between 26/08/2024 to 31/08/2023 as per Asbestos Clearance Certificate dated 03/09/2024 | Yes |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | G05 | Bathroom | Walls | Fibre Cement Sheeting | Positive (Chrysotile) - Removed | Non-friable | Low | P4 | Removed between 26/08/2024 to 31/08/2023 as per Asbestos Clearance Certificate dated 03/09/2024 | Yes |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | G06 | Toilet Airlcok | Walls | Fibre Cement Sheeting | Positive (Chrysotile) - Removed | Non-friable | Low | P4 | Removed between 26/08/2024 to 31/08/2023 as per Asbestos Clearance Certificate dated 03/09/2024 | Yes |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | G07 | Toilet | Walls | Fibre Cement Sheeting | Positive (Chrysotile) - Removed | Non-friable | Low | P4 | Removed between 26/08/2024 to 31/08/2023 as per Asbestos Clearance Certificate dated 03/09/2024 | Yes |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | G08 | Laundry | Walls | Fibre Cement Sheeting | Positive (Chrysotile) - Removed | Non-friable | Low | P4 | Removed between 26/08/2024 to 31/08/2023 as per Asbestos Clearance Certificate dated 03/09/2024 | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 208 | Duct | Fire Door | Core Insulation | Assumed Positive | Friable | Low | P3 | Remedial works should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q14 | - | Fire Door (tagged 'Bismac, 2021) | Core Insulation | Negative | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 19 December 2021. Note: New fire door tagged 'Bismac Fire Doors, 2021'. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | FGQ03 | Biosciences North, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | HGQ01 | Biosciences North, Hyd Plant, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | GQ13 | Bilolink, | Beneath & Behind Electrical Cabinet | Packing Insulation | Suspected Positive | Friable | Low | P3 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 102 | Biosciences North, Wet Teaching Lab 09, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | LG | LG13A | Plumbling Duct Adjacent Room LG13A Toilets | Pipework | Insulation | Assumed Positive - Removed | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 3 September 2007 (Ref: 59392). | Yes |
KENC | Kensington Campus | F20 | Goodsell | G | GQ6A | Plumbing Duct Adjacent Room G24A Toilets | Pipework | Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 3 September 2007 (Ref: 59392). | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 104 | Biosciences North, Comms, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 106 | Biosciences North, Anatomy Lab 1, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q12 | Biolink, Electrical Riser Cupboard | Beneath & Behind Electrical Cabinet | Packing Insulation | Suspected Positive | Friable | Low | P3 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q02 | Biosciences North, Structural Walls Surrounding 1Q20 Gas Manifold | Conduits (Tubes) | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q11 | Biosciences North, Southern Structural Wall and Walls Surrounding Lift Shaft | Conduits (Tubes) | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q20 | Biosciences North, Gas Manifold, All Structural Walls | Conduits (Tubes) | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q50 | Biosciences North, East Riser 1, Structural Walls | Conduits (Tubes) | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q51 | Biosciences North, West Riser A, Structural Walls | Conduits (Tubes) | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | E1Q02 | Biosciences North, Elec, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | F1Q03 | Biosciences North, Fire/SF, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | M1Q02 | Biosciences North, Plant, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | M1Q05 | Biosciences North, Plant, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | M1Q07 | Biosciences North, Mech Riser F, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | M1Q09 | Biosciences North, Mech Riser F, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | M1Q14 | Biosciences North, Mech Riser D, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | L1LS | Biosciences North, Goods Lift, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 201A-201E | Biosciences North, Offices, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 202 | Biosciences North, Comms | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 219 | Biosciences North, Comms | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 220A-220E | Biosciences North, Offices | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 220 | Biosciences North, Offices | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 2Q7 | Biolink, Electrical Riser Cupboard | Beneath & Behind Electrical Cabinet | Packing Insulation | Suspected Positive | Friable | Low | P3 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 2Q20 | Biosciences North, Gas Manifold, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 2Q50 | Biosciences North, East Riser 1, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 2Q51 | Biosciences North, West Riser A, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | LG | LG24A | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 8 April 2019. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG26 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 8 April 2019. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG27 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 8 April 2019. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG29 | South & West Sides, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 8 April 2019. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG30 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 8 April 2019. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG28 | East Side, South Wall | On Vertical Metal Plate Strip | Sealant Mastic (brown colour) | Assumed Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 8 April 2019. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LGQ12 | - | Floor Covering | Vinyl Floor Tiles (beige colour) | Assumed Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 8 April 2019. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG24 | - | Floor Covering | Vinyl Floor Tiles (beige colour) | Assumed Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 8 April 2019. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG24A | - | Floor Covering | Vinyl Floor Tiles (beige colour) | Assumed Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 8 April 2019. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG25 | - | Floor Covering | Vinyl Floor Tiles (beige colour) | Assumed Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 8 April 2019. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG26 | - | Floor Covering | Vinyl Floor Tiles (beige colour) | Assumed Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 8 April 2019. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG27 | - | Floor Covering | Vinyl Floor Tiles (beige colour) | Assumed Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 8 April 2019. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG30 | Southern Section | Floor Covering | Vinyl Floor Tiles (beige colour) | Assumed Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 8 April 2019. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | MLG Q02 | Service Tunnel off Room LG5 | On Brick Wall | Insulation Residue | Assumed Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 15 April 2019. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 2Q8 | - | Floor Covering | Vinyl Tiles (brittle blue colour) | Assumed Positive (Removed) | - | - | - | Item Removed 29/4/2019 by Pure Contracting. Refer to RiskTech Clearance Certificate dated 29/4/2019. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | 172 | Toilet | Ceiling Tiles | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | 173 | Toilet | Ceiling Tiles | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | 174 | Toilet | Ceiling Tiles | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 2 | 2Q24 | Toilet (former Room 234) | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 2 | 2Q25 | Toilet (former Room 234A) | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 3 | 3Q23 | Toilet (former Room 318) | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 3 | 3Q24 | Toilet (former Room 318A) | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 4 | 499 | Toilet | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 11 | - | Roof Area, SW Corner | Roof | Bituminous Membrane Debris | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 11 | 1199 | Toilet | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 5 | 599 | Toilet | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 5 | 599A | Toilet | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 6 | 699 | Toilet | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 6 | 699A | Toilet | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 7 | 799 | Toilet | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to Airsafe Clearance Certificate (Ref: 25125) dated 31 October 2014. | Yes |
KENC | Kensington Campus | F21 | Library | 7 | 799A | Toilet | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to Airsafe Clearance Certificate (Ref: 25125) dated 31 October 2014. | Yes |
KENC | Kensington Campus | F21 | Library | 8 | 899 | Toilet | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to Airsafe Clearance Certificate (Ref: 25125) dated 31 October 2014. | Yes |
KENC | Kensington Campus | F21 | Library | 8 | 899A | Toilet | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to Airsafe Clearance Certificate (Ref: 25125) dated 31 October 2014. | Yes |
KENC | Kensington Campus | F21 | Library | 9 | 999 | Toilet | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 10 | 1099 | Toilet | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 12 | 1299 | Toilet | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 12 | 1299A | Toilet | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 13 | 1399 | Toilet | Ceiling | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 14 | 1499 | Toilet | Ceiling | Fibre Cement Sheeting | Removed - Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 820 | (Previously Rooms 817, 818, 819 B-L) Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Removed - Assumed Positive | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 822 | (Previously Rooms 817, 818, 819 B-L) Under New Flooring | Floor Covering | Vinyl Tiles | Removed - Assumed Positive | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 823 | (Previously Rooms 817, 818, 819 B-L) Under New Flooring | Floor Covering | Vinyl Tiles | Removed - Assumed Positive | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 824 | (Previously Rooms 817, 818, 819 B-L) Under New Flooring Covering | Floor Covering | Vinyl Tiles | Removed - Assumed Positive | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | E2Q01 | Biosciences North, Elec, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | G | G08 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive - Removed | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | K17 | Building K17 | G | G07 | Under Carpet | Floor Covering | Vinyl Tiles | Assumed Positive - Removed | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 1 | 1Q02 | Cleaners Cupboard | Floor Covering | Vinyl Tiles (brown colour) | Assumed Positive - Removed | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
DPFS | David Phillips Field | DP4 | Grounds Depot | G | G02 | Shower | Wall Lining | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed by Pure Contracting on 15/8/2017. Refer to RiskTech Clearance Report dated 15/08/2017. | Yes |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G03 | Under Carpet | Floor Covering | Vinyl Tiles (light green colour) | Assumed Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G04 | Under Carpet | Floor Covering | Vinyl Tiles (light green colour) | Assumed Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G05 | Under Carpet | Floor Covering | Vinyl Tiles (light green / beige colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | Yes |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G06 | Under Carpet | Floor Covering | Vinyl Tiles (light green colour) | Assumed Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G07 | Under Carpet | Floor Covering | Vinyl Tiles (light green colour) | Assumed Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G08 | Under Carpet | Floor Covering | Vinyl Tiles (light green colour) | Assumed Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G09 | Under Carpet | Floor Covering | Vinyl Tiles (light green colour) | Assumed Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G1Q | Under Carpet | Floor Covering | Vinyl Tiles (light green colour) | Assumed Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | E2Q02 | Biosciences North, Elec, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | F2Q01 | Biosciences North, FHR, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | F2Q03 | Biosciences North, Fire Riser, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | L2LS | Biosciences North, Goods Lift, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | M2Q02 | Biosciences North, Plant, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | M2Q05 | Biosciences North, Plant, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | M2Q07 | Biosciences North, Mech Riser F, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | M2Q09 | Biosciences North, Mech Riser F, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | M2Q14 | Biosciences North, Mech Riser D, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q03 | Fire Hose Cupboard | Floor Covering | Vinyl Tiles | Assumed Positive - Removed | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G07 | - | Floor Covering | Vinyl Tiles (green colour) | Assumed Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 146A | - | Floor Covering | Vinyl Tiles (grey colour) | Assumed Positive (Removed) | - | - | - | Item Removed 21/11/2015. Refer to Airsafe Asbestos Clearance Certificate dated 23/11/2015 (report reference: 29259). | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 149 | - | Floor Covering | Vinyl Tiles (grey colour) | Assumed Positive (Removed) | - | - | - | Item Removed 14/1/2017. Refer to RiskTech Clearance Certificate dated 14/1/2017. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 150 | - | Floor Covering | Vinyl Tiles (grey colour) | Assumed Positive (Removed) | - | - | - | Item Removed 14/1/2017. Refer to RiskTech Clearance Certificate dated 14/1/2017. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 151 | - | Floor Covering | Vinyl Tiles (grey colour) | Assumed Positive (Removed) | - | - | - | Item Removed 21/1/2017. Refer to RiskTech Clearance Report dated 21/1/2017. | Yes |
KENC | Kensington Campus | K15 | Old Main | G | G45 | - | Air Conditioning Ductwork Heater Bank | Insulation Board | Assumed Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 134C | - | Air Conditioning Ductwork Heater Bank | Insulation Board | Assumed Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. Room no longer present or relocated. | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG8 & LG8A | Throughout | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed 10/8/2013 by Pure Contracting - NAA Clearance Certifcate (Ref: C107859:J121395) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | G | G5 | Throughout | Floor Covering | Vinyl Tiles (Blue & Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed 23/8/2008 by Cardinal Project Services - NAA Clearance Certificate (Ref: SU0013:68084) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | G | G7 | Throughout | Floor Covering | Vinyl Tiles (Blue Colour) | Assumed Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 201 | Throughout (beneath carpet) - Previously 201A & 201B | Floor Covering | Vinyl Tiles (Aqua & Grey Colour) | Assumed Positive - Removed | - | - | - | Item removed 14/2/2008 by Cardinal Project Services - NAA Clearance Certificate (Ref: SU0013:55783-H20) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 111, 111A, 111B | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed 10/7/2010 by Cardinal Project Services - NAA Clearance Certificate (Ref: SS0263:77747) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 112 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed 23/3/2019 by Pure Contracting - RiskTech Clearance Certifcate dated 25/3/2019 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 113 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed 1/10/2010 by Cardinal Project Services - NAA Clearance Certificate (Ref: SS0263:86623) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 114 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed 22/6/2009 by Cardinal Project Services - NAA Clearance Certificate (Ref: SU0013:74610) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 202 | Throughout | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed 23/2/2013 by Pure Contracting - NAA Clearance Certificate (Ref: C107946:J117599) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 204 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed 23/3/2019 by Pure Contracting - RiskTech Clearance Certifcate dated 25/3/2019 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 209 | Throughout | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed 7/7/2012 by Pure Contracting - NAA Clearance Certificate (Ref: C107946:J105057) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 210 & 210A | Throughout | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 211 | Throughout | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed 27/7/2013 by Pure Contracting - NAA Clearance Certificate (Ref: C107946:J121100) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 212 | Throughout | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed 27/7/2013 by Pure Contracting - NAA Clearance Certificate (Ref: C107946:J121100) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 302 | Throughout | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed 5/6/2010 by Cardinal Project Services - NAA Clearance Certificate (Ref: SS0263:77747) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 309 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed 10/3/2012 by Pure Contracting - NAA Clearance Certificate (Ref: C107946:J105057) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 407 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Assumed Positive - Removed | - | - | - | Item removed 30/8/2008 by Cardinal Project Services - NAA Clearance Certificate (Ref: SU0013:68233) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 410 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Assumed Positive - Removed | - | - | - | Item removed 30/8/2008 by Cardinal Project Services - NAA Clearance Certifcate (Ref: SU0013:68233) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 410A & 410B | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Assumed Positive - Removed | - | - | - | Item removed 15/2/2008 by Cardinal Project Services - NAA Clearance Certificate (Ref: SU0013:55783) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 411 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Assumed Positive - Removed | - | - | - | Item removed 17/2/2012 by Pure Contracting - NAA Clearance Certificate (Ref: SS0263:96374) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 412 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Assumed Positive - Removed | - | - | - | Item removed 26/3/2011 by Cardinal Project Services - NAA Clearance Certificate (Ref: SS0263:77747) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 413 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Assumed Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 415 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Blue Colour) | Assumed Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 313 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed 23/2/2013 by Pure Contracting - NAA Clearance Certifcate (Ref: C107946:J117599) | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 507 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 508 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 509 | Throughout (beneath carpet) | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 511 | Throughout | Floor Covering | Vinyl Tiles (Aqua Colour) | Assumed Positive - Removed | - | - | - | Item removed 23/8/2008 by Cardinal Project Services - NAA Clearance Certifcate (Ref: SU0013:68084) | Yes |
KENC | Kensington Campus | F13 | Science Theatre | 1 | 1Q7 | North and South | Wall | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed by Pure Contracting. Refer to RiskTech Clearance Certificate dated 3/6/2017. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | G | - | Exterior, North | Eaves | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | G | Former Room G02H | Throughout | Flue | Moulded Fibre Cement | Assumed Positive - Removed | - | - | - | Item removed 22/03/2014. Refer to NAA Clearance Certificate C107946:J125290. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | G | Former Room G02H | Hot Water Unit and Riser | Pipework | Lagging | Assumed Positive - Removed | - | - | - | Item removed 22/03/2014. Refer to NAA Clearance Certificate C107946:J125290. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | G | Former Room GQ14 | Ceiling Space | Pipework | Lagging and Associated Debris | Assumed Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | 01 | Former Room 114A | Throughout | Pipework | Lagging | Assumed Positive - Removed | - | - | - | Item removed 22/03/2014. Refer to NAA Clearance Certificate C107946:J125290. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | 01 | 1Q6 | Wall Cavity, East Side | Pipework | Lagging | Assumed Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | R | - | - | Pipework | Lagging | Assumed Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | R | - | - | Pipework | Lagging Debris | Assumed Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
Kenc | Kensington Campus | D9 | IO Myers Studio | G | G05 | West | Wall | Fibre Cement Sheeting | Assumed Positive - Removed | - | - | - | Item Removed by Pure Contracting on 19/03/2016. Refer to Greencap Clearance Certificate C107859:J143853 dated 21/03/16. | Yes |
Kenc | Kensington Campus | D16 | Goldstein Hall | 01 | 106 | - | Floor Covering | Vinyl Tiles (black colour) | Assumed Positive (Removed) | - | - | - | Item Removed 21/01/2011. Refer to NAA Clearance Report SS0263:77747. | Yes |
Kenc | Kensington Campus | D16 | Goldstein Hall | 01 | 107 | - | Floor Covering | Vinyl Tiles (black colour) | Assumed Positive (Removed) | - | - | - | Item Removed. No removal documentation provided | Yes |
COFA | Paddington Campus | CFAC | Block C | G | CG13 | Throughout | Ceiling | Fibre Cement Sheeting | Assumed Positive (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | G | CG14 | Throughout | Ceiling | Fibre Cement Sheeting | Assumed Positive (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | G | CG15 | Throughout | Ceiling | Fibre Cement Sheeting | Assumed Positive (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | G | CG16 | Throughout | Ceiling | Fibre Cement Sheeting | Assumed Positive (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | G | CG17 | Throughout | Ceiling | Fibre Cement Sheeting | Assumed Positive (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | G | CGQ1 | South | Ceiling | Fibre Cement Sheeting | Assumed Positive (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | G | CGQ2 | Throughout | Ceiling | Fibre Cement Sheeting | Assumed Positive (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | 02 | C203 | Throughout | Floor Covering | Vinyl Tiles | Assumed Positive (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | 02 | C204 | Throughout | Floor Covering | Vinyl Tiles | Assumed Positive (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | 02 | C206 | Throughout | Floor Covering | Vinyl Tiles | Assumed Positive (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | 02 | C208 | Throughout | Floor Covering | Vinyl Tiles | Assumed Positive (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | 02 | C210 | Throughout | Floor Covering | Vinyl Tiles | Assumed Positive (Removed) | - | - | - | - | Yes |
Kenc | Kensington Campus | C24 | Clancy Auditorium | LG | LG2 | - | Flue | Moulded Fibre Cement | Assumed Positive (Removed) | - | - | - | Item Removed 4/3/2009. Refer to NAA Clearance Certificate SS0263:72214 and Air Monitoring Report 71828.001-003. | Yes |
Kenc | Kensington Campus | C24 | Clancy Auditorium | LG | LG3 | Ceiling Space | Flue | Moulded Fibre Cement | Assumed Positive (Removed) | - | - | - | Item Removed 4/3/2009. Refer to NAA Clearance Certificate SS0263:72214 and Air Monitoring Report 71828.001-003. | Yes |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q8 | Roof Space Access Door | Fire Door | Core Insulation | Assumed Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 1Q5 | Plant Room | Duct Heater Banks x2 | Millboard | Assumed Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 17 | 1704 | - | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | M2Q15 | Biosciences North, Mech Riser D, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 301A-301E | Biosciences North, Offices, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 302 | Biosciences North, Comms | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 319 | Biosciences North, Comms | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 320A-320E | Biosciences North, Comms | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q6 | Biolink, Electrical Riser Cupboard | Beneath & Behind Electrical Cabinet | Packing Insulation | Suspected Positive | Friable | Low | P3 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q10 | Biosciences North, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q20 | Biosciences North, Gas Manifold, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q50 | Biosciences North, East Riser 1, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q51 | Biosciences North, West Riser A, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | E3Q01 | Biosciences North, Elec, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | E3Q02 | Biosciences North, Elec, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | F3Q01 | Biosciences North, FHR, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | F2Q03 | Biosciences North, Fire Riser, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | L3LS | Biosciences North, Goods Lift, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | M3Q02 | Biosciences North, Plant, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | M3Q05 | Biosciences North, Plant, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | M3Q07 | Biosciences North, Mech Riser F, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | M3Q09 | Biosciences North, Mech Riser F, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | M3Q14 | Biosciences North, Mech Riser D, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | M3Q15 | Biosciences North, Mech Riser D, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 401A-401E | Biosciences North, Offices, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 402 | Biosciences North, Comms | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 419 | Biosciences North, Comms | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 420A-420E | Biosciences North, Comms | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q6 | Biolink, Electrical Riser Cupboard | Beneath & Behind Electrical Cabinet | Packing Insulation | Suspected Positive | Friable | Low | P3 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q10 | Biosciences North, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q20 | Biosciences North, Gas Manifold, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q50 | Biosciences North, East Riser 1, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q51 | Biosciences North, West Riser A, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | E4Q01 | Biosciences North, Elec, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | E4Q02 | Biosciences North, Elec, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | F4Q01 | Biosciences North, FHR, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | F4Q03 | Biosciences North, Fire Riser, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | L4LS | Biosciences North, Goods Lift, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 3Q02 | Fire Hose Cupboard | Floor Covering | Vinyl Tiles (dark brown colour) | Assumed Positive - Removed | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 3 | 301 | Communications Cupboard | Floor Covering | Vinyl Tiles (dark brown colour) | Assumed Positive - Removed | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
Kenc | Kensington Campus | G15 | Robert Webster Theatres | 02 | 290A | Lecture Theatre B, East Side, Projector Room, Ceiling Space, Above Ceiling | On Ceiling | Fibre Cement Debris | Assumed Positive (Removed) | - | - | - | Item Removed by Pure Contracting on 10/6/2016. Refer to Greencap Clearance Certificate (C107859/J145185) dated 14/6/18. | Yes |
KENC | Kensington Campus | F13 | Science Theatre | 1 | 1Q7 | Central | Debris | Fibre Cement Sheet | Assumed Positive - Removed | - | - | - | Item Removed by Pure Contracting. Refer to RiskTech Clearance Certificate dated 3/6/2017. | Yes |
KENC | Kensington Campus | F13 | Science Theatre | G | G08 & G08A | East (South Section) & South (East Section) | Walls | Fibre Cement Sheeting | Removed: Assumed Positive | - | - | - | Item Removed by Pure Contracting. Refer to RiskTech Clearance Certificate dated 3/6/2017. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | G | Former Room GQ04 | Surrounding G02, Under Carpet Tiles | Floor Covering | Vinyl Tiles (blue and black colour) | Assumed Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | 01 | Former Rooms 105, 105A, 106, 106A & 106B | Below Purple Carpet and Exposed in Room 106 | Floor Covering | Vinyl Tiles (blue and black colour) | Assumed Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | M4Q02 | Biosciences North, Plant, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
FSFG | Fowlers Gap Field Station | FG15 | Fowlers Gap Cottage 1 | G | - | Exterior, Surrounding Cottage | On Ground Surface | Fibre Cement Sheet Debris | Assumed Positive - Removed | - | - | - | Item Removed: UNSW site personnel informed RiskTech that fibre cement debris removed. RiskTech also removed fibre cement debris as part of the inspection process. | Yes |
FSFG | Fowlers Gap Field Station | FG17 | Fowlers Gap Aviary | G | - | Approximately 20m East of Aviary | On Ground Surface | Fibre Cement Sheet Debris | Assumed Positive - Removed | - | - | - | Item Removed: RiskTech removed fibre cement debris as part of the inspection process. | Yes |
KENC | Kensington Campus | F13 | Science Theatre | G | G08 & G08A | South | Bulkhead | Fibre Cement Sheeting | Removed: Assumed Positive | - | - | - | Item Removed by Pure Contracting. Refer to RiskTech Clearance Certificate dated 3/6/2017. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 4 | 4Q02 | Communications Riser Cupboard (under carpet) | Floor Covering | Vinyl Floor Tiles | Removed - Assumed Positive | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG13B | Cleaners Room/Store | Pipework | Insulation | Assumed Positive - Removed | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 3 September 2007 (Ref: 59392). | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q8 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 730 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate dated 16 March 2015 (Ref: J131981.002). Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 731 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate dated 16 March 2015 (Ref: J131981.002). Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 6Q2 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 6Q3 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 7Q2 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 10Q2 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 11Q3 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q7 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q7 | Plant Room | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 14Q3 | - | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 16Q2 | - | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 16Q3 | - | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 16 | - | Corridor | Air Conditioning Ductwork Heater Unit | Millboard Insulation Board | Removed -Assumed Positive | - | - | - | Item Removed: NAA Clearance Certificate dated 15 July 2008 (Ref: SU0013:66281). | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | M4Q05 | Biosciences North, Plant, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | M4Q07 | Biosciences North, Mech Riser F, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | M4Q09 | Biosciences North, Mech Riser F, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | M4Q14 | Biosciences North, Mech Riser D, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | M4Q15 | Biosciences North, Mech Riser D, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 501A-501E | Biosciences North, Offices, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 133 | Beneath Fume Cupboards (stored in plastic tubs) | Heat Resistant Mats | Fibre Cement Sheeting | Removed - Positive (chrysotile & amosite) | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG21 | - | Floor Covering | Vinyl Floor Tiles (beige colour) | Assumed Positive - Removed | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 4 September 2008 (Ref: 68276). | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG23 | - | Floor Covering | Vinyl Floor Tiles (beige colour) | Assumed Positive - Removed | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 4 September 2008 (Ref: 68276). | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1326 | Service Duct Entry off Room 1326 | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate dated 16 March 2015 (Ref: J131981.002). Removed by Pure Contracting. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 502 | Biosciences North, Comms | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 519 | Biosciences North, Comms | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 520A-520E | Biosciences North, Comms | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q7 | Electrical Riser Cupboard | Beneath & Behind Electrical Cabinet | Packing Insulation | Suspected Positive | Friable | Low | P3 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q11 | Biolink, | Beneath & Behind Electrical Cabinet | Packing Insulation | Suspected Positive | Friable | Low | P3 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
FSFG | Fowlers Gap Field Station | FG19 | Fowlers Gap Cottage 3 | G | - | Exterior, Surrounding Cottage | On Ground Surface | Fibre Cement Sheet Debris | Assumed Positive - Removed | - | - | - | Item removed: UNSW site personnel informed RiskTech that fibre cement debris removed. No fibre cement debris sighted by RiskTech during the inspection. | Yes |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | - | Exterior, Surrounding Building | On Ground Surface | Fibre Cement Sheet Debris | Assumed Positive - Removed | - | - | - | Item removed. UNSW site personnel informed RiskTech that fibre cement debris removed. RiskTech also removed fibre cement debris as part of the inspection process. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG1 | - | Floor Covering | Vinyl Floor Tiles (beige colour) | Assumed Positive - Removed | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 4 September 2008 (Ref: 68276). | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG8A | - | Floor Covering | Vinyl Floor Tiles (beige colour) | Assumed Positive - Removed | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 4 September 2008 (Ref: 68276). | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG16 | - | Floor Covering | Vinyl Floor Tiles (beige colour) | Assumed Positive - Removed | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 4 September 2008 (Ref: 68276). | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG17 | - | Floor Covering | Vinyl Floor Tiles (beige colour) | Assumed Positive - Removed | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 4 September 2008 (Ref: 68276). | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG19 | - | Floor Covering | Vinyl Floor Tiles (beige colour) | Assumed Positive - Removed | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 4 September 2008 (Ref: 68276). | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | - | Exterior, South Entrance to LGQ2A | Door Beading (between frame & glass pane) | Sealant Mastic | Assumed Positive - Removed | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate dated 28 September 2015 (Ref: C107859:J140807.001). | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 140 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 145A | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 177 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 179 | Sprinkler Pump Room | Fire Door (tagged 'Masterbilt, 1974') | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q9 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q4 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q8 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q10 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q12 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q8 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 522 | Former Rooms 522 & 523 - now Room 520 | Fire Doors | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 523 | Former Rooms 522 & 523 - now Room 520 | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 523 | Service Duct Entry | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q6 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q8 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q8 | NW Fire Stairs & Duct | Roof | Bituminous Membrane | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate date 17 September 2017. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 9Q2 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to Bismac Fire Door Replacement Certificate dated 23 February 2011. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 9Q3 | - | Fire Door | Core Insulation | Removed - Assumed Positive | - | - | - | Item Removed: Refer to Bismac Fire Door Replacement Certificate dated 23 February 2011. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q10 | Biosciences North, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | 117 | - | Floor Covering | Vinyl Floor Tiles (brown colour) | Removed -Assumed Positive | - | - | - | Item Removed: Refer to NAA Clearance Certificate (Ref: 77747) dated 10 September 2011. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | 118 | - | Floor Covering | Vinyl Floor Tiles (brown colour) | Removed -Assumed Positive | - | - | - | Item Removed: Refer to NAA Clearance Certificate (Ref: 77747) dated 10 September 2011. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | 118A | - | Floor Covering | Vinyl Floor Tiles (brown colour) | Removed -Assumed Positive | - | - | - | Item Removed: Refer to NAA Clearance Certificate (Ref: 77747) dated 12 September 2011. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | 119A | - | Floor Covering | Vinyl Floor Tiles (brown colour) | Removed -Assumed Positive | - | - | - | Item Removed: Refer to NAA Clearance Certificate (Ref: 77747) dated 12 September 2011. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | 129 | - | Soffit Surrounding Columns | Insulation (vermiculite) | Removed -Assumed Positive | - | - | - | Item Removed: Refer to NAA Clearance Certificate (Ref: 57646) dated 25 June 2007. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | 130 | - | Soffit Surrounding Columns | Insulation (vermiculite) | Removed -Assumed Positive | - | - | - | Item Removed: Refer to NAA Clearance Certificate (Ref: 57646) dated 25 June 2007. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | 1Q6 | - | Floor Covering | Vinyl Floor Tiles (brown & cream colour) | Removed -Assumed Positive | - | - | - | Item Removed: Refer to NAA Clearance Certificate (Ref: 77747) dated 12 September 2011. | Yes |
KENC | Kensington Campus | F21 | Library | 10 | - | Various Rooms | Air Conditioning Ductwork | Insulation Board | Removed -Assumed Positive | - | - | - | Item Removed: Refer to Airsafe Clearance Certificate (Ref: 27785). Removed by Executive Demolition Group Pty Ltd on 9 July 2015. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 615 | East | Air Conditioning Ductwork Heater Unit | Millboard Insulation Board | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 930 | Service Duct Entry | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate dated 16 March 2015 (Ref: J131981.002). Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1026 | Service Duct Entry | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate dated 16 March 2015 (Ref: J131981.002). Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1027 | - | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate dated 16 March 2015 (Ref: J131981.002). Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1120 | - | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to Asbestos Containing Material (ACM) Work Permit dated 26 September 2015. Removed by Australasian Technical Services. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1126 | - | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate dated 16 March 2015 (Ref: J131981.002). Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1127 | - | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate dated 16 March 2015 (Ref: J131981.002). Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1227 | Service Duct Entry | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate dated 16 March 2015 (Ref: J131981.002). Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1228 | - | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 12Q2 | - | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 12Q3 | - | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1327 | - | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate dated 16 March 2015 (Ref: J131981.002). Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 1428 | - | Fire Door | Core Insulation | Assumed Positive - Removed | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate dated 16 March 2015 (Ref: J131981.002). Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1533 | Service Duct Entry | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: NAA Clearance Certificate dated 5 November 2008 (Ref: SU0013:69558). | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1533 | Service Duct Entry | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: NAA Clearance Certificate dated 5 November 2008 (Ref: SU0013:69558). | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1534 | - | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: NAA Clearance Certificate dated 5 November 2008 (Ref: SU0013:69558). | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 15Q2 | - | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: NAA Clearance Certificate dated 5 November 2008 (Ref: SU0013:69558). | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 15Q3 | - | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: NAA Clearance Certificate dated 5 November 2008 (Ref: SU0013:69558). | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 15 | - | Throughout | Air Conditioning Ductwork Heater Units | Insulation Board | Removed -Assumed Positive | - | - | - | Item Removed: NAA Clearance Certificate dated 5 November 2008 (Ref: SU0013:69558). | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1629 | - | Fire Door | Core Insulation | Assumed Positive - Removed | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate dated 16 March 2015 (Ref: J131981.002). Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 17 | 1701 | - | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 17 | 1701 | East Side | Inside Electrical Cabinet (new appearance cabinet) | Electrical Backing Board | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. Electrical cabinet removed between 29 January 2019 and 26 July 2019. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 17 | 1702 | - | Fire Door (previously tagged 'Masterbilt') | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 17 | 1703 | - | Fire Doors | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. (New appearance fire doors - no tag). | Yes |
KENC | Kensington Campus | F13 | Science Theatre | G | G08 & G08A | Entry Way, Western Wall Behind Plasterboard Wall (wall is common with electrical cupboard in Room G07) | Wall Lining | Fibre Cement Sheeting | Assumed Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q03 | Fire Hose Cupboard | Floor Covering | Adhesive (attached to vinyl tiles) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG8 & LG8A | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 515 | Throughout | Floor Covering | Adhesive attached to Grey Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F12 | Dalton | G | 1Q4 | - | Ceiling | Sprayed Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | G | G24 | - | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
FSSL | Smiths Lake Field Station | SL5 | Smiths Lake Cooking Shelter | G | G01 | North Side | Wall Panelling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | O14 | Kangas House | G | - | Exterior, Eastern Building, West Side, Above Awning (Outside Room 50 & 51) | Infill Wall Panelling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | 102 | Garbage Bin Room | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 6 | 6Q03 | Ceiling | Ductwork Joints | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 1 | 113 | Duct Riser (southeast corner) | Wall Partition Panelling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K14 | Physics Theatre | LG | - | Exterior, North Side, Adjacent Entrance to Room LG15 | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q20 | Biosciences North, Gas Manifold, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q50 | Biosciences North, East Riser 1, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | J14 | Keith Burrows Theatre | G | G06 | Female Toilet, Ceiling Space | Ductwork Joins | Mastic Sealant (red colour) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | J14 | Keith Burrows Theatre | G | G01 | North | Windows (between frame and pane) | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | J12 | Newton | G | G01 | Mezzanine Area, North Adjacent Access Ladder | Duct Work Heater Bank | Millboard Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | J12 | Newton | 2 | 2Q7 | Hallway | Floor Covering | Cream Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | J12 | Newton | 2 | 2Q2 | Opposite Lifts | Windows | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | J12 | Newton | 2 | 227 | Riser | Loose Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | ROQ3 | Fire Stairwell, Roof Access Door | Fire Door (no tag) | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | G | GQ2 | Electrical Cupboard | HV Electrical Cable | Bituminous Wrap Material | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | RQ06 | Eastern Roof Area | Water Pumps, Pipe Work | Gasket (Green Colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 9 | RQ01 | Surrounding Wall Parapet | Expansion Joints | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 9 | RQ01 | Throughout, Between Concrete Pavers | Expansion Joints | Bituminous Material | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | R1 | Plant Room | Water Tanks | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H13 | The Red Centre | G | - | Exterior, Western Façade | Wall Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | 4 | 407 | Cooling Tower Room | Fire Door (tagged 'Masterbilt') | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | 4 | 406 | Boiler Room | Fire Door (tagged 'Masterbilt') | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | 4 | 405 | Duct Work Above Chiller | Air Conditioning Ductwork Heater Bank | Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | LG | LG09A | Ceiling Space Above Electrical Switch Board | Air Conditioning Ductwork Heater Bank | Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | 1 | 110 | Throughout | Ceiling | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | G | - | Exterior, Northeast Corner | Expansion Joint between Brickwork Sections | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G19 | John Niland Scientia | LG | - | Eastern Side, Foundation Space | Pipe | Moulded Fibre Cement Material | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G19 | John Niland Scientia | 1 | 102 | Servery | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q51 | Biosciences North, West Riser A, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | E5Q01 | Biosciences North, Elec, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | E5Q02 | Biosciences North, Elec, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
FSW | Wellington Field Station | WFS1 | Wellington Field Station Cottage | G | 1 | Main Residence, Roof Space | On Top of Ceiling | Loose Insulation | Negative | - | - | - | - | N/A |
FSW | Wellington Field Station | WFS1 | Wellington Field Station Cottage | G | 1 | Main Residence, Bathroom | Ceiling Manhole Cover | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | F8 | Law Building | G | UGQ01 | Exterior | Awning | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 615 | - | Air Conditioning Ductwork Heater Units | Millboard Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q17 | Fire Stairs | Ductwork | Insulation (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F22 | Bank | - | - | Exterior, Eastern Side, Mid Section | Window Frames (between frame and pane) | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F22 | Bank | - | - | Exterior, Western Side, Northern End | Window Frames (between frame and pane) | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 4 | 480 | Near Perimter East Risers | Inside Air Conditioning Ductwork | Dust | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | 1Q5 | - | Fire Doors (no tag) | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | LG | LGQ01 | Boiler Room | Chilled Water Pipework | Bituminous Coating (adhesive) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | 101 | Corridor | Fire Doors (no tag) | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 15 | 1504 | Cooling Tower Room, West & South Sides | Vertical Wall Stiffeners (behind metal cover) | Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 15 | 1504 | Cooling Tower Room | On Top of Blockwork Walls | Insulation Packing | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | LG | LG29 | East Side | Vertical Expansion Wall Joint (behind metal sleeve) | Compressed Soft Fibreboard (brown colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | 02 | 238A | Female Shower Area | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | LG | LG28 | - | Ceiling (soffit) | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | LG | LG28 | East Side, South Wall | Vertical Expansion Wall Joint | Sealant Mastic (white colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | LG | LG29 | - | Ceiling (soffit) | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | LG | - | Exterior, East Side, Outside Room LGQ7 | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | LG | LG29 | - | Floor Covering | Bituminous Adhesive Beneath Vinyl Floor Tiles (black colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | LG | LG28 | - | Floor Covering | Bituminous Adhesive Beneath Vinyl Floor Tiles (black colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | LG | LG30 | Northern Section | Floor Covering | Vinyl Floor Tiles (beige colour) & Bituminous Adhesive (black colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F17 | Rex Vowels Theatre | 1 | LGQ5 | Plant Room, Level 1 | Wall Divider to Cooling Tower Area | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F17 | Rex Vowels Theatre | LG | LGQ5 | Plant Room, Central | Compressor Manifold | Gasket | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F17 | Rex Vowels Theatre | G | - | Exterior, Surrounding | Wall Expansion Joints | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F13 | Science Theatre | 1 | 107A | Throughout | Cubicle Partitions | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F13 | Science Theatre | G | G08/G08A | - | Floor Covering | Sheet Vinyl (blue speckled) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 318 | South Side | Windows (between frame and pane) | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | - | Exterior, Façade (access via room 318) | Windows (between frame and pane) | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | C01Q01 | Service Riser | Hot Water Pipe Work | Gasket (brown colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 204 | Cleaners Room | Shelving | Vinyl Tiles (blue) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | M | - | Exterior, North Adjacent Entrance to Room M17 (undercroft area) | Vertical Wall Joint | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | LR | R1Q01 | Exterior, Adjacent Room R1, Ground Surface | Expansion Joints (between concrete pavers) | Bituminous Membrane | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | LR | R2 | Ceiling, Lift Motor Room Hatch | Hatch Door | Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E4 | Squarehouse | 01 | 106 | North | Ductwork Heater Banks | Insulation Board | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | F5Q01 | Biosciences North, FHR, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | F5Q03 | Biosciences North, Fire Riser, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 02 | 205A | Entrance | Fire Door (no tag) | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D14 | UNSW Hall | G | A90 | Exterior, East | Infill Panel Below Window | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | C294 | Windows | Infill Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C25 | Lowy Cancer Research Centre | R | RQ3 | Air Handling Plant Room | Vertical Structural Framwork | Sprayed Insulation (Vermiculite) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | L5LS | Biosciences North, Goods Lift, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | M5Q05 | Biosciences North, Plant, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | M5Q07 | Biosciences North, Mech Riser F, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | M5Q09 | Biosciences North, Mech Riser F, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | G03 | Gymnasium (B5), Gym Area, South Side | Ductwork Heater Bank | Millboard Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B15 | Old Tote | 01 | - | Exterior, Surrounding | Windows | Mastic sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B14D | Fig Tree Theatre | G | 3 | Make Up/Preparation Rooms | Floor Covering under Carpet Tiles | Vinyl Tiles (cream colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B14D | Fig Tree Theatre | G | 3 | Make Up/Preparation Rooms | Floor Covering under Carpet Tiles | Vinyl Tiles (brown colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B14D | Fig Tree Theatre | G | - | Exterior, Surrounding | Windows | Mastic Sealant | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | M5Q14 | Biosciences North, Mech Riser D, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | M5Q15 | Biosciences North, Mech Riser D, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | 603 | Biosciences North, Comms Structural Walls Surrounding 6Q20 Gas Manifold | Conduits | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | 130A | Plant Room, Inside AHU No.6, Pre-Filter Area | On Floor Surfaces | Dust & Debris | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | 130A | Plant Room, Inside AHU No.4, Pre-Filter Area | Filter Bag Media | Dust & Debris | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | 130A | Plant Room, Inside AHU No.5, Pre-Filter Area | On Floor Surfaces | Dust & Debris | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | 130A | Plant Room, Inside AHU No.4, Pre-Filter Area | On Floor Surfaces | Dust & Debris | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | 130A | Plant Room, Inside AHU No.6, Pre-Filter Area | Filter Bag Media | Dust & Debris | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | LG | LGQ06 | Air Conditioning Plant Room Inside AHU No.3, Pre-Filter Area | On Floor Surfaces | Dust & Debris | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | LG | LGQ06 | Air Conditioning Plant Room Inside AHU No.3, Pre-Filter Area | Filter Bag Media | Dust & Debris | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | LG | LGQ05 | Air Conditioning Plant Room Inside AHU No.2, Pre-Filter Area | On Floor Surfaces | Dust & Debris | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | LG | LGQ05 | Air Conditioning Plant Room Inside AHU No.2, Pre-Filter Area | Filter Bag Media | Dust & Debris | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | LG | LGQ03 | Air Conditioning Plant Room Inside AHU No.1, Pre-Filter Area | On Floor Surfaces | Dust & Debris | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | LG | LGQ03 | Air Conditioning Plant Room Inside AHU No.1, Pre-Filter Area | Filter Bag Media | Dust & Debris | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | 622 | Biosciences North, Comms | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 05 | 5Q1 | Exterior, South | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 05 | 5Q1 | Throughout | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | 6Q04 | Biosciences North, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | 6Q19 | Biosciences North, Ante Room, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | M15 | Rupert Myers | 02 | 2013A | Throughout | Floor Covering | Sheet Vinyl (blue colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | G | G06 | Throughout | Cubicle Partitions | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | G | G14 | Switch Room | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 05 | 5Q3 | Stairwell | Fire Door (tagged 'Wormald, 2011') | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 01 | 1Q6 | Fire Pump Room, Top of Wall | Expansion Joint | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E4 | Squarehouse | R | RQ1 | - | Ductwork Flange Joints | Mastic Sealant (grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E15 | Quadrangle | R | R1Q09 | Ductwork | Sprayed Insulation | Insulation (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E15 | Quadrangle | G | GQ34B | Riser Duct | Waste Pipe | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | 6Q50 | Biosciences North, East Riser 1, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E12 | UNSW Business School | 6 | 6Q9 | Female Toilet | Wall Linings | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
DPFS | David Phillips Field | DP4 | Grounds Depot | G | G02 | Toilet | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D9 | IO Myers Studio | G | - | Exterior, South East Side of G04 | Infill Wall Panel | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | 6Q51 | Biosciences North, West Riser A, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | E6Q01 | Biosciences North, Elec, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | E6Q02 | Biosciences North, Elec, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D17 | Basser College | 5 | 5Q01 | Fire Stairs, Surrounding | Wall Expansion Joint | Mastic Sealant | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D16 | Goldstein Hall | 01 | 1Q10 | - | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D16 | Goldstein Hall | 02 | M2Q01 | Exterior, Roof Plant Area, Surrounding | Fascia Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D16 | Goldstein Hall | 02 | M2Q01 | Exterior, Roof Plant Area, North and South | Window Frames | Mastic Sealant | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D16 | Goldstein Hall | G | GQ8 | - | Wall Linings | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D10 | Building D10 | G | GQ1 | Exterior, at Entrance | Wall Infill Panel | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D10 | Building D10 | G | G07 | West | Wall Infill Panel | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAG | Block G | G | EGGQ1 | Electrical Cupboard | Cover Beneath Electrical Cabinet | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | B | FBQ9 | Plant Room | Ductwork Flange Joints, Dust Extraction Unit | Mastic Sealant (grey colour) | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | 02 | - | Exterior, North-East Terrace | Ceiling Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAE | Block E | B | EB10 | Former Fire Escape Cupboard | Decorative Coating to Vertical Column | Textured Paint | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAE | Block E | B | EB10 | Former Fire Escape Cupboard | Decorative Coating to Vertical Column | Textured Paint | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAE | Block E | 01 | UE1Q01 | Exterior | Ceiling Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAD | Block D | 03 | D3Q2 | Boiler Room, North-East | Boxing | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAC | Block C | G | - | Exterior, Throughout | Window Frames | Mastic Sealant | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAA | Block A | 01 | A101 | Exterior | Window Frames (Between Frame and Pane) | Mastic Sealant | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G99 | Exterior, Northern Side - Garbage Collection Garage | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 209 | Accommodation Room | Fire Door Frame behind metal frame) | Cementitous Material | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | - | Western Section, Roof Space | On Concrete Slab | Bituminous membrane | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | GQ6 | Exterior | Wall Linings | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | - | Exterior, SE Pyramid, South of Room GQ6 | Floor Covering (beneath floor pavers) | Bituminous Membrane | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | G7 | Behind Ceramic Walls Tiles | Wall Linings | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | G4A | Behind Ceramic Walls Tiles | Wall Linings | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q2 | Window Sill | Floor and Ceiling of Window Sill | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 257 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG56 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG54 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 351 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 202 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | G | G36 | Under Carpet | Floor Covering | Vinyl Floor Tiles (white colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | G | G58 | Under Carpet | Floor Covering | Vinyl Floor Tiles (cream colour) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C15 | White House | G | - | Exterior, North Side | Window Frames (Between Frame and Pane) | Mastic Sealant | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C15 | White House | 01 | 103 | Cleaner's Store | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | - | Pool (B4), Exterior, South, Seated Area | Expansion Wall Joint | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | P06 | Pool (B4), South & West | Wall Linings | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | F6Q01 | Biosciences North, FHR, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E6 | Roundhouse | 01 | - | Exterior, Surrounding | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | F6Q03 | Biosciences North, Fire Riser, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | L6LS | Biosciences North, Goods Lift, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | M6Q02 | Biosciences North, Plant, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | M6Q05 | Biosciences North, Plant, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | M6Q07 | Biosciences North, Mech Riser F, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | LG | LG56 | Layer Between Concrete Floor Slabs | Insulation | Bituminous Material | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q14 | North | Window Frames (between frame and pane) | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | G | GQ18 | North | Window Frames (between frame and pane) | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q17 | West Side of Hallway | Window Frames (between frame and pane) | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | LG | LGQ3 | Stairwell, North | Window Frames (between frame and pane) | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | G | G49 | - | Floor Covering | Vinyl Tiles cream colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 02 | 2Q8 | Fire Hydrant Cupboard | Floor Covering | Vinyl Tiles (flexible red and blue colour) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | - | Exterior, Eastern Side, SE Corner Amenities Block | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | - | Exterior, Eastern Side, SE Corner Entrance | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | - | Exterior, Northern Roof Section, Above Section of Courtyard | Roof | Bituminous Membrane | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | M6Q09 | Biosciences North, Riser F, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | M6Q11 | Biosciences North, Mech Riser F, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | M6Q16 | Biosciences North, Mech Riser D, | Conduit | Moulded Fibre Cement Material | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ12 | Electrical Cupboard | Panel Above Door | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q10 | Electrical Cupboard | Panel Above Door | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q4 | Electrical Cupboard | Panel Above Door | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q10 | Electrical Cupboard | Panel Above Door | Core Insulation | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV3 | Laboratory 2 | G | - | Exterior, South Side | Top of Blockwork Piers Pipe Support Structures | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G01 | Below Former Room G02, East Side, SE Corner | Wall Panel | Fibre Cement Sheeting | Positive (chrysotile) (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | N/A |
MANV | Manly Vale | MV3 | Laboratory 2 | B | - | Sub-Floor Space, Beneath Eastern Office/Amenities | Ground Surface, Debris | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV3 | Laboratory 2 | B | - | Sub-Floor Space, Beneath Eastern Office/Amenities | Flooring | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | - | Riser Adjacent Room 326 | Timber Panel | Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | GQ10 | Corridor Entry | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G99A | Toilet | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G97 | Office | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G96 | Office | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G94 | Office | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G9 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G80 | Recreational Room | Doors | Insulation Core (timber) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G8 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G7 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G6 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G5 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G4 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G3 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G29 | Female Amenities / Toilets | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G28 | Male Amenities / Toilets | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G27 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G26 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G25 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G24 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G23 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G22 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G21 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G20 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G2 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G17 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G16 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G15 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G14 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G13 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G12 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G11 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G10 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G1 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 399 | Male Amenities / Toilets | Door | Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 398 | Store | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 396 | Female Amenities / Toilets | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 393 | Kitchen - Riser | Fire Panel | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 392 | Store | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 391 | Store | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 390 | Store | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 341 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 340 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 336 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 335 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 334 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 333 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 332 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 331 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 330 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 329 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 328 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 327 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 326 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 325 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 324 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 323 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 322 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 321 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 318 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 317 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 316 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 315 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 314 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 313 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 312 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 311 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 310 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 309 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 308 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 307 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 306 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 302 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 301 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 299 | Male Amenities / Toilets | Door | Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 298 | Store | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 296 | Female Amenities / Toilets | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 293 | Kitchen - Riser | Fire Panel | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 292 | Store | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 291 | Store | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 290 | Store | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 241 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 240 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 236 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 235 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 234 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 233 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 232 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 231 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 230 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 229 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 228 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 227 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 226 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 225 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 224 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 223 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 222 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 221 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 218 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 217 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 216 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 215 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 214 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 213 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 212 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 211 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 210 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 209 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 208 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 207 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 206 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 202 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 2 | 201 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 1Q9 | CorridorAdjacent Room 107 | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 1Q1 | CorridorAdjacent Room 135 | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 199 | Male Amenities / Toilets | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 198 | Store | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 196 | Female Amenities / Toilets | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 193 | Kitchen - Riser | Fire Panel | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 192 | Store | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 191 | Store | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 190 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 187A | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 181 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 179 | Female Amenities / Toilets | Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 156 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 155 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 154 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 153 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 150 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 149 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 148 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 147 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 146 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 145 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 144 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 143 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 142 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 141 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 140 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 136 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 135 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 134 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 133 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 132 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 131 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 130 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 129 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 128 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 127 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 126 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 125 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 124 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 123 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 122 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 121 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 118 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 117 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 116 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 115 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 114 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 113 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 112 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 111 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 110 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 109 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 108 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 107 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 106 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 102 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 1 | 101 | Accommodation Room | Fire Door | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G88 | Dining Room, Western Side (North End) | Wall Lining | Plasterboard | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 5 | - | SE Corner Riser Adjacent Fire Stairs (5Q5) | On Top of Blockwork Walls | Insulation (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 4 | - | Old Northern Building Section, Roof Space | On Top of Concrete Slab | Loose Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 11 | - | Roof Area, Above SE Fire Stairs | Roof | Flexible Membranous Layer & Attached Bituminous Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F13 | Science Theatre | G | G15 | Stage Left | Flue | Woven Cloth Covering (beneath metal sheet covering) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F13 | Science Theatre | G-2 | - | Westerm External Façade | Wall Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 133 | Eastern End, Beneath Fume Cupboards (stored in plastic tubs) | Floor Surface Adjacent & Beneath Stored Heat Resistant Mats | Dust | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F11 | Chemical Sciences | 1 | 133 | Eastern End, Beneath Fume Cupboards | Floor Surface Adjacent & Beneath Stored Heat Resistant Mats | Dust | Negative | - | - | - | - | N/A |
MISC | Miscellaneous | BC34 | Woolley House | - | - | Exterior | Roof, Beneath Roof Tiles | Sarking (sisilation sheeting) | Negative | - | - | - | - | N/A |
MISC | Miscellaneous | BC34 | Woolley House | 01 | G04 | Laundry | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
MISC | Miscellaneous | BC34 | Woolley House | 01 | G04 | Laundry | Floor Covering | Cork Tiles | Negative | - | - | - | - | N/A |
MISC | Miscellaneous | BC34 | Woolley House | 01 | G04 | Laundry | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
MISC | Miscellaneous | BC34 | Woolley House | 02 | GQ02 | Ensuite | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
MISC | Miscellaneous | BC34 | Woolley House | 03 | GQ04 | Bathroom | Walls & Ceiling | Cementitious Material | Negative | - | - | - | - | N/A |
MISC | Miscellaneous | BC34 | Woolley House | 04 | G09A | Store | Wall Section | Membrane | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | R01 | Plant Room | Air Handling Units - Panel Joints & Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | ELGQ02 | Biolink, Former Electrical Riser Cupboard off Room LGQ11 | Inside Electrical Distribution Board Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | GQ13 | Bilolink, | Inside Electrical Distribution Board Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R1 | Randwick R1 | LG | - | Tunnel or Former Open Pit | Floor Covering | Bituminous Covering | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q12 | Biolink, Electrical Riser Cupboard | Inside Electrical Distribution Board Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 7 | 705 | Roof Area, Central | Benches | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 7 | 705 | Roof Entrance | Wall Joint Between Door and Wall | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 7 | 705 | Western Roof Raised Area | Gap Above Membrane on Posts | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 7 | 705 | Western Roof Raised Area | Floor / Roof Expansion Joint | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 7 | 705 | Roof Area, Throughout | Floor Covering | Bituminous Membrane (black colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 7 | 705 | Roof Area, Throughout | Floor Covering | Bituminous Membrane (grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 14 | 14Q1 | Fire Stairs | Soffit | Cementitious Material | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 14 | 1401 | Ceiling Space, Northern Section | Pipework | Insulation (brown coloured woven wrap) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 5 | - | Goods Lift Shaft | Face of Landing Doors & Landing Door Sill | Dust & Debris | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | - | - | Goods Lift Shaft | Top Surface of Counterweight | Dust | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 9 | - | Goods Lift Shaft | Top Surface of Counterweight Bracket | Dust & Debris | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 10 | - | Goods Lift Shaft | Landing Door Sill | Dust & Debris | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 13 | - | Goods Lift Shaft | Face of Landing Doors | Dust | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | Unit 14 | Unit 14, Kitchen | Floor Covering | Vinyl Floor Tiles (lower layer – grey colour) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | Unit 14 | Unit 14, Kitchen | Floor Covering | Vinyl Floor Tiles (lower layer – grey colour) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | Unit 13 | Unit 13, Kitchen | Floor Covering | Vinyl Floor Tiles (lower layer – grey colour) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | Unit 10 | Unit 10, Kitchen, West | Floor Covering | Vinyl Floor Tiles (lower layer – beige/off-white colour) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | Unit 10 | Unit 10, Kitchen, East | Floor Covering | Vinyl Floor Tiles (lower layer – beige/off-white colour) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | Unit 10 | Unit 10, Kitchen, East | Floor Covering | Vinyl Floor Tiles (lower layer – beige/off-white colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 15 | 1502 | Boiler Room | Hot Water Pipework, Flange Joints | Gasket | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 15 | 1502 | Boiler Room | Boiler Flues (behind metal sheet) | Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | 3 | 3Q2 | Fire Stairwell | Fire Door (tagged 'TDF, 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 2 | 2Q2 | Fire Stairwell | Fire Door (tagged 'Masterbilt') | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | 4 | 409 | Plant Room, Surrounding | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1621 | South | Between Lower Metal Window Framework & Glass | Sealant Mastic (black rubber seal) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1621 | South | Between Lower Metal Window Framework & Glass | Sealant Mastic (black colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1614 | East | Between Upper Metal Window Framework & Glass | Sealant Mastic (black rubber seal) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1614 | East | Between Lower Metal Window Framework & Glass | Sealant Mastic (black colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 1 | - | Exterior, Façade, East, Far SE Corner | Between Metal Window Framework & Glass | Black Rubber Seal | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 5 | - | Exterior, Façade, South, 3rd Bay from East End | Thin Covering Over Concrete Vertical Joint Between Metal Window Framework & Column | Sealant Mastic (light grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 5 | - | Exterior, Façade, South | Vertical Joint (joint closest to column) Between Metal Window Framework & Column | Sealant Mastic (grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 11 | - | Roof Area, Façade, East & South | Joint Between Metal Window Framework & Concrete Façade Panel | Sealant Mastic (grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 5 | - | Exterior, Façade, South | Between Lower Metal Window Framework Joints | Sealant Mastic (light grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 11 | - | Roof Area, Façade, East & South | Vertical Joint Concrete Façade Panel & Column | Sealant Mastic (grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | - | Exterior, Façade, South Tower Section, East | Horizontal Joint Between Base of Metal Window Framework & Concete Façade Panel | Sealant Mastic (grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | - | Exterior, Façade, Tower Section, West Adjacent to Substation 11 | Vertical Joint Between Concete Façade Panel & Column | Sealant Mastic (grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 5 | - | Exterior, Façade, South | Horizontal Joint Between Base of Metal Window Framework & Concrete Façade Panel | Sealant Mastic (dark grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | - | Exterior, Façade, Old Low Rise Northern Brick Section, South Side (Eastern Section) | Between Metal Window Framework & Glass | Caulking Mastic (brown colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 5 | - | Exterior, Façade, South | Between Upper Metal Window Framework & Glass | Sealant Mastic (black rubber seal) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | - | Exterior, Façade, Tower Section, East (Adjaoining Bank Building) | Between Metal Windows Framework & Glass | Caulking Sealant (brown colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 5 | - | Exterior, Façade, South | Horizontal Joint Between Top of Metal Window Framework & Concrete Façade Panel | Sealant Mastic (dark grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 5 | - | Exterior, Façade, South | Vertical Joint (joint closest to window) Between Metal Window Framework & Column | Sealant Mastic (dark grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 1 | - | Exterior, Façade, South, Far SE Corner | Vertical Joint Between Metal Window Framework & Façade | Sealant Mastic (dark grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | - | Exterior, Façade, South Tower Section, South | Vertical Joint Between Concrete Façade Panel & Column | Sealant Mastic (grey colour - new appearance) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q6 | Biolink, Electrical Riser Cupboard | Inside Electrical Distribution Board Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 4 | 4Q6 | Biolink, Electrical Riser Cupboard | Inside Electrical Distribution Board Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C27 | Wallace Wurth | LG | LG42 | On Top of Cool Room | Debris | Vermiculite Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C27 | Wallace Wurth | LG | LG42 | On Top of Cool Room | Debris | Vermiculite Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C27 | Wallace Wurth | LG | LG43 | Chilled water pipe insulation | water pipe | Black bituminous coating | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C27 | Wallace Wurth | LG | LG42 | Above cool rooms - upper walls | Upper wall | Black bituminous coating on cement | Removed | - | - | - | Removed - refer RiskTech Clearance cert dated 21/09/2021 | Yes |
KENC | Kensington Campus | C27 | Wallace Wurth | LG | LG42 | Above Cool Room, Brick Wall & Soffit, Beneath White-Coloured Paint Encapsulant | Wall/Soffit Covering | Adhesive (black colour) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q7 | Electrical Riser Cupboard | Inside Electrical Distribution Board Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 5 | 5Q11 | Biolink, | Inside Electrical Distribution Board Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 350 | Biolink | Fume Cupboard, Internal Lining | Fibre Cement Sheeting | Removed -Suspected Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 November 2021. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | G | G20 | Biolink, South, Access to Room G21 | Fire Door (tagged 'Masterbilt, 1969') | Insulation Core | Removed - Suspected Positive | - | - | - | Item Removed: Refer to Greencap NAA Asbestos Clearance Certificate (Ref: C107266:J134916.003) dated 28 September 2015. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG01 | Biosciences North, Electrical Cupboard | Inside Electrical Cabinets | Electrical Backing Boards | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. Note: New switchboard electrical cabinets. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LGQ4A | Biosciences North, Electrical Cupboard | Inside Electrical Cabinets | Electrical Backing Boards | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. Note: New switchboard electrical cabinets. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LGQ7A | Biosceinces North, | Inside Electrical Cabinets | Electrical Backing Boards | Suspected Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New switchboard electrical cabinets). | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q5 | Biolink, | Inside Electrical Cabinets | Electrical Backing Boards | Suspected Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New switchboard electrical cabinets). | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 2Q2 | Biosciences North, | Inside Electrical Distribution Board Cabinet | Electrical Backing Board | Suspected Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New switchboard electrical cabinets). | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 2Q4 | Biosciences North, | Inside Electrical Distribution Board Cabinet | Electrical Backing Board | Suspected Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New switchboard electrical cabinets). | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 2 | 2Q7 | Biolink, Electrical Riser Cupboard | Inside Electrical Distribution Board Cabinet | Electrical Backing Board | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. Note: New switchboard electrical cabinets. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q2 | Biosciences North, | Inside Electrical Distribution Board Cabinet | Electrical Backing Board | Suspected Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New switchboard electrical cabinets). | Yes |
KENC | Kensington Campus | K17 | Building K17 | G | G14 | South Side | Windows | Mastic Sealant (vertical joints between metal framework) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 5 | 510 | South Side | Windows | Mastic Sealant (vertical joints between metal framework) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | G | - | Exterior, Façade, North Side, Northeast Corner | Window | Mastic Sealant (between metal framework & glass pane) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | G | - | Exterior, Façade, North Side, Northeast Corner | Window | Mastic Sealant (between metal framework & concrete column) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | G | - | Exterior, Façade, East Side, Southeast Corner | Window | Mastic Sealant (between metal framework & concrete column) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | G | - | Exterior, Façade, East Side, Southeast Corner | Window | Mastic Sealant (between metal framework & glass pane) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | G | - | Exterior, Façade, South Side, Southeast Corner | Window | Mastic Sealant (between metal framework & glass pane) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | G | - | Exterior, Façade, South Side, Southeast Corner & East Side | Window | Mastic Sealant (between metal framework & concrete column) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | B | - | Exterior, Façade, South Side, Southwest Corner | Window | Mastic Sealant (between metal famework & glass pane) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | B | - | Exterior, Façade, South Side, Southwest Corner | Window | Mastic Sealant (between metal framework & concrete column) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 2 | - | Exterior, Façade, South Side, West End | Window | Mastic Sealant (between metal framework & glass pane) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 5 | - | Exterior, Façade, South Side, West End | Window | Mastic Sealant (between metal framework & glass pane) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 1 | - | Exterior, Façade, South Side, Southeast Corner | Window | Mastic Sealant (between metal framework & concrete column) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 2 | - | Exterior, Façade, South Side, East Bay | Window | Mastic Sealant (between metal framework & glass pane) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 3 | - | Exterior, Façade, South Side, Southeast Corner | Window | Mastic Sealant (between metal framework & concrete column) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 4 | - | Exterior, Façade, South Side, East Bay | Window | Mastic Sealant (between metal framework & glass pane) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 5 | - | Exterior, Façade, South Side, Southeast Corner | Window | Mastic Sealant (between metal framework & concrete column) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 6 | - | Exterior, Façade, South Side, East Bay | Window | Mastic Sealant (between metal framework & glass pane) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 6 | - | Exterior, Façade, South Side, Southeast Corner & West End | Window | Mastic Sealant (between metal framework & concrete column) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 3 | 3Q4 | Biosciences North, | Inside Electrical Distribution Board Cabinet | Electrical Backing Board | Suspected Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New switchboard electrical cabinets). | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | 603 | - | Air Conditioning Duct Heater Bank | Insulation Board | Removed -Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | 621 | - | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
FSFG | Fowlers Gap Field Station | FG4 | Fowlers Gap Cottage 5 | G | G05/ G05A | Bathroom | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | G08 | Kitchen, West Side (behind sink & adjoining cupboards) | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | 643 | Plant Room | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | C6 | International House | G | G3 | Accommodation Room | Inside Wardrobe - Top Shelf | Dust Sample | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | 6Q3 | Electrical Riser Cupboard | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | G27 | AGSM | 1 | 114A | Electrical Cupboard | Electrical Link Box | Electrical Backing Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | 2 | 210 | Electrical Cupboard | Electrical Link Box | Electrical Backing Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | 3 | 3Q5 | Electrical Cupboard | Electrical Link Box | Electrical Backing Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 16 | 1604 | Lift Motor Room | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G76 | Store | Fire Door (no tag - door installed in Dec 2018) | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G78 | Store | Fire Door (no tag - door installed in 2018) | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | GQ15 | South Corridor to G84 | Fire Doors (tag 'Spartan 2018') | Insulation Core | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | 3 | 3Q2 | Fire Stairs | Fire Door (tag 'Spartan 2018') | Insulation Core | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | 2Q9 | Fire Stairwell Entrance | Fire Door (no tag) | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D14 | UNSW Hall | 03 | EB3Q01 | 3Q1 Corridor, Electrical Cupboard (DB-12) | Within Electrical Cabinet | Electrical Backing Board | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAA | Block A | G | - | Exterior, Northern Side | Eave Lining | Fibre Cement Sheeting | Negative | - | - | - | RiskTech was advised that this item was sampled by independent company and returned a negative result for asbestos | N/A |
KENC | Kensington Campus | K17 | Building K17 | 6 | 6Q03 | Electrical Cupboard | Door Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | J12 | Newton | G | - | Lift No.44 | Floor Covering | Vinyl Tiles (Black Colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | J12 | Newton | 3 | 313 | Under Carpet | Floor Covering | Vinyl Tiles (Cream Colour) | - | - | - | - | Item Removed: No removal documentation provided. | Yes |
KENC | Kensington Campus | F13 | Science Theatre | LG | LG1 | On Top of Electrical Backing Board | Debris | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F13 | Science Theatre | LG | LG1 | On Top of Electrical Backing Board | Debris | Fibre Cement Sheet | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F13 | Science Theatre | LG | LG1 | - | Ceiling Beams | Sprayed Insulation (vermiculite) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | 6Q4 | Electrical Riser Cupboard | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | R2 | Lift Motor Room | Lift Motor | Brake Pads | Suspected Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | R2 | Plant Room | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | R2 | Tank Room Above R2 | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | 1004 | North | Windows | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | LR | R1Q01 | Exterior, Adjacent Room R2, Ceiling | Infill Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | N8 | House at Pooh Corner | - | - | Exterior, North West of Main Building, Shed | Roof | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G1 | - | Floor Covering | Adhesive Beneath Vinyl Floor Tiles & Floor Surface | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G14 | - | Ceiling | Decorative Vermiculite Coating (on metal) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G11 | - | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G19 | - | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | N8 | House at Pooh Corner | - | - | Exterior | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | 03 | Lift 33 | Lift Car | Floor Covering | Vinyl Floor Tiles (blue colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G6 | Blockhouse | - | - | Exterior, North | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G6 | Blockhouse | G | G8D | - | Floor Covering | Vinyl Floor Tiles (black colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 1Q05 | - | Floor Covering | Vinyl Sheeting (beige colour beneath carpet) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 212 | - | Flooring | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 212 | - | Flooring | Vinyl Floor Tiles (blue colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 2Q05 | North | Window Beading | Sealant Mastic | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | 180 | - | Ductwork | Fibre Cement Sheet Glue | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | 130A | Plant Room | Soffit Surrounding Columns | Insulation (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | 130A | Plant Room | Ceiling | Insulation (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 3 | 305 | - | Beams | Insulation (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 3 | 324 | Cleaners Room | Beams | Insulation (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | 1Q9 | - | Soffit Surrounding Columns | Insulation (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 2 | - | Exterior, Old Northern Section, Perimeter Awning | Soffit | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 3 | - | Exterior, Old Northern Section, Perimeter Awning | Soffit | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 3 | 301 | - | Fire Door (no tag) | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 4 | - | Old Northern Building Section, Roof Space | On Top of Concrete Slab | Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 4 | - | Exterior, Old Northern Building Section, Perimeter Awning | Soffit | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 15 | 1502 | Boiler Room | Boiler, Flange | Gasket | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | LG | LG10 | - | Floor Covering | Vinyl Floor Tiles (grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | LG | LG30 | - | Window Beading | Sealant Mastic | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | LG | LGQ2A | - | Ceiling (soffit) | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | G | G2A | - | Window Beading | Sealant Mastic | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | G | G37 | - | Ceiling (soffit) | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | G | G37 | - | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | LG | LG13 | - | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | 01 | 1Q2 | Previously Room 126 | Floor Covering | Vinyl Floor Tiles (beige colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | 01 | 1Q4 | - | Floor Covering | Vinyl Floor Tiles (beige colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | 01 | 1Q4 | - | Ceiling (soffit) | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | 02 | 2Q3A | - | Ceiling (soffit) | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | 02 | 2Q3 | - | Window Beading | Sealant Mastic | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | 02 | 238 | - | Floor Covering (under carpet) | Vinyl Floor Tiles (beige colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | 02 | 2Q1 | - | Floor Covering (under carpet) | Vinyl Floor Tiles (beige colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | 02 | 2Q3 | - | Ceiling (soffit) | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | 03 | 3Q3 | - | Ceiling (soffit) | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | 03 | 3Q4 | - | Floor Covering (under carpet) | Vinyl Floor Tiles (beige colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | 03 | 3Q4 | - | Window Beading | Sealant Mastic | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | O14 | Kangas House | G | 50 | - | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | O14 | Kangas House | G | 53 | - | Floor Covering | Vinyl Floor Tiles (blue colour) | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | O14 | Kangas House | B | - | Store Under Room 5A | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | O14 | Kangas House | G | 2 | - | Floor Covering | Vinyl Floor Tiles (light brown colour - beneath other floor coverings) | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | O14 | Kangas House | G | 3 | - | Floor Covering | Vinyl Floor Tiles (dark brown colour - beneath other floor coverings) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | G | GQ06 | Cleaners Cupboard | Floor Covering | Adhesive (attached to vinyl tiles) | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R1 | Randwick R1 | 01 | - | Roof Space Throughout | Air Conditioning Ductwork Heater Bank | Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | 105 | - | Air Conditioning Ductwork Heater Unit | Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | B | BQ2 | Adjacent Room B4 | Air Conditioning Ductwork Heater Unit | Millboard Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | J12 | Newton | G | G06 | - | Floor Covering | Vinyl Tiles (Beige Colour) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Bio Sciences North | 6 | R3 | Plant Room | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive - Removed | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
Kenc | Kensington Campus | D26 | Bio Sciences North | LG | LG01 | Biosciences North | Pipe | Insulation | Removed - Suspected Positive | - | - | - | Item Removed: Refer to NAA Clearance Certificate (Ref: J121397) dated 12 August 2013. | Yes |
DPFS | David Phillips Field | DP1 | Central Amenities Block | G | GQ2 | Throughout | Cubicle Partitions | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP1 | Central Amenities Block | G | GQ4, GQ5, GQ6, GQ7, G07, G08 | Throughout | Cubicle Partitions | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP1 | Central Amenities Block | G | GQ3 | Throughout | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
DPFS | David Phillips Field | DP1 | Central Amenities Block | G | - | Northern Male Change Room, West | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
DPFS | David Phillips Field | DP1 | Central Amenities Block | G | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
DPFS | David Phillips Field | DP1 | Central Amenities Block | G | G01 | Throughout | Floor Covering | Sheet Vinyl (grey colour) | Suspected Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP2 | West Amenties Block | G | GQ7 | Change Room | Cubicle Partitions | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP2 | West Amenties Block | G | G05 | Change Room | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP2 | West Amenties Block | G | GQ6 | Change Room | Cubicle Partitions | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP2 | West Amenties Block | G | GQ8 | Change Room | Cubicle Partitions | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP2 | West Amenties Block | G | GQ9 | Change Room | Cubicle Partitions | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP2 | West Amenties Block | G | G03 | Change Room | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K14 | Physics Theatre | LG | LG11C | - | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
DPFS | David Phillips Field | DP2 | West Amenties Block | G | G04 | Change Room | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
MANV | Manly Vale | MV7 | Laboratory 4 | G | G05 | - | Floor Covering | Vinyl Tiles (blue colour) | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV9 | Laboratory 3 | G | G01 | - | Within Electrical Cabinet | Electrical Backing Board | Negative | - | - | - | - | N/A |
DPFS | David Phillips Field | DP2 | West Amenties Block | G | GQ2 | Change Room | Cubicle Partitions | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
MANV | Manly Vale | MV3 | Laboratory 2 | G | - | Throughout | Wall | Adhesive | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G01 | South-West | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV3 | Laboratory 2 | G | GQ2 | - | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
DPFS | David Phillips Field | DP2 | West Amenties Block | G | GQ3 | Change Room | Cubicle Partitions | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP2 | West Amenties Block | G | GQ4 | Change Room | Cubicle Partitions | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP2 | West Amenties Block | G | GQ5 | Change Room | Cubicle Partitions | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP2 | West Amenties Block | G | G06 | Change Room | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
DPFS | David Phillips Field | DP2 | West Amenties Block | G | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV12 | Cool Room | G | G01 | - | Floor Covering | Sheet Vinyl (beige colour) | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV1 | Laboratory 1 | G | G01 | Table Top | Access Hatch | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV1 | Laboratory 1 | G | - | Exterior, East | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV1 | Laboratory 1 | G | - | Exterior | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV1 | Laboratory 1 | G | G03 | - | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | E10 | Hilmer Building | B-9 | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | E10 | Hilmer Building | B-9 | - | Electrical Cupboards Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | WR45 | 45 Wansey Road | G | - | Exterior, Entrance | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | E10 | Hilmer Building | B-9 | - | Hydraulic Risers Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | E10 | Hilmer Building | B-9 | - | Mechanical Risers Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | E10 | Hilmer Building | B-9 | - | Communications Risers Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | E10 | Hilmer Building | B-9 | - | Throughout | Fire Doors (tagged 'Ikon, 2014') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | E14 | Pump Room | G | G01 | Central | Pump Exhaust Flue | Insulation Material | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | E14 | Pump Room | - | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | E14 | Pump Room | G | G01 | - | Sprinkler Pumps | Gaskets (rubber) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E19 | Central Lecture Block | LG | - | Exterior, West, Adjacent entrance to Room LG06 | Eaves | Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | E19 | Central Lecture Block | 01 | - | Roof Space | Steel Beams & Adjacent Surfaces | Insulation Residue | Positive (Amosite) | Friable | Low | P3 | Restrict access to the roof space to authorised personnel only. Remedial works must be undertaken under controlled conditions by a Class A contractor as part of a planned control program. | No |
KENC | Kensington Campus | E19 | Central Lecture Block | 01 | 104 | South Duct & Fire Hose Reel Room, Small Localised Areas | On Walls | Insulation Residue | Removed | - | Items removed. Refer Risktech clearance certifiacte dated 17/08/2019 | Yes | ||
KENC | Kensington Campus | E19 | Central Lecture Block | 01 | 104 | South Duct & Fire Hose Reel Room, Within Wall Cavity for Hose Reel | On Walls & Genral Surfaces | Insulation Residue & Debris | Removed | - | Items removed. Refer Risktech clearance certifiacte dated 17/08/2019 | Yes | ||
KENC | Kensington Campus | E19 | Central Lecture Block | 01 | 104 | North Duct & Fire Hose Reel Room, Within Wall Cavity for Hose Reel | On Timber Ceiling Framework | Insulation Residue | Removed | - | Items removed. Refer Risktech clearance certifiacte dated 17/08/2019 | Yes | ||
KENC | Kensington Campus | E19 | Central Lecture Block | L | - | Exterior, Eastern Side of Building | Window Frames (between frame and brickwork) | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E19 | Central Lecture Block | 01 | 1Q3 | Adjacent Entrance to Room 102 and 106 | Window Frames (between frame and pane) | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E19 | Central Lecture Block | G | - | Exterior, Eastern Side of Building | Window Frames (between frame and pane) | Mastic Sealant | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E19 | Central Lecture Block | 01 | - | Exterior, Eastern Side of Building | Window Frames (between frame and pane) | Mastic Sealant | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E19 | Central Lecture Block | G | G08 | Throughout | Toilet Cubicle Partition | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E19 | Central Lecture Block | 01 | 104A | Duct off Room 104A | On Floor | Insulation Debris | Removed | - | Items removed. Refer Risktech clearance certifiacte dated 17/08/2019 | Yes | ||
KENC | Kensington Campus | E19 | Central Lecture Block | 01 | 104B | Duct off Room 104B | On Floor | Insulation Debris | Removed | - | Items removed. Refer Risktech clearance certifiacte dated 17/08/2019 | Yes | ||
RANC | Randwick Campus | R6 | Randwick R6 | G | - | Exterior, North & South | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R5 | Randwick R5 | G | - | Exterior, North and South | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R4 | Randwick R4 | G | - | Exterior, North & South | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E19 | Central Lecture Block | G | - | Exterior, Eastern Side of Building | Window Frames (between frame and brickwork) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E19 | Central Lecture Block | G | G01A | South | Window Frames (between frame and pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E19 | Central Lecture Block | G | G01B | North | Window Frames (between frame and pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E19 | Central Lecture Block | 01 | - | Exterior, Eastern Side of Building | Window Frames (between frame and brickwork) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E19 | Central Lecture Block | L | - | North-East and South-East | Window Frames (between frame and pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E19 | Central Lecture Block | 01 | 102 | Throughout | Window Frames (between frame and pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E19 | Central Lecture Block | 01 | 103 | South-East | Window Frames (between frame and pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E19 | Central Lecture Block | 01 | 105 | North-East | Window Frames (between frame and pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R1f | Randwick R1f | G | - | Exterior, Throughout | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R1e | Randwick R1e | G | - | Exterior, North | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R1d | Randwick R1d | G | - | Exterior, North | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R1c | Randwick R1c | G | - | Exterior, Surrounding | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R1b | Randwick R1b | G | - | Exterior, Surrounding | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R1a | Randwick R1a | G | - | Exterior, Surrounding | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E19 | Central Lecture Block | 01 | 106 | North-East | Window Frames (between frame and pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R1 | Randwick R1 | G | G50 | Plant Room, South Wall | Within Electrical Cabinet | Electrical Backing Board | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R1 | Randwick R1 | 01 | 112A | Toilet | Partition Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R1 | Randwick R1 | 01 | 111A | - | Window Frames | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E19 | Central Lecture Block | L | - | Exterior, Eastern Side of Building | Window Frames (between frame and pane) | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E19 | Central Lecture Block | G | UCA | Throughout | Awning | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E19 | Central Lecture Block | G-1 | - | Exerior, Throughout | Vertical Expansion Joints | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E19 | Central Lecture Block | LG | LG01 | Plant Room | Steel Beams | Sprayed Insulation (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E19 | Central Lecture Block | LG | LG07 | Exterior, Shed | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E19 | Central Lecture Block | G | G09 | Throughout | Toilet Cubicle Partition | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E19 | Central Lecture Block | L | L03 | Throughout | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E19 | Central Lecture Block | L | L03 | Behind Chalk Board | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E19 | Central Lecture Block | LG | - | Exterior, West, Grounds Store Adjacent to Room LG07 | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E19 | Central Lecture Block | LG | LG01 | - | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E19 | Central Lecture Block | LG | LG02 | Throughout | Fire Door (tag: year of manufacture - 2005) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E19 | Central Lecture Block | LG | LG02 | - | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E19 | Central Lecture Block | LG | LG03 | Throughout | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E19 | Central Lecture Block | G | - | Exterior, Extended Eastern Section | Support Columns | Moulded Fibre Cement Pipes | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 6 | 6Q05 | Cleaners Cupboard | Floor Covering | Adhesive (attached to vinyl tiles) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 7 | 701 | - | Floor Covering | Adhesive (attached to vinyl tiles) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | B | BQ03 | Electrical Cupboard | Door Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | B | BQ01 | Central, Hallway | Columns / Pylon | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | G | GQ03 | Electrical Cupboard | Door Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 1 | 111D | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 1 | 111D | Under Carpet | Floor Covering | Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 1 | 1Q02 | Electrical Cupboard | Door Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 1 | 1Q02 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 1 | 1Q01 | Stairwell, Central | Columns / Pylon | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 1 | 101 | Central | Columns / Pylon | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q03 | Cleaners Cupboard | Floor Covering | Adhesive (attached to vinyl tiles) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q03 | Electrical Cupboard | Door Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q01 | Stairwell, Central | Columns / Pylon x3 | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 3 | 3Q02 | Electrical Cupboard | Door Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 3 | 301 | North | Columns / Pylon x3 | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 4 | 4Q06 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 4 | 4Q06 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 4 | 412 | Electrical Cupboard | Door Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 4 | 401 | North | Columns / Pylon x3 | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 5 | 5Q01 | - | Floor Covering | Adhesive (attached to vinyl tiles) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 5 | 510 | Electrical Cupboard | Door Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 5 | 501 | North | Columns / Pylon x3 | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 6 | 604 | North | Columns / Pylon | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 4 | 4Q03 | Hallway | Insulation Board | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 7 | 7Q02 | Wall | Penetration Block | Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | G | G42 | - | Floor Covering | Vinyl Tiles (blue colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | G | G42 | - | Floor Covering | Vinyl Tiles (beige colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | G | GQ10 | - | Floor Covering | Vinyl Tiles (light green colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K14 | Physics Theatre | G | G19 | Ceiling Space | Steel Beams | Sprayed Insulation (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | G | G19 | Ceiling Space | Soffit | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | LG | LG22 | - | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | LG | LGQ12 | - | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | G | G32 | - | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | G | G12 | - | Floor Covering | Vinyl Tiles (light blue colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | G | G14 | - | Floor Covering | Vinyl Tiles (grey colour - large) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | G | G14 | - | Floor Covering | Vinyl Tiles (green colour - large) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | G | G16 | - | Floor Covering | Vinyl Tiles (grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 01 | 153 | Duct Riser, Wall | Sprayed Insulation | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 01 | 142 | - | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q19 | - | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q18 | Corridor to Newtown Building | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 01 | 101 | - | Floor Covering | Vinyl Tiles (light green colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 01 | 101 | - | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 01 | 101 | - | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 02 | 210F | Toilet | Cubicle Partition Wall | Compressed Fibre Cement Sheet | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 02 | 2Q7 | Electrical Cupboard | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 02 | 227 | - | Floor Covering | Vinyl Tiles (grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 02 | 230 | - | Window Frames | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 02 | 238 | - | Floor Covering | Vinyl Tiles (flexible dark blue colour) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | J14 | Keith Burrows Theatre | G | G03 | Male Toilet | Partition Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | J14 | Keith Burrows Theatre | G | G06 | Female Toilet, Central | Partition Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | J12 | Newton | 3 | 310 | North | Windows | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | G | - | Exterior, North West Section | Wall Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22A | Garbage Disposal Unit H22A | G | 01 | Exterior Throughout | Wall Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 2Q1 | Throughout | Floor Covering | Adhesive attached to Blue, Grey & White Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 2Q4 | Throughout | Floor Covering | Adhesive attached to Blue, Grey & White Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 3Q1 | Throughout | Floor Covering | Adhesive attached to Blue, Grey & White Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 3Q4 | Throughout | Floor Covering | Adhesive attached to Blue, Grey & White Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 315, 316 & 316B | Previously 310 & 310A, Throughout | Floor Covering | Adhesive attached to Blue, Grey & White Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 4Q2 | Throughout | Floor Covering | Adhesive attached to Blue, Grey & White Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 4Q4 | Throughout | Floor Covering | Adhesive attached to Blue, Grey & White Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 5Q2 | Throughout | Floor Covering | Adhesive attached to Blue, Grey & White Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 5Q4 | Throughout | Floor Covering | Adhesive attached to Blue, Grey & White Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG6 | Throughout | Floor Covering | Adhesive attached to Aqua Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG6A | Throughout | Floor Covering | Adhesive attached to Aqua, Grey & White Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 1Q1 | Throughout | Floor Covering | Adhesive attached to Blue, Grey & White Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 1Q6 | Throughout | Floor Covering | Adhesive attached to Blue, Grey & White Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 206 | Throughout | Floor Covering | Adhesive attached to Light Green Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 301 | Throughout | Floor Covering | Adhesive attached to Grey & Aqua Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 408 | Throughout | Floor Covering | Adhesive attached to Blue & Black Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 601 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 601A | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 601B | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 602 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 602A | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 603 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 604 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 605 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 607 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 608 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 610 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 611 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 611A | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 611B | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 612 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 613 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 614 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 615 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 616 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 617 | Throughout | Floor Covering | Adhesive attached to BlueVinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 6Q2 | Throughout | Floor Covering | Adhesive attached to Blue, Grey & White Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 6Q4 | Throughout | Floor Covering | Adhesive attached to Blue, Grey & White Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 7Q2 | Throughout | Floor Covering | Adhesive attached to Blue, Grey & White Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 7Q4 | Throughout | Floor Covering | Adhesive attached to Blue, Grey & White Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG11 | Throughout | Floor Covering | Adhesive attached to Green Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG6 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LGQ1 | Throughout | Floor Covering | Adhesive attached to Mustard & Aqua Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LGQ2 | Throughout | Floor Covering | Adhesive attached to Mustard & Aqua Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG3 | Throughout | Floor Covering | Adhesive attached to Mustard Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | G | GQ2 | Hallway Adjacent Lift Lobby | Floor Covering | Adhesive attached to Grey & Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | G | G4 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 101 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 201-205 & 207-213 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 301-304, 306-313 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 401A-415 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 501 | Perimeter | Windows | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 501 | Throughout | Floor Covering | Adhesive attached to Aqua, White & Light Gree Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 501-514 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 601-616 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 7Q1 | Lift 31 | Floor Covering | Vinyl Tiles (Black Colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 7Q1 | Lift 32 | Floor Covering | Vinyl Tiles (Black Colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 709 | Throughout | Floor Covering | Adhesive attached to Light Green Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 401 | Throughout | Floor Covering | Adhesive attached to Grey Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 401A | Throughout | Floor Covering | Adhesive attached to Grey Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 402 | Throughout | Floor Covering | Adhesive attached to Grey Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 404 | Throughout | Floor Covering | Adhesive attached to Grey Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 404A | Throughout | Floor Covering | Adhesive attached to Grey Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 406A | Throughout | Floor Covering | Adhesive attached to Grey Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 406 | Throughout | Floor Covering | Adhesive attached to Grey Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 416 | Throughout | Floor Covering | Adhesive attached to Grey Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 701-719 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 701 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 702 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 703 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 704 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 705 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 706 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 707 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 708 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 710 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 712 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 713 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 715 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 716 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 717 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 717A | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 717B | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 717C | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 718 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 719 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 711 | Throughout | Floor Covering | Adhesive attached to Grey & Dark Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 711A | Throughout | Floor Covering | Adhesive attached to Grey & Dark Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 720 | Throughout | Floor Covering | Adhesive attached to Grey Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | 802 | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | 802A | Throughout | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | RQ06 | Eastern Roof Area | Pipe Work | Gasket | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | R1 | Plant Room | Pipe Work | Woven Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H13 | The Red Centre | 02 | 2Q30 | Throughout | Ceiling Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H13 | The Red Centre | 02 | 2Q30 | Throughout | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | LG | LG07B | (Previously Room LG07F), Throughout | Ceiling | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | LG | LG02 | Throughout | Floor Covering | Vinyl Tiles (off white colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | 2 | 201-235 | Throughout | Ceiling | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | 3 | 302-325 | - | Ceiling | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E19 | Central Lecture Block | R | - | Roof, North-East and South-East | Eaves | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | E24 | The Pavillions | G | - | Throughout Building | No asbestos materials identified or suspected | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | E24 | The Pavillions | G | - | Internal - East Side, SE Corner | Inside Electrical Cabinet (new appearance cabinet) | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | FBV01 | Fire Booster Valve Set Gate 7 High Street | G | - | No asbestos materials identified | - | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F25 | Samuels | LG | LG8A | Throughout | Floor Covering | Sheet Vinyl (light green colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F25 | Samuels | G | G05A | Throughout | Floor Covering | Sheet Vinyl (grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F25 | Samuels | G | G07 | Throughout | Floor Covering | Sheet Vinyl (white colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F25 | Samuels | 1 | 1Q3 | Throughout | Floor Covering | Sheet Vinyl (grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F25 | Samuels | 1 | 1Q3 | Throughout | Floor Covering | Sheet Vinyl (orange colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F25 | Samuels | 3 | 328 | Throughout | Floor Covering | Sheet Vinyl (grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F25 | Samuels | R | R07 | Throughout | Floor Covering | Sheet Vinyl (orange colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F22 | Bank | 01 | - | Exterior, West | Expansion Joint | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F22 | Bank | 01 | - | Exterior, South | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F22 | Bank | 01 | 104 | Australia Post - Store | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F22 | Bank | - | - | Exterior, North | Wall Expansion Joints | Bituminous Mastic Sealant (membrane) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F22 | Bank | 01 | - | Exterior, North | Wall (ATM) | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F22 | Bank | 02 | 208 | Formerly Room 207 | Floor Covering | Sheet Vinyl (black colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | LG | LG2 | - | Boiler, Flange | Gasket | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F13 | Science Theatre | G | G15 | South | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F13 | Science Theatre | G | G15 | Throughout | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E6 | Roundhouse | 01 | Former Room 102 | Throughout | Pipework Flange Joint | Mastic Sealant | Negative | - | - | - | N/A | |
KENC | Kensington Campus | E4 | Squarehouse | 03 | 3Q4 | North Electrical Cupboard | Door Lining | Compressed Fibre Cement Sheet | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E4 | Squarehouse | G | G6 | Possibly Beneath Sheet Vinyl | Floor Covering | Vinyl Tiles (beige colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E4 | Squarehouse | 02 | - | Exterior Verandah | Floor Expansion Joint | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E4 | Squarehouse | - | - | Lift Car | Floor Covering | Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E4 | Squarehouse | 03 | 3Q3 | Under Sheet Vinyl | Floor Covering | Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | FBV01 | Fire Booster Valve Set Gate 7 High Street | G | - | Central | Pipework Flange Joints | Gaskets (rubber) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | FBV02 | Fire Booster Valve Set Gate 11 Botany Street | G | - | No asbestos materials identified | - | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | FBV02 | Fire Booster Valve Set Gate 11 Botany Street | G | - | Central | Pipework Flange Joints | Gaskets (rubber) | Suspected Negative | - | - | - | - | No |
FSFG | Fowlers Gap Field Station | FG11 | Fowlers Gap - Carpenters Hut Tool Shed | G | - | Exterior, Surrounding Shed | On Ground Surfaces | Fibre Cement Sheeting Debris | Positive - Removed | - | - | - | Demolished-'Item Removed: UNSW site personnel informed RiskTech that fibre cement debris removed. RiskTech also removed fibre cement debris as part of the inspection process. | Yes |
FSFG | Fowlers Gap Field Station | FG11 | Fowlers Gap - Carpenters Hut Tool Shed | G | G01 | - | Stored Sheets | Fibre Cement Sheets (x 2) | Positive - Removed | - | - | - | Demolished-'Item Removed: UNSW site personnel informed RiskTech that fibre cement sheets removed. No stored asbestos containing fibre cement sheets sighted by RiskTech during the inspection. | Yes |
FSFG | Fowlers Gap Field Station | FG11 | Fowlers Gap - Carpenters Hut Tool Shed | G | G01 | Northern Room | Stored Sheets (some sheets labelled 'Manufactured Without Asbestos') | Fibre Cement Sheets (x 3) | Negative | - | - | - | Demolished | Yes |
FSFG | Fowlers Gap Field Station | FG11 | Fowlers Gap - Carpenters Hut Tool Shed | G | G01 | Southern Room | Stored Asbestos Waste | Fibre Cement Sheeting | Removed | - | - | - | Demolished-'Refer RiskTech 2023 survey. Item removed by onsite personnel | Yes |
KENC | Kensington Campus | E15 | Quadrangle | 02 | - | Exterior | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E4 | Squarehouse | 02 | 2Q3 | - | Floor Covering | Vinyl Tiles (grey colour) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D9 | IO Myers Studio | G | - | Exterior, Surrounding | Wall Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D9 | IO Myers Studio | G | G01A | Toilets | Partition Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D9 | IO Myers Studio | G | G04 | - | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D9 | IO Myers Studio | G | G04 | Throughout | Window Frames | Mastic Sealant | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | - | Exterior, South-West | Telecommunications Pit | Moulded Fibre Cement Material | Positive (Amosite & Chrysotile) | Non-friable | Low | P3 | Seal damaged rim of service pit under controlled conditions by a Class A/B contractor or competent person within a planned control program. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 02 | 206A | Entrance | Fire Door (no tag) | Core Insulation | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D16 | Goldstein Hall | G | - | Exterior, East | Pipe | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D16 | Goldstein Hall | G | G15A | - | Cubicle Partitions | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D16 | Goldstein Hall | 02 | 202 | - | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D16 | Goldstein Hall | 02 | 201 | - | Floor Covering | Adhesive (Attached to Sample 53038-D16-01A) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D14 | UNSW Hall | G | CG22 | Throughout | Cubicle Partitions | Compressed Fibre Cement | Negative | - | - | - | N/A | |
KENC | Kensington Campus | D14 | UNSW Hall | G | CG20 | Windows | Infill Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | A199 | Throughout | Cubicle Partitions | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | A198 | Windows | Infill Panel | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | A299 | Throughout | Cubicle Partitions | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | 2Q7 | Fire Stairwell Entrance | Fire Door (no tag) | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | C298 | Windows | Infill Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D14 | UNSW Hall | 03 | C398 | Windows | Infill Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D14 | UNSW Hall | 03 | C395 | Throughout | Cubicle Partitions | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAE | Block E | G | - | Exterior | Infill Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAE | Block E | B | EB03 | - | Heat Mat | Fibre Cement Sheeting | Positive | - | - | - | UNSW building managers did not remove all the friable asbestos from this area, only enough to do the new pipe connection. There is still Asbestos in the wall. | No |
COFA | Paddington Campus | CFAE | Block E | B | EB50 | - | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAE | Block E | B | EB10 | - | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAE | Block E | 01 | E110 | - | Window Frames | Mastic Sealant | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAE | Block E | 01 | E105 | - | Window Frames | Mastic Sealant | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAE | Block E | 01 | E101 | - | Window Frames | Mastic Sealant | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAA | Block A | G | AGQ1 | - | Floor Covering | Vinyl Tiles | Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 02 | 259 | - | Floor Covering | Vinyl Tiles (grey colour) | Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC4 | Building CC4 | G | G02 | - | Floor Covering | Vinyl Tiles (grey colour) | Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 01 | 116A | Toilet | Partition Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | - | Exterior, All Sides | Walls | Profiled Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | GQ3 | Western End, Toilets/Showers | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | GQ4 | Western End, Toilets/Showers | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | - | Exterior, Northern Side, NE Corner | Low Level Wall Panelling | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | - | Exterior, All Sides | Eaves | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | - | Exterior, Subfloor Space | On Ground Surface | Fibre Cement Sheet Debris | Assumed Positive | Non-friable | Med | P3 | Restrict access to the sub floor space to authorised personnel only. Remove fibre cement debris under controlled conditions by a Class A/B Contractor or competent person prior to demolition or refurbishment or when access is required. | No |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | G01 | Eastern End, Kitchen/Media Room | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | G01A | Eastern End, Kitchen/Media Room | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | G02 | South-East Dormitory Room, North & East Sides | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | G03 | Mid-South Dormitory Room, South Side | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | G04 | South-West Dormitory Room, North, South & West Sides | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | G05 | North-West Dormitory Room, North, South & West Sides | Walls (Note: localised damaged area - temporarily covered) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Remedial works should be undertaken by a Class A/B Contractor or competent person within a planned control program. | No |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | G06 | Mid-North Dormitory Room, North and South Sides | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | G07 | North-East Dormitory Room, North, South & East Sides | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | G08 | Far North-West Corner, Laundry | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | G08 | Far North-West Corner, Laundry | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG66 | - | Wall | Fibre cement sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG66 | Above Set Ceiling | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | LG | LGQ7 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG1 | Exterior, Undercroft | Awning | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG66 | - | Column | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG57A | Exterior | Awning Ceiling | Fibre cement sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG57A | Exterior | Wall Cladding | Fibre cement sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG51 | Throughout | Cable | Rope | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG56 | North | Expansion Joint | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG66A | Horizontal Window | Infill Panels | Fibre cement sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG54 | Throughout | Floor Covering | Vinyl Floor Tiles (cream colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ12 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ6 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ6 | Exterior | Window Sill Expansion Joint | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ6 | Adjacent Window | Floor and Ceiling of Window Sill | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ6 | Under Carpet | Floor Covering | Vinyl Floor Tiles (cream colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ5 | Under Sheet Vinyl | Floor Covering | Vinyl Floor Tiles (grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q2 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q8 | Adjacent Window | Floor and Ceiling of Window Sill | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q7 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q7 | Under Carpet | Floor Covering | Vinyl Floor Tiles (cream colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q12 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q6 | Adjacent Window | Floor and Ceiling of Window Sill | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q7 | Throughout | Ceiling | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q7 | Beneath Grey Sheet Vinyl | Floor Covering | Vinyl Floor Tiles (cream colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 236 | South | Window Beading | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q1 | Under Carpet | Floor Covering | Vinyl Floor Tiles (cream colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q12 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q10 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 311 | Cooling Unit | Floor Covering | Bituminous Membrane | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 311 | Cooling Unit | Wall Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 311 | Cooling Unit | Fire Door | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 311 | Cooling Unit | Floor Covering | Vinyl Floor Tiles (cream colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q8 | Adjacent Window | Floor of Window Sill | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q8 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q6 | Under Carpet | Floor Covering | Vinyl Floor Tiles (cream colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q1-3Q12 | Under Carpet | Floor Covering | Vinyl Floor Tiles (light blue colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q5 | Under Carpet | Floor Covering | Vinyl Floor Tiles (light blue colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q1-3Q12 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q6 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | GQ1 | Corridor Outside Dormitory Rooms | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
KENE | Kensington Environs | BS30 | 30 Botany Street | 1 | 104 | Kitchen | Floor Covering | Vinyl Tiles | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | BS26 | 26 Botany Street | G | - | Exterior, South-West Rear Sunroom | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | BS26 | 26 Botany Street | G | 10 | - | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | - | Squash Courts (B7), Exterior, East | Infill Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | G44 | Squash Courts (B7) | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 01 | 140 | Squash Courts (B7) | Expansion Wall Joint | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 02 | 2Q4 | Squash Courts (B7) | Expansion Joint | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 02 | 2Q1 | Gymnasium (B5), Throughout | Floor Covering | Vinyl Tiles (green colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | P10 | Pool (B4), Boiler | Pipework | Rope Gasket | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | AS24 | 24 Arthur Street | G | G08 | Exterior | Wall Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | AS24 | 24 Arthur Street | G | G11 | - | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | AS24 | 24 Arthur Street | G | G11 | - | Floor Covering | Vinyl Tiles (grey colour) | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | AS8 | 8 Arthur Street | G | - | Exterior, Throughout | Wall Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | AS8 | 8 Arthur Street | G | - | Exterior, Garage, Surrounding | Wall Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | AS8 | 8 Arthur Street | G | - | Garage | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | AS8 | 8 Arthur Street | G | - | Bathroom | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | A27 | Golf House | G | G06 | - | Floor Covering | Vinyl Floor Tiles (grey colour) | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | A27 | Golf House | G | G01 | - | Ceiling | Sprayed Vermiculite | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | GQ2 | Airlock Outside Toilets/Showers | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
RANC | Randwick Campus | R1 | Randwick R1 | LG | - | Passage | Floor Covering | Vinyl Tiles (black colour) | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R1 | Randwick R1 | G | G28/ G29 | Canteen Toilet | Partition Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R1 | Randwick R1 | G | - | Exterior, Extension, South-West | Wall Panelling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R1 | Randwick R1 | G | - | Exterior, Eastern Entrance | Awning | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R1 | Randwick R1 | G | G15 | Wash-Off Area | Floor Covering | Vinyl Tiles (blue colour) | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R1 | Randwick R1 | G | G22 | Wash-Off Area | Floor Covering | Vinyl Tiles (blue colour) | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R1 | Randwick R1 | G | G29 | - | Floor Covering | Vinyl Tiles (brown colour) | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R1 | Randwick R1 | G | G34A/G35A | Ceiling Space, Southern Toilets | Window Frames | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | 4 | 401 | Lift Motor Room (No.12) | Lift Motors | Brake Pads | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | G01 | Eastern End, Kitchen/Media Room | Floor Covering | Sheet Vinyl | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | G01A | Eastern End, Kitchen/Media Room | Floor Covering | Sheet Vinyl | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | - | Exterior, Surrounding Building | On Ground Surface | Fibre Cement Sheet Debris | Assumed Positive - Removed | - | - | - | Item removed: UNSW site personnel informed RiskTech that fibre cement debris removed. No fibre cement debris sighted by RiskTech during the inspection. | Yes |
FSFG | Fowlers Gap Field Station | FG20 | Fowlers Gap Dormitory | G | - | Exterior, North and South Entrances | Flooring | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1113 | East | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1604 | - | Air Conditioning Ductwork Heater Unit | Millboard Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 140B | - | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 145 | - | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 201A | - | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 306 | - | Window Beading | Sealant Mastic | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 401B | - | Window Beading | Sealant Mastic | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 417 | - | Floor Covering (under carpet) | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 624 | - | Floor Covering (under carpet) | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 522 | Former Room 522 - now Room 520 | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q8 | - | On Floor | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 731 | - | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1027 | - | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 838 | - | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 18 | 1801 | - | Floor Covering | Vinyl Floor Tiles (cream colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 901 | - | Floor Covering (under carpet) | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1127 | - | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1101 | - | Window Beading | Sealant Mastic | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1201 | - | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1201 | - | Window Beading | Sealant Mastic | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 1327 | - | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 1429 | - | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 1401 | - | Window Beading | Sealant Mastic | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1628 | - | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1629 | Former Room 1601 | Window Beading | Sealant Mastic | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1534 | - | Floor Covering | Vinyl Floor Tiles (cream colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 15Q3 | - | Wall | Sealant Mastic | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1517A | - | Wall (behind ceramic tiles) | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1501 | - | Window Beading | Sealant Mastic | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG7 | Fowlers Gap Generator Hut | G | G01 | North, South & West Sides | Walls (Note: localised damaged areas) | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Med | P3 | Repair / seal localised damaged areas under controlled conditions by a licensed asbestos contractor or competent person within a planned control program. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG7 | Fowlers Gap Generator Hut | G | G01 | - | Ceiling Note: localised damaged areas) | Fibre Cement Sheeting | Assumed Positive | Non-friable | Med | P3 | Repair / seal localised damaged areas under controlled conditions by a licensed asbestos contractor or competent person within a planned control program. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works | No |
FSFG | Fowlers Gap Field Station | FG7 | Fowlers Gap Generator Hut | G | G01 | - | On Ground, Stored | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG7 | Fowlers Gap Generator Hut | G | G01 | Central | Generator Unit | Gaskets | Removed | - | - | - | Refer RiskTech 2023 survey. Item removed by onsite personnel. New generator unit installed. | Yes |
KENC | Kensington Campus | G14 | Robert Webster | G | G23 | Plant Room, Soffit (pipe protruding from underside of concrete slab) | Pipe Work | Moulded Fibre Cement | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G14 | Robert Webster | G | G14A | Service Tunnel, Below Building, Near East End, South Side (access via Room G14A & Main Service Tunnel) | Electrical Conduits - Pipes | Moulded Fibre Cement | Positive (Chrysotile & Crocidolite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G14 | Robert Webster | 1 | 1Q8 | Stairwell | Windows | Mastic Sealant | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G14 | Robert Webster | 3 | 3Q3 | Stairwell | Windows | Mastic Sealant | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G14 | Robert Webster | 2 | 201-258 | Ceiling Space | Steel Beams | Vermiculite Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G14 | Robert Webster | 1 | - | Exterior, Balcony | Beam Cladding | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G14 | Robert Webster | 1 | - | Exterior, West Side | Ceiling/ Soffit | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G14 | Robert Webster | 2 | - | Exterior, Balcony | Beam Cladding | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G14 | Robert Webster | 2 | - | Exterior, West Side | Ceiling/ Soffit | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G14 | Robert Webster | 3 | - | Exterior, West Side | Ceiling / Soffit | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 303 | Throughout | Floor Covering | Adhesive (attached to vinyl tiles) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LG10E | Ceiling, Throughout | Sprayed Insulation | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LG13A | South | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LG23 | Lockers | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | - | Exterior, West Side | Wall Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G25 | South & Southwest (lower sections) | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | O14 | Kangas House | B | - | Under Room 5A (outside Room B1 & B2), Central | Column | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | O14 | Kangas House | G | 51 | North & East | Wall Infill Panelling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | O14 | Kangas House | G | - | Exterior, Eastern Building, North East Structure | Wall Panelling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | O14 | Kangas House | G | - | Exterior, Eastern Building, South & East Sides (Outside Room 63) | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G24 | North, South & East | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | MS48A | Owls House Building 2 | G | - | Exterior, South Side | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G14 | Robert Webster | 2 | 2Q4 | Stairwell | Windows | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G14 | Robert Webster | G | G10 | Old Lift Motor Room | Fire Door (no tag) | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G6 | Blockhouse | - | - | Roof, Western End, Plant Room (Air Handling Unit) | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 109 | - | Floor Covering | Vinyl Floor Tiles (beneath carpet) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 115 | - | Floor Covering | Vinyl Floor Tiles (green colour beneath carpet) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G6 | Blockhouse | G | G10A | West | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 621 | - | Air Conditioning Ductwork Heater Unit | Millboard Insulation Board | Negative | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 30 August 2019. Removed by Pure Contracting. | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 621A | - | Air Conditioning Ductwork Heater Unit | Millboard Insulation Board | Negative | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 30 August 2019. Removed by Pure Contracting. | Yes |
COFA | Paddington Campus | CFAA | Block A | B | AB3 | Plant Room | Fire Doors x 2 (no tag) | Insulation Core | Positive (Removed) | - | - | - | Item removed by Pure Contracting. Refer to RiskTech Compliance Clearance Report dated 12/11/2021. Note: New fire doors installed (tagged ' Bismac Year of Man. 2021'). | Yes |
COFA | Paddington Campus | CFAA | Block A | B | AB1 | Exterior, Covered Walkway | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAA | Block A | B | AB5 | Under Carpet Throughout | Floor Covering | Bituminous Material | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAA | Block A | G | AG08 | Beneath Carpet Tiles | Floor Covering | Compressed Fibre Cement Sheet | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | G15 | Robert Webster Theatres | 02 | 290A | Lecture Theatre B, East Side, Projector Room, Roof Space | Sprayed Ceiling - Insulation | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG56 | - | Ductwork Reheat Unit | Millboard Insulation Lining | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K14 | Physics Theatre | G | G23 | Ceiling Space | Air Conditioning Ductwork Heater Bank | Insulation Board | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | WR45 | 45 Wansey Road | G | - | Exterior, Entrance | Gable Verge Lining | Fibre Cement Sheeting | Negative | - | - | - | N/A | |
KENE | Kensington Environs | WR45 | 45 Wansey Road | G | - | Exterior, Entrance, West | Gable | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | WR41 | 41 Wansey Road | G | - | Exterior, Front Entrance | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | WR41 | 41 Wansey Road | G | - | Exterior, North, Below Windows | Infill Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | WR41 | 41 Wansey Road | LG | - | Laundry, South | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | WR41 | 41 Wansey Road | G | - | Hall | Ceiling Access Panel | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSW | Wellington Field Station | WFS1 | Wellington Field Station Cottage | G | 1 | Main Residence, Exterior, North Side, Beneath Hot Water Heater Unit | Flooring | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSW | Wellington Field Station | WFS2 | Wellington Field Station Shearing Shed | G | G01 | West Side, Toilets & Shower Room | Partition Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSW | Wellington Field Station | WFS23 | Wellington Field Station Administration | G | - | North Side | Flooring | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSW | Wellington Field Station | WFS23 | Wellington Field Station Administration | G | - | East Side | Flooring | Compressed Fibre Cement Sheeting | Negative | - | - | - | N/A | |
KENC | Kensington Campus | G14 | Robert Webster | G | - | Exterior, North Side | Wall Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G14 | Robert Webster | 2 | 230 | Ceiling Space | Steel Beams | Vermiculite Insulation | Negative | - | - | - | - | N/A |
FSSL | Smiths Lake Field Station | SL6 | Smiths Lake COLA | G | G01 | - | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSSL | Smiths Lake Field Station | SL6 | Smiths Lake COLA | G | - | Exterior | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G14 | Robert Webster | G | GQ6 | Inside Lift | Floor Covering | Vinyl Tiles (black colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G14 | Robert Webster | 3 | - | Exterior, Balcony | Beam Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G14 | Robert Webster | 3 | - | Exterior, West Side, Balcony | Wall Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G14 | Robert Webster | 1 | 1Q9 | Ceiling Space | Steel Beams | Vermiculite Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G14 | Robert Webster | 3 | 3Q6 | Electrical & Communications Cupboards | Floor Covering | Vinyl Tiles (green colour) | Negative | - | - | - | - | N/A |
FSSL | Smiths Lake Field Station | SL1 | Smiths Lake Laboratory | G | G1 | North | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G14 | Robert Webster | G | - | Throughout | Fire Doors (tagged 'State Fire Stopping, 200_' & 'Wormald, 20__') | Core Insulation | Suspected Negative | - | - | - | - | No |
FSSL | Smiths Lake Field Station | SL1 | Smiths Lake Laboratory | G | G1 | East | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSSL | Smiths Lake Field Station | SL1 | Smiths Lake Laboratory | G | G2 | North, Below Bench | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSSL | Smiths Lake Field Station | SL4 | Smiths Lake Boat Shed | G | G01 | Exterior, South | Stored Sheeting | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G14 | Robert Webster | 1 | 1Q1, 1Q3, 1Q6 & 1Q12 | - | Fire Doors (tagged 'State Fire Stopping, 200_', 'Wormald, 20__' & 'Wormald', no date) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G14 | Robert Webster | 2 | 2Q1, 2Q3 & 2Q7 | - | Fire Doors (tagged 'State Fire Stopping, 200_', 'Wormald, 20__' & R.E. Spence & Co, 2002) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G14 | Robert Webster | 3 | 3Q1, 3Q2 3Q5, 3Q8 & 3Q9 | - | Fire Doors (tagged 'State Fire Stopping, 200_', 'Wormald, 20__' & 'Wormald', no date) | Core Insulation | Suspected Negative | - | - | - | - | No |
RANC | Randwick Campus | R14 | Institute of Languages | R | - | Plant Room, Surrounding | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R1 | Randwick R1 | G | G28 | Under New Vinyl Floor Sheet | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV7 | Laboratory 4 | G | - | - | Floor Covering | Vinyl Tiles (blue colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G14 | Robert Webster | 1 | 191 | Electrical Cupboard | Electrical Switch Board | Electrical Backing Board | Suspected Positive | - | - | - | Item Removed 30/12/2013. Refer to NAA Clearance Certificate C107859:J124201 | Yes |
MANV | Manly Vale | MV12 | Cool Room | G | - | Exterior | Under Cover Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | MS48A | Owls House Building 2 | G | UG001 | Exterior, North Side, Covered Terrace | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 05 | 5Q2 | Exterior, Surrounding | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | G | - | Exterior, North of G40A | Roof Covering to Awning | Bituminous Membrane | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | LG | - | Exterior, North of LGQ3 | Window Frames | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | LG | - | Exterior, North of LGQ3 | Roof Covering | Bituminous Membrane | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | G | GQ18 | Exterior | Window Frames (between frame and pane) | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 02 | - | Exterior | Windows (between frame and brick facade) | Mastic Sealant | Assumed Positive | Non-friable | Low | P3 | Remediate (remove and/or seal) deteriorating mastic sealant under controlled conditions by a Class A/B contractor within a planned control program. | No |
KENC | Kensington Campus | K15 | Old Main | LG | LG42 | - | Floor Covering | Vinyl Tiles (black colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | LG | LG42 | - | Floor Covering | Bitumen Adhesive (attached to sample J123597-KCS-K15-04A) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | LG | LG06D | - | Air Conditioning Ductwork Heater Bank | Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | J12 | Newton | 2 | - | Exterior, Roof Area (accessed via Room 2Q7) | Roof Covering | Bituminous membrane | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | J12 | Newton | 1 | 1Q7 | North Wall | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | J12 | Newton | G | G14 | Mezzanine Area | Floor Covering | Vinyl Tiles (Beige Colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | J12 | Newton | G | G08 | - | Floor Covering | Vinyl Tiles (Cream Colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 2Q1 | Electrical Cupboard | HV Electrical Cable | Bituminous Wrap Material | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F25 | Samuels | G | - | Exterior, West | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 610 | - | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 17 | RQ02 | Eastern Roof Section | Roof | Bituminous Membrane | Negative | - | - | - | RM Watson advised that no asbestos containing membrane was present during the replacement of the membrane in late 2018 to early 2019. | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 15Q5 | West | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1617 | - | Floor Covering (under carpet) | Vinyl Floor Tiles (beige colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | 108 | - | Floor Covering | Vinyl Floor Tiles (pink & grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | 02 | 201 | South East | Window Frames | Sealant Mastic | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F13 | Science Theatre | 1 | 1Q7 | Throughout | Floor | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F12 | Dalton | G | G1 | North-East | Wall Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F12 | Dalton | G | G1 | East and West | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F12 | Dalton | G | GQ3 | Façade | Expansion Joints | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F12 | Dalton | 01 | 1Q4 | - | Ceiling | Sprayed Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F12 | Dalton | 02 | 2Q1 | - | Ceiling / Soffit | Sprayed Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F12 | Dalton | 02 | 2Q8 | Male Toilet | Shower Cubicle Partition | Compressed Fibre Cement Sheet | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E4 | Squarehouse | R | RQ3 | Exterior | Roof Covering | Membrane | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E4 | Squarehouse | R | R1 | Plant Room, Base of Exhaust Fan | Insulation Blocks | Fire Rating - Vermiculite insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | - | Open Courtyard, NE Store | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG04 | Cleaners Room | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G14 | Robert Webster | 2 | 291 | Electrical Cupboard | Electrical Switch Board | Electrical Backing Board | Suspected Positive | - | - | - | Item Removed 30/12/2013. Refer to NAA Clearance Certificate C107859:J124201 | Yes |
KENC | Kensington Campus | E12 | UNSW Business School | G | - | East Wing Corridor Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E12 | UNSw Business School | G | - | ASB Flip Classrooms | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D23 | Mathews Theatres | 02 | 201A | North | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D23 | Mathews Theatres | 02 | 201A | North, Vertical, Floor to Ceiling Panelling | Wall | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D16 | Goldstein Hall | 02 | M2Q01 | Exterior, Roof Plant Area | Roof Covering | Membrane | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D16 | Goldstein Hall | 02 | 207 | North-West | Services Riser Panelling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D14 | UNSW Hall | G | BG88 | Exterior, West Side | Infill Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D14 | UNSW Hall | G | GQ1 | East End of Corridor | Fire Door (tagged 'Fire Control, 198_') | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D14 | UNSW Hall | G | BG94A | North and West | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C25 | Lowy Cancer Research Centre | R | RQ2 | Plant Room, Ceiling | Structural Framework | Sprayed Insulation (Vermiculite) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C24 | Clancy Auditorium | 01 | 104 | - | Floor Covering | Vinyl Tiles (red colour) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | G23 | SIRF | - | - | Throughout Building | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | G23 | SIRF | 1 | 101 | Switch Room | Fire Door (tagged 'Bismac - Manufactured 20--') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | G23 | SIRF | 1 | 101 | Switch Room | Inside Main Switchboard Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | G23 | SIRF | 2 | 2Q8 | Fire Stairs | Fire Door (tagged 'Melbourne Fire Doors - Installed 2011') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | G23 | SIRF | 2 | 201 | Roof | Inside Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | G23 | SIRF | 2 | 201 | Roof | Roof Covering | Membrane Covering | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | LG5 | Above Ceiling Tiles | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | LG | LGQ9 | Throughout | Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C20 | Morven Brown | G | G12 | Under Carpet | Floor Covering | Vinyl Floor Tiles (white colour) | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | G2CP | Western Campus Car Park | G | - | Exterior Throughout including Roadways, Gardens, Footpaths | No asbestos materials were identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C15 | White House | 01 | - | Balcony, South | Flooring | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C15 | White House | G | GQ3 | Throughout | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | - | Squash Courts (B7), Exterior, East | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | - | Pool (B4), Exterior, North West, Mural | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | - | Pool (B4), Exterior, Southern Emergency Exit | High Level Infill Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | - | Pool (B4), Exterior, North East Storage Shed (Plant Enclosure) | Wall Cladding | Compressed Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | P09 | Pool (B4), South East | Access Hatch | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | B21 | Repository | G | G01 | Perimeter, Top of Walls | Expansion Joints | Bituminous Mastic Sealant | Negative | - | - | - | - | N/A |
FSH | Hay Field Station | HFS6 | Hay Field Station Quarantine Shed | G | G01A & G01B | Throughout | Floor Covering | Vinyl Tiles (off white colour) | Negative | - | - | - | - | N/A |
FSH | Hay Field Station | HFS6 | Hay Field Station Quarantine Shed | G | G01 | Eastern End, Outside Room G01B | Flooring | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSH | Hay Field Station | HFS6 | Hay Field Station Quarantine Shed | G | G01 | Eastern End, Outside Room G01B | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | - | Kitchen | Floor Covering | Vinyl Tiles (beige colour) | Negative | - | - | - | - | N/A |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | - | Far SW Corner Room, Toilet (former uncovered awning) | Floor Covering | Vinyl Tiles (cream colour) | Negative | - | - | - | - | N/A |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | - | Exterior, Sub-Floor Space | On Top of Piers, Packing | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | G01 | NW Corner Room, | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | G2CP | Western Campus Car Park | G | - | Exterior, South East | Drain | Moulded Compressed Fibre Material | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | H22 | Valentine Annexe | G | G10A | East & West | Fire Doors (tagged 'Bismac, 2014' & Fire Systems Engineering, 199_') | Core Insulation | Suspected Negative | - | - | - | - | Yes |
Kenc | Kensington Campus | H22 | Valentine Annexe | G | G10 | North West | Furnace | Fibre Cement Sheeting | - | - | - | - | Item Removed 15/6/2007 by Cardinal Project Services. Refer to NAA Clearance Certificate (Ref SU0013:57544). | Yes |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | G | G10 | Female Bathroom | Wall Linings | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG4 | Fowlers Gap Cottage 5 | G | - | Exterior, All Sides | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG15 | Fowlers Gap Cottage 1 | G | - | Exterior, Verandah, North, East and West Sides | Low Level Infill Wall Panelling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | H22 | Valentine Annexe | G | G10 | North West | Furnace | Rope Seal | - | - | - | - | Item Removed 15/6/2007 by Cardinal Project Services. Refer to NAA Clearance Certificate (Ref SU0013:57544). | Yes |
FSFG | Fowlers Gap Field Station | FG18 | Fowlers Gap Cottage 4 | G | - | Exterior, East Side | Low Level Infill Wall Panelling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | G08 | Main Kitchen Adjacent Meals Room | Floor Covering | Sheet Vinyl | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG13 | Fowlers Gap Shearers Quarters | G | - | Exterior, East Entrance | Flooring | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | H22 | Valentine Annexe | G | G10 | Accelerated Weathering Facility | Electrical Switch Board | Electrical Backing Board | - | - | - | - | Item Removed. No removal documentation provided. | Yes |
Kenc | Kensington Campus | H22 | Valentine Annexe | G | G10 | Distribution Board DBL1, Cupboard | Electrical Switch Board | Electrical Backing Board | - | - | - | - | Item Removed. No removal documentation provided. | Yes |
COFA | Paddington Campus | CFAG | Block G | G | GG14A | South, East & West | Wall Linings | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | 01 | F1Q2A | Electrical Cupboard | Insulation Block | Vermiculite Material | Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 01 | 118B | Plant Room | Floor Covering | Vinyl Tiles (grey colour) | Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC4 | Building CC4 | G | G06 | Cleaner's Store, East | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC3 | Building CC3 | G | G03 | Main Switch Room, West | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC3 | Building CC3 | G | G03 | Main Switch Room, West | Wall Penetration | Mastic Sealant | Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC2 | Building CC2 | G | G02A | North | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | BS30 | 30 Botany Street | G | G03 | - | Floor Covering | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | BS30 | 30 Botany Street | G | - | Exterior, Rear, West | Wall Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | BS30 | 30 Botany Street | G | - | Exterior, South-East | Awning | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | BS26 | 26 Botany Street | G | - | Exterior | Gable | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | BS26 | 26 Botany Street | G | 10 | - | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | BS22 | Tiggers Place | G | G06 | - | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | BS22 | Tiggers Place | G | G21 | Northern Side of Site, Shed | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | BS22 | Tiggers Place | G | - | External | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | AS22 | 22 Arthur Street | G | - | Exterior, Rear Accommodation, North, Below Windows | Infill Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | AS20 | 20 Arthur Street | G | - | Exterior, West, Surrounding Air Conditioning Unit | Infill Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | AS14 | 14 Arthur Street | G | - | Exterior, South & East Sides | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | AS12 | 12 Arthur Street | G | - | Exterior, West | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | AS10 | 10 Arthur Street | G | GQ4 | Exterior, Garage, South | Infill Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | AS10 | 10 Arthur Street | G | - | Exterior, Rear, South | Wall Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | AS10 | 10 Arthur Street | G | G08 | South | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | AS4 | 4 Arthur Street | G | - | Exterior, Driveway | Expansion Joint | Bituminous Material | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | AS4 | 4 Arthur Street | G | - | Exterior, West | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | AS4 | 4 Arthur Street | G | - | Exterior, Front Entrance | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | A27 | Golf House | G | - | Exterior, Rear, West | Window Frames | Putty | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | A27 | Golf House | G | - | Exterior, South, Entrance Area | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | HS46 | 46 High Street | 02 | - | Unit 13, Lounge Room | Ceiling | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | HS46 | 46 High Street | G | - | Rear Laundry | Floor | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | - | Exterior, South of Room 140 | Roof Covering | Bituminous Membrane | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | - | Exterior, East Alcove | Ceiling | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K14 | Physics Theatre | G | G25 | Ceiling Space | Steel Beams | Sprayed Insulation (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | LG | LG01 | Ceiling Space, Beam | Beam | Decorative Coating (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | G | G42 | Table Top to PARR Reactor | Work Bench | Compressed Fibre Cement Sheet | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 01 | 141 | Fire Hydrant | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C6 | International House | G | G99-1 | Fire Place Room | Windows | Caulking | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 16 | 1601 | Goods Lift Motor Room | Lift Motor No.24 | Brake Pads | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 4 | 4Q14 | Fire House Reel Cupboard Adjacent Fire Stairs (4Q14) | Stored Blocks | Insulation (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 18 | 1803 | Lift Motor Room | Lift Motor 19 | Brake Pad Linings | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 18 | 1803 | Lift Motor Room | Lift Motor 18 | Brake Pad Linings | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 18 | 1803 | Lift Motor Room | Lift Motor 17 | Brake Pad Linings | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 18 | 1803 | Lift Motor Room | Lift Motor 16 | Brake Pad Linings | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | H22 | Valentine Annexe | G | G10 | Distribution Board DBL1, Cupboard | Fire Door | Core Insulation | - | - | - | - | Item Removed. No removal documentation provided. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | G | - | Former Kitchen Areas, Ceiling Space | Sprayed Insulation to Ceiling | Vermiculite | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG4 | Fowlers Gap Cottage 5 | G | - | Exterior, All Sides | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | C299 | Throughout | Cubicle Partitions | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | H22 | Valentine Annexe | G | G10 | Distribution Board DBL6 | Electrical Switch Board | Electrical Backing Board | - | - | - | - | Item Removed. No removal documentation provided. | Yes |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 05 | 5Q2 | Throughout | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC1 | Cliffbrook House | G | - | Interior | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC1 | Cliffbrook House | 1 | - | Interior | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC2 | Building CC2 | G | - | Interior | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC3 | Building CC3 | G | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
COFA | Paddington Campus | CFAA | Block A | B-1 | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
COFA | Paddington Campus | CFAC | Block C | SB-2 | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
COFA | Paddington Campus | CFAD | Block D | B-3 | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
COFA | Paddington Campus | CFAD | Block D | B | - | Toilets | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAD | Block D | G | - | Toilets | No asbestos materials were identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAD | Block D | 01 | - | Toilets | No asbestos materials were identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAD | Block D | 02 | - | Toilets | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | B | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | G | - | Communications Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | G | - | Mechanical Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | G | - | Toilets | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | 01 | - | Communications Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | 01 | - | Mechanical Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | 01 | - | Toilets | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | 02 | - | Communications Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | 02 | - | Mechanical Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | 02 | - | Toilets | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | 03 | - | Communications Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | 03 | - | Mechanical Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | 03 | - | Toilets | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | 04 | - | Communications Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | 04 | - | Mechanical Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAF | Block F | 04 | - | Toilets | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAG | Block G | B-1 | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G10 | South East | Soil Drying Oven - Door Seal | Rope Insulation | - | - | - | - | Oven door seal removed in March 2008. Refer to NAA Clearance Certificate (Ref SU0013:55783). | Yes |
Kenc | Kensington Campus | H22 | Valentine Annexe | G | G10 | West Adjacent Room G11C | Electrical Switch Board | Electrical Backing Board | - | - | - | - | Item Removed. No removal documentation provided. | Yes |
DPFS | David Phillips Field | DP4 | Grounds Depot | G | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG10 | Fowlers Gap Nissan Hut | G | - | - | No asbestos materials identified | - | Negative | - | - | - | Demolished | N/A |
FSFG | Fowlers Gap Field Station | FG16 | Fowlers Gap Kangaroo Shed | G | - | - | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG17 | Fowlers Gap Aviary | G | - | - | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG22 | Fowlers Gap Greenhouse | G | - | - | No asbestos materials identified within Greenhouse Structure | - | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG28 | Fowlers Gap Garage for Cottage 2 | G | - | Triple Garage | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG29 | Fowlers Gap Ochre House | G | - | - | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG30 | Fowlers Gap Silcrete Lodge | G | - | - | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | FG6 | Fowlers Gap Machinery Shed | G | - | - | No asbestos materials identified | - | Negative | - | - | - | Note: New Lathe Shed. Old Lathe Shed demolished 2014. | N/A |
FSFG | Fowlers Gap Field Station | FG8 | Fowlers Gap Machine Shop | G | G01 | - | No asbestos materials identified | - | - | - | - | - | N/A | |
FSFG | Fowlers Gap Field Station | FG9 | Fowlers Gap Fuel Store | G | - | - | No asbestos materials identified | - | - | - | - | - | No | |
Kenc | Kensington Campus | H22 | Valentine Annexe | G | G13 | Distribution Board DBL2, Cupboard | Electrical Switch Board | Electrical Backing Board | - | - | - | - | Item Removed. No removal documentation provided. | Yes |
FSSL | Smiths Lake Field Station | SL11 | Wood Shed | G | G01 | Throughout | No asbestos materials Identified | - | - | - | - | - | - | N/A |
FSSL | Smiths Lake Field Station | SL12 | Rain Water Pump Shed | G | G01 | Throughout | No asbestos materials Identified | - | - | - | - | - | - | N/A |
FSSL | Smiths Lake Field Station | SL13 | Ablutions Pump Shed | G | G01 | Throughout | No asbestos materials Identified | - | - | - | - | - | - | N/A |
Kenc | Kensington Campus | H22 | Valentine Annexe | G | G14 | Distribution Board DBL5, Cupboard | Electrical Switch Board | Electrical Backing Board | - | - | - | - | Item Removed. No removal documentation provided. | Yes |
FSSL | Smiths Lake Field Station | SL3 | Smiths Lake Accommodation | G | - | Throughout | No asbestos materials Identified | - | - | - | - | - | - | N/A |
FSSL | Smiths Lake Field Station | SL5 | Smiths Lake Cooking Shelter | G | - | Throughout | No asbestos materials Identified | - | - | - | - | - | - | N/A |
Kenc | Kensington Campus | H22 | Valentine Annexe | G | G17A | Distribution Board DBL3 & DBL4 | Electrical Switch Board | Electrical Backing Board | - | - | - | - | Item Removed. No removal documentation provided. | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G20C | Now G14A | Fume Cupboard | Fibre Cement Sheeting | - | - | - | - | Item Removed. No removal documentation provided. | Yes |
FSW | Wellington Field Station | WFS1A | Wellington Field Station Shed | G | G01 | Throughout | No asbestos materials Identified | - | Negative | - | - | - | - | N/A |
FSW | Wellington Field Station | WFS1B | Wellington Field Station Garage | G | G01 | Throughout | No asbestos materials Identified | - | Negative | - | - | - | - | N/A |
FSW | Wellington Field Station | WFS23 | Wellington Field Station Administration | G | - | Throughout | No asbestos materials Identified | - | Negative | - | - | - | - | N/A |
FSW | Wellington Field Station | WFS3 | Wellington Field Station Machinery Shed | G | G01 & G02 | Throughout | No asbestos materials Identified | - | Negative | - | - | - | - | N/A |
FSW | Wellington Field Station | WFS4 | Wellington Field Station Hay Shed | G | G01 | Throughout | No asbestos materials Identified | - | Negative | - | - | - | - | N/A |
FSW | Wellington Field Station | WFS5 | Wellington Field Station Cattle Shed | G | G01 | Throughout | No asbestos materials Identified | - | Negative | - | - | - | - | N/A |
FSW | Wellington Field Station | WFS8 | Wellington Field Station Storage Shed | G | G01 | Throughout | No asbestos materials Identified | - | Negative | - | - | - | - | N/A |
FSH | Hay Field Station | HFS1 | Hay Field Station Shed | G | G01 | Throughout | No asbestos materials Identified | - | Negative | - | - | - | - | N/A |
FSH | Hay Field Station | HFS2 | Hay Field Station Workshop | G | - | Throughout | No asbestos materials Identified in Workshop | - | Negative | - | - | - | - | N/A |
FSH | Hay Field Station | HFS3 | Hay Field Station Machinery Shed | G | G01 | Throughout | No asbestos materials Identified in Machinery Shed | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | H22 | Valentine Annexe | G | G21 | Central, Oven | Door Seal | Rope Insulation | - | - | - | - | Item Removed 15/6/2007 by Cardinal Project Services. Refer to NAA Clearance Certificate (Ref SU0013:57544). | Yes |
Kenc | Kensington Campus | H22 | Valentine Annexe | G | G21 | Entrance | Fire Door | Core Insulation | - | - | - | - | Item Removed 11/4/2015 by ATS. Refer to Greencap-NAA Clearance Certificate Report (Ref C107266:J131980). | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G20 | - | Floor Covering | Vinyl Tiles (Grey Colour) | Removed -Positive | - | - | - | Item Removed. No removal documentation provided. | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G20A | - | Floor Covering | Vinyl Tiles (Grey Colour) | Removed -Positive | - | - | - | Item Removed. No removal documentation provided. | Yes |
KENC | Kensington Campus | B14D | Fig Tree Theatre | G | - | Roof Space | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | B16 | Colombo House | LG-7 | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | B16 | Colombo House | LG-7 | - | Communications Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | B17 | Goldstein College | LG-6 | - | Throughout | No asbestos materials identified or suspected | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | B17 | Goldstein College | LG | LGQ13 | Switch Room | No asbestos materials identified or suspected | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | B17 | Goldstein College | LG-5 | - | Communications Cupboards | No asbestos materials identified or suspected | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | B18 | Fig Tree Hall | G-6 | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | B18 | Fig Tree Hall | G-5 | - | Communications Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G14A | - | Floor Covering | Vinyl Tiles (Blue Colour) | Removed -Positive | - | - | - | Item Removed. No removal documentation provided. | Yes |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | P04 | Pool (B4), Main Switch Room | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B8 | University Terraces | B-7 | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B8 | University Terraces | B-7 | - | Communications Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B8 | University Terraces | B-7 | - | Electrical Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B8 | University Terraces | B-7 | - | Accommodation Rooms | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B8 | University Terraces | B-7 | - | Bathrooms & Toilets | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B8 | University Terraces | B | - | Mechanical Plant Rooms | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C15 | White House | - | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G20 | - | Floor Covering | Vinyl Tiles (Blue Colour) | Removed -Positive | - | - | - | Item Removed. No removal documentation provided. | Yes |
Kenc | Kensington Campus | C25 | Lowy Cancer Research Centre | B-5 | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C25 | Lowy Cancer Research Centre | B-5 | - | Communications Cupboards Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | C25 | Lowy Cancer Research Centre | B-5 | - | Hydraulic Risers Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C27 | Wallace Wurth | LG-7 | - | Communications Cupboards Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C27 | Wallace Wurth | LG-7 | - | Hydraulic Risers Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C27 | Wallace Wurth | LG-7 | - | Plant Rooms | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D17 | Basser College | B-7 | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D17 | Basser College | LG-6 | - | Throughout, Electrical Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D17 | Basser College | LG-6 | - | Throughout, Communications Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G20A | - | Floor Covering | Vinyl Tiles (Blue Colour) | Removed -Positive | - | - | - | Item Removed. No removal documentation provided. | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G10 | East Adjacent Room G14 | Fume Cupboard | Fibre Cement Sheeting | Removed -Positive | - | - | - | Item Removed. No removal documentation provided. | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G10 | South East | Soil Drying Oven | Internal Rope Insulation | Removed -Positive | - | - | - | Item Removed. No removal documentation provided. | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | 1 | 117 | Store Room, Under New Vinyl Sheeting | On Concrete Floor | Adhesive | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G19A | East Side | Fume Hood | Fibre Cement Sheeting | Positive (Chrysotile, Amosite & Crocidolite) | Non-friable | Low | P3 | Damaged section has been sealed during the 2019 inspection. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H22 | Valentine Annexe | R | R1 | Roof, Plant Room (access via Room 1Q5) | Compressor Manifold | Gasket | Removed -Positive (Chrysotile) | - | - | - | Item Removed. No removal documentation provided | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G14 | East, Above Entrance | Supply Fan / Duct Work Joints | Mastc Sealant | Removed -Positive (Chrysotile) | - | - | - | Item Removed by Pure Contracting. Refer to RiskTech Compliance Clearance Certifcate Report dated 15 August 2022. | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G13 | - | Floor Covering | Adhesive attached to Grey Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E12 | UNSW Business School | G-6 | - | Communications Cupboards Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G13B | - | Floor Covering | Adhesive attached to Grey Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | LG-2 | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E15 | Quadrangle | G | - | Communications Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E15 | Quadrangle | 01 | - | Communications Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E15 | Quadrangle | 02 | - | Communications Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E15 | Quadrangle | 03 | - | Communications Cupboards | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G13C | - | Floor Covering | Adhesive attached to Grey Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | - | Open Courtyard, North Side, Entry Area to Foodcourt | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E26 | Biological Sciences South | LG - Roof | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E26 | Biological Sciences South | LG - 7 | - | Electrical Cupboards Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E26 | Biological Sciences South | LG - 7 | - | Service Risers Cupboards & Plant Rooms | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E6 | Roundhouse | G-1 | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 02 | 2Q6 | - | Floor Covering | Vinyl Tiles (dark Blue) | Negative (Removed) | - | - | - | Item Removed 29/4/2019 by Pure Contracting. Refer to RiskTech Clearance Certificate dated 29/4/2019. | Yes |
MANV | Manly Vale | MV1 | Laboratory 1 | G | G02 | - | Floor Covering | Vinyl Tiles (black colour) | Negative - Removed | - | - | - | - | Yes |
KENC | Kensington Campus | E6 | Roundhouse | R | - | Throughout | Loose Material | Insulation | Negative - Removed | - | - | - | - | Yes |
KENC | Kensington Campus | E6 | Roundhouse | R | - | Throughout | Loose Material | Insulation | Negative - Removed | - | - | - | - | Yes |
KENC | Kensington Campus | E6 | Roundhouse | R | - | Throughout | Loose Material | Insulation | Negative - Removed | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | 02 | C201 | Throughout | Floor Covering | Adhesive | Negative (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | G | CG01 | Throughout | Ceiling | Vermiculite | Negative (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | G | CGQ3 | Throughout | Floor Covering | Vinyl Tiles | Negative (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | Block C | 02 | C2Q3 | Throughout | Floor Covering | Adhesive | Negative (Removed) | - | - | - | - | Yes |
KENC | Kensington Campus | E6 | Roundhouse | G | Former Room G04A | Throughout | Wall Lining | Fibre Cement Sheeting | Negative - Removed | - | - | - | - | Yes |
KENC | Kensington Campus | E6 | Roundhouse | 01 | Fomer Room 115 | Throughout | Floor Underlay | Fibrous-Backed Sheet Vinyl | Negative - Removed | - | - | - | - | Yes |
KENC | Kensington Campus | E6 | Roundhouse | 01 | Fomer Room 115 | Under Purple Carpet | Floor Covering | Vinyl Tiles (black colour) | Negative - Removed | - | - | - | - | Yes |
KENC | Kensington Campus | E6 | Roundhouse | R | - | Throughout, Ceiling | Sprayed Insulation | Vermiculite | Negative - Removed | - | - | - | - | Yes |
KENC | Kensington Campus | E6 | Roundhouse | 01 | - | Exterior, Surrounding | Verandah Railing Capping | Fibre Cement Sheeting | Negative - Removed | - | - | - | - | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LGQ1 | (Room no longer noted on plans) | Floor Covering | Vinyl Tiles (green colour) | Positive - Removed | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LGQ1 | (Room no longer noted on plans) | Floor Covering | Adhesive | Positive - Removed | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LGQ2 | Substation No.9 | Electrical Cupboard | Electrical Backing Board | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LGQ12 | Fire Stairwell | Fire Door | Core Insulation | - | - | - | - | Item removed by Pure Contracting on 10/11/2015 - Greencap-NAA Clearance Certificate (Ref: C107859:J141449) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LGQ16 | - | Heater Block Units & Debris | Fibre Cement Sheeting | - | - | - | - | Item removed by Cardinal Project Services on 30/6/2007 - NAA Clearance Certificate (Ref: SU0013:57843) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LG11 | - | Cabinet | Insulation Debris | - | - | - | - | Item removed by Cardinal Project Services on 17/6/2007 - NAA Clearance Certificate (Ref: SU0013:57548) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LG12 & LG12A | - | - | Insulation Debris | - | - | - | - | Item removed by Cardinal Project Services on 17/6/2007 - NAA Clearance Certificate (Ref: SU0013:56780) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LG12 & LG12A | Lathe Machine | Machine Components | Woven Rope & Fibre Cement Sheeting | - | - | - | - | Item removed by Cardinal Project Services on 17/6/2007 - NAA Clearance Certificate (Ref: SU0013:56780) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | G | GQ1 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | G | GQ1 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | G | GQ2 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | G | GQ2 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | G | GQ4 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | G | GQ4 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | M | MQ1 | (Previously Rooms MQ9, M15 & M16) | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | M | MQ2 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | M | M02 | West Exit | Fire Door | Core Insulation | - | - | - | - | Item removed by Pure Contracting on 10/11/2015. Greencap-NAA Clearance Certificate (C107859:J141449). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | M | M02B | Entrance | Fire Door | Core Insulation | - | - | - | - | Item removed by Pure Contracting on 7/11/2015. Greencap-NAA Clearance Certificate (C107859:J141449). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | M | M02B | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Pure Contracting on 7/11/2015. Greencap-NAA Clearance Certificate (C107859:J141449). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | M | M03 | - | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | M | M11 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | M | M17 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 1Q2 | (Previously Rooms 114, 115, 116 & 117) | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 1Q2 | (Previously Room 117) | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 1Q3 | Fire Stairwell | Fire Door | Core Insulation | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 101 | - | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 101 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting Between 16-23 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 101 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting Between 16-23 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 101A | Throughout | Floor Covering | Vinyl Tiles (olive green) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 16-23 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 101A | Throughout | Floor Covering | Adhesive (attached to vinyl tile) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 16-23 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 102 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting Between 24-29 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 102 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting Between 24-29 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 102A | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting Between 24-29 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 102A | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting Between 24-29 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 102B | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting Between 24-29 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 102B | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting Between 24-29 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 102C | Throughout | Floor Covering | Vinyl Tiles (olive green) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 24-29 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 102C | Throughout | Floor Covering | Adhesive (attached to vinyl tile) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 24-29 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 103 | Throughout | Floor Covering | Vinyl Tiles (olive green) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 24-29 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 103 | Throughout | Floor Covering | Adhesive (attached to vinyl tile) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 24-29 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 103A | Throughout | Floor Covering | Vinyl Tiles (olive green) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 24-29 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 103A | Throughout | Floor Covering | Adhesive (attached to vinyl tile) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 24-29 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 103B | Throughout | Floor Covering | Vinyl Tiles (olive green) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 24-29 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 103B | Throughout | Floor Covering | Adhesive (attached to vinyl tile) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 24-29 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 103C | Throughout | Floor Covering | Vinyl Tiles (olive green) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 24-29 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 103C | Throughout | Floor Covering | Adhesive (attached to vinyl tile) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 24-29 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 104 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 108 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 109 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 110 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 111 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 112 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 113A | (Previously Room 117) | Fire Door | Core Insulation | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 113A | (Previously Room 118) | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 113A | (Previously Rooms 1Q2, 118, 118A & B) | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 113B | (Previously Room 118 & 118C) | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 2Q3 | Fire Stairwell | Fire Door | Core Insulation | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 2Q5 | Fire Stairwell | Fire Door | Core Insulation | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 201 | - | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 201 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting Between 29/4/2008 & 9/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 201 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting Between 29/4/2008 & 9/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 201A | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting Between 29/4/2008 & 9/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 201A | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting Between 29/4/2008 & 9/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 201B | Throughout | Floor Covering | Vinyl Tiles (olive green) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 29/4/2008 & 9/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 201B | Throughout | Floor Covering | Adhesive (attached to vinyl tile) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 29/4/2008 & 9/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 201C | Throughout | Floor Covering | Vinyl Tiles (olive green) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 29/4/2008 & 9/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 201C | Throughout | Floor Covering | Adhesive (attached to vinyl tile) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 29/4/2008 & 9/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 201E | Throughout | Floor Covering | Vinyl Tiles (olive green) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 29/4/2008 & 9/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 201E | Throughout | Floor Covering | Adhesive (attached to vinyl tile) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 29/4/2008 & 9/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 201F | Throughout | Floor Covering | Vinyl Tiles (olive green) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 29/4/2008 & 9/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 201F | Throughout | Floor Covering | Adhesive (attached to vinyl tile) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 29/4/2008 & 9/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 201G | Throughout | Floor Covering | Vinyl Tiles (olive green) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 29/4/2008 & 9/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 201G | Throughout | Floor Covering | Adhesive (attached to vinyl tile) | Positive - Removed | - | - | - | Item removed by Rhino Contracting Between 29/4/2008 & 9/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 202 | - | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 202 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting Between 29/4/2008 & 9/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 202 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting Between 29/4/2008 & 9/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 202A | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting Between 29/4/2008 & 9/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 202A | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting Between 29/4/2008 & 9/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 204 | Cleaners Room | Fire Door | Core Insulation | - | - | - | - | Item removed by Pure Contracting on 10/11/2015. Greencap-NAA Clearance Certificate (C107859:J141449). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 204 | Cleaners Room | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 204 | Cleaners Room | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 206 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 208 | (Previously Rooms 207, 209 & 210) | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting Between 10/5/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 212 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 213 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 214 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 215 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 216 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 217 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 218 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 219 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 220 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 223 | Throughout | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting Between 24-29 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 223 | Throughout | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting Between 24-29 April 2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 3Q2 | Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item removed by Pure Contracting on 27/12/2013. NAA Clearance Certificate (C107859:J124201) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 3Q3 | Fire Stairwell | Fire Door | Core Insulation | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 3Q5 | Fire Stairwell | Fire Door | Core Insulation | - | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 306 | Cleaners Room | Fire Door | Core Insulation | - | - | - | - | Item Removed: 23/9/2014. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 310 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 311 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting on 1/9/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 311 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting on 1/9/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 315 | Entrance | Fire Door | Core Insulation | - | - | - | - | Item removed by Pure Contracting on 28/11/2015. Greencap-NAA Clearance Certificate (C107859:J141449). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 315 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Pure Contracting on 10/3/2012. NAA Clearance Certificate (C107946:J105057) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 317 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting on 1/9/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 317 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting on 1/9/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 318 | Entrance | Fire Door | Core Insulation | - | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 318 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting on 1/9/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 318 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting on 1/9/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 319 | Entrance | Fire Door | Core Insulation | Positive - Removed | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 322 | Entrance | Fire Door | Core Insulation | - | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 323 | Entry Foyer & Under New Flooring | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting on 1/9/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 324 | Entry Foyer & Under New Flooring | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting on 1/9/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 4Q2 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 401 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 402 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Pure Contracting on 18/8/2012. NAA Clearance Certificate (C107946:J105057). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 402 | Under New Flooring | Floor Covering | Adhesive | - | - | - | - | Item removed by Pure Contracting on 18/8/2012. NAA Clearance Certificate (C107946:J105057). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 407 | Cleaners Room | Fire Door | Core Insulation | - | - | - | - | Item removed by Pure Contracting on 7/11/2015. Greencap-NAA Clearance Certificate (C107859:J141449). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 408 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Pure Contracting on 1/6/2012. NAA Clearance Certificate (C107946: J105057). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 409 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 410 | (Previously Rooms 410, 411) | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Pure Contracting on 9/6/2012. NAA Clearance Certificate (C107946:J111637) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 411 | (Previously Rooms 412, 413) | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Pure Contracting on 9/6/2012. NAA Clearance Certificate (C107946:J111637) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 412 | (Previously Rooms 414, 415/416) | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Pure Contracting on 9/6/2012. NAA Clearance Certificate (C107946:J111637) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 413 | (Previously Rooms 417, 418, 419) | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed in Room 418 by Cardinal Project Services on 23/12/2008. NAA Clearance Certificate (SU0013:70685) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 5Q2 | Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item Removed 27/12/2013. NAA Clearance Certificate (C107859:J124201) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 504 | Cleaners Room | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 504 | Cleaners Room | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 504 | Cleaners Room | Fire Door | Core Insulation | - | - | - | - | Item removed by Pure Contracting on 10/11/2015. Greencap-NAA Clearance Certificate (C107859:J141449). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 506 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Pure Contracting on 18/8/2012. NAA Clearance Certificate (C107946:J105057). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 506 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Pure Contracting on 18/8/2012. NAA Clearance Certificate (C107946:J105057). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 509 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Pure Contracting on 2/11/2013. NAA Clearance Certificate (C107859:J123120). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 509 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Pure Contracting on 2/11/2013. NAA Clearance Certificate (C107859:J123120). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 512 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Pure Contracting on 2/11/2013. NAA Clearance Certificate (C107859:J123120). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 512 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Pure Contracting on 2/11/2013. NAA Clearance Certificate (C107859:J123120). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 513 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Pure Contracting on 2/11/2013. NAA Clearance Certificate (C107859:J123120). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 513 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Pure Contracting on 2/11/2013. NAA Clearance Certificate (C107859:J123120). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 514 | North Section of Room (previously Room 514A) | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 601 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 601A | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 602 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 603 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 603A | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 603B | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 605 | Cleaners Room | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 605 | Cleaners Room | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 605 | Cleaners Room | Fire Door | Core Insulation | - | - | - | - | Item Removed 23/9/2014. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 605 | Cleaners Room | Shelving, Vinyl Sheet Coverings | Millboard (Backing on Vinyl Sheeting) | - | - | - | - | Item removed by Pure Contracting on 21/3/2015. Greencap-NAA Clearance Certificate (C107859:J132192) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 614 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting on 1/9/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 614 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting on 1/9/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 614A | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting on 1/9/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 614A | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting on 1/9/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 614C | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting on 1/9/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 614C | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting on 1/9/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 7Q3 | Fire Stairwell | Fire Door | Core Insulation | - | - | - | - | Item removed by Pure Contracting on 28/11/2015. Greencap-NAA Clearance Certificate (C107859:J141449). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 7Q5 | Fire Stairwell | Fire Door | Core Insulation | - | - | - | - | Item removed by Pure Contracting on 28/11/2015. Greencap-NAA Clearance Certificate (C107859:J141449). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 701 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 701A | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 701B | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 701C | - | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 701C | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 703 | Cleaners Room | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 703 | Cleaners Room | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 703 | Cleaners Room | Fire Door | Core Insulation | - | - | - | - | Item Removed: 23/9/2014. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 704 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Cardinal Project Services on 1/2/2008. NAA Clearance Certificate (SU0013:55783). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 704 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Cardinal Project Services on 1/2/2008. NAA Clearance Certificate (SU0013:55783). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 705 | - | - | Floor - Vinyl Tiles - Olive green | - | - | - | - | Item removed by Cardinal Project Services on 1/2/2008. NAA Clearance Certificate (SU0013:55783). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 705 | - | - | Floor - Adhesive - Attached to vinyl tile | - | - | - | - | Item removed by Cardinal Project Services on 1/2/2008. NAA Clearance Certificate (SU0013:55783). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 8Q3 | Fire Stairwell | Fire Door | Core Insulation | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 8Q5 | Fire Stairwell | Fire Door | Core Insulation | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 801 | Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 801 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting on 1/10/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 801/802 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive - Removed | - | - | - | Item removed by Rhino Contracting on 1/10/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 801A | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 801B | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting on 1/10/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 801B | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting on 1/10/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 801C | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting on 1/10/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 801C | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting on 1/10/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 801D | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 804 | Cleaners Room | Fire Door | Core Insulation | - | - | - | - | Item removed 23/9/2014. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 804 | Cleaners Room | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting on 1/10/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 804 | Cleaners Room | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting on 1/10/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 804 | Cleaners Room | Shelving, Vinyl Sheet Coverings | Millboard (Backing on Vinyl Sheeting) | - | - | - | - | Item removed by Pure Contracting on 21/3/2015. Greencap-NAA Clearance Certificate (C107859:J132192) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 813 | Entrance | Fire Door | Core Insulation | - | - | - | - | Item removed by Pure Contracting on 7/11/2015. Greencap-NAA Clearance Report (C107859:J141449). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 814 | Entrance | Fire Door | Core Insulation | - | - | - | - | Item removed by Pure Contracting on 7/11/2015. Greencap-NAA Clearance Report (C107859:J141449). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 816 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 816A | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 9Q3 | Fire Stairwell | Fire Door | Core Insulation | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 9Q5 | Fire Stairwell | Fire Door | Core Insulation | - | - | - | - | Item removed by Pure Contracting on 28/11/2015. Greencap-NAA Clearance Certificate (C107859:J141449). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 901 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Cardinal Project Services on 22/08/2011. NAA Clearance Certificate SS0263:77747) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 901 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Cardinal Project Services on 25-26/08/2011. NAA Clearance Certificate SS0263:77747) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 901A | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 902 | (Assumed to previously include Rooms 902A-C) | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting on 1/4/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 902 | (Assumed to previously include Rooms 902A-C) | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting on 1/4/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 903 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Rhino Contracting on 1/4/2008. NAA Clearance Certificate (SP0149:64856). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 903 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Rhino Contracting on 1/4/2008. NAA Clearance Certificate (SP0149:64166). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 905 | Cleaners Room | Fire Door | Core Insulation | - | - | - | - | Item removed by Pure Contracting on 7/11/2015. Greencap-NAA Clearance Certificate (C107859:J141449). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 905 | Cleaners Room | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 905 | Cleaners Room | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 905 | Cleaners Room | Shelving, Vinyl Sheet Coverings | Millboard (Backing on Vinyl Sheeting) | - | - | - | - | Item removed by Pure Contracting on 21/3/2015. Greencap-NAA Clearance Certificate (C107859:J132192) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 915 | Entrance | Fire Door | Core Insulation | - | - | - | - | Item removed by Pure Contracting on 7/11/2015. Greencap-NAA Clearance Certificate (C107859:J141449). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 916 | Entrance | Fire Door | Core Insulation | - | - | - | - | Item removed by Pure Contracting on 7/11/2015. Greencap-NAA Clearance Certificate (C107859:J141449). | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 919 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 920 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 921 | Entrance | Fire Door | Core Insulation | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 921 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 922 | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Cardinal Project Services on 1/11/2009. NAA Clearance Certificate SS0263:77747) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 922 | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Cardinal Project Services on 1/11/2009. NAA Clearance Certificate SS0263:77747) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 922A | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Cardinal Project Services on 1/11/2009. NAA Clearance Certificate SS0263:77747) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 922A | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Cardinal Project Services on 1/11/2009. NAA Clearance Certificate SS0263:77747) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 922B | - | Floor Covering | Vinyl Tiles (olive green) | - | - | - | - | Item removed by Cardinal Project Services on 1/11/2009. NAA Clearance Certificate SS0263:77747) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 922B | - | Floor Covering | Adhesive (attached to vinyl tile) | - | - | - | - | Item removed by Cardinal Project Services on 1/11/2009. NAA Clearance Certificate SS0263:77747) | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | 10Q3 | Fire Stairwell | Fire Door | Core Insulation | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | 10Q5 | Fire Stairwell | Fire Door | Core Insulation | - | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
Kenc | Kensington Campus | C6 | International House | G | G18 | Accommodation Room | Fire Door | Insulation Core | Removed - Positive (chrysotile & amosite) | - | - | - | Item Removed: Refer to Asbestos Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
Kenc | Kensington Campus | C6 | International House | G | G77A | Store | Fire Door | Insulation Core | Removed - Positive (chrysotile & amosite) | - | - | - | Item Removed: Refer to Asbestos Clearance Certificate - RiskTech dated 12 February 2019 | Yes |
Kenc | Kensington Campus | C6 | International House | G | G19 | Accommodation Room | Fire Panels Above Fire Door | Insulation Core | Removed - Positive (chrysotile & amosite) | - | - | - | Item Removed: Refer to Asbestos Clearance Certificate - RiskTech dated 05 December 2018 | Yes |
KENC | Kensington Campus | F21 | Library | 15 | 15Q5 | Plant Room, West Side, Underside of Metal Floor Access Hatch in Ceiling Space East of Main Lift Lobby on Level 14 | Fire Panels | Core Insulation | Removed - Positive (chrysotile & amosite) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 11 August 2018. | Yes |
KENC | Kensington Campus | F21 | Library | 14 | - | Former Hoist Room Adjacent Goods Lift | Fire Door (tagged 'Padde - Fire Control Pty Ltd') | Core Insulation | Removed - Positive (chrysotile & amosite) | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 14 | 1401A | Goods Lift Lobby Area, Underside of Metal Floor Access Hatch to Room 1503 (former Book Hoist Motor Room) | Fire Panels & Debris | Core Insulation | Removed - Positive (chrysotile & amosite) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 23 July 2018. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG28 | South Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Positive (Chrysotile) - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 8 April 2019. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG29 | East Side, South Wall | On Vertical Metal Plate Strip | Sealant Mastic (brown colour) | Positive (Chrysotile) - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 8 April 2019. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG29 | - | Floor Covering | Vinyl Floor Tiles (beige colour) | Positive (Chrysotile) - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 8 April 2019. | Yes |
KENC | Kensington Campus | F20 | Goodsell | LG | LG28 | - | Floor Covering | Vinyl Floor Tiles (beige colour) | Positive (Chrysotile) - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 8 April 2019. | Yes |
KENC | Kensington Campus | F21 | Library | LG | LGQ05 | Air Conditioning Plant Room Above AHU No.2 (base of return air shaft) | On Roof of Air Handling Unit | Fibrous Insulation Debris | Removed - Positive (chrysotile) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 25 February 2019 & 2 March 2020. | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G13 | - | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G13A | - | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 1 | 1Q7 | Electrical Switchboard Cupboard | Meter Board Adjacent DB-11 | Electrical Backing Board | Positive (Chrysotile) - Removed | - | - | - | Item Removed: Refer to Clearance Certificate - RiskTech dated 11 February 2017 | Yes |
Kenc | Kensington Campus | C6 | International House | 1 | 1Q2 | Electrical Switchboard Cupboard | Meter Board Adjacent DB-12 | Electrical Backing Board | Positive (Chrysotile) - Removed | - | - | - | Item Removed: Refer to Clearance Certificate - RiskTech dated 11 February 2017 | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q17 | South Roof Section | Roof | Bituminous Membrane | Removed -Positive (chrysotile) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 1 April 2019, 17 May 2019, 12 & 14 June 2019 and 5 & 12 July 2019. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q17 | West Roof Section, Above NW Fire Stairs (5Q8) | Roof | Bituminous Membrane | Removed -Positive (chrysotile) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 17 September 2017. | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G13B | - | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | G | G99 | East Corridor, Outside Room G99, Electrical Switchboard Cupboard | Inside Electrical Switchboard Cabinet | Electrical Backing Board | Removed - Positive (chrysotile) | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | G | G91 | East Corridor, Outside Room G91, Electrical Switchboard Cupboard | Inside Electrical Switchboard Cabinet | Electrical Backing Board | Removed - Positive (chrysotile) | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 2 | 2Q2 | Fire Stairs | Fire Door (tag 'Advanced Metal Door Frames, 2015') | Insulation Core | Positive (Chrysotile) - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | G | GQ3 | North Corridor, Adjacent Fire Stairs GQ2 | Fire Door (tag 'Advanced Metal Door Frames, 2015') | Insulation Core | Removed - Positive (chrysotile) | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | G | GQ22 | North Corridor, Electrical Switchboard Cupboard | Meter Board Adjacent DB-10 | Electrical Backing Board | Removed - Positive (chrysotile) | - | - | - | Item Removed: Refer to Asbestos Clearance Certificate - RiskTech dated 11 February 2017 | Yes |
Kenc | Kensington Campus | C6 | International House | G | GQ2 | Fire Stairs | Fire Door (no tag) | Insulation Core | Removed - Positive (chrysotile) | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | G | G80 | Electrical Switchboard Cupboard Outside Recreational Room | Meter Board Adjacent DB-09 | Electrical Backing Board | Removed - Positive (chrysotile) | - | - | - | Item Removed: Refer to Asbestos Clearance Certificate - RiskTech dated 11 February 2017 | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G13C | - | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 1 | 179 | Female Amenities / Toilets | Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
Kenc | Kensington Campus | C6 | International House | 1 | 187 | Male Amenities / Toilets | Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided | Yes |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G03 | Under Carpet | Floor Covering | Adhesive | Presumed 'Negative | - | - | - | - | No |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G04 | Under Carpet | Floor Covering | Adhesive | Presumed 'Negative | - | - | - | - | No |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G05 | Under Carpet | Floor Covering | Adhesive | Presumed Negative | - | - | - | - | No |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G06 | Under Carpet | Floor Covering | Adhesive | Presumed Negative | - | - | - | - | No |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G07 | Under Carpet | Floor Covering | Adhesive | Presumed Negative | - | - | - | - | No |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G08 | Under Carpet | Floor Covering | Adhesive | Presumed Negative | - | - | - | - | No |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G09 | Under Carpet | Floor Covering | Adhesive | Presumed Negative | - | - | - | - | No |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G1Q | Under Carpet | Floor Covering | Adhesive | Presumed Negative | - | - | - | - | No |
KENE | Kensington Environs | BS30 | 30 Botany Street | 1 | 114 | North-West, Low Level | Infill Panels | Fibre Cement Sheeting | Presumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | BS30 | 30 Botany Street | 1 | - | Exterior, Rear | Eaves | Fibre Cement Sheeting | Presumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | BS30 | 30 Botany Street | 1 | - | Exterior, Front, Below Windows | Infill Wall Panelling | Fibre Cement Sheeting | Presumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
COFA | Paddington Campus | CFAA | Block A | G | AGQ4 | Interior and Exterior | Wall | Fibre Cement Sheeting | Removed | - | - | - | - | Yes |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | P02E/F | Pool (B4), Throughout, Various | Wall Linings | Fibre Cement Sheeting | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | P03D/E | Pool (B4), Throughout, Various | Wall Linings | Fibre Cement Sheeting | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | P05 | Pool (B4), South & West | Wall Linings | Fibre Cement Sheeting | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 02 | 2Q4 | Stairwell | Fire Door (tagged 'Infinity, 20__') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H13 | The Red Centre | R | RQ01 | Exterior, Roof | Roof Concrete Topping | Membrane Layer | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H13 | The Red Centre | R | RQ01 | Exterior, Roof | Roof Concrete Topping | Membrane Layer | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H13 | The Red Centre | R | RQ01 | Exterior, Roof | Roof Concrete Topping | Membrane Layers | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H13 | The Red Centre | R | RQ01 | Exterior, Roof | Roof Concrete Topping | Membrane Layers | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ5 | Stairwell | Fire Doors x 2 (tagged 'Fire Control, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ11 | Stairwell | Fire Door (No Door Tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ13 | Stairwell | Fire Doors x 2 (tagged 'Fire Control, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 01 | 1Q5 | Stairwell | Fire Door (tag not legible) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1201 | - | Panel Above Door | Solid Timber | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1206 | - | Panel Above Door | Solid Timber | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 01 | 1Q6 | Fire Pump Room | Pipe Flange Joints | Ruber Gaskets | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | B | BQ15 | Entrance | Fire Door (tagged 2000) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | B | BQ20 | Entrance | Fire Door (tagged 2000) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LGQ12 | Fire Stairwell | Fire Door (tagged 'Bismac 2014') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LGQ20 | Fire Stairwell | Fire Door (tagged 'Bismac 2014') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LG10B | Entrance | Fire Door (tagged 'Titan 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LG10C | Entrance | Fire Door (tagged 'Titan 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LG10D | Entrance | Fire Door (tagged 'Titan 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | LG | LG10E | Entrance | Fire Door (tagged 'Titan 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | G | GQ15 | - | Fire Door (tagged 200_) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | G | GQ16 | - | Fire Door (tagged 200_) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | M | MQ7 | Fire Stairwell | Fire Door (tagged Titan 200_) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 1Q3 | Fire Stairwell | Fire Door (tagged 'Fire Research 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 2Q3 | Fire Stairwell | Fire Door (tagged 'Fire Research 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 2Q5 | Fire Stairwell | Fire Door (tagged Fire Research 199_) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 3Q3 | Fire Stairwell | Fire Door (tagged 'Fire Research 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 3Q5 | Fire Stairwell | Fire Door (tagged 'Fire Door Replacement 1995') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 3Q7 | Entrance | Fire Door (tagged 'Bismac 200-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 318 | Entrance | Fire Door (tagged 199_) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 318 | Entrance | Fire Door (tagged 'Bismac 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 319 | Entrance | Fire Door (tagged Bismac 200_) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 321 | Entrance | Fire Door (tagged 199_) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 4Q3 | Fire Stairwell | Fire Door (tagged 'Fire Research 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 5Q3 | Fire Stairwell | Fire Door (tagged 'Fire Research 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 5Q5 | Fire Stairwell | Fire Door (tagged 'Fire Door Replacement 1996') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 6Q3 | Fire Stairwell | Fire Door (tagged 'Fire Research 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 7Q3 | Fire Stairwell | Fire Door (tagged 'Bismac 2014') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 7Q5 | Fire Stairwell | Fire Door (tagged 'Bismac 2014') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 8Q3 | Fire Stairwell | Fire Door (tagged 'Wormald 20__') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 8Q5 | Fire Stairwell | Fire Door (tagged 'Wormald 20__') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 9Q3 | Fire Stairwell | Fire Door (tagged 'Wormald 20_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 9Q5 | Fire Stairwell | Fire Door (tagged 'Bismac 2014') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | 10Q3 | Fire Stairwell | Fire Door (tagged 'Wormald 201-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | 10Q5 | Fire Stairwell | Fire Door (tagged 'Fire Door Replacement 1996') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | LR | RQ03 | Fire Stairwell | Fire Door (tagged Bismac 2016) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | LR | R1 | Plant Room Entrance | Fire Door (tagged Wormald 200_) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | LR | R5 | Lift Motor Room, Entrance | Fire Door (tagged Bismac 2016) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F17 | Rex Vowels Theatre | M | LGQ5 | Plant Room, Mezzanine Area, Above Room LGQ4 | Duct Work Heater Bank | Internal Millboard Insulation | Suspected Negative | - | - | - | Visual inspection undertaken by Noel Arnold & Associates (NAA) in August 2008 identified SMF insulation within the heater bank | No |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LGQ3 | Fire Exit | Fire Door (tagged Fire Door Replacement 1995) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LGQ5 | Fire Exit | Fire Door (tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG10 | Fire Exit | Fire Door (tagged Fire Research 199_) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | G | GQ2 | Fire Exit, Adjacent GQ7 | Fire Door (tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | G | GQ5 | Fire Exit | Fire Door (tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | G | GQ5 | Fire Exit | Fire Door (tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 1Q3 | Fire Exit | Fire Door (tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 1Q4 | Fire Exit | Fire Door (tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | 1Q5 | Plant Room | Fire Door (tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | - | Exterior, UCA Roof Area | Fire Door (timber door) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 2Q2 | Fire Exit | Fire Door (tagged Pacific Fire Doors 2009) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | 2Q3 | Fire Exit | Fire Door (tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 3Q2 | Fire Exit | Fire Door (tagged Wormald 20__) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | 3Q3 | Fire Exit | Fire Door (tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 4Q2 | Fire Exit | Fire Door (tagged Fire Door Replacement 1995) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 4Q3 | Fire Exit | Fire Door (tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 5Q2 | Fire Exit | Fire Door (tagged Bismac 2011) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | 5Q3 | Fire Exit | Fire Door (tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 6Q2 | Fire Exit | Fire Door (tagged Bismac 20__) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | 6Q3 | Fire Exit | Fire Door (tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 7Q2 | Fire Exit | Fire Door (tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | 7Q3 | Fire Exit | Fire Door (tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | R1 | Plant Room Entrance | Fire Door (tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | ROQ2 | Lift Motor Room Entrance | Fire Door (tagged Fire Systems Engineering 199_ - Asbestos Free) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | ROQ3 | Fire Stairwell | Fire Door (tagged Fire Systems Engineering 199_ - Asbestos Free) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | R | R1Q05 | Lift Motor Room | Lift Motors, Unit No. 60 (lift motor plate - installed 2015) | Lift Brake Pads | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | R | R1Q11 | Lift Motor Room | Lift Motors, Unit No. 61 (lift motor plate - installed 2018) | Lift Brake Pads | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | R | R1Q12 | Lift Motor Room | Lift Motors, Unit No. 62 (lift motor plate - installed 2015) | Lift Brake Pads | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F25 | Samuels | R | R01A | Lift Motor Room | Lift Motors, Unit No. 10 (lift motor plate - 2015) | Lift Brake Pads | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F25 | Samuels | R | R20 | Lift Motor Room | Lift Motors, Unit No. 11 (lift motor plate - 2015) | Lift Brake Pads | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | B17 | Goldstein College | LG | LGQ13 | Switch Room | Fire Door (tagged 'Exodus, 2013') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | B17 | Goldstein College | LG-6 | - | Various Fire Stairwells Throughout | Fire Door (tagged 'Exodus, 2013') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | B17 | Goldstein College | G-5 | - | Accommodations Rooms Throughout | Fire Door (tagged 'Exodus, 2013') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | B17 | Goldstein College | LG-5 | - | Electrical Cupboards | Electrical Distribtuion Boards | Electrical Panels | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | B17 | Goldstein College | G-5 | - | Various Locations (Kitchen, Waste Rooms, Lounge Rooms) | Floor Coverings | Grey Sheet Vinyl | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 204 | Cleaners Room | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 306 | Cleaners Cupboard | Fire Door (No tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 317 | Entrance | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 322 | Entrance | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 407 | Cleaners Room | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 504 | Cleaners Room | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 605 | Cleaners Room | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 703 | Cleaners Room | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 804 | Cleaners Room | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 905 | Cleaners Room | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | 1005 | Cleaners Room | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | G | G80 | Electrical Switchboard Cupboard Outside Recreational Room | Inside Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | G | G91 | East Corridor, Outside Room G91, Electrical Switchboard Cupboard | Inside Electrical Switchboard Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | G | G99 | East Corridor, Outside Room G99, Electrical Switchboard Cupboard | Inside Electrical Switchboard Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | G | GQ22 | North Corridor, Electrical Switchboard Cupboard | Inside Electrical Switchboard Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 1 | 1Q1 | North Corridor, Adjacent Room 179, Electrical Switchboard Cupboard | Inside Electrical Switchboard Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 1 | 1Q2 | North Corridor, Outside Room 192, Electrical Switchboard Cupboard | Inside Electrical Switchboard Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 1 | 1Q7 | South Corridor, Outside Room 190, Electrical Switchboard Cupboard | Inside Electrical Switchboard Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 1 | 1Q9 | West Corridor, Adjacent Room 187, Electrical Switchboard Cupboard | Inside Electrical Switchboard Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 2 | 2Q3 | North Corridor, Outside Room 292, Electrical Switchboard Cupboard | Inside Electrical Switchboard Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 2 | 2Q8 | South Corridor, Outside Room 290, Electrical Switchboard Cupboard | Inside Electrical Switchboard Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 3 | 3Q3 | North Corridor, Outside Room 392, Electrical Switchboard Cupboard | Inside Electrical Switchboard Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 3 | 3Q8 | North Corridor, Outside Room 390, Electrical Switchboard Cupboard | Inside Electrical Switchboard Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G6 | Blockhouse | - | R1 | Lift Motor Room | Inside Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAG | Block G | G | GG02 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAG | Block G | G | GGQ3 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAG | Block G | G | GGQ3 | Electrical Cupboard | Fire Doors (tagged 'Tyco, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAG | Block G | 01 | G1Q1 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAG | Block G | 01 | G1Q1 | Electrical Cupboard | Fire Doors (tagged 'Tyco, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAG | Block G | 01 | G122A | Fire Stairs | Fire Doors (tagged 'Tyco, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
FSFG | Fowlers Gap Field Station | FG15 | Fowlers Gap Cottage 1 | G | - | Throughout | Floor Covering | Sheet Vinyl | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B8 | University Terraces | B-7 | - | Various Fire Stairwells Throughout | Fire Door (tagged 'Ikon, 2012') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B8 | University Terraces | G | - | Exterior Throughout | Awning Ceilings | Fibre Cement Sheeting (suspected) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q9 | Stairwell | Fire Door (No Door Tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | LG | - | Electrical Cupboards | Within Electrical Cabinets | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | G | - | Various Fire Stairwells Throughout | Fire Doors (tagged 'Fire Systems Engineering, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | G | G005B | Plant Room | Fire Door (tagged 'Fire Systems Engineering, 199_") | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | G | - | Electrical Cupboards | Within Electrical Cabinets | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | 01 | - | Various Fire Stairwells Throughout | Fire Doors (tagged 'Fire Systems Engineering, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | 01 | - | Electrical Cupboards | Within Electrical Cabinets | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | 02 | - | Electrical Cupboards | Within Electrical Cabinets | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | 02 | - | Various Fire Stairwells Throughout | Fire Doors (tagged 'Fire Systems Engineering, 199_") | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | 03 | - | Electrical Cupboards | Within Electrical Cabinets | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | 03 | - | Various Fire Stairwells Throughout | Fire Doors (tagged 'Fire Systems Engineering, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E15 | Quadrangle | R | - | Various Fire Stairwells Throughout | Fire Doors (tagged 'Fire Systems Engineering, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F13 | Science Theatre | LG | LG1 | Northern End, Eastern Side | Fire Door (tagged 'Radiant, no date') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G04 | Entrance | Fire Door (tagged 'Bismac, 2004') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | LG | LGQ1 | - | Fire Door (no tag - timber top of door) | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | LG | LGQ2 | - | Fire Door (tagged 'Inglis, 1990) | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | LG | LGQ2 | - | Fire Door (tagged 'TDF, 2015) | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | LG | LGQ8 | - | Fire Door (no tag - timber top of door) | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | G | GQ1 | - | Fire Door (tagged 'Fire Control Pty Ltd, 199_') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | G | GQ5 | North & South | Fire Doors (tagged 'Fire Control Pty Ltd, 199_') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | G | GQ8 | - | Fire Door (tagged 'Fire Control Pty Ltd, 199_') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 1Q1 | - | Fire Door (tagged 'Fire Control Pty Ltd, 199_') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 1Q5 | - | Fire Door (tagged 'Fire Control Pty Ltd, 199_') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 1Q8 | - | Fire Door (tagged 'Fire Control Pty Ltd, 199_') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 2Q1 | - | Fire Door (tagged 'Fire Control Pty Ltd, 199_') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 2Q4 | - | Fire Door (tagged 'Fire Control Pty Ltd, 199_') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 2Q6 | - | Fire Door (tagged 'Fire Control Pty Ltd, 199_') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 3Q3 | - | Fire Door (tagged 'Inglis, 1990') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | 03 | 3Q5 | - | Fire Door (tagged 'Fire Control Pty Ltd') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | F8 | Law Building | B-03 | - | Throughout | Fire Doors (tagged 'Ausco, 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G15 | Entrance | Fire Door (tagged 'Tyco, 1997') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G19A | - | Floor Covering | Vinyl Tiles (Grey Colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E26 | Biological Sciences South | LG - 7 | - | Throughout | Fire Doors (tagged 'Ikon, no date) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H22 | Valentine Annexe | 1 | 103A | - | Floor Covering | Vinyl Tiles (Light Brown Colour) | Assumed Negative | - | - | - | - | No |
MANV | Manly Vale | MV7 | Laboratory 4 | G | - | Exterior, Front Entrance | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAA | Block A | B | AB3 | Plant Room | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAE | Block E | G | EG02 | South | Fire Door (tagged 'Tyco, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAE | Block E | 01 | E1Q2 | Stairwell | Fire Door (tagged 'Bismac, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAE | Block E | 01 | E107 | Plant Room Entry | Fire Door (tagged 'Tyco, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAE | Block E | 01 | E110A | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | B | FB07 | West | Fire Doors (tagged 'Protec, 2012') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | B | FBQ8 | Entrance to Plant Room | Fire Doors (tagged 'Protec, 2012') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | B | FBQ8 | Plant Room | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | B | FBQ9 | Entrance to Plant Room | Fire Doors (tagged 'Protec, 2012') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | B | FBQ9 | Plant Room | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | B | FBQ18 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | G | FGQ2 | Stairwell | Fire Door (Tagged 'Bismac 2021') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | G | FGQ53 | Electrical Cupboard | Fire Doors (Tagged 'Tyco, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | G | FGQ53 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | G | FGQ56 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | G | FGQ1 | Stairwell | Fire Door (Tagged 'Bismac 2021') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 01 | F1Q2A | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 01 | F1Q1 | Stairwell | Fire Door (Tagged 'Bismac 2021') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 01 | F1Q7 | Stairwell | Fire Door (Tagged 'Bismac 2021') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 01 | F123 | Throughout | Ductwork Joins | Grey Mastic Sealant | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 02 | F2Q1 | Fire Door (Tagged 'Bismac 2021') | Core Insulation | Not Sampled - New Appearance | - | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 02 | F2Q2 | South Electrical Cupboard | Fire Doors (tagged 'Tyco, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 02 | F2Q2 | South Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 02 | F2Q2B | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 02 | F2Q7 | Stairwell | Fire Door (Tagged 'Bismac 2021') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 03 | F3Q2E | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 03 | F3Q2E | Electrical Cupboard | Fire Doors (tagged 'Tyco, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 03 | F3Q1 | Stairwell | Fire Door (Tagged 'Bismac 2021') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 03 | F3Q7 | Stairwell | Fire Door (Tagged 'Bismac 2021') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 04 | F4Q1 | Stairwell | Fire Door (Tagged 'Protec, 2012') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 04 | F4Q7 | Stairwell | Fire Door (Tagged 'Protec, 2012') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 04 | F4Q2C | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAF | Block F | 04 | F4Q2C | Electrical Cupboard | Fire Doors (Tagged 'Tyco, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H22 | Valentine Annexe | 1 | 115 | - | Floor Covering | Vinyl Tiles (Light Brown Colour) | Assumed Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP1 | Central Amenities | G | G13 | Throughout | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
FSFG | Fowlers Gap Field Station | FG22 | Fowlers Gap Greenhouse | G | - | Exterior | Awning Ceiling | Fibre Cement Sheeting | Suspected Negative | - | - | - | - | No |
FSFG | Fowlers Gap Field Station | FG22 | Fowlers Gap Greenhouse | G | - | Throughout | Flooring | Compressed Fibre Cement Sheeting | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H22 | Valentine Annexe | 1 | - | Exterior, East Side of Building Above Entrance | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSW | Wellington Field Station | WFS4A | Wellington Field Station Cool Room | G | - | Exterior, North Side | Inside Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H22 | Valentine Annexe | 1 | 123 | Now Room 124, Steps to Project Box (removed) | Floor Covering | Vinyl Tiles (Cream Colour) | Assumed Negative | - | - | - | Item removed | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | 1 | 117 | Store Room | Floor Covering | Vinyl Tiles (Cream Colour) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G10 | Above Fume Cupboard | Ductwork Joints | Mastc Sealant | Removed -Assumed Positive | - | - | - | Item Removed. No removal documentation provided. | Yes |
KENC | Kensington Campus | B14D | Fig Tree Theatre | G | 4 | Bar Area | Floor Covering | Vinyl Sheeting | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B15 | Old Tote | G | G01 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | B16 | Colombo House | LG-7 | - | Various Fire Stairwells Throughout | Fire Door (tagged 'Exodus, 2014') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | B16 | Colombo House | LG-7 | - | Electrical Cupboards | Inside Electrical Cabinets | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | B16 | Colombo House | G-6 | - | Various Locations (Kitchen, Lounge Rooms, Waste Rooms) | Floor Coverings | Sheet Vinyl (grey colour) | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | B16 | Colombo House | G-6 | - | Accommodation Rooms Throughout | Fire Door (tagged 'Exodus, 2014') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | B18 | Fig Tree Hall | G-6 | - | Various Fire Stairwells Throughout | Fire Door (tagged 'Exodus, 2013') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | B18 | Fig Tree Hall | G-5 | - | Accommodations Rooms Throughout | Fire Door (tagged 'Exodus, 2013') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | B18 | Fig Tree Hall | G-5 | - | Electrical Cupboards | Inside Electrical Distribtuion Board Cabinets | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | B18 | Fig Tree Hall | G-5 | - | Various Locations | Floor Coverings | Sheet Vinyl (grey colour) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | LG | LGQ02 | Pool (B4), Entrance | Fire Door (tagged 'Bismac, 20__') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | P10 | Pool (B4), Entry | Fire Door (tagged 'Bismac, 2011') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | GQ5 | Gymnasium (B5), East and West | Fire Doors (tagged 'Ikon, 20__) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | G03A | Gymnasium (B5), Switch Room | Fire Door (tagged 'Tyco, 1998') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | G03A | Gymnasium (B5), Switch Room | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 01 | 1Q1 | Gymnasium (B5), West | Fire Doors (Tagged 'Ikon, 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 01 | 1Q1 | Gymnasium (B5), East | Fire Doors (tagged 'Fire Research, 199_' & Fire Door Co. Pty Ltd, no date) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 01 | 1Q2 | Gymnasium (B5), West | Fire Door (tagged 'Wormald, 20__') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 02 | 2Q1 | Gymnasium (B5), East | Fire Door (tagged 'Fire Systems Engineering, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 02 | 202 | Gymnasium (B5), Lift Motor Room | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | GQ7 | Squash Courts (B7), West | Fire Door (tagged 'Bismac, 2015') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | GQ7 | Squash Courts (B7), Electrical Cupboard Adjacent Room 44 | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | GQ8 | Squash Courts (B7), North | Fire Door (tag not legible) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | GQ9 | Squash Courts (B7), Fire Stairs | Fire Door (tagged 'Fire Research, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 02 | 2Q4 | Squash Courts (B7), East | Fire Door (tagged 'Wormald, 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 03 | 3Q4 | Squash Courts (B7), East | Fire Door (tagged 'Cecom, no date') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 03 | 3Q7 | Squash Courts (B7), West | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C15 | White House | G | G03 | North | Electrical Cupboard | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | G | GQ9 | Stairwell | Fire Door (Tagged 'Wormald, 20__') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q3 | Stairwell | Fire Door (tagged 'Fire Control, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q5 | Stairwell | Fire Door (tagged 'Fire Control, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q11 | Stairwell | Fire Door (Tagged 'Fire Door Replacements 1996') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q3 | Stairwell | Fire Door Core (tagged 'Fire Control, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q5 | Stairwell | Fire Door Core (tagged 'Fire Control, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 2 | 2Q9 | Stairwell | Fire Door (tagged 'Bismac, 1998') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q11 | Stairwell | Fire Door (No Door Tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q2, 3Q6, 3Q8, 3Q12 | Roof Space Access Doors | Fire Doors (tagged 'Bismac, 2004') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q3 | Stairwell | Fire Door (tagged 'Fire Control, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | 3 | 3Q5 | Stairwell | Fire Door (tagged 'Fire Control, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G13 | - | Floor Covering | Vinyl Tiles (Grey Colour) | Removed - Assumed Positive | - | - | - | Item Removed 30/1/2016 by Pure Contracting. Refer to Greencap Clearance Certifcate Report (Ref:C107859:J142744). | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G13B | - | Floor Covering | Vinyl Tiles (Grey Colour) | Removed -Assumed Positive | - | - | - | Item Removed by Pure Contracting. Refer to RiskTech Compliance Clearance Certifcate Report dated 15 August 2022. | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G13C | - | Floor Covering | Vinyl Tiles (Grey Colour) | Removed -Assumed Positive | - | - | - | Item Removed by Pure Contracting. Refer to RiskTech Compliance Clearance Certifcate Report dated 15 August 2022. | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G13 | - | Floor Covering | Vinyl Tiles (Blue Colour) | Removed - Assumed Positive | - | - | - | Item Removed 30/1/2016 by Pure Contracting. Refer to Greencap Clearance Certifcate Report (Ref:C107859:J142744). | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G13A | - | Floor Covering | Vinyl Tiles (Blue Colour) | Removed -Assumed Positive | - | - | - | Item Removed by Pure Contracting. Refer to RiskTech Compliance Clearance Certifcate Report dated 15 August 2022. | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G13B | - | Floor Covering | Vinyl Tiles (Blue Colour) | Removed -Assumed Positive | - | - | - | Item Removed by Pure Contracting. Refer to RiskTech Compliance Clearance Certifcate Report dated 15 August 2022. | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G13C | - | Floor Covering | Vinyl Tiles (Blue Colour) | Removed -Assumed Positive | - | - | - | Item Removed by Pure Contracting. Refer to RiskTech Compliance Clearance Certifcate Report dated 15 August 2022. | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | 1 | 123 | Now Room 124, Steps to Project Box (removed) | Floor Covering | Adhesive to concrete | Assumed Positive | - | - | - | Item removed. No removal documentation provided | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G13 | - | Floor Covering | Vinyl Tiles (Black Colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G13 | - | Floor Covering | Vinyl Tiles (Light Blue Colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G20 | - | Floor Covering | Adhesive attached to Grey Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G20A | - | Floor Covering | Adhesive attached to Grey Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G14A | - | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G20 | - | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G20A | - | Floor Covering | Adhesive attached to Blue Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G19 | - | Floor Covering | Vinyl Tiles (Grey Colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G17A | - | Floor Covering | Vinyl Tiles (Grey Colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G17A | - | Floor Covering | Vinyl Tiles (Light Green Colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | 1 | 124 | - | Floor Covering | Vinyl Tiles (Light Green Colour) | Negative | - | - | - | - | No |
KENC | Kensington Campus | H22 | Valentine Annexe | 1 | - | Exterior, East Side of Building Above Entrance | Wall Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | 1 | - | Exterior, North Side of Building Above Entrance | Awning Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H22 | Valentine Annexe | 1 | 117 | Store Room | Floor Covering | Vinyl Tiles (Cream Colour) | Negative | - | - | - | - | No |
KENC | Kensington Campus | H22 | Valentine Annexe | G | - | Exterior, North & South Sides | Window Frames | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | G | - | Exterior, North Side | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G10 | East Adjacent Fume Cupboard | Electrical Switch Board | Electrical Backing Board | Removed - Suspected Positive | - | - | - | Item Removed. No removal documentation provided. | Yes |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | G1B | West | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | G2 | Entrance | Fire Door (tagged 'Bismac, 1998') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | G7A | Entrance | Fire Door (tagged 'Bismac, 1998') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | G11 | Entrance | Fire Door (Tagged 'Bismac, 1998') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | G16 | Entrance | Fire Door (tagged 'Bismac, 1998') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | G20 | Entrance | Fire Door (tagged 'Bismac, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | G23 | Entrance | Fire Door (No Tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | GQ2 | Entrance | Fire Door (tagged 'Protection Engineers, 1994') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | G | GQ4 | Exterior | Fire Door (Not Tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | 01 | 101 | Entrance | Fire Door (tagged 'Bismac, 1998') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | 01 | 103 | Entrance | Fire Door (Tagged 'Bismac, 1998') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C24 | Clancy Auditorium | 01 | 102 | East and West | Fire Doors (tagged 'Bismac, 1998') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C25 | Lowy Cancer Research Centre | B-5 | - | Throughout | Fire Doors (tagged 'Ikon, 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C25 | Lowy Cancer Research Centre | B-5 | - | Electrical Cupboards Throughout | Within Electrical Cabinets | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C27 | Wallace Wurth | LG-7 | - | Throughout | Fire Doors (tagged 'Titan, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C27 | Wallace Wurth | LG-7 | - | Electrical Cupboards Throughout | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | G | G77 | Fire Stairs Exit | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | G | GQ2 | Fire Stairs | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | G | GQ21 | Fire Stairs | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | G | GQ22 | North Corridor, East End | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 1 | 103 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 1 | 104 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 1 | 105 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 1 | 137 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 1 | 138 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 1 | 139 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 1 | 186 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 1 | 1Q5 | Fire Stairs | Fire Doors (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 1 | 1Q11 | Fire Stairs | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 1 | 1Q12 | Fire Stairs | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 1 | 1Q13 | Fire Stairs | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 2 | 203 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 2 | 204 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 2 | 205 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 2 | 237 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 2 | 238 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 2 | 239 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 2 | 2Q2 | Fire Stairs | Fire Doors (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 2 | 2Q6 | Fire Stairs | Fire Doors (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 2 | 2Q11 | Fire Stairs | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 3 | 303 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 3 | 304 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 3 | 305 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 3 | 337 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 3 | 338 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 3 | 339 | Accommodation Room | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 3 | 3Q6 | Fire Stairs | Fire Doors (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | C6 | International House | 3 | 3Q11 | Fire Stairs | Fire Door (tag 'Spartan 2018') | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D10 | Building D10 | G | G07B | Electrical Cupboard | Within Electrical Cupbaord | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | G | EAGQ02 | GQ6 Corridor, Electrical Cupboard (DB-2) | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | G | EAGQ01 | GQ14 Corridor, Electrical Cupboard (DB-1) | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | G | ECGQ01 | GQ10 Corridor, Electrical Cupboard (DB-3) | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | G | GQ3 | Fire Stairwell Entrance | Fire Door (tagged 'Stylewise, 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | G | GQ6 | West End of Corridor | Fire Door (tagged 'Stylewise, 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | G | GQ9 | East End of Corridor | Fire Door (No Door Tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | G | GQ10 | East End of Corridor | Fire Door (tagged 'Stylewise, 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | G | GQ11 | Fire Stairwell Entrance | Fire Door (tagged 'Stylewise, 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | C104 | Entrance | Fire Door (tagged 'Stylewise, 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | EA1Q01 | 1Q3 Corridor, Electrical Cupboard (DB-4) | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | EA1Q02 | 1Q4 Corridor, Electrical Cupboard (DB-5) | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | EB1Q01 | 1Q1 Corridor, Electrical Cupboard (DB-6) | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | EC1Q01 | 1Q5 Corridor, Electrical Cupboard (DB-7) | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | 1Q5 | East | Fire Door (tagged 'Stylewise, 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 01 | 1Q9 | West | Fire Door (tagged 'Stylewise, 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | EA2Q01 | 2Q2 Corridor, Electrical Cupboard (DB-09) | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | EA2Q02 | 2Q3 Corridor, Electrical Cupboard (DB-10) | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | EB2Q01 | 2Q1 Corridor, Electrical Cupboard (DB-10) | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | EC2Q01 | 2Q5 Corridor, Electrical Cupboard (DB-11) | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 02 | 2Q5 | East End of Corridor | Fire Door (tagged 'Stylewise, 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 03 | B310 | Entrance | Fire Door (tagged 'Stylewise, 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 03 | EC3Q01 | 3Q4 Corridor, Electrical Cupboard (DB-13) | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 03 | 3Q1 | West End of Corridor | Fire Door (tagged 'Stylewise, 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 03 | 3Q4 | East End of Corridor | Fire Door (tagged 'Stylewise, 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D14 | UNSW Hall | 03 | 3Q9 | East End of Corridor | Fire Door (tagged 'Stylewise, 200_') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | G | GQ2 | South | Fire Door (tagged 'Bismac, 2006') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | G | GQ4 | North | Fire Door (tagged 'Bismac, 2004') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | G | G08 | Communications Cupboard | Ductwork | Mastic Sealant | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | G | GQ8 | - | Cubicle Partitions | Compressed Fibre Cement Sheeting | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | G | G17 | Plant Room, West | Inside Electrical Distribution Board Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | 01 | 1Q4 | - | Inside Electrical Distribution Board Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | 02 | 206 | North | Floor Covering | Vinyl Tiles (black mottled colour) | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | 02 | M2Q01 | Exterior, Roof Plant Aea, North-East | Inside Electrical Distribution Board Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | 02 | 2Q1 | West | Fire Door (tagged 'Wormald, 201-') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | 02 | 2Q2 | North | Fire Door (tagged 'Wormald, 201-') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | 02 | 2Q4 | North | Fire Door (tagged 'Taylors Door Frames, 2006') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D17 | Basser College | LG-6 | - | Throughout, Fire Stairs, Accommodation Rooms | Fire Doors (tagged 'Exodus, 2013') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D17 | Basser College | LG-6 | - | Throughout, Kitchenettes and Waste Rooms | Floor Covering | Sheet Vinyl | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H22 | Valentine Annexe | 1 | - | Exterior, Western Section, All Sides | Eaves | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H6 | Tyree Energy Technologies Building (TETB) | LG- Roof | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D23 | Mathews Theatres | 01 | 150 | Plant Room, South Entrance | Fire Doors (tagged 'Bismac, 2002') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 01 | 150 | Plant Room, North Entrance | Fire Doors (tagged 'Bismac, 2002') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 03 | 301 | East & West | Fire Door (tagged 'Holland, 1999 and Bismac, 2012') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 03 | 303 | - | Fire Doors (tagged 'Bismac, 2012 and Infinity Fire Protection, 2019') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 03 | 304 | - | Fire Doors (tagged 'Holland, 1999 and Bismac, 2012') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H6 | Tyree Energy Technologies Building (TETB) | LG-5 | - | Electrical Cupboards Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H6 | Tyree Energy Technologies Building (TETB) | LG-5 | - | Service Risers Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H6 | Tyree Energy Technologies Building (TETB) | 4 | 408 | High Temperature Furnace: | Moulded Tube Housing | Insulation (white coloured) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H6 | Tyree Energy Technologies Building (TETB) | 4 | 421 | High Temperature Furnace: | Moulded Tube Housing | Insulation (white coloured) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H6 | Tyree Energy Technologies Building (TETB) | 4 | 408 | High Temperature Furnace: | Beneath Tube Housing (localised sections) | Woven Textile Strap Webbing Insulation (white coloured) | Positive (Chrysotile) - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 5 December 2018. | Yes |
KENC | Kensington Campus | H6 | Tyree Energy Technologies Building (TETB) | 4 | 421 | High Temperature Furnace: | Beneath Tube Housing (localised sections) | Woven Textile Strap Webbing Insulation (white coloured) | Positive (Chrysotile) - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 5 December 2018. | Yes |
KENC | Kensington Campus | H6 | Tyree Energy Technologies Building (TETB) | LG-5 | - | Throughout | Fire Doors (tagged 'Ikon, 201-' & 'Australiasian Fire Doors, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
FSH | Hay Field Station | HFS4 | Hay Field Station Shearing Shed and Laboratory | G | G02 - G04 | Laboratory, Exterior, Sub-Floor Space | On Ground, Debris | Fibre Cement Sheeting | Positive (Amosite & Chrysotile) | Non-friable | Low | P3 | Restrict access to the sub-floor space area to authorised personnel only. Remove fibre cement sheet debris under controlled conditions within a planned control program. | No |
FSH | Hay Field Station | HFS4 | Hay Field Station Shearing Shed and Laboratory | G | G02 - G04 | Laboratory, Exterior | Walls | Profiled Fibre Cement Sheeting | Positive (Amosite & Chrysotile) | Non-friable | Low | P3 | Repair/seal the localised damage areas to the wall sheeting under controlled conditions within a planned control program. Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS4 | Hay Field Station Shearing Shed and Laboratory | G | G02 - G04 | Laboratory, Exterior | Eaves | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS4 | Hay Field Station Shearing Shed and Laboratory | G | G02 | Laboratory | Walls | Fibre Cement Sheeting | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS4 | Hay Field Station Shearing Shed and Laboratory | G | G01 | Shearing Shed, Western Room | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSH | Hay Field Station | HFS4 | Hay Field Station Shearing Shed and Laboratory | G | G01 | Shearing Shed, Western Room | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSH | Hay Field Station | HFS4 | Hay Field Station Shearing Shed and Laboratory | G | G03 | Throughout | Floor Covering | Vinyl Tiles (cream colour) | Negative | - | - | - | - | N/A |
FSH | Hay Field Station | HFS4 | Hay Field Station Shearing Shed and Laboratory | G | G03 | Laboratory, South Wall | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
Kenc | Kensington Campus | D9 | IO Myers Studio | G | G06 | East | Wall | Fibre Cement Sheeting | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E12 | UNSW Business School | G-6 | - | Throughout | Fire Doors (tagged 'Australasian Fire Doors, 2007') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E12 | UNSW Business School | G-6 | - | Electrical Cupboards Throughout | Within Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J18 | Willis Annex | 1 | - | Exterior, East Side of Building, Small Localised Section Behind Service Duct of Air Conditioning Condenser Units | Wall Expansion Joint | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J18 | Willis Annex | 2 | 202 | North Section of Room, Below & Attached to Pressure Tanks | Pipe Work Flange Joints | Gaskets | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J18 | Willis Annex | 2 | - | Exterior, West Side | Awning Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | J18 | Willis Annex | M | 2Q13 | Mezzanine Area, Central Adjacent Entrance | Duct Work, Bracket Joints | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | J18 | Willis Annex | 2 | - | Exterior, Surrounding Building | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E4 | Squarehouse | G | GQ15 | Switch Room Entry | Fire Door (tagged 'Inglis, 1994') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 01 | 1Q2 | North | Fire Door (tagged 'Inglis, 1994') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 01 | 1Q4 | Hydraulic Riser Cupboard | Fire Door (tagged 'Inglis, 1994') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 01 | 1Q4 | Fire Services Riser Cupboard | Fire Door (tagged 'Inglis, 1994') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 01 | 1Q4 | West | Fire Doors (tagged 'Bismac, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 01 | 1Q6 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 01 | 1Q7 | Stairwell | Fire Doors (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 02 | 216 | - | Floor Covering | Sheet Vinyl | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 02 | 2Q1 | North | Fire Door (tagged 'Inglis, 1994') | Sheet Vinyl (green colour) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 02 | 2Q2 | North Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 02 | 2Q3 | Hydraulic Riser Cupboard | Fire Door (tagged 'Inglis, 1994') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 02 | 2Q3 | Fire Services Riser Cupboard | Fire Door (tagged 'Inglis, 1994') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 03 | 3Q1 | Stairwell | Fire Door (tagged 'Fire Door Replacements, 2006') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 03 | 3Q2 | North | Fire Doors (tagged 'Inglis, 1994') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 03 | 3Q3 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 03 | 3Q3 | Hydraulic Duct Riser Cupboard | Fire Door (tagged 'Inglis, 1994') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 03 | 3Q3 | Fire Services Riser Cupboard | Fire Door (tagged 'Inglis, 1994') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 03 | 3Q3 | West | Fire Door (tagged 'Wormald, 20__') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 03 | 3Q4 | - | Floor Covering | Sheet Vinyl (grey colour) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | 03 | 3Q7 | East Entry | Fire Door (tagged 'Infinity Fire Protection, 2014'. Old tag appears to have been removed) | Core Insulation | Positive (chrysotile) | Friable | Low | P2 | Remove fire door by a Class A Contractor within a planned control program. Note: Localised delamination of timber skin at base of door | No |
KENC | Kensington Campus | E4 | Squarehouse | R | RQ1 | South | Fire Door (tagged 'Bismac, 2012') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | R | R1 | Plant Room, West | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | G03 | Throughout | Floor Covering | Sheet Vinyl (black colour) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | G04 | Throughout | Floor Covering | Sheet Vinyl (black colour) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | G07 | Throughout | Floor Covering | Sheet Vinyl (black colour) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | G08 | Throughout | Floor Covering | Sheet Vinyl (black colour) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | G09 | Throughout | Floor Covering | Sheet Vinyl (black colour) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | G09 | South | Fire Door (Tagged 'Taylors Door Frames, 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | G10 | North | Fire Door (Tagged 'Taylors Door Frames, 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | G11 | Throughout | Floor Covering | Black Sheet Vinyl | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | G14 | Throughout | Floor Covering | Sheet Vinyl (black colour) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | G18 | North | Fire Door (Tagged 'Taylors Door Frames, 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | G20 | Throughout Bar Area | Floor Covering | Sheet Vinyl (black colour) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | GQ06 | East | Fire Door (Tagged 'Taylors Door Frames, 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | GQ08 | South | Fire Door (Tagged 'Taylors Door Frames, 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | GQ08 | Throughout | Floor Covering | Sheet Vinyl (black colour) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | GQ09 | Throughout | Floor Covering | Sheet Vinyl (black colour) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | GQ10 | Throughout | Floor Covering | Sheet Vinyl (black colour) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | GQ11 | Throughout | Floor Covering | Sheet Vinyl (black colour) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | GQ14 | North | Fire Door (Tagged 'Taylors Door Frames, 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | GQ15 | Throughout | Pipework | Rubber Gaskets | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | G | GQ17 | Main Switch Room | Within Electrical Cabinets | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | 01 | 101C | Kitchen Area | Floor Covering | Sheet Vinyl (blue colour) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | 01 | 102 | South | Fire Door (Tagged 'Taylors Door Frames, 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | 01 | 103 | East | Fire Door (Tagged 'Taylors Door Frames, 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | 01 | 103 | Throughout | Floor Covering | Sheet Vinyl (black colour) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | 01 | 108A | North and South | Fire Door (Tagged 'Taylors Door Frames, 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | 01 | 109 | Throughout | Floor Covering | Sheet Vinyl | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | 01 | 110A | West | Fire Door (Tagged 'Taylors Door Frames, 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | 01 | 111A | South | Fire Door (Tagged 'Taylors Door Frames, 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | 01 | 112 | Throughout | Floor Covering | Sheet Vinyl (grey colour) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | 01 | 1Q09 | Throughout | Floor Covering | Sheet Vinyl (black colour) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F17 | Rex Vowels Theatre | LG | LGQ2 | Entrance Lobby | Floor Covering | Vinyl Sheeting | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | LG | LG7 | Hydraulic Pump Room | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | LG | - | South West Plant Room. | Air Vents (from Main Service Tunnel) | Moulded Fibre Cement Pipes | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | LG | 101 | South West Plant Room, | Fire Doors (tagged ' Bismac 2012) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 1 | 1Q28 | Former Hoist Room Adjacent Goods Lift | Fire Door | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 1 | E1Q01 | Electrical Room off Fire Stairs (1Q2) | Inside Old Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 2 | 242 | Electrical Room Adjacent Fire Stairs (2Q16) | Inside Electrical Cabinets (new appearance electrical cabinets) | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 2 | 2Q6 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 2 | 2Q7 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 2 | 2Q10 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 2 | 2Q11 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 2 | 2Q12 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 2 | 2Q14 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 3 | 300G | Former Hoist Room Adjacent Goods Lift | Fire Door | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 3 | 322 | Electrical Room Adjacent Fire Stairs (3Q14) | Inside Electrical Cabinet (new appearance electrical cabinet) | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 3 | 3Q4 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 3 | 3Q6 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 3 | 3Q7 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 3 | 3Q8 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 3 | 3Q9 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 3 | 3Q10 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 3 | 3Q12 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 4 | 4Q5 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | No | |
KENC | Kensington Campus | F21 | Library | 4 | 4Q10 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | No | |
KENC | Kensington Campus | F21 | Library | 4 | 4Q11 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 4 | 4Q12 | - | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 4 | 4Q13 | - | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 4 | 4Q14 | - | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 4 | 4Q15 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 4 | 4Q17 | Electrical Cupboard Adjacent Fire Stairs (4Q3) | Inside Electrical Cabinets (new appearance electrical cabinet) | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 5 | 503A | Former Hoist Room Adjacent Goods Lift | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 5 | 5Q1 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 5 | 5Q2 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 5 | 5Q3 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 5 | 5Q4 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 5 | 5Q5 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 6 | 605 | Former Hoist Room Adjacent Goods Lift | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 6 | 6Q1 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 6 | 6Q2 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 6 | 6Q3 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 6 | 6Q4 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 6 | 6Q5 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 7 | 705A | Former Hoist Room Adjacent Goods Lift | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 7 | 7Q1 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 7 | 7Q2 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 7 | 7Q3 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 7 | 7Q4 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 7 | 7Q5 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 8 | 805 | Former Hoist Room Adjacent Goods Lift | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 8 | 8Q1 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 8 | 8Q2 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 8 | 8Q3 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 8 | 8Q4 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 8 | 8Q5 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 9 | 905 | Former Hoist Room Adjacent Goods Lift | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 9 | 9Q1 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 9 | 9Q5 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 9 | 9Q6 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 9 | 9Q7 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 9 | 9Q8 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 10 | 1004 | Former Hoist Room Adjacent Goods Lift | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 10 | 10Q3 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 10 | 10Q6 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 10 | 10Q8 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 10 | 10Q9 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 11 | 1105 | Former Hoist Room Adjacent Goods Lift | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 11 | 11Q2 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 11 | 11Q6 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 11 | 11Q8 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 11 | 11Q9 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 12 | 1212A | Former Hoist Room Adjacent Goods Lift | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 12 | 12Q1 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 12 | 12Q5 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 12 | 12Q7 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 13 | 1309A | Former Hoist Room Adjacent Goods Lift | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 13 | 13Q1 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 13 | 13Q5 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 13 | 13Q8 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 14 | 14Q1 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 14 | 14Q4 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 14 | 14Q6 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 2010') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 15 | 1502 | Boiler Room | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 200-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 15 | 1503 | Former Book Hoist Motor Room | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 200-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 15 | 15Q1 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 200-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 15 | 15Q3 | Fire Stairs | Fire Door (tagged 'Shield Manufacturing Pty Ltd, 200-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q7 | - | Fire Door (tagged 'Bismac 2012') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q7 | Plantroom (access via stairs) | Fire Door (tagged 'Stylewise 201-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q8 | - | Fire Door (tagged 'Bismac 2012') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 917 | - | Fire Door (tagged 'Bismac 2005') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F25 | Samuels | LG-5 | - | Throughout | Fire Doors (tagged 'Bismac, 2018' or 'Holland, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F25 | Samuels | LG-5 | - | Electrical Distribution Cupboards | Inside Electrical Cabinets | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J18 | Willis Annex | 1 | 1Q01 | Hallway Adjacent Room 1Q12, Ceiling Space | Duct Work Heater Bank | Internal Insulation Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J18 | Willis Annex | 1 | - | Hallway Outside Room 114 & Service Plant Rooms | Fire Doors (tagged 'Exodus Doors, 2015') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J18 | Willis Annex | 1 | E01Q02 & E01Q04 | Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J18 | Willis Annex | 2 | - | Hallway & Service Plant Rooms | Fire Doors (tagged 'Exodus Doors, 2015') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J18 | Willis Annex | M | MMQ02 | Mezzanine Plant Room Area, North | Duct Work Heater Banks x2 | Internal Insulation Board | Suspected Negative | - | - | - | - | No |
KENE | Kensington Environs | KS9 | Owls House Building 1 | - | - | Throughout Building | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | G15 | Robert Webster Theatres | 01 | 191B | South, Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | G15 | Robert Webster Theatres | 01 | 191 | South | Fire Door (tagged 'Fire Control, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | G15 | Robert Webster Theatres | 02 | 291 | South, Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | G15 | Robert Webster Theatres | 02 | 291 | South | Fire Door (tagged 'Fire Control, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G17 | Electrical Engineering | LG | ELGQ01 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G17 | Electrical Engineering | G | EGQ01 - EGQ06 | Electrical Cupboards | Within Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G17 | Electrical Engineering | G | GQ16 | Fire Stairwell | Fire Doors (tagged 'Lewis Doors 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G17 | Electrical Engineering | G | - | Throughout | Fire Doors (tagged 'Lewis Doors 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G17 | Electrical Engineering | 1 | E1Q01 - E1Q06 | Electrical Cupboards | Within Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G17 | Electrical Engineering | 1 | 1Q16 & 1Q03 | Fire Stairwell | Fire Doors (tagged 'Lewis Doors 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G17 | Electrical Engineering | 1 | - | Throughout | Fire Doors (tagged 'Lewis Doors 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G17 | Electrical Engineering | 2 | E2Q01 - E2Q04 | Electrical Cupboards | Within Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G17 | Electrical Engineering | 2 | 2Q16 & 2Q03 | Fire Stairwell | Fire Doors (tagged 'Lewis Doors 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G17 | Electrical Engineering | 2 | - | Throughout | Fire Doors (tagged 'Lewis Doors 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G17 | Electrical Engineering | 3 | E3Q01 - E3Q04 | Electrical Cupboards | Within Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G17 | Electrical Engineering | 3 | 3Q16 & 3Q03 | Fire Stairwell | Fire Doors (tagged 'Lewis Doors 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G17 | Electrical Engineering | 3 | - | Throughout | Fire Doors (tagged 'Lewis Doors 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G17 | Electrical Engineering | 4 | E4Q01 - E4Q04 | Electrical Cupboards | Within Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G17 | Electrical Engineering | 4 | 4Q16 & 4Q03 | Fire Stairwell | Fire Doors (tagged 'Lewis Doors 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G17 | Electrical Engineering | 4 | - | Throughout | Fire Doors (tagged 'Lewis Doors 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G17 | Electrical Engineering | R | R1Q16 & R1Q05 | Fire Stairwell | Fire Doors (tagged 'Lewis Doors 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G17 | Electrical Engineering | R | - | Throughout | Fire Doors (tagged 'Lewis Doors 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENE | Kensington Environs | KS9 | Owls House Building 1 | G | UGQ01 | Exterior, Southern Side, Covered Terrace | Awning Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENE | Kensington Environs | KS9 | Owls House Building 1 | G | UGQ02 | Exterior, Southern Side, Covered Terrace | Awning Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENE | Kensington Environs | KS9 | Owls House Building 1 | G | UGQ02 | Exterior, Southern Side, Covered Terrace | Awning Infill Side Panels | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENE | Kensington Environs | KS9 | Owls House Building 1 | G | UGQ03 | Exterior, Western Side | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | KS9 | Owls House Building 1 | 1 | - | External | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | G | - | Exterior, West, Patio Adjacent Room G16 | Awning Ceiling | Fibre Cement Sheeting | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 4 | 402 & 404 | Entrances | Fire Doors (tagged 'post 1990') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H13 | The Red Centre | B-6 | - | Throughout, Fire Stairs | Fire Doors (tagged 'Ingliss, 1998') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H13 | The Red Centre | R | RQ01 | Roof, Lift Motor Room | Walls & Ceiling Sections | Fibre Cement Sheeting | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H13 | The Red Centre | R | RQ01 | Exterior, Throughout | Roof Covering | Rubber Membrane | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 01 | 1Q1 | South | Fire Door (tagged 'Bismac, 2016') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 01 | E1Q01 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 01 | 1Q4 | Stairwell | Fire Door (tagged 'Bismac, 2020') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 02 | E2Q01 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 03 | E3Q01 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 04 | 4Q1 | Stairwell | Fire Door (tagged 'Bismac, 2012') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 04 | 4Q2 | Stairwell | Fire Door (tagged 'Bismac, 2011') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 04 | E4Q01 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 05 | 5Q1 | Stairwell | Fire Door (tagged 'Bismac, 2011') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 05 | 5Q4 | Stairwell | Fire Door (tagged 'Bismac, 2011') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 05 | E5Q01 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 06 | E6Q01 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 06 | 6Q2 | Stairwell | Fire Door (tagged 'Bismac, 2011') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | J14 | Keith Burrows Theatre | G | - | Exterior, North Side, (roof above northern section of Room G1), Upper Roof Membrane Layer | Roof Covering | Rubber Membrane | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J17 | Ainsworth Building | G | GQ01 | Fire Stairwell | Fire Doors (Tagged 'Exodus Doors 2015') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J17 | Ainsworth Building | G | GQ05 | Electrical Cupboards Throughout | Within Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J17 | Ainsworth Building | 1 | 1Q01 | Fire Stairwell | Fire Doors (Tagged 'Exodus Doors 2015') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J17 | Ainsworth Building | 1 | E1Q01 | Electrical Cupboards Throughout | Within Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J17 | Ainsworth Building | 1 | 1Q08 | Main Switch Room | Within Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J17 | Ainsworth Building | 2 | 2Q01 | Fire Stairwell | Fire Doors (Tagged 'Exodus Doors 2015') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J17 | Ainsworth Building | 2 | E2Q01 | Electrical Cupboards Throughout | Within Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J17 | Ainsworth Building | 3 | 3Q01 | Fire Stairwell | Fire Doors (Tagged 'Exodus Doors 2015') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J17 | Ainsworth Building | 3 | E3Q01 | Electrical Cupboards Throughout | Within Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J17 | Ainsworth Building | 4 | 4Q01 | Fire Stairwell | Fire Doors (Tagged 'Exodus Doors 2015') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J17 | Ainsworth Building | 4 | E4Q01 | Electrical Cupboards Throughout | Within Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J17 | Ainsworth Building | 5 | 5Q01 | Fire Stairwell | Fire Doors (Tagged 'Exodus Doors 2015') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | J17 | Ainsworth Building | 5 | E5Q03 | Electrical Cupboards Throughout | Within Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENE | Kensington Environs | KS9 | Owls House Building 1 | G | G05 | East Side | Fire Door (tagged 'Advanced Metal Door Frames') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENE | Kensington Environs | KS9 | Owls House Building 1 | G | GQ10 | Electrical Distribution Board Cupboard off GQ5 | Inside Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENE | Kensington Environs | KS9 | Owls House Building 1 | 1 | 105 | East Side | Fire Door (tagged 'Advanced Metal Door Frames') | Insulation Core | Suspected Negative | - | - | - | - | No |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | LG-1 | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | LG | - | Laundry Toilet | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K14 | Physics Theatre | LG | LG15 | North | Fire Door (tagged 'Radiant') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K14 | Physics Theatre | LG | LGQ7 | East | Fire Door (tagged 'Fyrecon') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | LG | ELGQ01 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | LG | ELGQ02 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | LG | LGQ3 | - | Fire Doors (tagged 'Fire Control, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | LG | LGQ4 | - | Fire Doors (tagged 'Fire Control, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | LG | LGQ6 | North-West | Fire Door (tagged 'Fyrecon, no date') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | LG | LGQ12 | North-West | Fire Door (tagged 'Fyrecon, no date') | Core Insulation | Suspected Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q1 | Fire Stairs | Fire Door (tagged Fyrecon & Inglis 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q4 | Fire Stairs | Fire Door (tagged 'Fire Control 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q6 | Fire Stairs | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q7 | North, Adjacent 1Q17 | Fire Door (tagged 'Fire Control 199_' & 'Fyrecon') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q7 | East | Fire Door (tagged Fyrecon') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q8 | Fire Stairs | Fire Door (tagged 'Pyropanel Asbestos Free Door, 1989') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q18 | East | Fire Door (tagged 'Fyrecon, no date') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 2Q3 | East | Fire Door (tagged 'Fire Control 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 2Q3 | West | Fire Door (tagged 'Fyrecon and Ingliss 1990') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 2Q4 | Stairwell | Fire Door (tagged 'Inglis, 1990'_) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15B | Substation 31 | G | - | Central | Within Switchgear | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | LG | LGQ2 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | LG | LGQ4 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | LG | LGQ8 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | LG | LGQ10 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | G | GQ1 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | G | GQ5 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | G | GQ13 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | G | GQ16 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | G | G01 | Fire Hydrant Pump & Sprinkler Valve Room | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | G | G23 | Loading Dock | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | G | G23C | Main Switch Room | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | G | G23D | Substation Area | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | 1 | 1Q5 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | 1 | 1Q8 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | 1 | 1Q11 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | 1 | 1Q13 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | 2 | E2Q1 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | 2 | E2Q2 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | 2 | W2Q13 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | 2 | W2Q16 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | 3 | E3Q1 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | 3 | E3Q2 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | 3 | W3Q13 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | 3 | W3Q16 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | 4 | E4Q1 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | 4 | E4Q2 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | 5 | E5Q1 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | 5 | E5Q2 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | 6 | E6Q1 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | 6 | E6Q2 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | L5 | Building L5 | Roof | RQ1 | Fire Stairs | Fire Door (tagged 'Premium Doors 2005 | Insulation Core | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | M15 | Rupert Myers | 01-05 | - | Fire Stairs, Throughout | Fire Door (tagged 'Inglis, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | M15 | Rupert Myers | 01-05 | - | Various Kitchenettes | Floor Covering | Sheet Vinyl | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | M15 | Rupert Myers | 03 | 3049, 3050 & 3071 | Throughout | Floor Covering | Sheet Vinyl (grey colour) | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | M15 | Rupert Myers | 03 | 3116 | Throughout | Floor Covering | Sheet Vinyl (cream colour) | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 01 | 1Q1 | South | Fire Door (tagged 'Gathis Manufacturing, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 01 | 1Q2 | North | Fire Door (tagged 'Gathis Manufacturing, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 01 | 1Q3 | West | Fire Door (tagged 'Bismac, 2012') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 02 | 2Q1 | South | Fire Door (tagged 'Gathis Manufacturing, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 02 | 2Q2 | North | Fire Door (tagged 'Gathis Manufacturing, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 02 | 2Q3 | North | Fire Door (tagged 'Gathis Manufacturing, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 02 | 2Q4 | East | Fire Door (tagged 'Wormald, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 03 | 3Q1 | South | Fire Door (tagged 'Gathis Manufacturing, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 03 | 3Q2 | North | Fire Door (tagged 'Gathis Manufacturing, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 03 | 3Q3 | North | Fire Door (tagged 'Gathis Manufacturing, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 03 | 3Q4 | East | Fire Door (tagged 'Gathis Manufacturing, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 04 | 4Q1 | South | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 04 | 4Q2 | North | Fire Door (tagged 'Gathis Manufacturing, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 04 | 4Q3 | North | Fire Door (tagged 'Fire Research, 199_) | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 04 | 4Q4 | East | Fire Door (tagged 'Gathis Manufacturing, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 05 | 5Q1 | South | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 05 | 5Q2 | North | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 05 | 5Q3 | North | Fire Door (tagged 'Gathis Manufacturing, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N18 | Barker Street Parking Station | 05 | 5Q4 | East | Fire Door (tagged 'Gathis Manufacturing, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G7 | Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENE | Kensington Environs | AS24 | 24 Arthur Street | G | - | Exterior, Rear | Eaves | Fibre Cement Sheeting | Suspected Negative | - | - | - | - | No |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | LG | - | Adjacent Comms Cupboard, Surrounding Laundry | Wall Infill Panel | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | HS46 | 46 High Street | G | - | Switch Room, West Side | Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENE | Kensington Environs | HS46 | 46 High Street | 1-03 | - | Throughout | Fire Doors (suspected tagged 'Bismac, 2004') | Core Insulation | Suspected Negative | - | - | - | No | |
KENE | Kensington Environs | HS46 | 46 High Street | 02 | - | Unit 13 | Fire Door (suspected tagged 'Bismac, 2004') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENE | Kensington Environs | HS46 | 46 High Street | 03 | - | Unit 7 | Fire Door (suspected tagged 'Bismac, 2004') | Core Insulation | Suspected Negative | - | - | - | - | No |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | LG | - | Main Switch Room | Electrical Distribution Board | Electrical Backing Board | Negative | - | - | - | - | N/A |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | G | - | Block P, Recreation Room | Window Frames | Putty | Negative | - | - | - | - | N/A |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | G | - | Exterior, Block P, Recreation Room | Wall Cladding | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | MS48A | Owls House Building 2 | G | - | Exterior, East Side, Main Switchboard Cupboard | - | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENE | Kensington Environs | MS48A | Owls House Building 2 | G | G01 | Exterior, West Side | Fire Door | Insulation Core | Suspected Negative | - | - | - | - | No |
MANV | Manly Vale | MV1 | Laboratory 1 | G | G01 | North-East | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | G | - | Block P, Recreation Room, Kitchenette | Floor Covering | Sheet Vinyl (grey colour) | Negative | - | - | - | - | N/A |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | 1 | - | Block P, Unit 33 | Fire Door (tagged 'Womald, 20__') | Core Insulation | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G1Q | Adjacent Main Entrance | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
MANV | Manly Vale | MV3 | Laboratory 2 | G | - | Male and Female Toilets | Wall Lining | Fibre Cement Sheeting | Suspected Negative | - | - | - | - | No |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | 1 | - | Block P, Unit 33, Kitchen | Floor Covering | Vinyl Tiles (black colour) | Negative | - | - | - | - | N/A |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | G | - | Exterior, Block P | Column | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R14 | Institute of Languages | G-2 | - | Ground Level to Level 3, Electrical Riser Cupboard | Fire Doors Door tagged ' Australasian Fire Doors, 1999' | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | 02 | 2Q2 | South-West | Inside Electrical Distribution Board Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
FSFG | Fowlers Gap Field Station | FG4 | Fowlers Gap Cottage 5 | G | G01 | Kitchen | Floor Covering | Sheet Vinyl | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | GQ1 | Stairwell | Fire Doors (tagged 'Inglis 199_ and Fyrecon') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | GQ3 | - | Fire Doors (tagged 'GRG, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | EGQ2 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | EGQ3 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | EGQ4 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | GQ6 | - | Fire Doors (tagged 'Fyrecon, no date') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | G | GQ15 | - | Fire Doors (tagged 'Cecon 1999_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | LR | R5 | Lift Motor Room | Lift Motors (installed 2005) | Brake Pads | Suspected Negative | - | - | - | - | No |
MISC | Miscellaneous | BC34 | Woolley House | - | - | Exterior, Near Main Entry | Inside Electrical Cabinet | Electrical Backing Board (timber backing board) | Suspected Negative | - | - | - | - | No |
MISC | Miscellaneous | BC34 | Woolley House | 01 | G04 | Laundry | Inside Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 701 - 716 | - | Panel Above Doors | Solid Timber | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 901 - 929 | - | Panel Above Doors | Solid Timber | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 1001 - 1010 | - | Panel Above Doors | Solid Timber | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1101 - 1112 & 1118 - 1127 | - | Panel Above Doors | Solid Timber | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAE | Block E | B | EB05B | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAE | Block E | B | EB05B | Electrical Cupboard | Fire Door (tagged 'Tyco, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAE | Block E | B | EBG1 | Fire Stairs | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAE | Block E | G | EG05A | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | LGQ7 | Stairwell | Fire Door (tagged 'Bismac, 1998') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C20 | Morven Brown | LG | LGQ8 | Stairwell | Fire Door (No Door Tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | 03 | D3Q2 | Boiler Room | Boiler Plant and Equipment | Rubber Gaskets | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 02 | 203 | Gymnasium (B5), North | Window Frames (between frame and pane) | Rubber Sealant | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | - | Squash Courts (B7), Throughout | Window Frames (between frame and pane) | Rubber Sealant | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 01 | - | Squash Courts (B7), Throughout | Window Frames (between frame and pane) | Rubber Sealant | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 02 | - | Squash Courts (B7), Throughout | Window Frames (between frame and pane) | Rubber Sealant | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 03 | - | Squash Courts (B7), Throughout | Window Frames (between frame and pane) | Rubber Sealant | Suspected Negative | - | - | - | - | No |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | G | - | Exterior, Block N | Column | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | G | - | Exterior, Block M | Column | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E4 | Squarehouse | R | - | Exterior, Upper Roof Level | Roof Covering | Rubber Membrane | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | 103 | Main Switch Room | - | Electrical Backing Boards (new appearance boards) | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | N13 | Barker Apartments | 1 | 112 | Sub-Switchboard Cupboard | - | Electrical Backing Boards (new appearance boards) | Suspected Negative | - | - | - | - | No |
KENE | Kensington Environs | BS22 | Tiggers Place | LG | B01 | East Side, SE Corner | Inside Electrical Cabinet | Electrical Backing Board (new appearance board) | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | B | DBQ6A | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | B | DBQ11 | Stairwell | Fire Door (Tagged 'Protec, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | B | DBQ2A | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | B | DBQ9 | East | Fire Doors (Tagged 'Protec, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | B | DBQ3A | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | B | DB17 | Store Beneath Stairwell | Fire Door (Tagged 'Protec, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | G | DGQ12 | Stairwell | Fire Door (Tagged 'Protec, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | G | DGQ12A | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | G | DGQ1 | Stairwell | Fire Doors (Tagged 'Protec, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | G | DGQ3 | Stairwell | Fire Doors (Tagged 'Protec, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | G | DGQ3A | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | G | DGQ12A | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | G | - | Exterior, East | Ceiling Panels | Fibre Cement Sheeting | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | 01 | D1Q1 | Stairwell | Fire Doors (Tagged 'Protec, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | 01 | D1Q5 | South | Fire Doors (Tagged 'Protec, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | 01 | D1Q2A | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | 01 | D1Q5A | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | 02 | D2Q11 | Stairwell | Fire Door (Tagged 'Protec, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | 02 | D2Q1 | Stairwell | Fire Door (Tagged 'Protec, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | 02 | DQ2QA | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | 02 | D2Q6A | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | 03 | D3Q12 | Stairwell | Fire Door (Tagged 'Protec, 201_') | Core Insulation | Suspected Negative | No | ||||
COFA | Paddington Campus | CFAD | Block D | 03 | D3Q3 | Cooling Tower Plant Room, East Side | Window Sill | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
COFA | Paddington Campus | CFAD | Block D | 03 | D3Q1 | Stairwell | Fire Door (Tagged 'Protec, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 1 | 1Q04 | Fire Exit | Fire Door (Tagged 1991) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 3Q03 | Fire Exit | Fire Door (Tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 4Q03 | Fire Exit | Fire Door (Tagged Tyco 200_) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 4Q07 | Fire Exit | Fire Door (Tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 5Q02 | Fire Exit | Fire Door (Tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 5 | 5Q04 | Fire Exit | Fire Door (Tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 6 | 6Q02 | Fire Exit | Fire Door (Tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 6 | 6Q04 | Fire Exit | Fire Door (Tagged Inglis 1999) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 7 | 7Q01 | Fire Exit | Fire Doors (Tagged Bismac 2002) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 7 | 701 | Entrance | Fire Door (Tagged 'Bismac, 2004') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 7 | 703 | Lift Motor Room | Fire Door (Tagged Bismac 2013) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E6 | Roundhouse | 01 | Fomer Room 116 | Bar Area, Low Level | Infill Panels | Fibre Cement Sheeting | Suspected Negative - Removed | - | - | - | - | Yes |
KENC | Kensington Campus | F21 | Library | 3 | - | Old Northern Building Section, Throughout | Within Wall Cavities & Voids and On Soffit Above Brick Walls & Services | Insulation Residue & Debris | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 3 | - | Old Northern Building Section, Throughout | On Soffit Surrounding Columns, Beneath New Insulation Board | Insulation Residue & Bituminous Coating (adhesive) | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | - | Throughout, Blockwork Walls | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | - | Throughout, Blockwork Walls | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | - | Throughout, Blockwork Walls | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | - | Throughout, Blockwork Walls | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | - | Throughout, Blockwork Walls | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | - | Throughout, Blockwork Walls | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | - | Throughout, Blockwork Walls | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | - | Throughout, Blockwork Walls | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | - | Throughout, Blockwork Walls | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | - | Throughout, Blockwork Walls | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | - | Throughout, Blockwork Walls | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | - | Throughout, Blockwork Walls | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | - | Throughout, Blockwork Walls | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | - | Throughout, Blockwork Walls | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | - | Throughout, Blockwork Walls | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | - | Throughout, Blockwork Walls | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Investigate presence and extent of this asbestos material prior to demolition or refurbishment. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 18 | 1801 | East & South, Above Set Ceiling | On Top of Blockwork Walls | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | - | Various Locations - Ceiling Space (Assume all Classrooms) | Ductwork Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 6Q2 | Electrical Cupboard | Inside Link Box (no access) | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Confirm status. If positive, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B14D | Fig Tree Theatre | G | 6A | Stage Area | Within Electrical Cabinet | Electrical backing board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B14D | Fig Tree Theatre | SF | - | Subfloor Area | Asbestos Materials | Unknown | Suspected Positive | - | - | P4 | Signage installed indicating asbestos materials located within the subfloor - no access provided during the inspection. Caution should be exercised when access is required. | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G07 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 01 | 1Q1 | North | Fire Door (tagged 'Metabilt Industries, no date') | Core Insulation | Removed - Positive (chrysotile & amosite) | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 15 October 2020. Note: New fire door tagged 'Bismac, 2020'. | Yes |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 01 | 1Q3 | Stairwell | Fire Door (tagged 'Wormald, 201_') | Core Insulation | Suspected Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 02 | 2Q2 | Stairwell | Fire Door (tagged 'Bridgewater Trading and Engineering, no date') | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 02 | 2Q3 | Stairwell | Fire Door (tagged 'Bridgewater Trading and Engineering, no date') | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 02 | 2Q4 | Stairwell | Fire Door (tagged 'Bridgewater Trading and Engineering, no date') | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 03 | 3Q2 | Stairwell | Fire Door (tagged 'Robson Door, 202_, 2020') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 03 | 3Q3 | Stairwell | Fire Door (tagged 'Bridgewater Trading and Engineering, no date') | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 03 | 3Q4 | Stairwell | Fire Door (tagged 'Bridgewater Trading and Engineering, no date') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 04 | 4Q3 | Stairwell | Fire Door (tagged 'Bridgewater Trading and Engineering, no date') | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 04 | 4Q4 | Stairwell | Fire Door (tagged 'Bridgewater Trading and Engineering, no date') | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 05 | 5Q2 | Stairwell | Fire Door (tagged 'Bridgewater Trading and Engineering, no date') | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 06 | 6Q3 | Stairwell | Fire Door (tagged 'Bismac, 2020') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 06 | 6Q4 | Stairwell | Fire Door (tagged 'Bridgewater Trading and Engineering, no date') | Core Insulation | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | J14 | Keith Burrows Theatre | G | G05 | South West Exit | Fire Door (no tag) | Core Insulation | Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | B | BQ1 | Western Fire Stairs | Fire Door (no tag) | Insulation Core | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | G | GQ5 | North & South | Panel Above Fire Door | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | 01 | 1Q5 | North & South | Panel Above Fire Door | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 2Q4 | North & South | Panel Above Fire Door | Core Insulation | Negative | - | - | - | - | No |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | G | - | Exterior, Block L | Column | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | G | - | Exterior, Block K | Column | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | B21 | Repository | R | - | Exterior, Throughout, Beneath Rock Bedding | Roof Covering | Bituminous Membrane (may be present beneath new membrane) | Suspected Positive | Non-friable | Low | P4 | Confirm potential presence of an asbestos membrane layer beneath new membrane and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | P09A | Pool (B4), Cleaner's Store | Fire Door (tagged 'Masterbilt, No date') | Core Insulation | Removed - Positive (chrysotile & amosite) | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 16 December 2019. Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 03 | - | Squash Courts (B7), Exterior, Southern Side | Roof Covering, Beneath New Rubber Membrane | Suspected Bitumen Membrane | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status and if contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | G | - | Exterior, Block J | Column | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 1Q5 | Fire Stairwell | Fire Door (no tag) | Core Insulation | Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 4Q5 | Fire Stairwell | Fire Door (no tag) | Core Insulation | Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 6Q5 | Fire Stairwell | Fire Door (no tag) | Core Insulation | Negative | - | - | - | - | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 714 | Southwest Corner, Ceiling | Air Conditioning Ductwork Heater Bank | Millboard Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | LR | R1 | Western End, Boiler | Boiler (internal insulation) | Insulation | Suspected Positive | Friable | Low | P4 | Confirm status. If positive, maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F17 | Rex Vowels Theatre | LG | LGQ1 | Exterior, Awning, Roof | Roof Covering (beneath new membrane layer) | Bituminous Membrane | Suspected Positive | Non-friable | Low | P4 | Confirm potential presence of an asbestos membrane layer beneath new membrane layer and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F17 | Rex Vowels Theatre | LG | LGQ5 | Plant Room Central, Above Compressor | Old Air Conditioning Ductwork Flange Joints Associated with Ductwork Heater Banks | Mastic Sealant | Removed - Assumed Positive | - | - | - | Item Removed - Refer to RiskTech Compliance Asbestos Clearance Certificate dated 19 November 2020. | Yes |
KENC | Kensington Campus | F20 | Goodsell | B | - | Throughout | Ductwork Flange Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G24 | Ceiling Space | Ductwork Flange Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G28A | Plumbling Duct Adjacent Room G28A Toilets | Ductwork Flange Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G28A | Ceiling Space | Ductwork Flange Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 122A | Ceiling Space | Ductwork Flange Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 126A | Plumbling Duct Adjacent Room 126A Toilets | Ductwork Flange Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 01 | 1Q2A | Ceiling Space Note: Previously Room 126A | Ductwork Flange Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 236A | Ceiling Space | Ductwork Flange Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 238 | Ceiling Space | Ductwork Flange Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 | 238 | Plumbling Duct Adjacent Room 238 Toilets | Ductwork Flange Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | LG | LG6 | Southeast Corner, Above Kitchenette | Duct Heater Bank | Millboard | Suspected Positive | Friable | Low | P3 | Confirm status of millboard insulation within heater banks under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor within a planned control program. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | RQ05 | Throughout (Under Concrete Pavers) | Floor Covering | Bituminous Membrane | Suspected Positive | Non-friable | Low | P4 | Consider installation of appropriate warning signage indicating the potential presence of an asbestos membrane layer beneath concrete pavers. Confirm potential presence of an asbestos membrane layer beneath concrete pavers and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | RQ06 | Throughout (Under Concrete Pavers) | Floor Covering | Bituminous Membrane | Suspected Positive | Non-friable | Low | P4 | Consider installation of appropriate warning signage indicating the potential presence of an asbestos membrane layer beneath concrete pavers. Confirm potential presence of an asbestos membrane layer beneath concrete pavers and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | RQ01 | Roof Level, Room RQ06, Roof Covering Beneath Concrete Pavers | Floor Covering | Bituminous Roof Membrane | Positive | Non-friable | Low | P4 | Consider installation of appropriate warning signage indicating the potential presence of an asbestos membrane layer beneath concrete pavers. Confirm potential presence of an asbestos membrane layer beneath concrete pavers and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 03 | 3Q1 | Stairwell | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H8 | Sam Cracknell Pavilion | 01 | - | Balcony | Roof Covering (suspected beneath concrete pavers) | Bituminous Membrane (may be present beneath concrete pavers) | Suspected Positive | Non-friable | Low | P4 | Confirm potential presence of an asbestos membrane layer beneath concrete pavers and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | J14 | Keith Burrows Theatre | G | - | Exterior, North Side, (roof above northern section of Room G1), Lower Roof Membrane (suspected beneath upper roof membrane layer) | Roof Covering | Bituminous Membrane (may be present beneath new membrane) | Suspected Positive | Non-friable | Low | P4 | Confirm potential presence of an asbestos membrane layer beneath new membrane layer and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | J14 | Keith Burrows Theatre | 01 | - | Roof Space (access to roof space via door to Room GQ5) | Ductwork Flange Joints & Joins (beneath insulation and foil covering) | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm potential presence of an asbestos mastic sealant in duct flange joints and joins beneath insulation and foil covering and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | 01 | - | Exterior, Above 1Q8 | Roof Covering | Bituminous Membrane | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 2Q21 | Exterior, North-East Protruding Section | Roof Covering | Bituminous Membrane | Suspected Positive | Non-friable | Low | P4 | Confirm potential presence of an asbestos membrane layer and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 2Q22 | Exterior, Mid-West Protruding Section, Surrounding Former Roof | Roof Covering | Bituminous Membrane | Suspected Positive | Non-friable | Low | P4 | Confirm potential presence of an asbestos membrane layer and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 2Q22 | Exterior, Suspected Beneath Non-Asbestos Roof Covering | Roof Covering | Bituminous Membrane | Suspected Positive | Non-friable | Low | P4 | Confirm potential presence of an asbestos membrane layer beneath new membrane and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | 02 | 2Q24 | Exterior, Suspected Beneath Non-Asbestos Roof Covering & Concrete Pavers | Roof Covering | Bituminous Membrane | Suspected Positive | Non-friable | Low | P4 | Confirm potential presence of an asbestos membrane layer beneath new membrane and concrete pavers and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J12 | Newton | 2 | 2Q7 | Hallway, East | Fire Door | Insulation Core | Removed - Suspected Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 25 November 2019. Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | H13 | The Red Centre | R | RQ01 | Roof, Lift Motor Room | Lift Motors, Unit No. 65 & 66 (lift motor plate - installed 1996) | Lift Brake Pads | Suspected Positive | Non-friable | Low | P4 | Undertake sampling of lift brake pads under controlled conditions. If positive, remedial works should be undertaken by a Class A/B Contractor within a planned control program. | No |
Kenc | Kensington Campus | D10 | Building D10 | G | GQ1 | Throughout | Floor Covering | Vinyl Floor Tiles (black colour) | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 1 | - | Various Locations (102, 105, 106, 107, 109, 110, 111, 122, 123, 124, 125 & 1Q06) | Ductwork Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | C6 | International House | G | G89 | Inside Bulkhead Ceiling Space | Suspected Hot Water Pipework | Insulation | Suspected Positive | Friable | Low | P3 | Restrict access into bulkhead/ceiling space to authorised personnel only. Investigate and if asbestos insulation on pipes confirmed, remove under controlled conditions as part of a planned control program | No |
Kenc | Kensington Campus | C6 | International House | G | G90 | Inside Bulkhead Space | Suspected Hot Water Pipework | Insulation | Suspected Positive | Friable | Low | P3 | Restrict access into bulkhead/ceiling space to authorised personnel only. Investigate and if asbestos insulation on pipes confirmed, remove under controlled conditions as part of a planned control program | No |
Kenc | Kensington Campus | C6 | International House | G | GQ8 | Inside Bulkhead Ceiling Space | Suspected Hot Water Pipework | Insulation | Suspected Positive | Friable | Low | P3 | Restrict access into bulkhead/ceiling space to authorised personnel only. Investigate and if asbestos insulation on pipes confirmed, remove under controlled conditions as part of a planned control program | No |
Kenc | Kensington Campus | C6 | International House | 1 | 193 | Kitchen - Riser | Suspected Hot Water Pipework | Insulation | Suspected Positive | Friable | Low | P3 | Restrict access into riser to authorised personnel only. Investigate and if asbestos insulation on pipes confirmed, remove under controlled conditions as part of a planned control program | No |
Kenc | Kensington Campus | C6 | International House | 2 | 293 | Kitchen - Riser | Suspected Hot Water Pipework | Insulation | Suspected Positive | Friable | Low | P3 | Restrict access into riser to authorised personnel only. Investigate and if asbestos insulation on pipes confirmed, remove under controlled conditions as part of a planned control program | No |
Kenc | Kensington Campus | C6 | International House | 3 | 393 | Kitchen - Riser | Suspected Hot Water Pipework | Insulation | Suspected Positive | Friable | Low | P3 | Restrict access into riser to authorised personnel only. Investigate and if asbestos insulation on pipes confirmed, remove under controlled conditions as part of a planned control program | No |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | G | - | Exterior, Block H | Column | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | G | - | Exterior, Block G | Column | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | G | - | Exterior, Block F | Column | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | G | - | Exterior, Block E | Column | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | G | - | Exterior, Block D | Column | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | G | - | Exterior, Block C | Column | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | G | - | Exterior, Block B | Column | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | G | - | Exterior, Block A | Column | Moulded Fibre Cement | Negative | - | - | - | - | N/A |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | LG | - | Telephone MDF | Floor Penetrations Cover Panel | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANE | Randwick Environs | MA1 | Mulwaree Apartments | LG | - | Telephone MDF West | Floor Penetrations Cover Panel | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV15 | Administration 2 | G | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
MANV | Manly Vale | MV15 | Administration 2 | G | - | Kitchen | Sink Splashback | Sheet Vinyl (grey colour) | Assumed Negative | - | - | - | - | No |
MANV | Manly Vale | MV15 | Administration 2 | G | - | Exterior, Surrounding | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV2 | Administration | G | - | Exterior, Eastern & Western Sides | Gable Verge Lining (beneath terracotta roof tiles) | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MANV | Manly Vale | MV2 | Administration | G | - | Exterior, Surrounding | Eaves | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MANV | Manly Vale | MV2 | Administration | G | - | Exterior, Southern Side, Main Entrance | Awning Ceiling | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MANV | Manly Vale | MV2 | Administration | G | - | Exterior, Northern Side, Entrances x 2 | Awning Ceiling | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MANV | Manly Vale | MV2 | Administration | B | B04A | Foundation Space, Top of Piers | Packers | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MANV | Manly Vale | MV2 | Administration | B | BQ1 | From GQ3, Under Carpet | Floor Covering | Vinyl Tiles (grey colour) | Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
MANV | Manly Vale | MV2 | Administration | G | GQ3 | Stairs (to BQ1), Under Carpet | Floor Covering | Vinyl Tiles (grey colour) | Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
MANV | Manly Vale | MV2 | Administration | G | GQ1 | Electrical Cupboard off Corridor and Opposite Room G02 | Walls | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MANV | Manly Vale | MV2 | Administration | B | B05A | - | Floor Covering | Bituminous Membrane | Negative | - | - | - | - | Yes |
Kenc | Kensington Campus | D26 | Library | LG | - | Biolink, Exterior, Façade, | Between Window Frame & Glass | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Library | LG | - | Biolink, Exterior, Façade, | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MANV | Manly Vale | MV2 | Administration | B | B04 | Under Carpet | Floor Covering | Vinyl Tiles (green colour) | Positive (Removed) | - | - | - | Item removed 19/6/2012. Refer to NAA Clearance Certificate C107859:J111468. Note: Clearance states incorrect location of asbestos removal works. | Yes |
MANV | Manly Vale | MV2 | Administration | G | G24 | Under Carpet | Floor Covering | Vinyl Tiles (blue colour) | Assumed Negative | - | - | - | - | No |
MANV | Manly Vale | MV2 | Administration | G | G24a | Under Carpet | Floor Covering | Vinyl Tiles (blue colour) | Assumed Negative | - | - | - | - | No |
MANV | Manly Vale | MV2 | Administration | B | B04A | Foundation Space, Top of Wall | Unused Packer | Fibre Cement Sheeting | Assumed Positive (Removed) | - | - | - | Item Removed: RiskTech removed unused asbestos containing fibre cement packers as part of inspection & sampling in June 2018. | Yes |
MANV | Manly Vale | MV2 | Administration | B | B04A | Foundation Space, Ground Surfaces | Debris | Fibre Cement Sheeting | Assumed Positive (Removed) | - | - | - | Item Removed: RiskTech removed fibre cement debris as part of inspection & sampling in June 2018 | Yes |
MANV | Manly Vale | MV2 | Administration | B | B01 | Under Carpet | Floor Covering | Vinyl Tiles (yellow colour) | Assumed Positive (Removed) | - | - | - | Item removed 19/6/2012. Refer to NAA Clearance Certificate C107859:J111468. Note: Clearance states incorrect location of asbestos removal works. | Yes |
MANV | Manly Vale | MV2 | Administration | B | B02 | Under Carpet | Floor Covering | Vinyl Tiles (yellow colour) | Assumed Positive (Removed) | - | - | - | Item removed 19/6/2012. Refer to NAA Clearance Certificate C107859:J111468. Note: Clearance states incorrect location of asbestos removal works. | Yes |
MANV | Manly Vale | MV2 | Administration | B | B03 | Under Carpet | Floor Covering | Vinyl Tiles (yellow colour) | Assumed Positive (Removed) | - | - | - | Item removed 19/6/2012. Refer to NAA Clearance Certificate C107859:J111468. Note: Clearance states incorrect location of asbestos removal works. | Yes |
MANV | Manly Vale | MV2 | Administration | B | B01 | Under Carpet | Floor Covering | Vinyl Tiles (blue colour) | Assumed Positive (Removed) | - | - | - | Item removed 19/6/2012. Refer to NAA Clearance Certificate C107859:J111468. Note: Clearance states incorrect location of asbestos removal works. | Yes |
MANV | Manly Vale | MV2 | Administration | B | B02 | Under Carpet | Floor Covering | Vinyl Tiles (blue colour) | Assumed Positive (Removed) | - | - | - | Item removed 19/6/2012. Refer to NAA Clearance Certificate C107859:J111468. Note: Clearance states incorrect location of asbestos removal works. | Yes |
MANV | Manly Vale | MV2 | Administration | B | B03 | Under Carpet | Floor Covering | Vinyl Tiles (blue colour) | Assumed Positive (Removed) | - | - | - | Item removed 19/6/2012. Refer to NAA Clearance Certificate C107859:J111468. Note: Clearance states incorrect location of asbestos removal works. | Yes |
MANV | Manly Vale | MV2 | Administration | G | G24 | Wall Cavity (wall common to G24B) | On Wall | Bituminous Coating Material | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV2 | Administration | B | B05 | - | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV2 | Administration | G | G08 | - | Floor Covering | Sheet Vinyl | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV2 | Administration | G | G24B | - | Floor Covering | Vinyl Sheeting | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV2 | Administration | B | B02 | Under Carpet | Floor Covering | Vinyl Tiles (beige colour) | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV2 | Administration | B | B05 | Access Hatch | Foundation Pier Tops | Bituminous Material | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV2 | Administration | G | G14 | Server Room | Walls | Acoustic Wall Tile Adhesive | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV2 | Administration | G | G24B | - | Floor Covering | Vinyl Sheeting | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV2 | Administration | B | B05B | Under Carpet | Floor Covering | Vinyl Tiles (beige colour) | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV2 | Administration | G | GQ1 | Electrical Cupboard off Corridor and Opposite Room G02 | Walls | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | N/A |
MANV | Manly Vale | MV2 | Administration | B | - | - | Floor Covering | Bituminous Membrane | Negative | - | - | - | - | No |
MANV | Manly Vale | MV2 | Administration | G | GQ1 | Electrical Cupboard off Corridor and Opposite Room G02 | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
MANV | Manly Vale | MV2 | Administration | B | B04 | North-East Corner | Within Electrical Cabinet | Electrical Backing Board | Negative | Sse RiskTech inspection report dated Oct 2020 | N/A | |||
Kenc | Kensington Campus | D26 | Library | G | - | Biolink, Exterior, Façade, | Between Window Frame & Glass | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Library | G | - | Biolink, Exterior, Façade, | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MANV | Manly Vale | MV3A | Fuel Store | G | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
MANV | Manly Vale | MV6 | Store Room | G | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
MANV | Manly Vale | MV6 | Store Room | G | G01 | - | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | N13ABC | Baker Street Substations | G | - | Exterior | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | N13ABC | Baker Street Substations | G | - | Interior | No access (council owned) | - | - | - | - | - | - | N/A |
RANC | Randwick Campus | R13 | Randwick R13 | 01 | - | Exterior, East and West | Gable Ends | Profiled Fibre Cement Sheeting | Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R13 | Randwick R13 | 01 | 1Q2 | West Side, Above Entry, Surround Steel Beam | Infill Panels | Fibre Cement Sheeting | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R13 | Randwick R13 | G | G4 | Workshop, Electrical Cupboard | Conduit | Moulded Fibre Cement | Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R13 | Randwick R13 | G | - | Exterior, West, South & East, Above Blockwork Wall | Packing | Fibre Cement Sheeting | Positive (chrysotile) | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R13 | Randwick R13 | G | G1 | South & East, Above Blockwork Walls | Packing | Fibre Cement Sheeting | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R13 | Randwick R13 | G | G2 | South, Above Blockwork Wall | Packing | Fibre Cement Sheeting | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R13 | Randwick R13 | G | G3 | South & West, Above Blockwork Walls | Packing | Fibre Cement Sheeting | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R13 | Randwick R13 | G | G4 | South & East, Above Blockwork Walls | Packing | Fibre Cement Sheeting | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R13 | Randwick R13 | G | GQ1 | South & East, Above Blockwork Walls | Packing | Fibre Cement Sheeting | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R13 | Randwick R13 | 01 | - | Former Room M02 | Manhole Cover | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R13 | Randwick R13 | G | G4 | Workshop, South | Within Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R13 | Randwick R13 | 01 | - | Exterior, Throughout | Eaves | Fibre Cement Sheeting | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Library | 1 | - | Biolink, Exterior, Façade, Throughout | Between Window Frame & Glass | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Library | 1 | - | Biolink, Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G25 | Under Vinyl Floor Sheet | Floor Covering (suspected present beneath sheet vinyl) | Vinyl Floor Tiles (blue colour) | Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | EGQ01 | Electrical Cupboard | Floor Covering | Vinyl Floor Tiles (blue colour) Note: remnants present beneath cabinet | Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R2 | Randwick R2 | R | RQ01 | Loft, Surfaces Adjacent to Fire Wall | Debris | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item removed 1/9/2008. Refer to NAA Clearance Certificate 68273 and Air Monitoring Report 68273.001 | Yes |
RANC | Randwick Campus | R2 | Randwick R2 | R | RQ01 | Loft | Internal Fire Walls | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item removed 13/10/2012. Refer to NAA Clearance Certificate J113997 and Air Monitoring Report J113997.001. | Yes |
RANC | Randwick Campus | R2 | Randwick R2 | G | G25B | Under Vinyl Floor Sheet | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G25D | Under Vinyl Floor Sheet | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G25E | Under Vinyl Floor Sheet | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G26 | Under Vinyl Floor Sheet | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G12/ G13/ G14 | Under Carpet Tiles | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G21 | Under Carpet | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G22 | Under Vinyl Floor Sheet | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G23 | Under Vinyl Floor Sheet | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G25 | Under Vinyl Floor Sheet | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G10 | - | Floor Covering | Vinyl Floor Tiles (grey colour) | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G24 | - | Floor Covering | Vinyl Floor Tiles (grey colour) | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G24A | - | Floor Covering | Vinyl Floor Tiles (grey colour) | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G25C | Under Vinyl Floor Sheet | Floor Covering | Vinyl Floor Tiles (grey colour | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G25 | - | Floor Covering | Vinyl Tiles (blue colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G25B | Under Vinyl Floor Sheet | Floor Covering (suspected present beneath sheet vinyl) | Vinyl Floor Tiles (blue colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G25D | Under Vinyl Floor Sheet | Floor Covering (suspected present beneath sheet vinyl) | Vinyl Floor Tiles (blue colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Library | 2 | - | Biolink, Exterior, Façade, | Between Window Frame & Glass | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Library | 2 | - | Biolink, Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G25E | Under Vinyl Floor Sheet | Floor Covering (suspected present beneath sheet vinyl) | Vinyl Floor Tiles (blue colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G26 | Under Vinyl Floor Sheet | Floor Covering (suspected present beneath sheet vinyl) | Vinyl Floor Tiles (blue colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G12 | Under Carpet Tiles | Floor Covering | Vinyl Floor Tiles (blue colour) | Assumed Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G13 | Under Carpet Tiles | Floor Covering | Vinyl Floor Tiles (blue colour) | Assumed Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G14 | Under Carpet Tiles | Floor Covering | Vinyl Floor Tiles (blue colour) | Assumed Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G21 | Under Vinyl Floor Sheet | Floor Covering (suspected present beneath sheet vinyl) | Vinyl Floor Tiles (blue colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G22 | Under Vinyl Floor Sheet | Floor Covering (suspected present beneath sheet vinyl) | Vinyl Floor Tiles (blue colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G23 | Under Vinyl Floor Sheet | Floor Covering (suspected present beneath sheet vinyl) | Vinyl Floor Tiles (blue colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G01 | Under Vinyl Floor Sheet | Floor Covering (suspected present beneath sheet vinyl) | Vinyl Floor Tiles | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | EQ1 | Under Vinyl Floor Sheet | Floor Covering (suspected present beneath sheet vinyl) | Vinyl Floor Tiles | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R2 | Randwick R2 | G | G26 | Common to Room G26B | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R2 | Randwick R2 | G | G25A | East | Lower Wall (behind vinyl sheet) | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R2 | Randwick R2 | G | G26A | West | Lower Wall (behind vinyl sheet) | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R2 | Randwick R2 | G | - | Exterior, Throughout | Window Frames | Mastic Sealant | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R2 | Randwick R2 | G | - | Exterior, Throughout | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R2 | Randwick R2 | G | G26 | Under Vinyl Floor Sheet | Floor Covering | Vinyl Floor Tiles (blue/grey colour) | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R2 | Randwick R2 | G | G13 | - | Floor Covering | Vinyl Tiles (grey colour) | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R2 | Randwick R2 | G | G08 | Wall Strip | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R2 | Randwick R2 | G | EGQ01 | Electrical Cupboard | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R2 | Randwick R2 | R | RQ01 | Loft, North, Adjacent Fire Wall | Debris | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
Kenc | Kensington Campus | D26 | Library | 3 | - | Biolink, Exterior, Façade, | Between Window Frame & Glass | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Library | 3 | - | Biolink, Exterior, Façade, | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R2 | Randwick R2 | R | RQ01 | Loft, North | Internal Fire Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R2 | Randwick R2 | G | - | Exterior | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R2 | Randwick R2 | G | G06 | Adjacent Communications Cupboard | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R3 | Randwick R3 | G | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
RANC | Randwick Campus | R3 | Randwick R3 | G | - | Exterior, Front and Rear Entrance | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R7 | Randwick R7 | G | - | Exterior, To Supports | Packer | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R7 | Randwick R7 | G | - | Exterior, Throughout | Window Frames | Mastic Sealant | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R7 | Randwick R7 | G | - | Kitchen, Windows | Access Hatch | Sash Cords | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R7 | Randwick R7 | G | - | Exterior, North | Within Electrical Cabinet | Electrical Backing Board | Positive (chrysotile) | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | SM | SM47 | Electrical Cupboard, Adjacent Room SM37 | Walls, Ceiling & Door Lining | Fibre Cement Sheeting | Positive | Non-Friable | Low | P3 | Remove ceiling under controlled conditions by a Class A/B contractor as part of a planned program of works or prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | M14 | - | Ceiling | Fibre Cement Sheeting | Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | M14A | - | Ceiling | Fibre Cement Sheeting | Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | M01 | - | Floor Covering | Vinyl Floor Tiles (green colour) | Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G07B | - | Redundant Drive Belt Equipment | Gasket | Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G37 | Toilet | Ceiling | Fibre Cement Sheeting | Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G37A | Toilet | Ceiling | Fibre Cement Sheeting | Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G21C | Interior, Southern Façade, 4th Bay from Western End | Timber Wall Framework (around nail heads) | Fibre Cement Sheet Remnants | Positive (chrysotile) | Non-Friable | Med | P3 | Remove under controlled conditions by a licensed asbestos contractor as part of a planned program of works or prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | M08 | - | Safe | Insulation (behind metal casing) | Suspected Positive | Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | Yes |
RANC | Randwick Campus | R9 | Tramshed | M | M10A | - | Furnace | Insulation | Positive (Removed) | - | - | - | Item removed 9/5/2015. Refer to Greencap Clearance Certificate and Air Monitoring Report C107859:J133139. | Yes |
Kenc | Kensington Campus | D26 | Library | 4 | - | Biolink, | Between Window Frame & Glass | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Library | 4 | - | Biolink, | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G28 | - | Fire Door | Core Insulation | Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
RANC | Randwick Campus | R9 | Tramshed | G | G13 | - | Floor Covering | Vinyl Floor Tiles (brown colour) | Positive (Removed) | - | - | - | Item removed 1/6/2012. Refer to NAA Clearance Certificate J105057 and Air Monitoring Report J105057.009. | Yes |
RANC | Randwick Campus | R9 | Tramshed | G | G14 | Within Floor Duct | Debris | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item removed 1/6/2012. Refer to NAA Clearance Certificate J111636 and Air Monitoring Report J111636.001. | Yes |
RANC | Randwick Campus | R9 | Tramshed | G | GQ3 | - | Fire Door | Core Insulation | Positive (Removed) | - | - | - | Item removed 9/5/2015. Refer to Greencap Clearance Certificate and Air Monitoring Report C107859:J133139. | Yes |
RANC | Randwick Campus | R9 | Tramshed | G | GQ4 | - | Fire Door | Core Insulation | Positive (Removed) | - | - | - | Item removed 9/5/2015. Refer to Greencap Clearance Certificate and Air Monitoring Report C107859:J133139. | Yes |
RANC | Randwick Campus | R9 | Tramshed | G | G07C1 | On Floor | Debris | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item removed 1/6/2007. Refer to NAA Clearance Certificate 57649. | Yes |
RANC | Randwick Campus | R9 | Tramshed | M | MQ2 | Fire Stairs | Fire Door | Core Insulation | Positive (Removed) | - | - | - | Item removed 9/5/2015. Refer to Greencap Clearance Certificate and Air Monitoring Report C107859:J133139. | Yes |
RANC | Randwick Campus | R9 | Tramshed | G | G29A | Floor Surfaces | Debris | Fibre Cement Sheeting | Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
RANC | Randwick Campus | R9 | Tramshed | M | M11 | West | Fume Cupboard Lining | Fibre Cement Sheeting | Positive (chrysotile & amosite) | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G39 | - | Ceiling | Fibre Cement Sheeting | Positive (chrysotile & amosite) | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | M06A | Laboratory | Floor Lining | Compressed Fibre Cement Sheeting | Positive (Chrysotile) | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | SM | SM41 | - | Floor Covering | Vinyl Floor Tiles (cream colour) | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R9 | Tramshed | SM | SM41 | - | Floor Covering | Vinyl Floor Tiles (brown colour) | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R9 | Tramshed | SM | SM31 | - | Floor Covering | Vinyl Floor Tiles (green colour) | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R9 | Tramshed | G | G08 | - | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R9 | Tramshed | G | G05B1 | - | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R9 | Tramshed | G | G05B1 | - | Wall | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R9 | Tramshed | G | G05B2 | - | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R9 | Tramshed | G | G05B2 | - | Wall | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R9 | Tramshed | G | GQ3 | - | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
Kenc | Kensington Campus | D26 | Library | 5 | - | Biolink, Exterior, Façade, Throughout | Between Window Frame & Glass | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D26 | Library | 5 | - | Biolink, Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | GQ3 | - | Wall | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
RANC | Randwick Campus | R9 | Tramshed | M | M13B | - | Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | M01A | Floor Covering | Vinyl Floor Tiles (green colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No | |
RANC | Randwick Campus | R9 | Tramshed | M | M01B | Floor Covering | Vinyl Floor Tiles (green colour) | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No | |
RANC | Randwick Campus | R9 | Tramshed | G | G07C1 | - | Wall | Fibre Cement Sheeting | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G39 | - | Ceiling Vent Infill Panels | Fibre Cement Sheeting | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | SM | SM47 | - | Debris | Fibre Cement Sheeting | Assumed Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
RANC | Randwick Campus | R9 | Tramshed | SM | SM47 | - | Floor Covering | Vinyl Floor Tiles (cream colour) | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | SM | SM47 | - | Floor Covering | Vinyl Floor Tiles (brown colour) | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | SM | SMQ1 | - | Floor Covering | Vinyl Floor Tiles (green colour) | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | SM | SM30 | - | Floor Covering | Vinyl Floor Tiles (brown colour) | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | M | MQ1 | Under Carpet | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | M | M01 | - | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | G | G13 | - | Floor Covering | Adhesive | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | G | GQ4 | - | Floor Covering | Vinyl Floor Tiles (grey colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | - | Exterior, Façade | Wall Expansion Joints | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status of mastic sealant to façade expansion joints under controlled conditions and if positive, consider removal under controlled conditions by a Class A/B contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | - | Exterior, Façade | Façade Spandrel Panel Brackets (within concrete panels) | Insulation | Suspected Positive | Friable | Low | P3 | Confirm status of insulation material to spandrel brackets under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | - | Exterior, Façade | Wall Expansion Joints | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status of mastic sealant to façade expansion joints under controlled conditions and if positive, consider removal under controlled conditions by a Class A/B contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | - | Exterior, Façade | Façade Spandrel Panel Brackets (within concrete panels) | Insulation | Suspected Positive | Friable | Low | P3 | Confirm status of insulation material to spandrel brackets under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | - | Exterior, Façade | Wall Expansion Joints | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status of mastic sealant to façade expansion joints under controlled conditions and if positive, consider removal under controlled conditions by a Class A/B contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | - | Exterior, Façade | Façade Spandrel Panel Brackets (within concrete panels) | Insulation | Suspected Positive | Friable | Low | P3 | Confirm status of insulation material to spandrel brackets under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | - | Exterior, Façade | Wall Expansion Joints | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status of mastic sealant to façade expansion joints under controlled conditions and if positive, consider removal under controlled conditions by a Class A/B contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | - | Exterior, Façade | Façade Spandrel Panel Brackets (within concrete panels) | Insulation | Suspected Positive | Friable | Low | P3 | Confirm status of insulation material to spandrel brackets under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | - | Exterior, Façade | Wall Expansion Joints | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status of mastic sealant to façade expansion joints under controlled conditions and if positive, consider removal under controlled conditions by a Class A/B contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | - | Exterior, Façade | Façade Spandrel Panel Brackets (within concrete panels) | Insulation | Suspected Positive | Friable | Low | P3 | Confirm status of insulation material to spandrel brackets under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | - | Exterior, Façade | Wall Expansion Joints | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status of mastic sealant to façade expansion joints under controlled conditions and if positive, consider removal under controlled conditions by a Class A/B contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | - | Exterior, Façade | Façade Spandrel Panel Brackets (within concrete panels) | Insulation | Suspected Positive | Friable | Low | P3 | Confirm status of insulation material to spandrel brackets under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | - | Exterior, Façade | Windows (between frame and façade wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | - | Exterior, Façade | Wall Expansion Joints | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status of mastic sealant to façade expansion joints under controlled conditions and if positive, consider removal under controlled conditions by a Class A/B contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | - | Exterior, Façade | Wall Expansion Joints | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status of mastic sealant to façade expansion joints under controlled conditions and if positive, consider removal under controlled conditions by a Class A/B contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | - | Exterior, Façade | Façade Spandrel Panel Brackets (within concrete panels) | Insulation | Suspected Positive | Friable | Low | P3 | Confirm status of insulation material to spandrel brackets under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | - | Exterior, Façade | Wall Expansion Joints | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status of mastic sealant to façade expansion joints under controlled conditions and if positive, consider removal under controlled conditions by a Class A/B contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | - | Exterior, Façade | Façade Spandrel Panel Brackets (within concrete panels) | Insulation | Suspected Positive | Friable | Low | P3 | Confirm status of insulation material to spandrel brackets under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | - | Exterior, Façade | Wall Expansion Joints | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status of mastic sealant to façade expansion joints under controlled conditions and if positive, consider removal under controlled conditions by a Class A/B contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | - | Exterior, Façade | Façade Spandrel Panel Brackets (within concrete panels) | Insulation | Suspected Positive | Friable | Low | P3 | Confirm status of insulation material to spandrel brackets under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F21 | Library | 1 | 111 | - | Fire Door (no tag) | Core Insulation | Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 1 | 1Q1 | Fire Stairs | Fire Doors | Core Insulation | Suspected Positive | Friable | Low | P3 | Remove under controlled conditions by a Class A contractor as part of a planned control program. (No access to confirm tag on doors - alarmed). | No |
KENC | Kensington Campus | F21 | Library | 1 | 1Q2 | Fire Stairs | Sliding Fire Door ('Padde - Fire Control Pty Ltd') | Core Insulation | Positive (chrysotile & amosite) | Friable | Low | P3 | Item removed- Refer to Risktech Clearance Certificate dated 13/05/2024 | Yes |
KENC | Kensington Campus | F21 | Library | 1 | E1Q01 | Electrical Room off Fire Stairs (1Q12) | Fire Door (tagged ' Bismac Fire Doors, 2022') | Core Insulation | Suspected Negative | - | - | - | - | Yes |
KENC | Kensington Campus | F21 | Library | 2 | - | Exterior, Old Low Rise Northern Brick Section, Perimeter Awning Roof Areas | Roof Covering | Bituminous Membrane | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 3 | - | Exterior, Old Low Rise Northern Brick Section, Perimeter Awning Roof Areas | Roof Covering | Bituminous Membrane | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 4 | 4Q3 | Fire Stairs | Sliding Fire Door ('Padde - Fire Control Pty Ltd') | Core Insulation | Positive (chrysotile & amosite) | Friable | Low | P3 | Item removed- Refer to Risktech Clearance Certificate dated 13/05/2024 | Yes |
KENC | Kensington Campus | F21 | Library | 4 | 4Q8 | Fire Stairs | Sliding Fire Door ('Padde - Fire Control Pty Ltd') | Core Insulation | Positive (chrysotile & amosite) | Friable | Low | P3 | Item removed- Refer to Risktech Clearance Certificate dated 13/05/2024 | Yes |
KENC | Kensington Campus | F21 | Library | 4 | - | Exterior, Old Low Rise Northern Brick Section, Perimeter Awning Roof Areas | Roof Covering | Bituminous Membrane | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 5 | - | Roof, Northern Section of New Tower Building, Surrounding Drain Holes | Roof Covering (beneath new membrane) | Bituminous Membrane | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 15 | 1501 | Plant Room | Hot Water Pipework, Flange Joints | Gaskets | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 15 | 15Q5 | Plant Room | Water Tanks - Panel Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 181 | Substation No.10 | Within & Below Concrete Floor Slab (beneath metal sheet floor cover), Conduits | Moulded Fibre Cement Pipes | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 18 | 1802 | - | Water Tank - Panel Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | G15 | Robert Webster Theatres | 01 | 1Q10 | Fire Exit | Fire Doors (tagged 'Wormald, 20--') | Core Insulation | Suspected Negative | - | - | - | - | No |
Kenc | Kensington Campus | G15 | Robert Webster Theatres | 02 | 2Q9 | Fire Exit | Window Frames (Between Frame and Pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | - | Exterior, Surrounding | Wall Expansion Joints | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status of mastic sealant to façade expansion joints under controlled conditions and if positive, consider removal under controlled conditions by a Class A/B contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 1 | - | Surrounding | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Confirm status of insulation material to spandrel brackets under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | - | Exterior, Surrounding | Wall Expansion Joints | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status of insulation material to spandrel brackets under controlled conditions and if positive, consider removal under controlled conditions by a Class A/B contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 2 | - | Surrounding | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Confirm status of insulation material to spandrel brackets under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | - | Exterior, Surrounding | Wall Expansion Joints | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status of mastic sealant to façade expansion joints under controlled conditions and if positive, consider removal under controlled conditions by a Class A/B contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 3 | - | Surrounding | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Confirm status of insulation material to spandrel brackets under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | - | Exterior, Surrounding | Wall Expansion Joints | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status of mastic sealant to façade expansion joints under controlled conditions and if positive, consider removal under controlled conditions by a Class A/B contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | - | Surrounding | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Confirm status of insulation material to spandrel brackets under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 4 | 410A | Entrance | Fire Door (no tag) | Core Insulation | Suspected Positive | Friable | Low | P3 | Confirm status of core insulation material in fire door under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | - | Exterior, Surrounding | Wall Expansion Joints | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status of mastic sealant to façade expansion joints under controlled conditions and if positive, consider removal under controlled conditions by a Class A/B contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 5 | - | Surrounding | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Confirm status of insulation material to spandrel brackets under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | - | Exterior, Surrounding | Wall Expansion Joints | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status of mastic sealant to façade expansion joints under controlled conditions and if positive, consider removal under controlled conditions by a Class A/B contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 6 | - | Surrounding | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Confirm status of insulation material to spandrel brackets under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | - | Exterior, Surrounding | Wall Expansion Joints | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status of mastic sealant to façade expansion joints under controlled conditions and if positive, consider removal under controlled conditions by a Class A/B contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | H20 | Civil Engineering | 7 | - | Surrounding | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Confirm status of insulation material to spandrel brackets under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | - | Pool (B4), Exterior, South, Near South West Corner | Within Electrical Cabinet | Electrical Backing Board | Removed - Suspected Positive | - | - | - | Item Removed: No removal/clearance documentation provided. | Yes |
Kenc | Kensington Campus | M15 | Rupert Myers | R | 6001/ 6002 | Lift Motor Room | Lift Motors (Note: New lift motors installed 2018) | Brake Pads | Suspected Negative | - | - | - | - | No |
KENE | Kensington Environs | O14 | Kangas House | G | GQ01 | Exterior, Electrical Cupboard | Inside Electrical Cabinets | Electrical Backing Boards | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | O14 | Kangas House | G | GQ02 | Exterior, Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Boards | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | O14 | Kangas House | G | 12 | Electrical Cupboard | Inside Electrical Cabinets | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G07A | South | Fence | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | G | G08 | - | Wall | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSH | Hay Field Station | HFS6 | Hay Field Station Quarantine Shed | G | G01 | Eastern End, Outside Room G01B | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | GQ2 | Corridor, South Side, East End | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS7 | Hay Field Station Quarters | G | - | Exterior, South | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | UCA | Exterior, Northern Side, NW Corner, Uncovered Awning Area | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
RANC | Randwick Campus | R9 | Tramshed | G | GQ3 | - | Expansion Joint | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | P09 | Pool (B4), South, South West Corner | Within Wall Recessed Electrical / Comms Cabinets x 2 | Electrical Backing Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | P10 | Pool (B4), North | Within Electrical Cabinets | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status and if contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | C6 | International House | G | G99 | East Corridor, Outside Room G99, Electrical Switchboard Cupboard, Above, Within & Below Ground Slab | Service Conduit | Moulded Fibre Cement Pipe | Positive (chrysotile, amosite & crocidolite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | C6 | International House | G | - | Exterior, Eastern Side, Near SE Corner Entrance | Gas Meter | Gaskets | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | D16 | Goldstein Hall | G | GQ13 | Main Switch Room | Cable Pit | Bituminous Cable Wrap Insulation | Suspected Positive | Non-friable | Low | P4 | Confirm status and if contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G40 | - | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | G | G07C | Floor | Expansion Joint | Bituminous Material | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | G | G21D | South of G32 | Workbench Covering | Sheet Vinyl (green colour) | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | G | G21E | Adjacent Room G25, Above Electrical Distribution Cabinet ' R9-DB-G09' | Within Flash Guards (fuses) | Woven Insulation | Suspected Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | M01B | South | Within Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | M22 | East, Distribution Board Cabinets 'R9-DB-M01(M13)' & 'R9-DB-M02 (M13)' | Within Electrical Cabinet | Electrical Backing Board | Negative | - | - | - | Cover on Electrical Cabinets Removed by Stowe on 18/12/2023. No Asbestos Electrical Backing Board(s) identified in Cabinets. | No |
Kenc | Kensington Campus | D9 | IO Myers Studio | G | G08 | South | Inside Electrical Distribution Board Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Removed under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | Yes |
Kenc | Kensington Campus | D9 | IO Myers Studio | 01 | 1Q1 | South-West | Inside Electrical Distribution Board Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Removed under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | Yes |
KENC | Kensington Campus | F21 | Library | LG | LG4 | Substation 11 | Inside Electrical Cabinets | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | LG | LGQ01 | Boiler Room | Inside Electrical Cabinet | Electrical Backing Board | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | LG | - | South West Plant Room, | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | 130A | Plant Room | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | 1Q12 | Electrical Room off Fire Stairs (1Q12) | Inside Old Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 2 | 216 | Electrical Cupboard Adjacent Fire Stairs (2Q4) | Inside Electrical Cabinets | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 2 | E2Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 232) | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 3 | 305 | Electrical Room Adjacent Fire Stairs (3Q2) | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 3 | E3Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 318) | Inside Electrical Cabinets | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 4 | E4Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 401) | Inside Electrical Cabinets | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 4 | E4Q02 | Electrical Cupboard Adjacent Fire Stairs (4Q8) | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 5 | E5Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 501) | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 6 | E6Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 601) | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 7 | E7Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 701) | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 8 | E8Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 801) | Inside Electrical Cabinets | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 9 | E9Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 901) | Inside Electrical Cabinets | Electrical Backing Boards | Removed -Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New electrical cabinets) | No |
KENC | Kensington Campus | F21 | Library | 10 | E10Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 1001) | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 11 | E11Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 11Q1) | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 12 | E12Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 12Q4) | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 13 | E13Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 13Q4) | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 14 | E14Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 14Q3) | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 15 | 1501 | Plant Room, Inside NW Air Handling Unit | Air Conditioning Ductwork Heater Unit | Insulation Board | Removed - Positive (chrysotile & amosite) | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 17 May 2021. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 179 | Sprinkler Pump Room | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 305A | Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q2 | Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q1 | Electrical Cupboard | Inside Electrical Cabinet (new appearance cabinet) | Electrical Backing Board | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 6Q1 | Opposite Room 609, Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 7Q9 | Plant Room (previously Room 727) | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 9Q1 | Opposite Room 911, Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 11Q1 | Opposite Room 1108 Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 12Q1 | Opposite Room 1210, Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | 13Q1 | Opposite Room 1309, Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | E15Q 01 | Opposite Room 1505A, Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | E16Q 01 | Opposite Room 1608, Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | 4 | 408 | Lift Motor Room (No.15) | Lift Motors | Brake Pads | Suspected Positive | Non-friable | Low | P4 | Undertake sampling of lift brake pads under controlled conditions. If positive, remedial works should be undertaken by a Class A/B Contractor within a planned control program. | N/A |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 105 | - | Air Conditioning Ductwork Heater Bank | Insulation Board | Assumed Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 1Q04 | Corridor, Ceiling Space | Air Conditioning Ductwork Heater Bank | Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G6 | Blockhouse | 1 | M1Q01 | Plant Room | Inside Electrical Cabinet | Electrical Backing Boards | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 219 | Ceiling Space / Bulkhead | Air Conditioning Ductwork Heater Bank (EDH 1) | Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 2Q04 | Corridor, Ceiling Space | Air Conditioning Ductwork Heater Bank | Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 01 | Sub 12 | Substation 12 | Within Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 01 | Sub 12 | Substation 12 | Conduit | Moulded Fibre Cement | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 7 | 703 | Lift Motor Room | Lift Motors - Unit No.42 | Brake Pads | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | SM | SM47 | Electrical Cupboard, Adjacent Room SM37 | Within Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | M06 | North-East | Furnace | Insulation | Suspected Positive (Removed) | - | - | - | Item removed 9/5/2015. Refer to Greencap Clearance Certificate and Air Monitoring Report C107859:J133139. | Yes |
RANC | Randwick Campus | R9 | Tramshed | G | G29A | Testing Station | Ceiling | Fibre Cement Sheeting | Suspected Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
RANC | Randwick Campus | R9 | Tramshed | G | G29B | - | Soffit | Fibre Cement Sheeting | Suspected Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
RANC | Randwick Campus | R9 | Tramshed | G | G15 / G16 | On Top of Ceiling | Air Conditioning Duct Heater Unit | Insulation Board | Suspected Positive (Removed) | - | - | - | Item removed 21/3/2015 by Beasy Pty Ltd. Refer to Greencap Clearance and Air Monitoring Reports (ref:C111395:J131388). | Yes |
RANC | Randwick Campus | R9 | Tramshed | G | G20 | On Top of Ceiling | Air Conditioning Duct Heater Unit | Insulation Board | Suspected Positive (Removed) | - | - | - | Item removed 21/3/2015 by Beasy Pty Ltd. Refer to Greencap Clearance and Air Monitoring Reports (ref:C111395:J131388). | Yes |
RANC | Randwick Campus | R1 | Randwick R1 | G | G50 | Plant Room, North Side, Distribution Board No.2 Cabinet | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | A27 | Golf House | G | - | Exterior, East, Adjacent Entrance | Within Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B contractor prior to demolition or refurbishment. | No |
FSFG | Fowlers Gap Field Station | FG14 | Fowlers Gap Laboratory | G | G06 | Mid-North Office, North Side | Within Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENC | Kensington Campus | E4 | Squarehouse | G | GQ9 | Plant Room | Ductwork Heater Bank | Millboard Insulation | Suspected Positive | Friable | Low | P3 | 'Undertake sampling under controlled, de-energised conditions. If positive, remedial works should be undertaken by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | E4 | Squarehouse | G | GQ13 | Plant Room | Ductwork Heater Bank | Millboard Insulation | Negative | - | - | |||
KENC | Kensington Campus | F22 | Bank | 2 | 213 | - | Air Conditioning Ductwork Heater Units | Insulation Board | Removed - Positive (chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 31 January 2020. Removed by Pure Contracting. | Yes |
FSSL | Smiths Lake Field Station | SL2 | Smiths Lake Toilet Shower Block | G | G2 | - | Cubicle Partitions | Compressed Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENE | Kensington Environs | AS2 | 2 Arthur Street | G | - | Exterior, North-East, Surrounding Air Conditioning Unit | Infill Panel | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS20 | 20 Arthur Street | G | - | Front Entrance, West | Within Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSSL | Smiths Lake Field Station | SL2 | Smiths Lake Toilet Shower Block | G | G2 | - | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
MANV | Manly Vale | MV8 | Well Testing Laboratory | B | B01 | - | Within Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
FSFG | Fowlers Gap Field Station | FG3 | Fowlers Gap Shearing Shed | G | G01 | South Side | Within Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENC | Kensington Campus | F22 | Bank | 2 | 213 | - | Ductwork Joints & Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F22 | Bank | 2 | - | Roof Space | Ductwork Joints & Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | LG | LGQ01 | Boiler Room | Hot Water Pipework, Flange Joints | Gaskets | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 2 | 243 | Cleaners Room | Old Ductwork Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status of suspected asbestos material and if confirmed to contain asbestos, remove under controlled conditions by a licensed Class A/B asbestos contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | F21 | Library | 6 | RQ01 | Roof | Roof Covering (assumed beneath new membrane or concrete toppings) | Bituminous Membrane | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
FSH | Hay Field Station | HFS8 | Hay Field Station Managers Office | G | - | Exterior, All Sides | Walls (behind metal cladding) | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Further investigation should be undertaken to confirm presence and extent of potential asbestos containing fibre cement wall sheeting behind the metal exterior wall cladding prior to demolition or refurbishment works. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 182 | - | Air Handling Unit, Panel Joins | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | C6 | International House | - | - | Exterior, Western Section | Eaves | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed to contain asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
Kenc | Kensington Campus | C6 | International House | - | - | Exterior, Northern Side, NE Section | Infill Wall Panelling | Fibre Cement Sheeting | Removed - Positive (chrysotile & amosite) | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 30 August 2024. Removed by Pure Contracting. | Yes |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 01 | - | Exterior, East | Balcony Awning Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | - | Gymnasium (B5), Exterior Throughout | Eaves | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status and if contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | - | Gymnasium (B5), Exterior, Northern Entrance | Fascia | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status and if contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | - | Gymnasium (B5), Exterior, North and South Elevations | Vertical Expansion Joint between Brickwork and Concrete Columns | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status and if contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 02 | - | Gymnasium (B5), Exterior Throughout | Eaves | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status and if contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
FSSL | Smiths Lake Field Station | SL2 | Smiths Lake Toilet Shower Block | G | G2 | - | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | M | - | Exterior, Northwest Corner Adjacent Entrance, North Side of Room M17 | Eaves | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Confirm status. If positive, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | 1 | - | Exterior, Eastern Façade | Eaves | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 02 & 03 | - | Exterior | Eaves | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
FSSL | Smiths Lake Field Station | SL2 | Smiths Lake Toilet Shower Block | G | - | Exterior, South | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K14 | Physics Theatre | LG-01 | - | Exterior | Eaves | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | AS14 | 14 Arthur Street | G | - | Exterior, North | Gable | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS2 | 2 Arthur Street | G | - | Exterior, North | Gable | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS2 | 2 Arthur Street | G | - | Exterior, Rear, East | Gable | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS24 | 24 Arthur Street | G | - | Exterior, East, Above Entrance Awning | Infill Panels | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS24 | 24 Arthur Street | G | - | Roof | Gable Verge Lining | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS4 | 4 Arthur Street | G | - | Exterior, Front, North | Gable | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS8 | 8 Arthur Street | G | - | Exterior, Roof | Chimney Capping | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | HS46 | 46 High Street | 03 | - | Throughout | Eaves | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status and if confirmed to contain asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | HS46 | 46 High Street | 03 | - | North & South | Gable Ends | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status and if confirmed to contain asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | HS46 | 46 High Street | 03 | - | Roof Throughout | Gable Verge Lining | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status and if confirmed to contain asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | WR41 | 41 Wansey Road | G | - | Exterior, West | Gable | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSSL | Smiths Lake Field Station | SL2 | Smiths Lake Toilet Shower Block | G | G1 | - | Cubicle Partitions | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | BS34 | 34 to 36 Botany Street | G | - | Exterior, East | Gable Wall Panelling | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status and if confirmed to contain asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | LG | LG06D | East | Floor Covering | Vinyl Tiles (grey mottled) | Suspected Positive | Non-friable | Low | P4 | Confirm status of vinyl floor tiles and if asbestos present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment | No |
FSSL | Smiths Lake Field Station | SL2 | Smiths Lake Toilet Shower Block | G | G1 | - | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q06 | Fire Exit | Fire Door | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | G06A/G06B/G07/G07A | Gymnasium (B5), Toilets | Window Frames (between frame and pane) | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status and if contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENE | Kensington Environs | AS24 | 24 Arthur Street | G | - | Exterior, East & West | Gable (behind textured coating) | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENE | Kensington Environs | AS24 | 24 Arthur Street | G | - | Exterior, East & West | Eaves | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENC | Kensington Campus | F23 | Mathews Building | 17 | RQ01 | Western Roof Section | Roof (beneath concrete pavers, new membrane and/or plinths) | Bituminous Membrane | Suspected Positive | Non-friable | Low | P4 | RM Watson advised that new membrane was installed late 2018 to early 2019 and that no asbestos containing membrane was present. Further investigation should be undertaken prior to demolition or refurbishment. | No |
FSSL | Smiths Lake Field Station | SL2 | Smiths Lake Toilet Shower Block | G | G1 | - | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
FSSL | Smiths Lake Field Station | SL2 | Smiths Lake Toilet Shower Block | G | - | Throughout | No asbestos materials Identified | - | - | - | - | - | - | N/A |
KENC | Kensington Campus | J12 | Newton | G | G14 | Room WG8, Central | Portable Steps | Vinyl Tiles | Suspected Positive | - | - | - | Item Removed: No removal documentation provided | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | - | Exterior, North Side, Outside Room LG28 | Windows (between frame and pane) | Mastic Sealant | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | AS20 | 20 Arthur Street | G | - | Garage, Surfaces Beneath Roof | Settled Dust | Dust and Debris | Suspected Positive | Friable | Med | P3 | Further investigation should be undertaken prior to disturbance of any surfaces below the asbestos roof. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G9 | - | Floor Covering | Vinyl Floor Tiles (suspected beneath vinyl sheeting) | Suspected Positive | Non-friable | Low | P4 | Confirm presence and status of vinyl floor tiles beneath vinyl sheeting prior to renovations or demolition. If confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G20 | - | Floor Covering | Vinyl Floor Tiles (suspected beneath carpet) | Suspected Positive | Non-friable | Low | P4 | Confirm presence and status of vinyl floor tiles beneath carpet prior to renovations/demolition. If confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. Note: No vinyl floor tiles observed beneath carpet, where inspected. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G24 | - | Floor Covering | Vinyl Floor Tiles (suspected beneath vinyl sheeting) | Suspected Positive | Non-friable | Low | P4 | Confirm presence and status of vinyl floor tiles beneath vinyl sheeting prior to renovations or demolition. If confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G25 | - | Floor Covering | Vinyl Floor Tiles (suspected beneath carpet / vinyl sheeting and masonite) | Suspected Positive | Non-friable | Low | P4 | Confirm presence and status of vinyl floor tiles beneath carpet / vinyl sheeting and masonite sheeting prior to renovations/demolition. If confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | G | G26A | - | Floor Covering | Vinyl Floor Tiles (suspected beneath vinyl sheeting) | Suspected Positive | Non-friable | Low | P4 | Confirm presence and status of vinyl floor tiles beneath vinyl sheeting prior to renovations or demolition. If confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | - | Tower Section, Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets or Other Elements | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 2 | - | Tower Section, Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets or Other Elements | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 3 | - | Tower Section, Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets or Other Elements | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 4 | - | Tower Section, Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets or Other Elements | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 5 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets or Other Elements | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 6 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets or Other Elements | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 7 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets or Other Elements | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 8 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets or Other Elements | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 9 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets or Other Elements | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 10 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets or Other Elements | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 11 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets or Other Elements | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 12 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets or Other Elements | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 13 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets or Other Elements | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 14 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets or Other Elements | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 1 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 2 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 4 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 5 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 6 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 7 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 8 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 10 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 13 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 14 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | - | Perimeter Façade Walls (behind wall panelling below / above windows) | Façade Spandrel Panel Brackets | Insulation | Suspected Positive | Friable | Low | P3 | Conduct investigation to confirm presence and extent of asbestos materials and if confirmed present, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 6 | 6Q04 | Fire Exit | Fire Door | Core Insulation | Suspected Positive | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 7 | 7Q01 | Fire Exit | Fire Door | Core Insulation | Suspected Positive | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
KENC | Kensington Campus | F20 | Goodsell | Roof | R1 | Former Lift Motor Room | Inside Switchboard Controller Cabinet | Brake Pad Linings | Suspected Positive - Removed | - | - | - | Item Removed: Prior to 2014 inspection. No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F20 | Goodsell | Roof | R1 | Former Lift Motor Room | Lift Motor | Brake Pad Linings | Suspected Positive - Removed | - | - | - | Item Removed: Prior to 2014 inspection. No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 16 | 1604 | Lift Motor Room | Lift Motors | Brake Pads | Removed -Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New lift motors) | Yes |
KENC | Kensington Campus | F21 | Library | 16 | 1604 | Lift Motor Room | Inside Switchboard Lift Controller / Electrical Cabinet | Electrical Backing Board | Removed -Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New switchboard lift controller & electrical cabinets) | Yes |
KENC | Kensington Campus | F21 | Library | 16 | 1604 | Lift Motor Room | Inside Switchboard Lift Controller Cabinets | Arc Shields | Removed -Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New switchboard lift controller & electrical cabinets) | Yes |
FSSL | Smiths Lake Field Station | SL7 | Smiths Lake Old Students Quarters | G | UGQ1 | Exterior, South | Eaves | Fibre Cement Sheeting | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
FSSL | Smiths Lake Field Station | SL7 | Smiths Lake Old Students Quarters | G | UGQ1 | Exterior, East & West, Between Timber Roof Supports & Above Horizontal Infill Strips | Packing | Fibre Cement Sheeting | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment works. | No |
KENC | Kensington Campus | F21 | Library | 14 | - | Former Hoist Room Adjacent Goods Lift | Fire Panel (tagged 'Millott Fire Door Unit - Year 1975') | Core Insulation | Removed -Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
FSSL | Smiths Lake Field Station | SL7 | Smiths Lake Old Students Quarters | G | UGQ1 | Exterior, East & West | Upper Walls, Horizontal Infill Strip | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
FSSL | Smiths Lake Field Station | SL7 | Smiths Lake Old Students Quarters | G | UGQ1 | North | Upper Infill Wall Panelling (above metal sheet wall) | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSSL | Smiths Lake Field Station | SL8 | Smiths Lake Old Students Quarters | G | - | Throughout | No asbestos materials Identified | - | - | - | - | - | - | N/A |
FSSL | Smiths Lake Field Station | SL9 | Smiths Lake Old Students Quarters | G | G2 | Central Room | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
FSSL | Smiths Lake Field Station | SL9 | Smiths Lake Old Students Quarters | G | G1 | Eastern Room | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
FSSL | Smiths Lake Field Station | SL9 | Smiths Lake Old Students Quarters | G | G3 | Western Room | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSSL | Smiths Lake Field Station | SL9 | Smiths Lake Old Students Quarters | G | - | Throughout | No asbestos materials Identified | - | - | - | - | - | - | N/A |
FSSL | Smiths Lake Field Station | SL9 | Smiths Lake Old Students Quarters | G | - | Exterior, West | Inside Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | SST1C | Main Service Tunnel H13 West Branch | G | - | Throughout | No asbestos materials Identified | - | Negative | - | - | - | - | N/A |
MISC | Tarban Creek | TC1 | Tarban Creek Boat Shed TC1 | G | G01 | Kitchen, Under Sink | Sink Pad | Bituminous Membrane | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 601 | - | Inside Electrical Cabinet (no access) | Electrical Backing Board | Removed - Suspected Positive | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 177 | Electrical Cupboard | Inside Main Switchvoard Electrical Cabinet (new appearance cabinet) | Electrical Backing Board | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 182 | Electrical Cupboard | Inside Electrical Cabinet (new appearance cabinet) | Electrical Backing Board | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 1 | 1Q5 | Electrical Cupboard | Inside Electrical Cabinet (new appearance cabinet) | Electrical Backing Board | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q4 | Electrical Cupboard | Inside Electrical Cabinet (new appearance cabinet) | Electrical Backing Board | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 2 | 2Q11 | Electrical Cupboard | Inside Electrical Cabinet (new appearance cabinet) | Electrical Backing Board | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q12 | Electrical Cupboard | Inside Electrical Cabinet (new appearance cabinet) | Electrical Backing Board | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 4 | 4Q13 | Electrical Cupboard (E4Q02) | Inside Electrical Cabinet (new appearance cabinet) | Electrical Backing Board | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 5 | 5Q1 | Opposite Room 507, Electrical Cupboard | Inside Electrical Cabinet (new appearance cabinet) | Electrical Backing Board | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 6 | 620 | Electrical Cupboard | Inside Electrical Cabinet (new appearance cabinet) | Electrical Backing Board | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 7 | 7Q8 | Opposite Room 711, Electrical Cupboard | Inside Electrical Cabinet (new appearance cabinet) | Electrical Backing Board | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 8 | 8Q5 | Opposite Room 811, Electrical Cupboard | Inside Electrical Cabinet (new appearance cabinet) | Electrical Backing Board | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 10 | 10Q1 | Opposite Room 1011, Electrical Cupboard | Inside Electrical Cabinet (new appearance cabinet) | Electrical Backing Board | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 14 | 14Q1 | Opposite Room 1401, Electrical Cupboard | Inside Electrical Cabinet (new appearance cabinet) | Electrical Backing Board | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | 802A | West Wall | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive - Removed | - | - | - | Item removed 17/11/2018 by Pure Contracting - RiskTech Clearance Certifcate dated 17/11/2018 | Yes |
KENC | Kensington Campus | H20 | Civil Engineering | 8 | ROQ1 | Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive - Removed | - | - | - | Item removed - No removal documentation provided | Yes |
MISC | Tarban Creek | TC1 | Tarban Creek Boat Shed TC1 | G | - | Exterior, East, Above Roller Shutter Doors | Infill Panels | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MISC | Tarban Creek | TC1 | Tarban Creek Boat Shed TC1 | G | G03 | Boat Store Throughout | Ceiling | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MISC | Tarban Creek | TC1 | Tarban Creek Boat Shed TC1 | G | - | Exterior, East | Eaves | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MISC | Tarban Creek | TC1 | Tarban Creek Boat Shed TC1 | G | G01 | Kitchen Throughout | Floor Covering | Sheet Vinyl (grey colour) | Negative | - | - | - | - | N/A |
MISC | Tarban Creek | TC1 | Tarban Creek Boat Shed TC1 | G | - | Exterior, North-west, Above Kitchen Windows | Infill Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
MISC | Tarban Creek | TC1 | Tarban Creek Boat Shed TC1 | G | - | Exterior, West Entrance | Awning | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
MISC | Tarban Creek | TC1 | Tarban Creek Boat Shed TC1 | G | G03 | Boat Store, South-West | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | N/A |
MISC | Tarban Creek | TC1 | Tarban Creek Boat Shed TC1 | G | GQ3 | Throughout | Shower and Toilet Cubicle Partitions | Compressed Fibre Cement Sheeting | Suspected Negative | - | - | - | - | N/A |
MISC | Tarban Creek | TC3 | Tarban Creek Boat Shed TC3 | G | - | Throughout | No asbestos materials identified | - | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 2 | E2Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 232) | Inside Electrical Cabinets | Electrical Backing Boards | Removed -Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New electrical cabinets) | Yes |
KENC | Kensington Campus | F21 | Library | 5 | E5Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 501) | Inside Electrical Cabinets | Electrical Backing Boards | Removed -Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New electrical cabinets) | Yes |
KENC | Kensington Campus | F21 | Library | 9 | E9Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 901) | Inside Electrical Cabinets | Electrical Backing Boards | Removed -Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New electrical cabinets) | Yes |
KENC | Kensington Campus | F21 | Library | 10 | E10Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 1001) | Inside Electrical Cabinets | Electrical Backing Boards | Removed -Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New electrical cabinets) | Yes |
KENC | Kensington Campus | F21 | Library | 11 | E11Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 11Q1) | Inside Electrical Cabinets | Electrical Backing Boards | Removed -Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New electrical cabinets) | Yes |
KENC | Kensington Campus | F21 | Library | 12 | E12Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 12Q4) | Inside Electrical Cabinets | Electrical Backing Boards | Removed -Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New electrical cabinets) | Yes |
KENC | Kensington Campus | F21 | Library | 13 | E13Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 13Q4) | Inside Electrical Cabinets | Electrical Backing Boards | Removed -Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New electrical cabinets) | Yes |
KENC | Kensington Campus | F21 | Library | 14 | E14Q01 | Electrical Cupboard off Passenger Lift Lobby (Room 14Q3) | Inside Electrical Cabinets | Electrical Backing Boards | Removed -Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New electrical cabinets) | Yes |
KENC | Kensington Campus | F21 | Library | 15 | 1501 | Plant Room | Inside Main Switchboard Cabinets | Electrical Backing Boards | Removed -Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. (Note: New switchboard electrical cabinets) | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 18 | 1803 | - | Lift Motor Controller Cabinets (new appearance cabinets present) | Electrical Backing Boards | Removed -Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | G6 | Blockhouse | G | G10H | - | Air Conditioning Ductwork Heater Bank | Insulation Board | Removed -Suspected Positive | - | - | - | Item Removed: 05-02-2014. No removal/clearance documentation was provided. New ductwork present. | Yes |
KENC | Kensington Campus | G27 | AGSM | LG | LG09 | (Previously Room LG05A) Electrical Switch Room | Inside Electrical Switch Board Cabinet | Electrical Backing Board | Suspected Positive - Removed | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
MISC | Tarban Creek | TC3 | Tarban Creek Boat Shed TC3 | G | - | Exterior, North-East | Awning | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
DPFS | David Phillips Field | DP4 | Grounds Depot | G | G02 | - | Within Electrical Cabinet | Electrical Backing Board | Suspected Positive - Removed | - | - | - | Item not sighted during RiskTech 2018 inspection. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | D14 | UNSW Hall | G | BG95 | Main Switch Room, South | Within Electrical Cabinet | Electrical Backing Board | Suspected Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENE | Kensington Environs | BS30 | 30 Botany Street | G | UGQ04 | Exterior, Entrance, East | Within Electrical Cabinet | Electrical Backing Board | Suspected Positive - Removed | - | - | - | Item removed. No removal/clearance documentation provided. | Yes |
FSFG | Fowlers Gap Field Station | FG6 | Fowlers Gap Machinery Shed | G | - | Old Lathe Shed, Interior, West Side | Within Electrical Cabinet | Fibre Cement Sheeting | Suspected Positive - Removed | - | - | - | Item Removed: UNSW site personnel informed RiskTech that fibre cement debris removed. No former electrical cabinet sighted by RiskTech during the inspection. | Yes |
KENC | Kensington Campus | E6 | Roundhouse | G | Former Rooms GQ05 & GQ08 | Exterior, North | Infill Panels | Fibre Cement Sheeting | Suspected Positive - Removed | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
KENE | Kensington Environs | AS10 | 10 Arthur Street | G | CQ3 | - | Ceiling | Fibre Cement Sheeting | Suspected Positive - Removed | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
MISC | Tarban Creek | TC3 | Tarban Creek Boat Shed TC3 | 01 | 103 | Throughout | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
MISC | Tarban Creek | TC3 | Tarban Creek Boat Shed TC3 | 01 | 104 | Throughout | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 2Q01 | - | Fire Door | Insulation Core | Removed -Suspected Positive | - | - | - | Item Removed: 28-9-2015. Refer to Greencap-NAA Clearance Report dated 29 September 2015 (reference C107266 : J134916.003). Note: New fire door tagged 'TDF, 201-'. | Yes |
KENC | Kensington Campus | G6 | Blockhouse | 2 | 2Q03 | - | Fire Door | Insulation Core | Removed -Suspected Positive | - | - | - | Item Removed: 28-9-2015. Refer to Greencap-NAA Clearance Report dated 29 September 2015 (reference C107266 : J134916.003). Note: New fire door tagged 'TDF, 201-'. | Yes |
MISC | Tarban Creek | TC3 | Tarban Creek Boat Shed TC3 | 01 | 105 | Throughout | Walls | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
MISC | Tarban Creek | TC3 | Tarban Creek Boat Shed TC3 | G | G05 | Throughout | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K14 | Physics Theatre | LG | - | Exterior, East of Room LG19 | Within Electrical Cabinet | Electrical Backing Board | Removed -Suspected Positive | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | LG | LG55 | Duct Riser | Pipework Insulation | Lagging | Suspected Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 141A | Beneath Pipe Penetration, Under Side of Slab | Packer | Fibre Cement Sheeting | Suspected Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 143 | - | Ceiling | Fibre Cement Sheeting | Suspected Positive (Removed) | - | - | - | Item Removed 21/11/2015. Refer to Airsafe Asbestos Clearance Certificate dated 23/11/2015 (report reference: 29259) | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | 232 | Ceiling Space | Debris | Fibre Cement Sheeting | Suspected Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | - | Exterior, North Side, Outside Room 2Q7 | Windows (between frame and brick facade) | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P3 | Remediate (remove and/or seal) deteriorating mastic sealant under controlled conditions by a Class A/B contractor within a planned control program. | No |
MANV | Manly Vale | MV3 | Laboratory 2 | G | G1Q | - | Within Electrical Cabinet | Electrical Backing Board | Suspected Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
MANV | Manly Vale | MV4 | Workshop | G | GQ1 | - | Within Electrical Cabinet | Electrical Backing Board | Suspected Positive (Removed) | - | - | - | No removal/clearance documentation was provided. | Yes |
MANV | Manly Vale | MV7 | Laboratory 4 | G | G04 | - | Within Electrical Cabinet | Electrical Backing Board | Suspected Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
MANV | Manly Vale | MV9 | Laboratory 3 | G | G01 | Main Switch | Within Electrical Cabinet | Electrical Backing Board | Suspected Positive (Removed) | - | - | - | Item removed. No removal/clearance documentation was provided. | Yes |
MISC | Tarban Creek | TC3 | Tarban Creek Boat Shed TC3 | 01 | 1Q1 | South | Awning | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F21 | Library | 1 | 1Q10 | Fire Stairs | Fire Door | Core Insulation | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | 1Q11 | - | Floor Covering | Vinyl Floor Tiles (cream colour) | Removed - Suspected Positive | - | - | - | Item Removed: Refer to NAA Clearance Certificate (Ref: 77747) dated 10 September 2011. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | - | Exterior, Roof Above Plant Room (Room180) | Roof Covering | Bituminous Membrane | Removed - Suspected Positive | - | - | - | Item Removed: Refer to NAA Clearance Certificate (Ref: C108081:J116750) dated February 2013. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 7 | 703 | Lift Motor Room | Lift Motors - Unit No.43 (currently being replaced) | Brake Pads | Suspected Positive - Removed | - | - | - | Item removed. No removal/clearance documention was provided. | Yes |
RANC | Randwick Campus | R14 | Institute of Languages | R | - | Former Lift Motor Room | Lift Motor | Brake Pads | Removed - Suspected Positive | - | - | - | Item removed. No removal/clearance documentation was provided. Note: The room is now Machine Room-Less (MRL): no lift motor present | Yes |
KENC | Kensington Campus | K17 | Building K17 | 3 | 3Q03 | Fire Exit | Fire Door | Core Insulation | Suspected Positive - Removed | - | - | - | Item removed. Contractor (Bismac) documentation provided for replacement of fire door dated 7/4/2014. No asbestos clearance documentation provided. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 4 | 4Q07 | Fire Exit | Fire Door | Core Insulation | Suspected Positive - Removed | - | - | - | Item removed. Contractor (Bismac) documentation provided for replacement of fire door dated 7/4/2014. No asbestos clearance documentation provided. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 5 | 5Q02 | Fire Exit | Fire Door (Tagged 198_) | Core Insulation | Suspected Positive - Removed | - | - | - | Item removed. Contractor (Bismac) documentation provided for replacement of fire door dated 7/4/2014. No asbestos clearance documentation provided. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 5 | 5Q04 | Fire Exit | Fire Door (Tagged 198_) | Core Insulation | Suspected Positive - Removed | - | - | - | Item removed. Contractor (Bismac) documentation provided for replacement of fire door dated 7/4/2014. No asbestos clearance documentation provided. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 6 | 6Q02 | Fire Exit | Fire Door | Core Insulation | Suspected Positive - Removed | - | - | - | Item removed. Contractor (Bismac) documentation provided for replacement of fire door dated 7/4/2014. No asbestos clearance documentation provided. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 7 | 701 | Entrance | Fire Door | Core Insulation | Removed - Suspected Positive | - | - | - | Item Removed. Contractor (Bismac) documentation provided for replacement of fire door dated 7/4/2014. No asbestos clearance documentation provided. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 7 | 703 | Lift Motor Room | Fire Door | Core Insulation | Suspected Positive - Removed | - | - | - | Item removed. Contractor (Bismac) documentation provided for replacement of fire door dated 7/4/2014. No asbestos clearance documentation provided. | Yes |
KENC | Kensington Campus | F21 | Library | 2 | - | Southern End, Open Roof Section (Above Plant Room) | Roof | Bituminous Membrane | Removed -Suspected Positive | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 8 February 2013. | Yes |
KENC | Kensington Campus | F21 | Library | 5 | - | Roof, Northern Section of New Tower Building | Roof Covering | Bituminous Membrane | Removed -Suspected Positive | - | - | - | Item Removed: Refer to Cetec Clearance Certificate dated 8 November 2016. | Yes |
KENC | Kensington Campus | G6 | Blockhouse | G | GQ01 | - | Fire Door | Insulation Core | Removed -Suspected Positive | - | - | - | Item Removed: 05-02-2014. No removal/clearance documentation was provided. New appearance fire door. | Yes |
KENC | Kensington Campus | G6 | Blockhouse | G | GQ03 | - | Fire Door | Insulation Core | Removed -Suspected Positive | - | - | - | Item Removed: 05-02-2014. No removal/clearance documentation was provided. New appearance fire door tagged Bismac 2000'. | Yes |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 1Q01 | - | Fire Door | Insulation Core | Removed -Suspected Positive | - | - | - | Item Removed: 28-9-2015. Refer to Greencap-NAA Clearance Report dated 29 September 2015 (reference C107266 : J134916.003). Note: New fire door tagged 'TDF, 201-'. | Yes |
KENC | Kensington Campus | G6 | Blockhouse | 1 | 1Q03 | - | Fire Door | Insulation Core | Removed -Suspected Positive | - | - | - | Item Removed: 28-9-2015. Refer to Greencap-NAA Clearance Report dated 29 September 2015 (reference C107266 : J134916.003). Note: New fire door tagged 'TDF, 201-'. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 141A | - | Debris | Fibre Cement Sheeting | Suspected Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
MISC | Tarban Creek | TC3 | Tarban Creek Boat Shed TC3 | 01 | 106 | Throughout | Walls | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E4 | Squarehouse | G | GQ9 | Plant Room | Ductwork Heater Bank No.2 | Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E4 | Squarehouse | G | GQ9 | Plant Room | Ductwork Heater Bank No.1 | Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | 1015 | Laboratory | Air Conditioning Ductwork Heater Bank | Millboard Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 306 | Cleaners Cupboard | Shelving, Vinyl Sheet Coverings | Millboard (Backing on Vinyl Sheeting) | Removed - Positive (Chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 21 October 2019. Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | F21 | Library | 17 | Roof | Roof near NE corner | Roof membrane remnant | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 26th October 2019 | Yes | |||
KENC | Kensington Campus | F22 | Bank Building | 2 | 217 | Ceiling Space | Air Conditioning Ductwork Heater Unit | Insulation Board | Removed - Positive (chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 31 January 2020. Removed by Pure Contracting. | Yes |
KENC | Kensington Campus | K15 | Old Main | 1 | 1Q18 | Fire Door | Fire Door | Asbestos cored fire door | Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 25th November | Yes |
KENC | Kensington Campus | C20 | Morven Brown | 1 | 1Q9 & 2Q11 | Fire Doors | Fire Doors | Asbestos cored fire door x 2 | Positive - Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 16th December | Yes |
KENC | Kensington Campus | H13 | The Red Centre | Roof top | Paver backer 64g fibreboard fragment | Negative | - | - | - | N/A | ||||
KENC | Kensington Campus | H14 | The Red Centre | Roof top | Sheet membrane 15g bituminous membrane | Negative | - | - | - | N/A | ||||
KENC | Kensington Campus | F23 | Mathews Building | 18 | 1803 | Lift Motor Room | Lift Motor 16 | Brake Pad Linings | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F24 | Mathews Building | 18 | 1802 | Lift Motor Room | Lift Motor 17 | Brake Pad Linings | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F25 | Mathews Building | 18 | 1802 | Lift Motor Room | Lift Motor 18 | Brake Pad Linings | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F26 | Mathews Building | 18 | 1802 | Lift Motor Room | Lift Motor 19 | Brake Pad Linings | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Computing Science | - | 06LS41 | Lift shaft 41 | Dust from walls 41-42 | Dust and Debris | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Computing Science | - | 06LS42 | Lift shaft 42 | Door panel lift 41-42 | Fibre Cement Sheeting | Positive | - | - | P3 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Computing Science | - | 06LS41 | Lift 41 | - | Millboard Lining | Positive | - | - | P3 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | KENC | K17 | Computing Science | - | 06LS42 | Lift 42 | - | Millboard Lining | Positive | - | - | P3 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | KENC | F21 | Library | 1 | 105 | Shaft openings | Marked ductwork sections | Insulation / Debris | - | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 2 March 2020 | Yes |
KENC | KENC | F21 | Library | 1 | 106 | Shaft openings | Marked ductwork sections | Insulation / Debris | - | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 2 March 2020 | Yes |
KENC | KENC | F21 | Library | B | LGQ05 | Plant Room | Above air handling unit (eastern section) | Insulation / Debris | - | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 2 March 2020 | Yes |
KENC | KENC | The Village Green | - | - | Village Green | Daily Air Monitoring Certs - please see 2020 Air Monitoring Certificate folder | - | - | - | - | - | N/A | ||
KENC | KENC | F21 | Library | 1 | - | South Plant Room Roof (NW & NE Corners) | Membrane upper layer & membrane remnants beneath upper layer | Membrane Layer | - | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 15 February 2020 | Yes |
KENC | KENC | F21 | Library | 16 | - | Roof (Near Mid East Side) | Membrane upper layer & membrane remnants beneath upper layer | Membrane Layer | - | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 15 February 2020 | Yes |
KENC | KENC | F21 | Library | 1 | 130 | Old Northern Building Section, Eastern Shaft Openings (to Room 130A - Plant Room) | On Soffit, Top of Ductwork & Adjacent Surfaces | Insulation Residue & Debris | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 10 February 2020. | Yes |
KENC | KENC | F21 | Library | 1 | 130A | Plant Room | Inside Air Handling Unit | Asbestos limpet debris | - | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 10 February 2020 | Yes |
KENC | KENC | F21 | Library | 1 | 130 | Mid East Side Adjacent Return Air Grille | On Floor | Insulation debris | Negative | - | - | - | - | N/A |
KENC | KENC | F21 | Library | 1 | 130 | Mid East Side Adjacent Return Air Grille | On Floor | Insulation & general debris | Negative | - | - | - | - | N/A |
KENC | KENC | F21 | Library | 1 | 130 | Mid East Side Adjacent Return Air Grille | On Floor | Insulation debris | Negative | - | - | - | - | N/A |
KENC | KENC | F21 | Library | 1 | 130 | Mid East Side Adjacent Return Air Grille | On Floor | Insulation & general debris | Negative | - | - | - | - | N/A |
KENC | KENC | F21 | Library | 4 | L4E1 | Shaft Openings (North,Centre & South) | Ductwork & adjacent surfaces | Insulation remnanats & debris material | - | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 2nd December 2019 | Yes |
KENC | KENC | F21 | Library | 3 | L3W1 | Shaft Openings (North,Centre & South) | Ductwork & adjacent surfaces | Insulation remnanats & debris material | - | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 25th November 2019 | Yes |
KENC | KENC | F21 | Library | 15 | 1501 | Plant Room, NE Air Handling Unit | Exterior Panelling | Insulation Board | Assumed Negative | - | - | - | - | N/A |
KENC | KENC | F21 | Library | LG | - | Lower Ground level | Daily Air Monitoring Certs - please see 2020 Air Monitoring Certificate folder | - | - | - | - | - | N/A | |
KENC | KENC | The Village Green | - | - | Stockpiles 1-6, see report | Visual inspection of exposed ground surface of backfilled test pits | Exposed ground surface from asbestos removal work | - | - | - | - | See Clearance Certificate dated April 2020 | N/A | |
COFA | PADDINGTON | CFAA | Block A | B | AB3 | Plant Room | Fire Doors x 2 (no tag) | Insulation Core | Positive (Removed) | - | - | - | Item removed by Pure Contracting. Refer to RiskTech Compliance Clearance Report dated 12/11/2021. Note: New fire doors installed (tagged ' Bismac Year of Man. 2021'). | Yes |
KENS | KENC | C22 | Chancellery | B | B12 | - | Air Handling Unit Joins & Ductwork Flange Joints & Joins | Sealant Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENS | KENC | C22 | Chancellery | LG | LGQ18 | - | Ductwork Flange Joins (old ductwork only) | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENS | KENC | C22 | Chancellery | LG | - | Throughout, Various Areas | Ductwork Flange Joints (old ductwork only) | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENS | KENC | C22 | Chancellery | LG | - | Exterior, Central Wing, West Side (outside LGQ2) | Vertical Joint Between External Window Framework & Brick Façade | Mastic Sealant (light grey colour) | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | LG | - | Exterior, West Wing, North Side | Vertical Joint Between External Concrete Columns & Metal Cover Plate | Mastic Sealant | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | LG | - | Exterior, West Wing, North Side Entrance Awning | Roof Covering | Membrane Coating | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | LG | - | Exterior, Throughout | Vertical Joints Between External Window Framework & Brick Façade | Mastic Sealant (light grey colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Consideration should be given to further investigation to determine the extent of the asbestos containing sealant in the facade joints. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENS | KENC | C22 | Chancellery | LG | GQ3 | Stairwell | Gap Between Internal Window Framework & Glass Pane | Mastic Sealant | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | G | - | Throughout, Various Areas | Ductwork Flange Joints (old ductwork only) | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENS | KENC | C22 | Chancellery | G | - | Exterior, Throughout | Vertical Joints Between External Window Framework & Brick Façade | Mastic Sealant (light grey colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Consideration should be given to further investigation to determine the extent of the asbestos containing sealant in the facade joints. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENS | KENC | C22 | Chancellery | 01 | 1Q3 | West Wing, North Side | Gap Between Internal Window Framework & Glass Pane | Mastic Sealant | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | 01 | - | Throughout, Various Areas | Ductwork Flange Joints (old ductwork only) | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENS | KENC | C22 | Chancellery | 01 | - | Exterior, West Wing, North Side, Outside Room 1Q3 | Vertical Joint Between External Window Framework & Concrete Column | Mastic Sealant | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | 01 | - | Exterior, West Wing, North Side, Outside Room 1Q3 | Gap Between External Window Framework & Glass Pane | Mastic Sealant | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | 01 | - | Exterior, Throughout | Vertical Joints Between External Window Framework & Brick Façade | Mastic Sealant (light grey colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Consideration should be given to further investigation to determine the extent of the asbestos containing sealant in the facade joints. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENS | KENC | C22 | Chancellery | 02 | 2Q5 | West Wing, Stairwell, North Side | Gap Between Internal Window Framework & Glass Pane | Mastic Sealant | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | 02 | 2Q10 | West Wing, Stairwell, West Side | Gap Between Internal Window Framework & Glass Pane | Mastic Sealant | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | 02 | 2Q15 | Service Duct off Room 2Q15 | Ceiling Coating (insulation on plasterboard) | Insulation (sprayed vermiculite material) | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | 02 | - | Exterior, West Wing, North Side, Outside Room 2Q5 | Gap Between External Window Framework & Glass Pane | Mastic Sealant | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | 02 | - | Exterior, Central Wing, West Side, Outside Room 2Q10 | Vertical Joint Between External Window Framework & Brick Façade | Mastic Sealant (light grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENS | KENC | C22 | Chancellery | 02 | - | Exterior, Throughout | Vertical Joints Between External Window Framework & Brick Façade | Mastic Sealant (light grey colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Consideration should be given to further investigation to determine the extent of the asbestos containing sealant in the facade joints. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENS | KENC | C22 | Chancellery | 02 | - | Exterior, West Wing, North Side, Balconies | Roof Covering | Membrane Coating | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | 02 | - | Exterior Throughout | Eaves | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENS | KENC | C22 | Chancellery | 03 | 306 | Outside Room 306 | Gap Between Internal Window Framework & Glass Pane | Mastic Sealant | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | 03 | 3Q6 | Stairwell | Gap Between Internal Window Framework & Glass Pane | Mastic Sealant | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | 03 | - | Exterior, North Side, Outside Room 302 | Vertical Joint Between External Window Framework & Brick Façade | Mastic Sealant (light grey colour) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENS | KENC | C22 | Chancellery | 03 | - | Exterior, Throughout | Vertical Joints Between External Window Framework & Brick Façade | Mastic Sealant (light grey colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Consideration should be given to further investigation to determine the extent of the asbestos containing sealant in the facade joints. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENS | KENC | C27 | Wallace Wurth | LG | LG42 | Above Cool Rooms, Brick Walls & Soffit, Beneath White-Coloured Paint Encapsulant | Walls/Soffit Covering (asbestos signage present) | Bituminous Coating (black colour) | Removed | - | - | - | Removed - refer RiskTech Clearance cert dated 21/09/2021 | Yes |
KENS | KENC | C27 | Wallace Wurth | LG | LG42 | Behind Cool Rooms, Brick Walls | Walls Covering | Bituminous Coating (black colour) | Removed | - | - | - | Removed - refer RiskTech Clearance cert dated 21/09/2021 | Yes |
KENS | KENC | C27 | Wallace Wurth | LG | LG42 | Above & Behind Cool Rooms, Brick Walls & Soffit, Beneath White-Coloured Paint Encapsulant | Walls/Soffit Covering | Bituminous Coating (black colour) | Removed - Positive (chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 21 September 2021. Removed by Aston Demolition Pty Ltd. | Yes |
KENS | KENC | C27 | Wallace Wurth | LG | LG43 | - | Chilled Water Pipe, On Outer Surface of Insulation | Bituminous Coating (black colour) | Negative | - | - | - | - | N/A |
KENS | KENC | C27 | Wallace Wurth | 1 | 101 | - | Interior of Old Main Ductwork, Flange Joints & Joins | Mastic Sealant | Removed - Positive (chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 1 August 2019. Removed by Ashton Demolition Pty Ltd. | Yes |
KENS | KENC | C27 | Wallace Wurth | 1 | 101A | - | Interior of Old Ductwork, Flange Joints & Joins | Mastic Sealant | Removed - Positive (chrysotile) | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 1 August 2019. Removed by Ashton Demolition Pty Ltd. | Yes |
KENS | KENC | C27 | Wallace Wurth | 1 | 1Q03 | Former Plant Room | Rear North Wall & Ceiling | Insulation, Cementitious & Bituminous Material | Negative | - | - | - | - | N/A |
KENS | KENC | C27 | Wallace Wurth | 1 | 1Q03 | Former Plant Room | Beneath Raised cement Flooring | Insulation & Bituminous Material | Negative | - | - | - | - | N/A |
KENS | KENC | C20 | Morven Brown | 3 | 3Q2 | North-South corridor adjacent fire stairs | Vinyl floor tiles beneath carpet tiles | Vinyl floor tiles & associated adhesive | Negative | - | - | - | - | N/A |
KENS | KENC | D26 | Biolink | 1 | 130 | Floor | Adhesive beneath vinyl floor tiles | Adhesive | Removed | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 30 October 2020. | Yes |
KENS | KENC | D26 | Biolink | 1 | 142 | Floor (northern section) | Adhesive beneath vinyl floor tiles | Adhesive | Removed | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 30 October 2020. | Yes |
KENS | KENC | D26 | Biolink | 1 | 142 | Ductwork (northern section) | Duct joins | Asbestos containing mastic | Removed | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 30 October 2020. | Yes |
KENS | KENC | D26 | Biolink | 1 | 1Q12 | Floor (outside room 130 & northern section of room 142) | Adhesive beneath vinyl floor tiles | Adhesive | Removed | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 30 October 2020. | Yes |
KENS | KENC | D26 | Biolink | 1 | 142 | Specimen Room (Former Room 142) | Wall sheeting | insulation on spandrel panel brackets x 2 | Removed | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 11 December 2020. | Yes |
KENS | KENC | C24 | Clancy | G | GQ6 | SE Pyramid, External South of Room GQ6 | Beneath Floor Pavers | Bituminous membrane | Negative | - | - | - | - | N/A |
KENS | KENC | E12 | UNSW Business School | G | GQ10 | External North Side old façade section | façade joints | Mastic sealant | Negative | - | - | - | - | N/A |
KENS | KENC | E12 | UNSW Business School | G | GQ10 | External North Side old façade section | façade panel immediately adjacent to joints | Cementitious quartz material | Negative | - | - | - | - | N/A |
KENS | KENC | D26 | Biolink | G | - | Various rooms | All air monitoring certs for 2021 | - | - | - | - | - | N/A | |
KENS | KENC | C22 | Chancellery | 3 | 307 | Steel work beneath roof | Sprayed insulation | Vermiculite | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | 3 | 307 | Debris on floor | Sprayed insulation | Vermiculite | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | 3 | - | Main east section (central wing) | Vinyl floor tiles | Vinyl | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | G | G20 | Floor | Vinyl floor tiles | Vinyl | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | G | G20 | Floor | Bitumious Floor Sheet Covering | Bitumious Floor Sheet Covering | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | 1 | 159 | Floor | Vinyl floor tiles | Vinyl | Negative | - | - | - | - | N/A |
KENS | KENC | D26 | Bio Sciences North | G | GQ51 | Biosciences North, West Services Riser, Structural Walls | Conduits (Tubes) | Moulded Fibre Cement Material | Positive (chrysotile & amosite) | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENS | KENC | C6 | International House | G | 116 | Corridor | Bathroom corridor ceiling lining | Low density fibre board | Positive | - | - | - | Item removed. Refer Moffit Projects clearance cert dated 12th January 2022 | Yes |
KENS | KENC | C6 | International House | 1 | 144 | Bathroom | Bathroom ceiling lining | Low density fibre board | Positive | - | - | - | Item removed. Refer Moffit Projects clearance cert dated 12th January 2022 | Yes |
KENS | KENC | F23 | Mathews Building | 5 | 5Q15 | Roof outside plantroom | Stored removed sheeting | Fibre cement sheeting | Negative | - | - | - | - | N/A |
KENS | KENC | F23 | Mathews Building | 5 | 5Q15 | Roof outside plantroom | Stored removed window sections on window framework | Mastic beading | Positive chrysotile | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENS | KENC | F23 | Mathews Building | 5 | 5Q15 | Roof outside plantroom | Stored removed window sections on window framework | Mastic beading | Positive chrysotile | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENS | KENC | F23 | Mathews Building | 5 | 5Q15 | West Roof Section, Outside Plant Room (Room 5Q15) | Window Framework (gap between glass & frame) | Sealant Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENS | KENC | F23 | Mathews Building | 5 | 5Q15 | Plantroom 5Q15 | Attached to soffit | Plaster sheeting | Negative | - | - | - | - | N/A |
KENS | KENC | D26 | Biolink | 3 | 3Q10 | South,East & West sides | Wall sheeting | Plaster sheeting | Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 17 November 2021 | Yes |
KENS | KENC | D26 | Biolink | 2 | 255 | Floor | Adhesive beneath floor covering | Adhesive | Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 13 October 2021 | Yes |
KENS | KENC | D26 | Biolink | 2 | 256 | Floor | Adhesive beneath floor covering | Adhesive | Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 13 October 2021 | Yes |
KENS | KENC | D26 | Biolink | 2 | 257 | Floor | Adhesive beneath floor covering | Adhesive | Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 13 October 2021 | Yes |
KENS | KENC | D26 | Biolink | 2 | 258 | Floor | Adhesive beneath floor covering | Adhesive | Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 13 October 2021 | Yes |
KENS | Kensington Campus | D26 | Biolink | 2 | 259 | Floor | Adhesive beneath floor covering | Adhesive | Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 13 October 2021 | Yes |
KENS | KENC | D26 | Biolink | 1 | 131a | Above Cool Room | Fire door | Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 28 September 2021 | Yes | |
KENS | KENC | D26 | Biolink | 1 | 142 | West side | Wall sheeting | Plaster sheeting | Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 28 September 2021 | Yes |
KENS | KENC | D26 | Biolink | 1 | 131a | Floor | Adhesive beneath vinyl floor tiles | Adhesive | Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 28 September 2021 | Yes |
KENS | KENC | D26 | Biolink | 1 | 132 | Biolink | On Concrete Floor Slab (beneath floor covering) | Bituminous Adhesive | Removed - Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 28 September 2021. | Yes |
KENS | Kensington Campus | D26 | Biolink | 1 | 132B | Biolink | On Concrete Floor Slab (beneath floor covering) | Bituminous Adhesive | Removed - Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 28 September 2021. | Yes |
KENS | KENC | D26 | Biolink | 1 | 138b | Floor | Adhesive beneath vinyl floor tiles | Adhesive | Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 28 September 2021 | Yes |
KENS | KENC | D26 | Biolink | 1 | 142 | Floor | Adhesive beneath vinyl floor tiles | Adhesive | Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 28 September 2021 | Yes |
KENS | KENC | D26 | Biolink | 1 | 142a | Floor | Adhesive beneath vinyl floor tiles | Adhesive | Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 28 September 2021 | Yes |
KENS | KENC | D26 | Biolink | 1 | 1Q16 | Floor | Adhesive beneath vinyl floor tiles | Adhesive | Removed | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 28 September 2021 | Yes |
KENS | KENC | C22 | Chancellery | G | - | West wing, North Side, Outside entry | Beneath concrete pavers | Bituminous membrane | Negative | - | - | - | - | N/A |
KENS | KENC | F20 | Goodsell | G | All | Most of ground floor - see cert map | Vinyl floor tiles | Vinyl | Removed | - | - | - | Item Removed: Refer to SSS Clearance Certificate dated 12 September 2022 | Yes |
KENS | KENC | C22 | Chancellery | LG | LG16 | Near centre of room | Vinyl floor tiles | Vinyl | Negative | - | - | - | - | N/A |
KENS | KENC | C22 | Chancellery | LG | LG16 | North end of room | Vinyl floor tiles | Vinyl | Negative | - | - | - | - | N/A |
KENS | KENC | F21 | Library | LG | LGQ08 | Redundant Chiller Plant Room | On Soffit Beneath Services (localised areas) | Insulation Residue (beneath white coloured encapsulant & foil insulation) | 'Positive (amosite) | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENS | KENC | F21 | Library | LG | LGQ08 | Redundant Chiller Plant Room | Hot Water Pipework | Insulation (calico covered) | Removed - 'Positive (amosite) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 22 June 2020 & 29 October 2021. | Yes |
KENS | KENC | F21 | Library | 1 | 101 | Records & Archives Room off Room 1Q4 | Fire Doors | Core Insulation | Negative | - | - | - | - | N/A |
KENS | KENC | F21 | Library | 1 | 106 | Records & Archives Room off Room 1Q4 | Fire Door | Core Insulation | Negative | - | - | - | - | N/A |
KENS | KENC | D14 | UNSW Hall | G | - | Throughout all ground areas | Pipe | Asbestos conduit | Positive | - | - | P3 | See details in survey folder | No |
KENS | KENC | D14 | UNSW Hall | G | - | Throughout all ground areas | some asbestos in ground still remaining | Positive | - | - | P3 | See details in survey folder | No | |
KENS | Kensington Campus | J12 | Newton | G | - | Male & Female toilets | Top of masonry walls at junction | Rope and mastic | Removed | - | - | - | Item removed. Refer Airsfae clearance cert dated 10 June 2023 | Yes |
KENS | Kensington Campus | J12 | Newton | 1 | - | Male & Female toilets | Top of masonry walls at junction | Rope and mastic | - | - | - | P4 | See Jane or Max | No |
KENS | Kensington Campus | J12 | Newton | 2 | - | Male & Female toilets | Top of masonry walls at junction | Rope and mastic | Removed | - | - | - | Item removed. Refer Airsfae clearance cert dated 10 June 2023 | Yes |
KENS | Kensington Campus | J12 | Newton | 3 | - | Male & Female toilets | Top of masonry walls at junction | Rope and mastic | Removed | - | - | - | Item removed. Refer Airsfae clearance cert dated 10 June 2023 | Yes |
KENS | KENC | F13 | Science Theatre | G | G09 | Auditorium Projector Alcoves | Panelling Lining | Fibre Cement Sheeting | Removed | - | - | - | Item removed 6/7/2023 by Pure Contracting. Refer to RiskTech Clearance Certificate dated July 2023. | Yes |
FSFG | Fowlers Gap Field Station | FG20 | Dormitory | G | - | Exterior, west Side, NW Corner, Outside laundry, On Ground | Protective Barrier (pipe valve) | Moulded Fibre Cement pipe Section | Positive (chrysolite & amosite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
FSFG | Fowlers Gap Field Station | FG18 | G | G05 | Laundry | Floor covering | Sheet vinyl | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No | |
FSFG | Fowlers Gap Field Station | FG10 | Nissan Hut | G | G01 | Southern section of shed | Stored sheet | Fibre Cement Sheeting | Positive (chrysolite & amosite) | Non-friable | Med | P3 | Demolished-'Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | Yes |
FSFG | Fowlers Gap Field Station | FG7 | Generator hut | G | G01 | Western End | On ground surface | Fibre Cement Sheet Debris | Removed | - | - | - | Item removed. RiskTech removed fibre cement debris as part of the inspection process. | Yes |
FSFG | Fowlers Gap Field Station | FG3 | Shearing shed | G | G01 | South side | Within electrical cabinet | Electrical backing board | Suspected positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
FSFG | Fowlers Gap Field Station | FG29 | Ochre House | G | GQ1 | Verandah | Flooring | Compressed Fibre Cement Sheeting | Negative | - | - | - | Note: Construction date circa 2010 | N/A |
FSFG | Fowlers Gap Field Station | G | - | Eastern & Western sections, Localised areas (Note: fencing present) | On ground surface | Stored fibre cement sheeting | Assumed Positive | Non-friable | Low | P3 | Restricted access to this area. Remedial works should be undertaken by a Class A/B contractor within a planned control program. | No | ||
FSFG | Fowlers Gap Field Station | G | - | Eastern & Western sections, Localised areas (Note: fencing present) | Old discarded vehicle or machinery items | Brake pad linings | Positive (chrysotile) | Non-friable | Low | P3 | Restricted access to this area. Remedial works should be undertaken by a Class A/B contractor within a planned control program. | No | ||
FSFG | Fowlers Gap Field Station | FG13 | Shearers quarters | G | G19 | Near SE corner, linen cupboard adjoining laundry | Walls | Fibre cement sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
FSFG | Fowlers Gap Field Station | FG13 | Shearers quarters | G | - | Exterior north | Telecommunications pit | Moulded fibre cement material | Positive (chrysolite & amosite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
FSFG | Fowlers Gap Field Station | FG14 | Office Laboratory | G | - | Interior, particularly wet areas (eg. toilets, bathroom & laundry) (Note: presence & extent of flooring beneath floor coverings in the building is unknown) | Flooring (beneath floor coverings) | Compressed Fibre Cement Sheeting | Suspected positive | Non-friable | Low | P4 | Conduct investigation for the presence and extent of asbestos containing compressed fibre cement sheet flooring beneath floor coverings in the building prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG13 | Shearers quarters | G | - | Interior, particularly wet areas (eg. toilets & kitchen) (Note: presence & extent of flooring beneath floor coverings in the building is unknown) | Flooring (beneath floor coverings) | Compressed Fibre Cement Sheeting | Suspected positive | Non-friable | Low | P4 | Conduct investigation for the presence and extent of asbestos containing compressed fibre cement sheet flooring beneath floor coverings in the building prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG5 | G | - | Interior, particularly wet areas (eg. toilet & laundry) (Note: presence & extent of flooring beneath floor coverings in the building is unknown) | Flooring (beneath floor coverings) | Compressed Fibre Cement Sheeting | Suspected positive | Non-friable | Low | P4 | Conduct investigation for the presence and extent of asbestos containing compressed fibre cement sheet flooring beneath floor coverings in the building prior to demolition or refurbishment works. | No | |
FSFG | Fowlers Gap Field Station | FG20 | G | - | Interior, particularly wet areas (eg. bathroom, toilet/shower room & laundry) (Note: presence & extent of flooring beneath floor coverings in the cottage is unknown) | Flooring (beneath floor coverings) | Compressed Fibre Cement Sheeting | Suspected positive | Non-friable | Low | P4 | Conduct investigation for the presence and extent of asbestos containing compressed fibre cement sheet flooring beneath floor coverings in the building prior to demolition or refurbishment works. | No | |
FSFG | Fowlers Gap Field Station | FG20 | G | - | Interior, refurbished areas (Note: Presence & extent of fibre cement sheet walls and or remnants concealed behind new wall linings in the building is unknown) | Walls (beneath new wall linings) | Fibre cement sheeting and/or remnants | Suspected positive | Non-friable | Low | P4 | Conduct investigation for the presence and extent of asbestos containing compressed fibre cement sheet walls and/or remnants of asbestos sheeting behind new wall linings in the building prior to demolition or refurbishment works. | No | |
FSFG | Fowlers Gap Field Station | FG1 | Solarch House | G | - | Interior, refurbished areas (Note: Presence & extent of fibre cement sheet wall linings and or remnants concealed behind new wall linings & ceramic tiles in the building is unknown) | Walls (beneath new wall linings) | Fibre cement sheeting and/or remnants | Suspected positive | Non-friable | Low | P4 | Removed between 26/08/2024 to 31/08/2023 as per Asbestos Clearance Certificate dated 03/09/2024 | No |
FSFG | Fowlers Gap Field Station | FG2 | Solarch House | G | - | Interior, throughout house (Note: Presence & extent of flooring beneath floor coverings in the house is unknown) | Flooring (beneath floor coverings) | Compressed Fibre Cement Sheeting | Suspected positive | Non-friable | Low | P4 | Conduct investigation for the presence and extent of asbestos containing compressed fibre cement sheet flooring beneath floor coverings in the building prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG5 | Cottage 2 | G | - | Interior, refurbished areas (Note: Presence & extent of fibre cement sheet wall linings and or remnants concealed behind new wall linings & ceramic tiles in the building is unknown) | Walls (beneath new wall linings) | Fibre cement sheeting and/or remnants | Suspected positive | Non-friable | Low | P4 | Conduct investigation for the presence and extent of asbestos containing compressed fibre cement sheet walls and/or remnants of asbestos sheeting behind new wall linings and ceramic tiles in the building prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG15 | Cottage 1 | G | - | Interior, refurbished areas (Note: Presence & extent of fibre cement sheet wall linings and or remnants concealed behind new wall linings & ceramic tiles in the building is unknown) | Walls (beneath new wall linings) | Fibre cement sheeting and/or remnants | Suspected positive | Non-friable | Low | P4 | Conduct investigation for the presence and extent of asbestos containing compressed fibre cement sheet walls and/or remnants of asbestos sheeting behind new wall linings and ceramic tiles in the building prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG15 | Cottage 1 | G | - | Interior, particularly wet areas (eg. bathroom, toilet/shower room & laundry) (Note: presence & extent of flooring beneath floor coverings in the cottage is unknown) | Flooring (beneath floor coverings) | Compressed Fibre Cement Sheeting | Suspected positive | Non-friable | Low | P4 | Conduct investigation for the presence and extent of asbestos containing compressed fibre cement sheet flooring beneath floor coverings in the building prior to demolition or refurbishment works. | No |
FSFG | Fowlers Gap Field Station | FG18 | G | - | Interior, refurbished areas (Note: Presence & extent of fibre cement sheet walls and or remnants concealed behind new wall linings in the building is unknown) | Walls (beneath new wall linings) | Fibre cement sheeting and/or remnants | Suspected positive | Non-friable | Low | P4 | Conduct investigation for the presence and extent of asbestos containing compressed fibre cement sheet walls and/or remnants of asbestos sheeting behind new wall linings in the building prior to demolition or refurbishment works. | No | |
FSFG | Fowlers Gap Field Station | FG18 | G | - | Interior, throughout house (Note: Presence & extent of flooring beneath floor coverings in the house is unknown) | Flooring (beneath floor coverings) | Compressed Fibre Cement Sheeting | Suspected positive | Non-friable | Low | P4 | Conduct investigation for the presence and extent of asbestos containing compressed fibre cement sheet flooring beneath floor coverings in the building prior to demolition or refurbishment works. | No | |
FSFG | Fowlers Gap Field Station | FG19 | G | - | Interior, refurbished areas (Note: Presence & extent of fibre cement sheet walls and or remnants concealed behind new wall linings in the building is unknown) | Walls (beneath new wall linings) | Fibre cement sheeting and/or remnants | Suspected positive | Non-friable | Low | P4 | Conduct investigation for the presence and extent of asbestos containing compressed fibre cement sheet walls and/or remnants of asbestos sheeting behind new wall linings in the building prior to demolition or refurbishment works. | No | |
FSFG | Fowlers Gap Field Station | FG19 | G | - | Interior, throughout house (Note: Presence & extent of flooring beneath floor coverings in the house is unknown) | Flooring (beneath floor coverings) | Compressed Fibre Cement Sheeting | Suspected positive | Non-friable | Low | P4 | Conduct investigation for the presence and extent of asbestos containing compressed fibre cement sheet flooring beneath floor coverings in the building prior to demolition or refurbishment works. | No | |
FSFG | Fowlers Gap Field Station | FG13 | G | - | Interior, refurbished areas (Note: Presence & extent of fibre cement sheet walls and or remnants concealed behind new wall linings in the building is unknown) | Walls (beneath new wall linings) | Fibre cement sheeting and/or remnants | Suspected positive | Non-friable | Low | P4 | Conduct investigation for the presence and extent of asbestos containing compressed fibre cement sheet walls and/or remnants of asbestos sheeting behind new wall linings in the building prior to demolition or refurbishment works. | No | |
FSFG | Fowlers Gap Field Station | FG13 | G | - | New waste tip area. Approx 400 metres south of cottage 3 & 4. South of current excavated area. | Discarded Mitsubishi Magna Vehicle.Engine heat shield. | Insulation | Positive (chrysotile) | Friable | Low | P3 | Restrict access to the waste tip area to authorised personnel only. Remedial works should be undertaken by a Class A Contractor within a planned control program. | No | |
FSFG | Fowlers Gap Field Station | FG13 | G | - | New waste tip area. Approx 400 metres south of cottage 3 & 4. South of current excavated area. | Insdie discarded caravan, floor covering | Vinyl floor tiles | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No | |
FSFG | Fowlers Gap Field Station | FG13 | G | - | Waste & storage area (Discarded vehicles & stored materials). Approx 150 metres north Homestead Creek, (on ground) | Stored drinking water troughs | Moulded fibre cement material | Negative | - | - | - | - | N/A | |
FSFG | Fowlers Gap Field Station | FG13 | G | - | Approx 50 metres east of greenhouse, on ground | Protective barriers | Moulded fibre cement pipe sections | Positive (chrysotile & amosite) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No | |
FSFG | Fowlers Gap Field Station | FG13 | G | - | Adjacent main water tank, approx 50 metres east of nissan hut, on ground | On ground surface | Fibre cement sheet debris | Positive (chrysotile & amosite) (Removed) | - | - | - | Item removed. RiskTech removed fibre cement debris as part of the inspection process. | Yes | |
FSFG | Fowlers Gap Field Station | FG13 | G | - | Exterior, south of Solarch house, driveway entry, mostly beneath ground surface | Drainage pipe | Compressed fibre Cement pipe | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No | |
KENS | Kensington Campus | J12 | Newton | 1 | - | Cleaners cupboard | Wall | - | - | - | P4 | See Jane or Max | No | |
KENS | Kensington Campus | J12 | Newton | 1 | - | Bathroom | Wall | Wall sheeting | Removed | - | - | - | Item removed. Refer Airsafe clearance cert dated 15 July 2023 | Yes |
KENS | KENC | D14 | UNSW Hall | G | - | Footpath along College Rd | Soil underneath cement footpath | fibrous cement sheet | Positive 'Amosite asbestos detected,Chrysotile asbestos detected,Crocidolite asbestos detected | - | - | P3 | See details in survey folder | No |
KENC | Kensington Campus | F22 | Bank | 02 | 208 | - | Floor Covering (under carpet) | Tile fragments & Tile adhesive | Negative | - | - | - | See test report dated 28/07/2023 | N/A |
KENC | Kensington Campus | F22 | Bank | 02 | 211 | - | Floor Covering (under carpet) | Tile fragments & Tile adhesive | Negative | - | - | - | See test report dated 28/07/2023 | N/A |
KENC | Kensington Campus | D14 | UNSW Hall | G | - | Ground | Soil covered with a Nonwoven Geotextile Separator | Asbestos containing soil covered - see clearance cert for specific details | - | - | - | Refer clearance cert dated 28/08/2023 | No | |
KENC | Kensington Campus | E15 | Quadrangle | R | R1Q09 | Exhaust Fan EAF-18 – Flexible Connection/Expansion Between Fan & Duct | Cloth-like woven Insulation | Negative | - | - | - | - | N/A | |
KENC | Kensington Campus | E15 | Quadrangle | R | R1Q04 | Exhaust Fan EAF-5 - Duct Section | Insulation Board | Negative | - | - | - | - | N/A | |
KENC | Kensington Campus | E15 | Quadrangle | R | R1Q04 | Exhaust Fan EAF-5 - Duct | Sprayed Vermiculte Insulation | Negative | - | - | - | - | N/A | |
KENC | Kensington Campus | E15 | Quadrangle | R | R1Q04 | Exhaust Fan EAF-5 – Flexible Connection/Expansion Between Fan & Duct | Cloth-like woven Insulation | Negative | - | - | - | - | N/A | |
KENC | Kensington Campus | E15 | Quadrangle | R | R1Q12 | Exhaust Fan EAF-22 - Duct | Sprayed Vermiculte Insulation | Negative | - | - | - | - | N/A | |
KENC | Kensington Campus | E15 | Quadrangle | R | R1Q12 | Exhaust Fan EAF-25 – Flexible Connection/Expansion Between Fan & Duct | Cloth-like woven Insulation | Negative | - | - | - | - | N/A | |
KENC | Kensington Campus | H22 | Valentine Annexe | G | - | External upper awning soffit sheeting northwestern corner of the building | Awning - ceiling | cement sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 1 | 149 | Western Section, Beneath Raised Timber Flooring | Floor Covering | Vinyl Tiles (grey colour) | Positive (Removed) | - | - | - | Item Removed 1 to 3/12/2023. Refer to RiskTech Clearance Certificate dated 4/12/2024. | Yes |
CCS | Cliffbrook Campus | CC2 | Building CC2 | G | - | Exterior, South, SE | Awning Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
CCS | Cliffbrook Campus | CC2 | Building CC2 | G | G04A | Toilet | Partition Wall | Fibre Cement Sheeting | Suspected Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC3 | Building CC3 | G | - | Exterior, North Side | Timber Window (Between Frame & Glass) | Mastic Sealant | Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC3 | Building CC3 | G | - | Exterior, South Side | Sandstone Wall Joints | Cementitious Pointing Material | Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC3 | Building CC3 | G | G01 | South Side | Sandstone Wall Joints | Cementitious Pointing Material | Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC3 | Building CC3 | G | G02 | South Side | Expansion Gap (Between Concrete Floor Slab & Inner Face of Sandstone Wall) | Bituminous Board Material | Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC3 | Building CC3 | G | G03 | - | Ceiling (Between Plasterboard Ceiling Layers) | Insulation Ceiling Board | Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC3 | Building CC3 | G | G03 | West Side | Inside Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC3 | Building CC3 | G | G03 | North Side | Wall Mounted Electrical Board | Electrical Backing Board | Suspected Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC4 | Building CC4 | G | - | Exterior | Windows (between metal framework & glass) | Mastic Sealant | Assumed Positive | - | Low | P4 | 'Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
CCS | Cliffbrook Campus | CC4 | Building CC4 | G | - | Exterior East, Ground Service | Debris | Fibre Cement Sheeting | Positive (chrysotile removed) | - | - | - | Item Removed: RiskTech removed fibre cement debris as part of the inspection process. | Yes |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 1 | - | Exterior | Windows (between metal framework & glass) | Mastic Sealant | Assumed Positive | - | Low | P4 | 'Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 1 | - | Exterior, East side, Near South End | Wall Panelling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 1 | 170 | Toilet | Partition Wall | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 1 | 171 | Toilet | Partition Wall | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 1 | 1Q5 | Fire Stairs | Fire Door (tagged 'Inglis Industries, Installed 1994') | Insulation Care | Suspected Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 1 | 1Q5 | Fire Stairs Exit | Fire Door (tagged 'Wormald, Year of Manufacture 201-') | Insulation Care | Suspected Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 1 | 1Q6 | East | Fire Door (tagged 'Inglis Industries, Installed 1994') | Insulation Care | Suspected Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 1 | 1Q7 | West, Fire Exit | Fire Door (tagged 'Wormald, Year of Manufacture 201-') | Insulation Care | Suspected Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 2 | - | Exterior | Windows (between metal framework & glass) | Mastic Sealant | Assumed Positive | - | Low | P4 | 'Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment.- | No |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 2 | - | Exterior, North Side, West Section | Infill Wall Panelling, Above Windows | Fibre Cement Sheeting | Assumed Positive | - | Low | P4 | 'Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment.- | No |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 2 | 2Q4 | Fire stairs, adjacent to room 205 | Fire Door (tagged 'Inglis Industries, Installed 1994') | Insulation Care | Suspected Negative | - | - | - | - | N/A |
CCS | Cliffbrook Campus | CC4 | Building CC4 | 2 | 2Q5 | Corridor, adjacent to room 259 | Fire Door (tagged 'Inglis Industries, Installed 1994') | Insulation Care | Suspected Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAC | C201 | 1 | C201 | Throughout | Floor Covering | Vinyl Tiles | Positive (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAC | C2Q3 | 2 | C2Q3 | Throughout | Floor Covering | Adhesive | Negative (Removed) | - | - | - | - | Yes |
COFA | Paddington Campus | CFAD | CFAD | 3 | D3Q4 | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAD | CFAD | 3 | D3Q6A | Electrical Cupboard | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | N/A |
COFA | Paddington Campus | CFAE | CFAE | G | - | Exterior, North and South Elevations | Pebble Stone Vertical Wall Joints (between concrete columns & wall panel sections) | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Maintain in current condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
COFA | Paddington Campus | CFAE | CFAE | 01 | - | Exterior, North and South Elevations | Eaves | Fibre Cement Sheeting | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
COFA | Paddington Campus | CFAG | CFAG | G | GGQ3 | Electrical Cupboard | Cover Beneath Electrical Cabinet | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV2 | MANV | B | - | Exterior, Southern Side, Undercover Entrance Note: Installed Post 2019 | Awning Ceiling | Fibre Cement Sheeting | Suspected Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV3 | MANV | B | B03 | East Side, South East Corner | Within Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV3 | MANV | G | GQ5 | East & South | Wall Panelling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MANV | Manly Vale | MV3 | MANV | G | GQ6 | Male Toilets | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV3 | MANV | G | GQ7 | Female Toilets | Wall Lining | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
MANV | Manly Vale | MV3 | MANV | G | - | Exterior, West Side | Stored Sheets, On Ground | Compressed Thick Fibre Cement Sheeting | Positive (chrysotile) (Removed) | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 1 December 2023. | Yes | |||
MANV | Manly Vale | MV3 | MANV | G | - | Exterior | Windows (between glass & timner framework) | Mastic Sealant | Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV5 | Toilet Block | G | G01 | West Side, Front Entry | Soffit Formwork (Underside of Concrete Roof Slab) | Fibre Cement Sheeting | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MANV | Manly Vale | MV7 | Laboratory 4 | G | - | Exterior, Front Entrance | Wall Panelling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | N/A |
MANV | Manly Vale | MV7 | Laboratory 5 | G | G01B | - | Raised Flooring | Compressed Thick Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R1 | Randwick R1 | G | - | - | Window Frames | Mastic Sealant | Positive | Non-Friable | Low | P4 | Maintain in good condition. Further investigation should be undertaken to determine the presence and extent of asbestos containing mastic associated with the windows. If confirmed to contain asbestos. remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R1 | Randwick R1 | G | G50 | Plant Room, South Side, Distribution Board No.1 Cabinet | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R1 | Randwick R1 | G | G50 | Plant Room, North Side, Distribution Board No.2 Cabinet | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R1c | Randwick R1c | G | - | Exterior, South of Building, SW Corner, Ground Surface | Debris | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R1f | Randwick R1f | G | - | Throughout | No asbestos materials identified | - | - | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | G | - | Exterior, North Side, NE Corner, Fire Exit | Wall and Ceiling | Fibre Cement Sheeting | Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | - | Exterior, North Facade, Outside Room G09A | External Infill Window Panelling | Fibre Cement Sheeting | Positive (chrysotile) | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | - | Exterior, Southern Façade, 1st, 2nd, 3rd, 4th, & 5th Bays from Western End Note: 6th & 7th Bay from Western End - metal sheet infill wall panelling | Infill Wall Panelling | Fibre Cement Sheeting | Positive (chrysotile, amosite & crocidolite) | Non-Friable | Med | P3 | Item removed as per Risktech Asbestos Clearance Certificate dated 24/06/2024. | Yes |
RANC | Randwick Campus | R9 | Tramshed | G | - | Exterior, Southern Façade, 1st Bay from Western End, Former Entry | Infill Door Panelling | Fibre Cement Sheeting | Assumed Positive | Non-Friable | Med | P4 | Maintain in good condition. Remove under controlled conditions by a licensed asbestos contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | - | Exterior, Immediately South of Building | Ground Surface | Fibre Cement Sheet Debris | Positive (chrysotile) | Non-Friable | Med | P3 | Remove under controlled conditions by a licensed asbestos contractor as part of a planned program of works or prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | - | Exterior, Southern Façade, 1st Bay from Western End, Above Former Entry | Window Framework (between frame & glass) | Mastic Caulking | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | G | - | Exterior, Southern Façade, Other Bays, Above Former Entry | Window Framework (between frame & glass) | Mastic Caulking | Assumed Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | G | - | Exterior, Southern Façade, Upper Area | Window Framework (between frame & glass) | Mastic Caulking | Suspected Positive | Non-Friable | Low | P4 | Further investigation and sampling required to ascertain presence / absence of asbestos materials when access available or prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | - | Exterior, North-East Corner | Infill Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | G | - | Exterior, Throughout | Window Frames | Mastic Sealant | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | G | - | Exterior, North Side, Outside Room G05B | Window Frames | Mastic Sealant | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | G | - | Exterior, Throughout | Window Frames | Mastic Sealant | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | G | G07 | Distribution Board Cabinet 'R9-DB-G13' | Within Electrical Cabinet | Electrical Backing Boards | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G07 | West Side, SW Corner, West of Room G07C1, Main Switch Board 'R9-MSB-G01' | Within Electrical Cabinet | Electrical Backing Boards | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G07 | SW Corner (within fenced enclosure), South of Room G07E | Inside Electrical Cabinet | Electrical Backing Board | Suspected Positive | Non-Friable | Low | P4 | Label and maintain in good condition. Remove under controlled conditions by a licensed asbestos contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G07K | Distribution Board Cabinet 'R9-DB-G12' | Within Electrical Cabinet | Electrical Backing Boards | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G07K | Above Electrical Distribution Cabinet ' R9-DB-G12' | Within Flash Guards (fuses) | Woven Insulation | Suspected Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G07 | Mechanical Board Electrical Cabinet 'R9-MCC-G02' | Within Electrical Cabinet | Electrical Backing Boards | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | G09 | - | Air Conditioning Ductwork, Flange Joints & Joins | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | G09A | - | Air Conditioning Ductwork, Flange Joints & Joins | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | G15 - G27 | Above Room G15 to G27 | Air Conditioning Ductwork, Flange Joints & Joins | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | G21B | - | Air Conditioning Ductwork, Flange Joints & Joins | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G21C | Distribution Board Cabinet 'R9-DB-G08' & 'R9-DB-G11' | Within Electrical Cabinets | Electrical Backing Boards | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G21C | High Level Steel Beam, Above Electrical Distribution Cabinet ' R9-DB-G08' & R9-DB-G11' | Within Flash Guards (fuses) | Woven Insulation | Suspected Positive | Friable | Low | P3 | Label and maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G21C | Interior, Southern Façade, 4th Bay from Western End | Timber Wall Framework (around nail heads) | Fibre Cement Sheet Remnants | Positive (chrysotile) | Non-Friable | Med | P3 | Remove under controlled conditions by a licensed asbestos contractor as part of a planned program of works or prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G21E | Adjacent Room G25, Distribution Board Cabinet 'R9-DB-G09' | Within Electrical Cabinet | Electrical Backing Boards | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G29 | Distribution Board Cabinet 'R9-DB-G06' | Within Electrical Cabinet | Electrical Backing Boards | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G29 | Above Electrical Distribution Cabinet ' R9-DB-G06' | Within Flash Guards (fuses) | Woven Insulation | Suspected Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G29A | Distribution Board Cabinet 'R9-DB-G01' & 'R9-DB-G02' | Within Electrical Cabinets | Electrical Backing Boards | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G29A | High Level Steel Beam, Above Electrical Distribution Cabinet ' R9-DB-G01' & R9-DB-G02' | Within Flash Guards (fuses) | Woven Insulation | Suspected Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G29A | South Side, SW Corner, Fire Exit | Fire Door (tagged 'Bismac, 201-') | Core Insulation | Suspected Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | G | G29D | Adjacent Room G30, Distribution Board Cabinet 'R9-DB-G05' | Within Electrical Cabinet | Electrical Backing Boards | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G29D | Adjacent Room G30, High Level Steel Beam, Above Electrical Distribution Cabinet ' R9-DB-G05' | Within Flash Guards (fuses) | Woven Insulation | Suspected Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G34 | Distribution Board Cabinet 'R9-DB-G04' | Within Electrical Cabinet | Electrical Backing Boards | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G37 | Toilet | Ceiling Vent Infill Panels | Fibre Cement Sheeting | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | G40 | Distribution Board Cabinet 'R9-DB-G10' | Within Electrical Cabinet | Electrical Backing Boards | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | G | GQ2 | Fire Stairs Exit | Fire Door (tagged 'Bismac, 201-') | Core Insulation | Suspected Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | M | M05G | North Side | Beneath Sink | Bituminous Membrane | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | M | M05K | Plant Room | Air Conditioning Ductwork, Flange Joints & Joins | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | M05K | Plant Room, Localised Area | Floor Covering | Bituminous Membrane | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | M | M10 | Roof Space, Above Room M10 | Air Conditioning Duct Heater Units | Millboard Insulation | Positive (Chrysotile) | Friable | Low | P3 | Remove under controlled conditions by a Class A contractor as part of a planned program of work or prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | M10 | Roof Space, Above Room M10 | Air Conditioning Ductwork, Flange Joints & Joins | Mastic Sealant | Positive (Chrysotile) | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | M13A | West of Male Toilets | Elevated Hot Water Tank | Insulation (behind metal casing) | Suspected Negative | - | - | - | Insulation on hot water tank was synthetic mineral fibre (SMF), where inspected. | N/A |
RANC | Randwick Campus | R9 | Tramshed | M | M13A | Adjacent Elevated Hot Water Tank, West of Male Toilets | Debris | Fibre Cement Sheeting | Positive (chrysotile & crocidolite) (Removed) | - | - | - | Item Removed: RiskTech Compliance removed fibre cement debris as part of the inspection process. | Yes |
RANC | Randwick Campus | R9 | Tramshed | M | M14 | Roof Space, Above Room M14, On Top of Ceiling | Debris | Fibre Cement Sheeting | Assumed Positive | Non-Friable | Low | P3 | Restrict access to the roof space in the interim. Remove under controlled conditions by a Class A/B contractor as part of a planned program of works or prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | M14A | Roof Space, Above Room M13B, On Top of Ceiling | Debris | Fibre Cement Sheeting | Assumed Positive | Non-Friable | Low | P3 | Restrict access to the roof space in the interim. Remove under controlled conditions by a Class A/B contractor as part of a planned program of works or prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | M33 | - | Air Conditioning Ductwork, Flange Joints & Joins | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | M | MQ2 | Fire Stairs | Fire Door (tagged 'Bismac, 2014') | Core Insulation | Suspected Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R9 | Tramshed | SM | SM47 | Electrical Cupboard, Adjacent Room SM37 | Walls, Ceiling & Door Lining | Fibre Cement Sheeting | Positive | Non-Friable | Low | P3 | Remove ceiling under controlled conditions by a Class A/B contractor as part of a planned program of works or prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | SM | SM47 | - | Air Conditioning Ductwork, Flange Joints & Joins | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | SM | SM47A | Ceiling Space | Air Conditioning Ductwork, Flange Joints & Joins | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | SM | SM47B | Ceiling Space | Air Conditioning Ductwork, Flange Joints & Joins | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | SM | SM47C | Ceiling Space | Air Conditioning Ductwork, Flange Joints & Joins | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | SM | SM47D | Ceiling Space | Air Conditioning Ductwork, Flange Joints & Joins | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | SM | SM47E | - | Air Conditioning Ductwork, Flange Joints & Joins | Mastic Sealant | Positive (chrysotile) | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | SM | SM47F | - | Air Conditioning Ductwork, Flange Joints & Joins | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R9 | Tramshed | SM | SM47G | - | Air Conditioning Ductwork, Flange Joints & Joins | Mastic Sealant | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R13 | Randwick R13 | 01 | - | Former Room M02 | Manhole Cover | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
RANC | Randwick Campus | R13 | Randwick R13 | 01 | - | Exterior, Throughout | Eaves | Fibre Cement Sheeting | Suspected Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R13 | Randwick R13 | 01 | - | Exterior, East and West | Gable Ends | Profiled Fibre Cement Sheeting | Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R13 | Randwick R13 | 01 | 1Q2 | West Side, Above Entry, Surround Steel Beam | Infill Panels | Fibre Cement Sheeting | Assumed Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
RANC | Randwick Campus | R13 | Randwick R13 | 01 | - | Void, North-West & North-East Corners, Surround Steel Beams | Infill Panels | Fibre Cement Sheeting | Positive | Non-Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 16 | 1601 | Goods Lift Motor Room | Wall Duct Grille Penetration | Insulation (white coloured) | Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 16 | - | Communication Room | Fire Door | Core Insulation | Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | Roof | - | Roof | Roof Covering (beneath new membrane) | Bituminous Membrane Remnants | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | - | - | Goods Lift Shaft | Top Surface of Counterweight | Dust | Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | LG | LGQ08 | Redundant Chiller Plant Room | Water Pump, Pipe Valve Flange Joints | Gaskets | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | Yes |
KENC | Kensington Campus | F21 | Library | LG | LGQ08 | Redundant Chiller Plant Room | Chiller Unit | Bituminous Material (on polystyrene insulation) | Removed -Positive (chrysotile) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 23 December 2000. | Yes |
KENC | Kensington Campus | F21 | Library | LG | LGQ08 | Redundant Chiller Plant Room | Chiller Units, Pipework Flange Joints | Gaskets | Removed -Positive (chrysotile) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 23 December 2000. | Yes |
KENC | Kensington Campus | F21 | Library | LG | LGQ08 | Redundant Chiller Plant Room | Chiller Units, Motor Pump Flange Joints | Gaskets | Removed -Positive (chrysotile) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 23 December 2000. | Yes |
KENC | Kensington Campus | F21 | Library | LG | LGQ08 | Redundant Chiller Plant Room | Chiller Units, Air Intake Flange Joints | Mastic Sealant | Removed -Positive (chrysotile) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 23 December 2000. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | 105 | - | Air Conditioning Ductwork Heater Unit | Insulation Board | Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 1 | 105 | - | Air Conditioning Ductwork Heater Unit | Insulation Board | Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 1 | 106 | Records & Archives Room off Room 1Q4 | Fire Door | Core Insulation | Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 1 | 130A | Plant Room | Columns | Insulation (vermiculite) | Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 1 | 130A | Plant Room, Base of Return Air Shaft to Air Handling Unit) | On Soffit, Top of Ductwork & Adjacent Surfaces | Insulation Residue & Debris | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 10 February 2020. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | 180 | Plant Room. South, Above Fire Exit | Air Vents (from Main Service Tunnel) | Moulded Fibre Cement Pipes | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 1 | 180 | Plant Room, Room M1Q01 & M1Q02 | Air Handling Units, Panel Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | 180 | Plant Room, Above Air Handling Units Room M1Q01 & M1Q02 and Shafts | Air Conditioning Ductwork, Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | 180 | Plant Room, North, Adjacent Electrical Cabinet, Below Floor Penetration | Conduit | Moulded Fibre Cement Pipe | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 1 | 180 | Plant Room, North | Inside Electrical Cabinet | Electrical Backing Board | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 8 April 2024. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | 180 | Plant Room, West, Entry Via External Stairs | Fire Doors (tagged ' Bismac 2012) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 1 | 180 | Plant Room, Inside Air Handling Unit | Ceiling (behind perforated metal sheeting) | Insulation (yellow coloured) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 1 | 180 | Plant Room, Above Air Handling Unit | Chilled Water Pipe | Insulation (yellow coloured) | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 1 | 1Q12 | Electrical Room off Fire Stairs (1Q12) | On Soffit Surrounding Column | Insulation Residue | Removed -Positive (chrysotile) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 25 May 2000. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | E1Q01 | Electrical Room off Fire Stairs (1Q12) | On Soffit Surrounding Column | Insulation Overspray / Residue | Removed -Positive (chrysotile) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 25 May 2000. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | E1Q01 | Electrical Room off Fire Stairs (1Q2) | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 26 October 2022. | Yes |
KENC | Kensington Campus | F21 | Library | 1 | - | Old Northern Building Section, Western & Eastern Shafts (North, South & Centre) | General Surfaces & Top of Brick Walls | Suspected Insulation Residue & Debris | Assumed Positive | Friable | Med | P3 | Remove under controlled conditions by a Class A contractor as part of a planned control program. | No |
KENC | Kensington Campus | F21 | Library | 2 | 203 | Northern Library Section, NE Section, Student Lounge, Northern Side (5th window bay from eastern side) | Window | Mastic | Removed -Positive (chrysotile & amosite) | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 17 May 2021. | Yes |
KENC | Kensington Campus | F21 | Library | 2 | 216 | Electrical Room Adjacent Fire Stairs (2Q4) | On Soffit Surrounding Column | Insulation Residue & Bituminous Coating (adhesive) | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 25 May 2000. | Yes |
KENC | Kensington Campus | F21 | Library | 2 | 216 | Electrical Room Adjacent Fire Stairs (2Q4) | Fire Door (tagged ' Bismac Fire Doors, 2023') | Core Insulation | Suspected Negative | - | - | - | - | - |
KENC | Kensington Campus | F21 | Library | 2 | 242 | Electrical Room Adjacent Fire Stairs (2Q16) | Fire Door (tagged ' Bismac Fire Doors, 2023') | Core Insulation | Suspected Negative | - | - | - | - | - |
KENC | Kensington Campus | F21 | Library | 2 | - | Exterior, Façade, Old Low Rise Northern Brick Section | Between Metal Window Framework & Glass | Caulking Mastic (brown colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | - |
KENC | Kensington Campus | F21 | Library | 3 | 305 | Electrical Room Adjacent Fire Stairs (3Q2) | Fire Door (tagged ' Bismac Fire Doors, 2023') | Core Insulation | Suspected Negative | - | - | - | - | - |
KENC | Kensington Campus | F21 | Library | 3 | 322 | Electrical Room Adjacent Fire Stairs (3Q14) | Fire Door (tagged ' Bismac Fire Doors, 2023') | Core Insulation | Suspected Negative | - | - | - | - | - |
KENC | Kensington Campus | F21 | Library | 3 | - | Exterior, Façade, Tower, West Face | Concrete Façade Panel Joints | Sealant Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | - |
KENC | Kensington Campus | F21 | Library | 4 | E4Q02 | Electrical Cupboard Adjacent Fire Stairs (4Q8) | Fire Door (tagged 'Bismac Fire Door, 2023') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F21 | Library | 4 | E4Q17 | Electrical Cupboard Adjacent Fire Stairs (4Q3) | Inside Electrical Cabinets (new appearance electrical cabinet) | Electrical Backing Board | Suspected Negative | - | - | - | - | - |
KENC | Kensington Campus | F21 | Library | 4 | E4Q17 | Electrical Cupboard Adjacent Fire Stairs (4Q3) | Fire Door (tagged 'Bismac Fire Door, 2023') | Core Insulation | Suspected Negative | - | - | - | - | - |
KENC | Kensington Campus | F21 | Library | 11 | - | Roof Above Lounge (roof above former Room 1111, 1113, 1114 & 1115 and Covered Terrace) | Roof Covering (beneath new membrane & concrete topping layers) | Bituminous Membrane | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F21 | Library | 15 | - | Exterior, Perimeter (access via door in NE Fire Stairs (15Q1) | Fire Door | Core Insulation | Negative | - | - | - | - | - |
KENC | Kensington Campus | F23 | Mathews Building | 2 | M2Q01 | Off Room 2Q2 | Wall, Floor & Soffit Expansion Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 301 | Eastern Section, West (former Room 302) Note: Dividing wall between Room 301 & former Room 302 removed | Vertical Expansion Wall Joints | Sealant Mastic | Removed - Positive (chrysotile) | - | - | - | Item Remoced: Refer to RiskTech Compliance Clearance Certificate dated 13 November 2023. | Yes |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 302 | - | Floor Covering | Vinyl Floor Tiles & Amber Adhesive | Negative | - | - | - | - | - |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 306 | All Sides | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q8 | - | On Top of Blockwork Walls & Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | 3Q14 | - | On Top of Blockwork Walls | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 3 | M3Q01 | Off Room 3Q2 | Wall, Floor & Soffit Expansion Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 911 | North | Lower Window (between internal window framework & glazing) | Sealant Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 917 | East | Lower Window (between internal window framework & glazing) | Sealant Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 919 | South | Lower Window (between internal window framework & glazing) | Sealant Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 9 | 927 | South | Lower Window (between internal window framework & glazing) | Sealant Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1104 | North | Lower Window (between internal & external window framework & glazing) | Sealant Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1123 | South | Lower Window (between internal window framework & glazing) | Sealant Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 11 | 1125 | South | Lower Window (between internal & external window framework & glazing) | Sealant Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1326 | - | Fire Panel Above Door | Core Insulation | Assumed Positive | Friable | Low | P3 | Remove fire panel by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 12 | 1327 | - | Fire Panel Above Door | Core Insulation | Assumed Positive | Friable | Low | P3 | Remove fire panel by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1502 | South | Lower Window (between internal window framework & glazing) | Sealant Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1506 | North | Lower Window (between internal & external window framework & glazing) | Sealant Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1507 | North | Lower Window (between internal window framework & glazing) | Sealant Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 15 | 1510 | South | Lower Window (between internal window framework & glazing) | Sealant Mastic | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1621 | South | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1624B | South (Former Room 1626) | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1624E | South (Former Room 1627) | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1628 | Service Duct Entry | Fire Door | Core Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to Greencap-NAA Clearance Certificate dated 16 March 2015 (Ref: J131981.002). Removed by Pure Contracting. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1628 | Service Duct Entry | Fire Door (tagged 'TDF, 2015') | Core Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1628 | Service Duct Adjacent Room 1628 | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1631 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1633 | North | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1633 | Former Room 1604 | Air Conditioning Ductwork Heater Unit | Millboard Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 1635 | - | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 16 | 16Q4 | North | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F23 | Mathews Building | 17 | 1704 | Cooling Tower Room | Floor & Support Structures (beneath cooling tower / plant concrete support structures & plinths) | Bituminous Membrane | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 105 | - | Windows - Gap Between Internal Window Framework & Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 105 | - | Corner Gap of Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 1 | 133 | Western End, Beneath Fume Cupboards (stored in plastic tubs) | Floor Surface Adjacent & Beneath Stored Heat Resistant Mats | Dust | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 203 | - | Windows - Gap Between Internal Window Framework & Glass | Mastic Sealant | Negative | - | - | - | - | - |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 203 | - | Windows - Gap Between Internal Window Framework & Ceramic Wall Tiles | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 203 | - | Corner Gap of Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 203A | - | Windows - Gap Between Internal Window Framework & Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 203A | - | Corner Gap of Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 2 | 203 | - | Windows - Gap Between External Window Framework & Glass | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 303 | - | Fume Cupboard FC303/1-F10, Internal Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 303 | - | Fume Cupboard FC303/2-F10, Base Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 305 | - | Windows - Gap Between Internal Window Framework & Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 305 | - | Corner Gap of Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 305A | - | Windows - Gap Between Internal Window Framework & Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 305A | - | Corner Gap of Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 3 | 307 | - | Fume Cupboard FC307-F10, Ceiling & Internal Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 406 | - | Corner Gaps Between Ceramic Wall tiles | Mastic Sealant | - | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 406 | - | Corner Gaps Between Ceramic Wall tiles | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 406 | - | Gap Between Granite Panels & Granite Panels & Ceramic Wall tiles Behind Sink Area | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 406 | - | Windows - Gap Between Internal Window Framework & Ceramic Wall tiles | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 406A | - | Windows - Gap Between Internal Window Framework & Ceramic Wall tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 406A | - | Corner Gaps Between Ceramic Wall tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 4 | 406 | - | Windows - Gap Between External Window Framework & Glass | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 503 | Riser West off Room 503 & 503A | On Floor, Debris | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 503A | - | Windows - Gap Between Internal Window Framework & Ceramic Wall Tiles | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 5 | 503A | - | Corner Gap of Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 601 | - | Fume Cupboard, FC601/3-F10, Base Lining of Floor of Storage Cupboard Beneath Fume Cupboard | Fibre Cement Sheeting | - | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 22 November 2021. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 601 | - | Fume Cupboard, FC601/2-F10, Base Lining of Floor of Storage Cupboard Beneath Fume Cupboard | Fibre Cement Sheeting | - | - | - | - | Item Removed: Refer to RiskTech Compliance Clearance Certificate dated 22 November 2021. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 601 | Beneath Removed Fume Cupboards | Floor Covering | Vinyl Tiles (olive green) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 601 | Beneath Removed Fume Cupboards | Floor Covering | Adhesive (attached to vinyl tile) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 604 | - | Windows - Gap Between Internal Window Framework & Ceramic Wall Tiles | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 604 | - | Corner Gap of Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 604A | - | Windows - Gap Between Internal Window Framework & Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 6 | 604A | - | Corner Gap of Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | RL1 | R1Q01 | Exterior, Throughout, Trafficable Roof Area | Roof Floor Covering (below concrete pavers) | Bituminous Membrane | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | RL1 | R1Q01 | Exterior, Adjacent Room R2, Ceiling | Infill Panels | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | RL1 | R1Q01 | Exterior, Adjacent Room R1, Ground Surface | Expansion Joints (between concrete pavers) | Bituminous Membrane | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | RL1 | RQ03 | Fire Stairwell | Fire Doors (tagged 'Bismac 2016') | Core Insulation | Suspected Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | RL1 | R2 | Ceiling, Lift Motor Room Hatch | Hatch Door | Insulation Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | RL1 | R1 | Western End, Plant Room | Hot Water Pipework (steam header) | Gasket | Removed -Positive | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | RL1 | R1 | Eastern Plant Room | Compressed Air Pipework | Gasket | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | RL1 | R1 | Plant Room Entrance | Fire Door (tagged 'Wormald 200_') | Core Insulation | Suspected Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | RL1 | R3 | Electrical Cupboard | Inside Electrical Cabinet | Electrical Backing Board | - | - | - | - | Item Removed: System upgraded. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | RL2 | R5 | Lift Motor Room, Entrance | Fire Door (tagged 'Bismac 2016') | Core Insulation | Suspected Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | RL2 | R2Q03 | Room Adjacent Lift Motor Room off Fire Stairwell | Fire Door | Core Insulation (tagged 'Bismac 2012) | Suspected Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | RL2 | R2Q03 | Fire Stairwell to Upper Roof Level | Fire Door | Core Insulation (tagged 'Wormald 201-) | Suspected Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | RL2 | R5 | Exterior, Central Roof Area, Above Lift Motor Room & Stairs | Roof Floor Covering | Bituminous Membrane (asbestos felt membrane has been covered with a new membrane layer) | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | RL2 | R5 | Exterior, Central Roof Area, Above Lift Motor Room & Stairs | Roof Floor Covering | Membrane (above asbestos felt membrane ha) | - | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | - | Exterior, Façade | Façade Spandrel Panel Brackets (within concrete panels) | Insulation | Suspected Positive | Friable | Low | P3 | Confirm status of insulation material to spandrel brackets under controlled conditions and if positive, consider removal under controlled conditions by a Class A contractor prior to any works that may impact upon the material. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 7Q6 | - | Floor Covering | Vinyl Tiles (olive green) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 7Q6 | - | Floor Covering | Adhesive (attached to vinyl tile) | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 702 | - | Windows - Gap Between Internal Window Framework & Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 702 | - | Corner Gap of Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 702A | - | Windows - Gap Between Internal Window Framework & Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 702A | - | Corner Gap of Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 7 | 702A | East Side | Enclosure | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 803 | - | Gap Between Internal Metal Window Framework & Ceramic Wall Tiles | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 803 | - | Gap Between External Metal Window Framework & Brick Wall | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 803 | - | Corner Gap of Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 803A | - | Gap Between Internal Metal Window Framework & Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 803A | - | Corner Gap of Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 803 | - | Gap Between Glass & Internal Window Framework | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 803 | - | Gap Between Glass & External Window Framework | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 821 | (Previously Rooms 817, 818, 819 B-L) Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Removed - Assumed Positive | - | - | - | Item Removed: No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | F10 | Chemical Sciences | 8 | 821 | (Previously Rooms 817, 818, 819 B-L) Under New Flooring Covering | Floor Covering | Adhesive (may be present below new floor covering) | Assumed Positive | Non-friable | Low | P4 | Confirm absence of adhesive below floor covering prior to any works that may impact the area. If adhesive is confirmed, maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 904 | - | Windows - Gap Between Internal Window Framework & Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 904 | - | Corner Gap of Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 904A | - | Windows - Gap Between Internal Window Framework & Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 9 | 904A | - | Corner Gap of Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | 1004 | - | Windows - Gap Between Window Framework & Ceramic Wall Tiles | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | 1004 | - | Windows - Gap Between Internal Window Framework & Ceramic Wall Tiles | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | 1004 | - | Windows - Gap Between Internal Window Framework & Glass | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | 1004 | - | Gap Between Granite Panels & Granite Panels & Ceramic Walls Tiles Behind Sink Area | Mastic Sealant | Negative | - | - | - | - | - |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | 1004 | - | Corner Gaps Between Ceramic Wall tiles | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | 1004 | - | Corner Gaps Between Ceramic Wall tiles | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | 1004A | - | Windows - Gap Between Internal Window Framework & Ceramic Wall Tiles | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F10 | Chemical Sciences | 10 | 1004A | - | Corner Gaps Between Ceramic Wall tiles | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J12 | Newton | - | - | Exterior, East & West Sides of Building | Gap Between Window Framework & Façade Walls | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J12 | Newton | - | - | Exterior, East & South Sides of Building | Wall Expansion Joints | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J12 | Newton | G | - | Exterior, East Side of Building, Entrance to Electrical Switch Room (Room G03) | Wall Expansion Joints Around Door Frame | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J12 | Newton | G | G08B | - | Duct Work Heater Bank | Millboard Insulation Board | Assumed Negative | - | - | - | - | N/A |
KENC | Kensington Campus | J12 | Newton | 2 | W216 | Roof Area, Off Room 2Q7 | Fire Door (tagged 'BETA CORE Door Assembly, 199-') | Insulation Core | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | J12 | Newton | 2 | W217 | Roof Area, Off Room 2Q7 | Fire Door (tagged 'BETA CORE Door Assembly, 199-') | Insulation Core | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | J14 | Keith Burrows Theatre | G | G5 | East, West & North Sides (suspected behind metal cover plates and wall panelling) | Vertical Wall Expansion Joints | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Confirm potential presence of an asbestos mastic sealant in vertical wall expansion joints behind metal cover plates & wall panelling and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J14 | Keith Burrows Theatre | G | G5 | South East Exit | Fire Door (no tag) | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | J14 | Keith Burrows Theatre | G | GQ1 | North & West Sides | Vertical Wall Expansion Joints | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J14 | Keith Burrows Theatre | G | GQ2 | North & East Sides | Vertical Wall Expansion Joints | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J14 | Keith Burrows Theatre | 01 | - | Roof Space, East, West & North Sides (suspected behind metal cover plates) | Vertical Wall Expansion Joints | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Confirm potential presence of an asbestos mastic sealant in vertical wall expansion joints behind metal cover plates and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | J18 | Willis Annex | 1 | - | Exterior, East Side of Building | Wall Expansion Joints x 6 Joints | Mastic Sealant | Removed -Positive (Chrysotile) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 26 July 2022 | Yes |
KENC | Kensington Campus | J18 | Willis Annex | 2 | 202 | North Section of Room, Below & Attached to Pressure Tanks - Small Localised Pipe Section | Pipe Work Flange Joints | Gaskets | Removed -Positive (Chrysotile) | - | - | - | Item Removed: Refer to RiskTech Clearance Certificate dated 7 November 2018 | Yes |
KENC | Kensington Campus | J18 | Willis Annex | M | 2Q12 & 2Q13 | Hallway Passage | Fire Doors (tagged 'Exodus Doors, 2015') | Insulation Core | Suspected Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | LG | LGQ17 | North-West | Fire Door (tagged 'Trafalgar, 2005') | Core Insulation | Suspected Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | G | - | Exterior, North Side, outside GQ18 | Windows (between frame and brick facade) | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P3 | Remediate (remove and/or seal) deteriorating mastic sealant under controlled conditions by a Class A/B contractor within a planned control program. | No |
KENC | Kensington Campus | K15 | Old Main | G | - | Exterior | Windows (between frame and brick facade) | Mastic Sealant | Assumed Positive | Non-friable | Low | P3 | Remediate (remove and/or seal) deteriorating mastic sealant under controlled conditions by a Class A/B contractor within a planned control program. | No |
KENC | Kensington Campus | K15 | Old Main | G | - | Exterior, South Side, Outside Room G50 | Windows (between frame and pane) | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | G | - | Exterior, North Side, Outside Room GQ18 | Windows (between frame and pane) | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 01 | - | Exterior, South Side, Outside Room 148A, Right Side Window | Windows (between frame and pane) | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K15 | Old Main | 01 | - | Exterior, South Side, Outside Room 148A, Left Side Window 7 & Top Left & Right Windows | Windows (between frame and pane) | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 01 | - | Exterior, South Side, Outside Room 148 | Windows, Between Window Framework & Glazing) | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment | No |
KENC | Kensington Campus | K15 | Old Main | 01 | - | Exterior, North Side, Outside Room 1Q18 | Windows (between frame and brick facade) | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P3 | Remediate (remove and/or seal) deteriorating mastic sealant under controlled conditions by a Class A/B contractor within a planned control program. | No |
KENC | Kensington Campus | K15 | Old Main | 01 | - | Exterior | Windows (between frame and brick facade) | Mastic Sealant | Assumed Positive | Non-friable | Low | P3 | Remediate (remove and/or seal) deteriorating mastic sealant under controlled conditions by a Class A/B contractor within a planned control program. | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 103 | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 103 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 104 | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 104 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 112 | - | Floor Covering | Vinyl Tiles (light grey colour) | - | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 01 | 112 | - | Floor Covering | Adhesive | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 01 | 1Q9 | Electrical Cupboard | Floor Covering | Vinyl Tiles (grey colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment | No |
KENC | Kensington Campus | K15 | Old Main | 02 | - | Interior, Throughout | Windows (between frame and pane) | Mastic Sealant | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K15 | Old Main | 02 | - | Lift Motor Room, Throughout | Ceiling | Fibre Cement Sheeting | Suspected Positive (Removed) | - | - | - | Item Removed. No removal/clearance documentation was provided. | Yes |
KENC | Kensington Campus | K15 | Old Main | 02 | - | Lift Motor Room, North | Window Frames | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K15 | Old Main | 02 | 2Q9 | West | Fire Door (tagged 'Fyrecon and Inglis 1990') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D16 | Goldstein Hall | G | - | Exterior, North | Base or Floor of Pond, Underside of Ceramic Tiles | Cementitious Material | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D16 | Goldstein Hall | G | - | Exterior, North | Base or Floor of Pond, Expansion Joints | Mastic | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D16 | Goldstein Hall | G | GQ13 | Main Switch Room | On Ground & General Surfaces (insulation source from fire stop pillow in wall penetration) | Insulation Debris | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D16 | Goldstein Hall | 02 | M2Q01 | Exterior, Roof Plant Area | Roof Covering | Bituminous Membrane (may be present beneath new membrane) | Suspected Positive | Non-friable | Low | P4 | Confirm potential presence of an asbestos membrane layer beneath new membrane layer and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D16 | Goldstein Hall | 02 | - | Exterior, Roof Area | Roof Covering | Bituminous Membrane (may be present beneath metal roof sheeting) | Suspected Positive | Non-friable | Low | P4 | Confirm potential presence of an asbestos membrane layer beneath metal roof sheeting and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H22 | Valentine Annexe | G | - | Exterior, North Side | Window Frames (gap between window frame & wall sill) | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P3 | Remediate (remove and/or seal) deteriorating mastic sealant under controlled conditions by a Class A/B contractor within a planned control program. | No |
KENC | Kensington Campus | H22 | Valentine Annexe | G | - | Exterior, South Side | Window Frames (gap between window frame & wall sill) | Mastic Sealant | Assumed Positive | Non-friable | Low | P3 | Remediate (remove and/or seal) deteriorating mastic sealant under controlled conditions by a Class A/B contractor within a planned control program. | No |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G13 | Western End | Ductwork Joins | Mastc Sealant | Removed -Assumed Positive | - | - | - | Item Removed by Pure Contracting. Refer to RiskTech Compliance Clearance Certifcate Report dated 15 August 2022. | Yes |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G13E | - | Floor Covering | Vinyl Tiles (Light Brown/Beige & Light Grey) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H22 | Valentine Annexe | G | G14 | East Section | Supply Fan & Ductwork Joints | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H22 | Valentine Annexe | 1 | - | Exterior, North Side | Window Frames (gap between window frame & wall sill) | Mastic Sealant | Assumed Positive | Non-friable | Low | P3 | Remediate (remove and/or seal) deteriorating mastic sealant under controlled conditions by a Class A/B contractor within a planned control program. | No |
KENC | Kensington Campus | H22 | Valentine Annexe | 1 | - | Exterior, South Side | Window Frames (gap between window frame & wall sill) | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P3 | Remediate (remove and/or seal) deteriorating mastic sealant under controlled conditions by a Class A/B contractor within a planned control program. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 01 | 103 | Room West of Stairwell | Inside Electrical Cabinet - Backing Board | Fibre Cement Sheeting | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 01 | 1Q1 | Stairwell, Exterior, South | Windows (between frame and wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 01 | 1Q2 | Stairwell, Exterior, West | Windows (between frame and glazing) | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 01 | 1Q2 | Stairwell, Exterior, West | Windows (between frame and wall) | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 01 | 1Q2 | Stairwell | Fire Door (tagged 'Bismac, 2013') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 02 | 2Q1 | Stairwell, Exterior, South | Windows (between frame and wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 02 | 2Q2 | Stairwell, Exterior, West | Windows (between frame and glazing) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 02 | 2Q2 | Stairwell, Exterior, West | Windows (between frame and wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 03 | 3Q1 | Stairwell, Exterior, South | Windows (between frame and wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 03 | 3Q2 | Stairwell, Exterior, West | Windows (between frame and glazing) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 03 | 3Q2 | Stairwell, Exterior, West | Windows (between frame and wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 04 | 4Q1 | Stairwell, Exterior, South | Windows (between frame and wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 04 | 4Q2 | Stairwell, Exterior, West | Windows (between frame and glazing) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 04 | 4Q2 | Stairwell, Exterior, West | Windows (between frame and wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 05 | 5Q1 | Stairwell, Exterior, South | Windows (between frame and wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 05 | 5Q2 | Stairwell, Exterior, West | Windows (between frame and glazing) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 05 | 5Q2 | Stairwell, Exterior, West | Windows (between frame and wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 06 | 6Q2 | Stairwell, Exterior, West | Windows (between frame and glazing) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 06 | 6Q2 | Stairwell, Exterior, West | Windows (between frame and wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 06 | 6Q4 | - | Upper Wall Panelling (Fascia) & Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | H25 | Botany Street Parking Station | 06 | 6Q4 | East Wall | Enclosure Covering (rear face of power socket) | Insulation Block (vermiculite) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F12 | Dalton | Roof | - | Exterior, Roof Area | Roof Covering | Bituminous Membrane (may be present beneath metal roof sheeting) | Suspected Positive | Non-friable | Low | P4 | Confirm potential presence of an asbestos membrane layer beneath metal roof sheeting and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F17 | Rex Vowels Theatre | G | - | Exterior, West Side, Southern Section (common to Room LGQ2) | Window Frames (gap between window frames & wall) | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F17 | Rex Vowels Theatre | G | - | Exterior, East Side, Southern Section (common to Room LGQ2) | Window Frames (gap between window frames & wall) | Mastic Sealant | Assumed Positive | Non-friable | Low | P3 | Remediate (remove and/or seal) deteriorating mastic sealant under controlled conditions by a Class A/B contractor within a planned control program. | No |
KENC | Kensington Campus | F17 | Rex Vowels Theatre | LG | LG05 | Plant Room | Old Air Conditioning Ductwork Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F17 | Rex Vowels Theatre | LG | LG05 | Plant Room Central, Above Compressor | Air Conditioning Ductwork Heater Bank | Internal Insulation Board | Removed - Positive (Chrysotile & Amosite) | - | - | - | Item Removed - Refer to RiskTech Compliance Asbestos Clearance Certificate dated 19 November 2020. | Yes |
KENC | Kensington Campus | F17 | Rex Vowels Theatre | 1 | LG05 | Plant Room, Mezzanine Level | Old Air Conditioning Ductwork Flange Joints & Joins | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F17 | Rex Vowels Theatre | 1 | LG05 | Plant Room, Mezzanine Level | Wall Divider to Cooling Tower Area | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F17 | Rex Vowels Theatre | 1 | LG05 | Plant Room | Fire Door (tagged ' Robson Doors, 2023' | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 1 | 101 | North, Vertical, Floor to Ceiling Panelling | Wall | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D23 | Mathews Theatres | 1 | 101 | North | Wall Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D23 | Mathews Theatres | 1 | 104A | Male Toilets | On Top of Brick Walls | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D23 | Mathews Theatres | 1 | 105 | Toilet Plumbing Duct | Redundant Flue Duct, Joins | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P3 | Remove under controlled conditions by a Class A/B contractor as part of planned program of works or prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 1 | 105 | Toilet Plumbing Duct | Air Conditioning Ductwork Joins | Mastic Sealant | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 1 | 105A | Exhaust Duct off Room 105A (Female Toilets), Entry | Fire Door | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 1 | 105A | Female Toilets | On Top of Brick Walls | Mastic Sealant | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 1 | 150 | Plant Room, Electrical Cupboard off Store | Fire Doors (tagged 'Holland, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 1 | 1Q1 | Arcade, South Side, SE Corner | Vertical Expansion Joint Between Column & Wall | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D23 | Mathews Theatres | 1 | 1Q1 | Arcade, North & South Sides | Wall & Column Vertical Expansion Joints | Mastic Sealant | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 1 | 1Q1 | Arcade, North & South Sides | On Top of Brick Walls | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 1 | 1Q1 | Arcade, East Side | Soffit Expansion Joint (Note: suspected behind metal cover) | Mastic Sealant | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 1 | 1Q3 | Fire Stairs from Plant Room 150 to Arcade | On Top of Brick Walls (suspected beneath new mastic on wall sections) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 2 | 201 | SE & SW Entries | Fire Doors (tagged 'Holland, 1999 and Wormald, no date') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D23 | Mathews Theatres | 2 | 203 | NE Entry | Fire Door (tagged 'Holland, 1999') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | - | Open Courtyard, North Side, Adjacent Entry to Foodcourt | Wall Expansion Joint | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | - | Open Courtyard, North Side, Adjacent to Entry to Foodcourt | Parapet Wall Expansion Joints | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | - | Open Courtyard, West & South Sides | On Top of Brick Wall Sections | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG01 | Retail Tenancy, Ceiling Space | Air Conditioning Ductwork Joins | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG01 | Retail Tenancy, North Side | Inside Electrical Cabinet & Wall Mounted Board | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG02A | Toilet, Ceiling Space | Air Conditioning Ductwork Joins | Mastic Sealant | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG04 | Cleaners Room, South Side, Surrounding & Above Entry Door | Wall Panelling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG05 | Retail Tenancy, North Side, Entry to Foundation Space | Access Hatch | Solid Timber | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG05 | Female Toilet (Disabled), North Side, Entry to Foundation Space | Access Hatch | Solid Timber | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG07 | Retail Tenancy, East Side | Inside Electrical Cabinet & Wall Mounted Board | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG09 | Store, South Side | Inside Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG10 | Retail Tenancy, South Room, North End | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG10 | Retail Tenancy, South Side | Inside Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG11 | Retail Tenancy, South Side | Inside Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG12 | Retail Tenancy, South Side | Inside Electrical Cabinet & Wall Mounted Board | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG13 | Store | Floor Covering | Vinyl Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG14 | Above Cool Room | Attached to Soffit, Partial Infill of Soffit Penetration | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG15 | Retail Tenancy, South Side | Inside Electrical Cabinet | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG16 | Arcade, Area Outside Toilets & Cleaners Room, Ceiling Space, Above New Plasterboard Ceiling | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG16 | Arcade, Outside Room LG02A & LG11 | Soffit Expansion Joint (Note: mostly covered by metal plate) | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG16 | Arcade, South Side, Adjacent Room LG10 | Wall Expansion Joints | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LG16 | Adjacent Room LG01 & LG02A, Fire Hose Reel Cupboard | Ceiling | Fibre Cement Sheeting | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LGQ1 | Service Corridor Adjacent Room LG15A | Floor Covering | Vinyl Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E24A | Mathews Arcade | LG | LGQ2 | Stairs to Ground Level, Adjacent Entry | Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C24 | Clancy Auditorium | LG | LG1 | - | Ductwork Joints | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C24 | Clancy Auditorium | G | G4A | Female Toilet, Ceiling Space | Ductwork Joints & Joins | Mastic Sealant (red colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. Note: Mastic to ductwork may be present above set ceilings and in other inaccessible locations in the building. | No |
KENC | Kensington Campus | C24 | Clancy Auditorium | G | G6 | Exterior, East of G7A, to Lower Ground Level (Room LG1) | Fire Door (tagged 'Cemac') | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C24 | Clancy Auditorium | G | G17 | Auditorium, West Side | Walls (behind audio wall plate) | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C24 | Clancy Auditorium | G | G18 | Kitchen | Walls (behind ceramic wall tiles) | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C24 | Clancy Auditorium | G | G16 | Entrance | Fire Door (tagged 'Bismac, 1998') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | G | GQ10 | Hydraulic Duct Cupboard | Fire Door (tagged 'Inglis, 1994') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | G | - | Interior, Various Locations, Ceiling Space | Older Ductwork Joints | Mastic Sealant (red/green colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | 2 | - | Exterior, Verandah, North, South & East Sides | Window Frames (between frame & pane) | Mastic Sealant | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | E4 | Squarehouse | 2 | 211 | North Entry off Room 2Q3 | Fire Door | Core Insulation | Suspected Positive | Friable | Low | P3 | Confirm status and if confirmed to contain asbestos, remove by a Class A Contractor within a planned control program. | No |
KENC | Kensington Campus | E4 | Squarehouse | 2 | 215 | - | Floor Covering | Vinyl Tiles & Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E4 | Squarehouse | 3 | 302 | East | Fire Doors (tagged 'Inglis, 1994') | Core Insulation | Suspected Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E4 | Squarehouse | 3 | 3Q4 | Outside Room 310 | Wall Cavity (behind plasterboard wall lining) | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | E4 | Squarehouse | R | R1 | Plant Room, Entry | Fire Door (tagged 'Bismac, 2019') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | E4 | Squarehouse | - | - | Lift Car | Floor Covering | Vinyl Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G6 | Blockhouse | - | - | Roof, Western End, Plant Room (Air Handling Unit) | Eaves | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G15 | Robert Webster Theatres | G | 192 | Plant Room / Store | Ductwork Joints & Joins | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G15 | Robert Webster Theatres | G | 193 | Plant Room | Connector Between Fan Unit & Ductwork | Woven Cloth | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G15 | Robert Webster Theatres | G | 193 | Plant Room | Ductwork Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G15 | Robert Webster Theatres | 1 | - | Exterior, West Side | Window Frames (Between Frame & Outer Metal Boxing) | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G15 | Robert Webster Theatres | 1 | 190 | SW Entrance | Fire Doors (tagged 'Robson Doors, 2024') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G15 | Robert Webster Theatres | 1 | 190A | Lecture Theatre, East Side Projector Room, Ceiling Space & Duct Riser | Ductwork Joints & Joins (behind foil covering) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G15 | Robert Webster Theatres | 2 | 290 | SW Entrance | Fire Doors (door not tagged but door framework tagged 'Wormald, 201-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G15 | Robert Webster Theatres | 2 | 290A | Lecture Theatre B, East Side Projector Room, Duct Riser | Ductwork Joints & Joins (behind foil covering) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G15 | Robert Webster Theatres | 2 | 291 | West, Interior & Exterior | Window Frames (Between Frame and Pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G15 | Robert Webster Theatres | 2 | 292B | - | Flooring Infill Section | Compressed Fibre Cement Sheeting | Negative | - | - | - | - | No |
KENC | Kensington Campus | G15 | Robert Webster Theatres | 2 | 2Q9 | Fire Exit | Fire Doors (tagged 'Cecon, 199-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G15 | Robert Webster Theatres | 2 | - | Roof Space, NW Corner, Mezzanine Plant Area (access via ladder from Room 292B) | Ceiling | Fibre Cement Sheeting | Positive (chrysotile, amosite & crocidolite) | Non-friable | Low | P3 | Remediate (remove and/or repair/seal) damaged ceiling under controlled conditions by a Class A/B contractor within a planned control program. | No |
KENC | Kensington Campus | G15 | Robert Webster Theatres | 1 - 2 | - | Exterior, South Side, SW Corner | Façade Wall Panel Joints | Pointing | Assumed Positive | Non-friable | Med | P3 | Remediate (remove and/or seal) under controlled conditions by a Class A/B contractor within a planned control program. | No |
KENC | Kensington Campus | G15 | Robert Webster Theatres | 1-2 | - | Exterior, South Side, SE Corner | Façade Wall Panel Joints | Pointing (beneath mastic sealant) | Suspected Positive | Non-friable | Low | P4 | Conduct investigation to determine presence and extent of asbestos containing pointing material beneath mastic in façade wall joints prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G15 | Robert Webster Theatres | 2 | - | Exterior, Upper South Side, Above Roof of Stairs | Façade Wall Panel Joints | Pointing | Suspected Positive | Non-friable | Low | P4 | Conduct investigation to determine presence and extent of asbestos containing pointing material in façade wall joints prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G15 | Robert Webster Theatres | 1-2 | - | Exterior, East Side | Façade Wall Panel Joints | Pointing (beneath mastic sealant) | Suspected Positive | Non-friable | Med | P4 | Conduct investigation to determine presence and extent of asbestos containing pointing material beneath mastic in façade wall joints prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G15 | Robert Webster Theatres | 1-2 | - | Exterior, North Side, NE Corner | Façade Wall Panel Joints | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G15 | Robert Webster Theatres | 1 | - | Exterior, North Side, NE Corner | Façade Wall Panel Joint | Pointing | Positive (chrysotile) | Non-friable | Med | P3 | Remediate (remove and/or seal) under controlled conditions by a Class A/B contractor within a planned control program. | No |
KENC | Kensington Campus | G15 | Robert Webster Theatres | 1-2 | - | Exterior, North Side, NE Corner | Façade Wall Panel Joints | Pointing (beneath mastic sealant) | Suspected Negative | Non-friable | Med | P4 | Conduct investigation to determine presence and extent of asbestos containing pointing material beneath mastic in façade wall joints prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G15 | Robert Webster Theatres | 1-2 | - | Exterior, North Side, Void Cavity Area Between Building & Building E15 | Façade Wall Panel Joints | Pointing | Suspected Positive | Non-friable | Low | P4 | Conduct investigation to determine presence and extent of asbestos containing pointing material in façade wall joints prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K14 | Physics Theatre | G | - | Exterior, Western Entry, Top of Stairs | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K14 | Physics Theatre | LG | LG11B | - | Floor Covering | Vinyl Tiles (grey colour) | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K14 | Physics Theatre | LG | LG11B | Mid East Side, Service Tunnel (via small access door) | Conduilts | Moulded Fibre Cement Pipes | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K14 | Physics Theatre | LG | LG15A | - | Floor Covering | Vinyl Floor Sheeting (blue colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K14 | Physics Theatre | LG | LG16 | Plant Room | Air Handling Unit, Joins | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K14 | Physics Theatre | LG | LG16 | Plant Room | Air Conditioning Ductwork, Flange Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K14 | Physics Theatre | LG | LGQ13 | - | Fire Doors (tagged 'Robson Doors, 2023') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K14 | Physics Theatre | G | G19 | NW, NE & SE Entrances | Fire Doors (tagged 'Radiant Enterprise, Cecon, 199_' & Wormald, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K14 | Physics Theatre | G | G27 | - | Floor Covering | Vinyl Floor Sheeting (aqua green colour) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K14 | Physics Theatre | G | GQ7 | - | Fire Door (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K14 | Physics Theatre | 1 | 164 | - | Fire Door (no tag) | Core Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K14 | Physics Theatre | 1 | 164 | Roof Space Access via Room 164 | Fire Door (tagged 'Wormald, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K14 | Physics Theatre | 1 | - | Roof Space | Electrical Cabinet | Electrical Backing Board | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K14 | Physics Theatre | 1 | - | Exterior, South Roof Area | Roof Covering | Bituminous Membrane (may be present beneath new membrane) | Suspected Positive | Non-friable | Low | P4 | Confirm potential presence of an asbestos membrane layer beneath new membrane layer and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K14 | Physics Theatre | 1 | RQ02 | Exterior, North Roof Area | Roof Covering | Bituminous Membrane (may be present beneath new membrane) | Suspected Positive | Non-friable | Low | P4 | Confirm potential presence of an asbestos membrane layer beneath new membrane layer and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K14 | Physics Theatre | 1 | RQ03 | Exterior, Mid East Roof Area | Roof Covering | Bituminous Membrane (may be present beneath new membrane) | Suspected Positive | Non-friable | Low | P4 | Confirm potential presence of an asbestos membrane layer beneath new membrane layer and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F22 | Bank | - | - | Exterior, Eastern Side, Mid Section | Window Frames (between frame and brick wall sill) | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C6 | International House | 1 | 181 | Accommodation Room, Deans Unit, Undercover Enclosed Awning (UECA) / Balcony | Eaves | Fibre Cement Sheeting ('dimpled' but new appearance sheet) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C6 | International House | 1 | 181 | Accommodation Room, Deans Unit, Undercover Enclosed Awning (UECA) / Balcony | Eaves | Fibre Cement Sheeting ( new appearance sheet) | Negative | - | - | - | - | N/A |
FSFG | Fowlers Gap Field Station | - | Old Waste Storage Area | - | - | Old Waste storage area | Ground Surface beneath removed stored metal items. | Fibre Cement Sheet Debris | Positive (chrysotile) | - | - | - | Removed between 26/08/2024 to 31/08/2023 as per Asbestos Clearance Certificate dated 03/09/2024 | Yes |
KENC | Kensington Campus | E26 | Biological Sciences South | G | G005 | Ground Level, Room G005 Workstation | - | Dust and debris material | Positive (chrysotile) | - | - | - | Removed on 23/08/2024 as per Asbestos Clearance Certificate dated 23/08/2024 | Yes |
KENC | Kensington Campus | C6 | International House | 3 | 3Q3 | Corridor Outside Room 392 | On Concrete Floor (beneath carpet) | Backing Material & Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C6 | International House | 3 | 3Q10 | Corridor Outside Room 314 | On Concrete Floor (beneath carpet) | Backing Material & Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F13 | Science Theatre | LG | LG1B | Boiler Room | Fire Doors | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F13 | Science Theatre | LG | LGQ1 | - | Fire Door (tagged 'Radiant, no date') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G01 | South | Window Frames (between frame & pane) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F13 | Science Theatre | G | G08 & G08A | East, Cupboard | Attached to Nail Heads on Timber Wall Framework and Wedged Between Timber Wall & Ceiling Framework | Fibre Cement Sheet Remnants | Removed: Assumed Positive | - | - | - | Item Removed. Refer to Risktech Compliance Asbestos Clearance Certificate dated 12 February 2024. | Yes |
KENC | Kensington Campus | F13 | Science Theatre | G | G16 | Stage Left | Flue | Woven Cloth Covering (beneath metal sheet covering) | Removed: Negative | - | - | - | - | Yes |
KENC | Kensington Campus | F13 | Science Theatre | G | G18 | Stage Right | Fire Doors (tagged 'Tyco, 1997') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F13 | Science Theatre | G | GQ10 | - | Fire Door (tagged 'Wormald, 20--') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F13 | Science Theatre | 2 | - | Above Stage, Roof Space | Wall Panelling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | LG | LGQ11 | South Entry | Fire Door (tagged 'Robson Doors, 202-') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D26 | Bio Sciences North | LG | LGQ11 | Adjacent Room LGQ06 | Fire Door (tagged 'Ikon Door', no date) | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D26 | Bio Sciences North | LG | LGQ12 | North | Fire Door (tagged 'Ikon Door', no date) | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D26 | Bio Sciences North | LG | LGQ13 | West | Fire Door (tagged 'Ikon Door', no date) | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D26 | Bio Sciences North | LG | ELGQ01 | Biolink, Former Room LG25 | Fire Door | Insulation Core | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. Note: New fire door tagged 'Ikon Door - Manufactured 201-'. | Yes |
KENC | Kensington Campus | D26 | Bio Sciences North | LG | ELGQ01A | Biolink, Former Room LG24A | Inside Electrical Distribution Cabinets | Electrical Backing Boards | Removed - Suspected Positive | - | - | - | Item Removed: No removal / clearance documentation provided. Note: New switchboard electrical cabinets. | Yes |
KENC | Kensington Campus | D26 | Bio Sciences North | LG | ELGQ01A | Biolink, Former Room LG24A | Fire Door | Insulation Core | Removed - Assumed Positive | - | - | - | Item Removed: No removal / clearance documentation provided. Note: New fire door tagged 'Ikon Door - Manufactured 201-'. | Yes |
KENC | Kensington Campus | D26 | Bio Sciences North | LG | - | Biolink, Perimeter Façade Walls (behind concrete wall section & behind infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | LG | - | Biolink, Throughout | Old Air Conditioning Ductwork - Flange Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | LG | - | Biolink, Throughout | Steel Beams | Insulation | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | D26 | Bio Sciences North | LG | - | Biolink, Exterior, Façade, Throughout | Between Window Frame & Glass | Mastic Sealant | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | LG | - | Biolink, Exterior, Façade, Throughout | Window Framework & Concrete Façade Panel Joints | Sealant Mastic | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | G | G20 | Biolink, NW Riser, West Side (behind plasterboard sheeting) | Wall | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | G | G23 | Biolink, Perimeter Façade Walls (behind concrete wall sections & behind infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | G | G23 | Biolink, South | Packers Beneath Timber Stud Wall (localised areas) | Fibre Cement Sheeting | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 10 September 2021. | Yes |
KENC | Kensington Campus | D26 | Bio Sciences North | G | G23A | Biolink | On Concrete Slab (beneath vinyl floor tiles) | Adhesive | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 10 September 2021. | Yes |
KENC | Kensington Campus | D26 | Bio Sciences North | G | G23B | Biolink | On Concrete Slab (beneath vinyl floor tiles) | Adhesive | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 10 September 2021. | Yes |
KENC | Kensington Campus | D26 | Bio Sciences North | G | G27B | Biolink, East | Wall | Fibre Cement Sheeting | Removed - Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 10 September 2021. | Yes |
KENC | Kensington Campus | D26 | Bio Sciences North | 1 | 130 | Biolink | On Concrete Floor Slab (beneath floor covering) | Bituminous Adhesive | Removed - Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 30 October 2020. | Yes |
KENC | Kensington Campus | D26 | Bio Sciences North | 1 | 131A | Biolink, Perimeter Façade Walls (behind concrete wall sections & behind infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 1 | 132 | Biolink | Window Framework - Gap Between Internal Window Frame & Glazing | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D26 | Bio Sciences North | 1 | 132 | Biolink | Window Framework - Gap Between External Window Frame & Glazing | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D26 | Bio Sciences North | 1 | 132A | Biolink, Area Above Cool Room (access via Room 132B ceiling space) | Fire Door | Insulation Core | Removed -Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 28 September 2021. | Yes |
KENC | Kensington Campus | D26 | Bio Sciences North | 1 | 137 | Biolink | On Concrete Floor Slab (beneath vinyl sheeting) | Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D26 | Bio Sciences North | 1 | 137A | Biolink | Window Framework - Gap Between Internal Window Frame & Glazing | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D26 | Bio Sciences North | 1 | 137A | Biolink | On Concrete Floor Slab (beneath vinyl sheeting) | Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D26 | Bio Sciences North | 1 | 137B | Biolink | Window Framework - Gap Between Internal Window Frame & Glazing | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D26 | Bio Sciences North | 1 | 137B | Biolink | Window Framework - Gap Between External Window Frame & Glazing | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D26 | Bio Sciences North | 1 | 137B | Biolink | On Concrete Floor Slab (beneath vinyl sheeting) | Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D26 | Bio Sciences North | 1 | 137C | Biolink | On Concrete Floor Slab (beneath vinyl sheeting) | Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q12 | Biolink, East (common to Room 131) | Wall | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q12 | Biolink, East (common to Room 132, 132A, 132B & 134) & West (common to Room138, 138A, 140, 141, 141A, 142 & 142A) | Walls | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 28 September 2021. | Yes |
KENC | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q13 | Biolink, Fire Stairs | Fire Door (tagged 'Inglis, 1990') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 1 | 1Q17 | Biolink, North Entry | Fire Door (tagged 'Radiant, 2020') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 2 | 257 | Biolink, Perimeter Façade Walls (behind concrete wall sections & behind infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 2 | 259 | Biolink, West (wall common to Room 261 & 262) | Wall | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Seal damaged areas to walls in ceiling space. Remediate under controlled conditions by a Class A/B contractor as part of a planned control program or remove prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 2 | 261 | Biolink, West (wall common to Room 259 behind non-asbestos fibre cement sheeting) | Wall | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 2 | 262 | Biolink, West (wall common to Room 259 behind non-asbestos fibre cement sheeting) | Wall | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 2 | 263 | Biolink, Perimeter Façade Walls (behind concrete wall sections & behind infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 2 | 2Q7 | Biolink, Electrical Riser Cupboard | On Ground Surface | Insulation Debris | Removed - Positive (chrysotile) | - | - | - | Removed by RiskTech Compliance as part of inspection proces. | Yes |
KENC | Kensington Campus | D26 | Bio Sciences North | 2 | 2Q7 | Biolink, North | Fire Door (tagged 'Inglis, 1990') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 3 | 301B | Biosciences North | Fume Cupboard, Internal Lining | Fibre Cement Sheeting | Removed - Positive | - | - | - | Item Removed: No removal / clearance documentation provided. | Yes |
KENC | Kensington Campus | D26 | Bio Sciences North | 3 | 340 | Biolink | Fire Door (tagged 'Bismac, 202-') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 3 | 341 | Biolink, West Wall Common to Room 340 | Wall | Fibre Cement Sheeting | Positive | Non-friable | Low | P3 | Seal damaged areas to walls in ceiling space. Remediate under controlled conditions by a Class A/B contractor as part of a planned control program or remove prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 3 | 341 | Biolink, External Face of West, East & South Walls Common to Room 340 | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Seal damaged areas to walls in ceiling space. Remediate under controlled conditions by a Class A/B contractor as part of a planned control program or remove prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 3 | 341 | Biolink, Perimeter Façade Walls (behind concrete wall sections & behind infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 4 | 448B | Biolink, North, NW Corner Perimeter Façade Wall (behind removed wall panelling) | Spandrel Brackets | Insulation | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 17 December 2021. | Yes |
KENC | Kensington Campus | D26 | Bio Sciences North | 4 | 458 | Biolink | Fire Door (tagged ' Bismac, 202-') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 4 | 459 | Biolink, South, East & West, Perimeter Façade Walls (behind lower concrete wall sections & infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 4 | 459 | Biolink, West Wall Common to Room 458 | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 4 | 459 | Biolink, External Face of East & South Walls Common to Room 458 | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Seal damaged areas to walls in ceiling space. Remediate under controlled conditions by a Class A/B contractor as part of a planned control program or remove prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 4 | 459 | Biolink, Walls Common to Overhead Bridge to Samuel Building (F25) | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 5 | 551 | Biolink | Window Framework - Gap Between Internal Window Frame & Glazing | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D26 | Bio Sciences North | 5 | 551 | Biolink | Window Framework - Gap Between External Window Frame & Glazing | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D26 | Bio Sciences North | 5 | 554 | Biolink | Window Framework - Gap Between External Window Frame & Glazing | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D26 | Bio Sciences North | 5 | 554 | Biolink | Window Framework - Gap Between Internal Window Frame & Glazing | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D26 | Bio Sciences North | 5 | 569 | South & East | Walls | Fibre Cement Sheeting | Removed -Assumed Positive | - | - | - | Item Removed: Refer to RiskTech Compliance Asbestos Clearance Certificate dated 2 February 2022. | Yes |
KENC | Kensington Campus | D26 | Bio Sciences North | 5 | 573 | Biolink | Drainage Pipe | Moulded Fibre Cement Pipe | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 5 | 574 | Biolink, West Wall Common to Room 458 | Wall | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Seal damaged areas to walls in ceiling space. Remediate under controlled conditions by a Class A/B contractor as part of a planned control program or remove prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 5 | 574 | Biolink, External Face of East, West & South Walls Common to Room 573 | Walls | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P3 | Seal damaged areas to walls in ceiling space. Remediate under controlled conditions by a Class A/B contractor as part of a planned control program or remove prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 5 | 574 | Biolink, South, East & West, Perimeter Façade Walls (behind lower concrete wall sections & infill wall panelling) | Spandrel Brackets | Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 5 | 574 | North Entry | Fire Door (tagged 'Inglis, 1990') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | BS30 | 30 Botany Street | G | G14 | - | Ceiling | Fibre Cement Sheeting | Positive (Chrysotile) | Non Friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | BS30 | 30 Botany Street | 1 | 114 | (Access ceiling via roof space) | Ceiling | Cementitious Materials on Timber Lathe | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | D26 | Bio Sciences North | 6 | R01 | North Entry to Roof RQ01 | Fire Door (tagged 'Gosford Fire Doors, 2010') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 6 | RQ01 | Roof | Roof Covering (assumed beneath new membrane or concrete toppings) | Bituminous Membrane | Suspected Positive | Non-friable | Low | P4 | Confirm status and if confirmed present and contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | D26 | Bio Sciences North | 6 | RQ01 | Roof | External Walls of Plant Room | Bituminous Coating | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F13 | Science Theatre | G | - | Covered Walkway South of Science Theatre | Roof membrane | Floor Covering | Positive | - | - | - | Item removed as per Risktech Asbestos Clearance Certificate dated 12/02/2024. | Yes |
COFA | Paddington Campus | CFAE | Block E | B | EB04 | Basement Room | Pipe chased in the brick wall | Pipe Insulation | Positive | - | - | - | Item removed as per Risktech Asbestos Clearance Certificate dated 28/02/2024. | Yes |
KENC | Kensington Campus | N8 | House at Pooh Corner | - | - | Exterior, East Side, Near North End | Eaves | Fibre Cement Sheeting | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | - | - | Exterior, East & South Sides Note: various eaves sections appear to have been replaced with new fibre cement sheeting | Eaves | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Consideration should be given to undertake further investigation to determine the locations and extent of asbestos containing fibre cement sheet lined eaves prior to demolition, refurbishment & maintenance. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | - | - | Exterior, North Side | Covered Awning Ceiling | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Consideration should be given to undertake further investigation to determine the locations and extent of asbestos containing fibre cement sheet lined awning ceiling prior to demolition, refurbishment & maintenance. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | N8 | House at Pooh Corner | - | - | Exterior, East Side, Near North End | On Ground, Debris | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | N8 | House at Pooh Corner | - | - | Exterior, East Side | On Air Conditioning Compressor Unit, Debris | Fibre Cement Sheeting | Removed - Positive (chrysotile) | - | - | - | Item Removed: RiskTech Compliance removed item as part of inspection & sampling process. | Yes |
KENC | Kensington Campus | N8 | House at Pooh Corner | - | - | Exterior, East Side, Near SE Corner | Inside Electrical Cabinet | Electrical Backing Boards | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | SST1 | Main Service Tunnel | G | - | Throughout, Main Service Tunnel | New Gas Pipe Work Flange Joints | Gaskets | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | SST1A | Main Service Tunnel F12 Branch | G | - | Near South End | Stormwater Pipes | Moulded Fibre Cement Pipes | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | P09 | Pool (B4), North, Near NW Corner | Within Wall Recessed Electrical / Comms / Power Point Cabinets x 2 | Electrical Backing Board | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 01 | - | Pool Roof | Roof Covering, Beneath New Rubber Membrane | Suspected Bitumen Membrane | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status and if contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | - | Gymnasium (B5), Exterior, Mid Northern Side | Awning Ceiling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | G | - | Gymnasium (B5), Exterior, Mid Northern Side | Awning Wall Panelling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 01 | 141 | Squash Courts (B7) | Ductwork Flange Joint | Mastic Sealant | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 01 | 1Q4 | Squash Courts (B7), Exterior, Southern Side, Balcony (access off Room 142) | Roof Covering | Bitumen Membrane | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 01 | 1Q4 | Squash Courts (B7), Exterior, Southern Side, Balcony (access off Room 142) | Roof Covering, Beneath New Membrane | Suspected Bitumen Membrane | Suspected Positive | Non-friable | Low | P4 | Maintain in good condition. Confirm status and if contains asbestos, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | B5 | Fitness and Aquatic Centre | 01 | 1Q5 | Squash Courts (B7), Ceiling Space | Ductwork Flange Joints & Joins | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Environs | AS14 | 14 Arthur Street | - | 104 | Bathroom | Beneath caramic floor tiles & cement layer | Fibre Cement Sheeting | Positive | - | - | - | Item removed- refer to Risktech Clearance certificate dated 25/10/2024 | Yes |
KENC | Kensington Environs | AS22 | 22 Arthur St | - | G05 | Kitchen | Beneath caramic floor tiles & cement layer | Fibre Cement Sheeting | Positive | - | - | - | Item removed- refer to Risktech Clearance certificate dated 25/10/2024 | Yes |
KENC | Kensington Environs | AS23 | 23 Arthur St | - | G05A | Pantry | Beneath caramic floor tiles & cement layer | Fibre Cement Sheeting | Positive | - | - | - | Item removed- refer to Risktech Clearance certificate dated 25/10/2024 | Yes |
KENC | Kensington Campus | G27 | AGSM | LG | LG07E | East Side | Window (gap between window framework & glazing) | Mastic Sealant | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | LG | LG40 | Plant Room | Air Conditioning Ductwork Heater Bank | Insulation Board | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | LG | LG73 | Storeroom 3 | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | LG | LGQ3 | Fire Stairwell | Fire Door (tagged 'TDF, 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | LG | LGQ3 | Fire Stairwell | On Top of Brick Wall | Rope Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions as part of a planned control program by a Class A contractor or prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | LG | LGQ4 | Fire Stairwell | Fire Door (tagged 'Robson Doors, 202-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | LG | LGQ4 | Fire Stairwell | On Top of Brick Walls | Rope Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions as part of a planned control program by a Class A contractor or prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | LG | LGQ8 | Fire Stairwell | Fire Door (tagged 'Doorpac, 2023') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | LG | LGQ10 | Fire Stairwell | Fire Door (tagged 'Bismac, 200-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | LG | LGQ13 | Fire Stairwell | On Top of Brick Wall | Rope Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions as part of a planned control program by a Class A contractor or prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | LG | LGQ13 | Fire Stairwell | Fire Door (tagged 'Bismac, 200-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | LG | ELGQ 03 | Electrical Cupboard, Off Room LGQ5 | Floor Covering | Vinyl Floor Tiles | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | LG | - | Throughout, Old Building Section | Window (gap between window framework & glazing) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | G | G61 - G79 | Residential Wing, Accommodation Rooms (several rooms inspected) | Fire Door (tagged 'Bismac, 200-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | G | G74 | Laundry | Fire Door (tagged 'Bismac, 200-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | G | GQ2 | Fire Stairwell | Fire Door (tagged 'Bismac, 2012') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | G | GQ4 | Fire Stairwell | Fire Door (tagged 'TDF, 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | G | GQ4 | Fire Stairwell | On Top of Brick Walls (behind mastic) | Rope Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions as part of a planned control program by a Class A contractor or prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | G | GQ7 | Fire Stairwell | Fire Door (tagged 'Newmac, 199-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | G | GQ9 | Fire Stairwell | Fire Door (tagged 'Bismac, 20--') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | G | GQ11 | Residential Wing, North Entry | Fire Door (tagged 'Bismac, 20--' & 'Wormald, 20--') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | G | GQ11 | Residential Wing, South Entry | Fire Door (tagged 'Robson Doors, 2023') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | G | GQ11 | Electrical Riser Cupboard off Room GQ11, Adjacent Room G61 | Floor Slab, Cable Penetration Seal Covering | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | G | GQ11 | Electrical Riser Cupboard off Room GQ11, Adjacent Room G61 | Floor Slab Penetration (beneath mastic sealant covering) | Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | G | GQ11 | Electrical Riser Cupboard off Room GQ11, Adjacent Room G61 | Surround Cables Above PVC Enclosure | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | G27 | AGSM | G | GQ11 | Electrical Riser Cupboard off Room GQ11, Adjacent Room G61 | Inside Electrical Cabinets | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | G | GQ11 | Electrical Riser Cupboard off Room GQ11, Adjacent Room G61 | Fire Door (tagged 'Bismac, 20--') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | G | GQ12 | Fire Stairwell | Fire Door (tagged 'Bismac, 20--') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | G | GQ12 | Fire Stairwell | On Top of Brick Walls | Rope Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | G | - | Throughout, Old Building Section | Window (gap between window framework & glazing) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | 1 | - | Exterior, NE Corner Open Roof including Raised Area Above Room G07 | Roof Covering | Bituminous Membrane (may be present beneath new membrane layer) | Suspected Positive | Non-friable | Low | P4 | Confirm potential presence of an asbestos membrane layer beneath new membrane layer and if confirmed present, remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | 1 | 110 | Communications Riser Cupboard | Fire Door (tagged 'Robson Doors, 2023') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 1 | 161 - 179 | Residential Wing, Accommodation Rooms (several rooms inspected) | Fire Door (tagged 'Bismac, 200-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 1 | 174 | Storeroom | Floor Covering | Vinyl Floor Tiles | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 1 | 1Q2 | Fire Stairwell | Fire Door (tagged 'TDF, 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 1 | 1Q2 | Fire Stairwell | On Top of Brick Wall | Rope Insulation | Positive (chrysotile) | Friable | Low | P3 | Remove under controlled conditions as part of a planned control program by a Class A contractor or prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | 1 | 1Q3 | Fire Stairwell | Fire Door (tagged 'TDF, 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 1 | 1Q3 | Fire Stairwell | On Top of Brick Walls (behind mastic sealant) | Rope Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions as part of a planned control program by a Class A contractor or prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | 1 | 1Q6 | Fire Stairwell | Fire Doors (tagged 'Robson Doors, 2023' & 'Newmac, 199-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 1 | 1Q8 | Plant Room off Room 1Q8, Adjacent Room 1Q9 (Fire Stairs), North Side | On Top of Brick Walls (behind plastic angles, mastic and/or insulation panelling) | Rope Insulation | Positive (chrysotile) | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions as part of a planned control program by a Class A contractor or prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | 1 | 1Q8 | Plant Room off Room 1Q8, Adjacent Room 1Q9 (Fire Stairs) | On Walls | Adhesive Mastic | Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 1 | 1Q8 | Plant Room off Room 1Q8, Adjacent Room 1Q9 (Fire Stairs) | Fire Door (tagged 'Bismac, 200-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 1 | 1Q9 | Fire Stairwell | Fire Door (tagged 'Bismac, 200-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 1 | 1Q10 | Electrical Riser Cupboard off Room 1Q10, Adjacent Room 161 | Inside Electrical Cabinets | Electrical Backing Board | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 1 | 1Q11 | Fire Stairwell | On Top of Brick Walls | Rope Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions as part of a planned control program by a Class A contractor or prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | 1 | 1Q11 | Fire Stairwell | Fire Door (tagged 'Bismac, 200-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 1 | 1Q11 | Fire Stairwell, Entry to NE Open Roof Area | Fire Door (tagged 'Robson, 2023-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 1 | - | Throughout, Old Building Section | Window (gap between window framework & glazing) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | 2 | 201 | - | Ceiling | Decorative Coating (vermiculite) | Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 2 | 2Q3 | Fire Stairwell | Fire Door (tagged 'Wormald, 20--') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 2 | 2Q3 | Fire Stairwell | On Top of Brick Walls (mostly behind mastic sealant) | Rope Insulation | Positive (chrysotile) | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions as part of a planned control program by a Class A contractor or prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | 2 | 2Q5 | Open Stairs | Fire Door (tagged 'Robson Doors, 2022') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 2 | 2Q6 | North End | Fire Doors (tagged 'Robson Doors, 202-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 2 | 2Q7 | Fire Stairwell | Fire Door (tagged 'Robson Doors, 2022') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 2 | - | Throughout, Old Building Section | Window (gap between window framework & glazing) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | 3 | - | Exterior, Room R321, Fan Room, Access from NE Open Roof Area (Adjacent Fire Stairwell 1Q11) | Fire Door (tagged 'Masterbilt Industries', no date) | Core Insulation | Positive (chrysotile & amosite) | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions as part of a planned control program by a Class A contractor or prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | 3 | 321 | Communications Riser Cupboard (Room CQ301) | Fire Door (no tag) | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 3 | 3Q3 | Fire Stairwell | Fire Door (tagged 'TDF, 2017') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 3 | 3Q3 | Fire Stairwell | On Top of Brick Walls (wall sections behind mastic sealant) | Rope Insulation | Assumed Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions as part of a planned control program by a Class A contractor or prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | 3 | 3Q6 | North End | Fire Doors (tagged 'Newmac, 199-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 3 | 3Q7 | Fire Stairwell | Fire Door (tagged 'Newmac, 199-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | G27 | AGSM | 3 | - | Throughout, Old Building Section | Window (gap between window framework & glazing) | Mastic Sealant | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | G27 | AGSM | 4 | 4Q3 | Fire Stairwell | Fire Door (tagged 'Robson Doors, 2023') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C27 | Wallace Wurth | LG | - | Throughout, Fire Stairwells, Fire Service Rooms off Room LGQ29, Room LGQ02 & LGQ33 | Fire Doors (tagged 'Titan, 201_' & Ikon, 200-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C27 | Wallace Wurth | G | - | Throughout, Fire Stairwells & Room GQ01 | Fire Doors (tagged 'Titan, 201_' & Robson Doors, 202-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C27 | Wallace Wurth | 1 | - | Throughout, Fire Stairwells & Room 1Q01 | Fire Doors (tagged 'Titan, 201_' & Robson Doors, 202-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C27 | Wallace Wurth | 2 | - | Throughout, Fire Stairwells | Fire Doors (tagged 'Titan, 201_' & Cecon, 199-') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C27 | Wallace Wurth | 3 | - | Throughout, Fire Stairwells & Room 3Q01 | Fire Doors (tagged 'Titan, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C27 | Wallace Wurth | 4 | - | Throughout, Fire Stairwells & Room 4Q01 | Fire Doors (tagged 'Titan, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C27 | Wallace Wurth | 5 | - | Throughout, Fire Stairwells & Room 5Q01 & 5Q16 | Fire Doors (tagged 'Titan, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C27 | Wallace Wurth | 6 | - | Throughout, Fire Stairwells & Room 6Q01, 6Q17 & 6Q22 | Fire Doors (tagged 'Titan, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C27 | Wallace Wurth | 7 | - | Throughout, Fire Stairwells & Plant Rooms | Fire Doors (tagged 'Titan, 201_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | G | G2A | - | Floor Covering (beneath hessian backed vinyl sheeting) | Vinyl Floor Tiles | Removed - Positive (chrysotile) | - | - | - | Item Removed: Refer to SSS Clearance Certificate dated 12 September 2022. | Yes |
KENC | Kensington Campus | F20 | Goodsell | G | G2A | - | On Soffit | Textured Plaster Coating | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | G | G11 | North Side, Below Window (behind plasterboard wall) | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G14 | - | Floor Covering (beneath hessian backed vinyl sheeting) | Vinyl Floor Tiles | Removed - Positive (chrysotile) | - | - | - | Item Removed: Refer to SSS Clearance Certificate dated 12 September 2022. | Yes |
KENC | Kensington Campus | F20 | Goodsell | G | G17 | - | Floor Covering (beneath carpet tiles) | Vinyl Floor Tiles | Removed - Positive (chrysotile) | - | - | - | Item Removed: Refer to SSS Clearance Certificate dated 12 September 2022. | Yes |
KENC | Kensington Campus | F20 | Goodsell | G | G21 | North Side, Below Window (behind plasterboard wall) | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G22 | - | On Soffit | Decorative Coating (vermiculite) | Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | G | G23 | South Side, Below Window (behind plasterboard wall) | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G24 | South Side, Below Window (behind plasterboard wall) | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G25 | South Side, Below Window (behind plasterboard wall) | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G26 | South Side, Below Window (behind plasterboard wall) | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G27 | Eastern Section, North & South Sides, Below Windows | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G28 | - | Floor Covering | Vinyl Floor Tiles & Amber Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | F20 | Goodsell | G | G30 | - | Floor Covering (beneath carpet tiles) | Vinyl Floor Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G31 | - | Floor Covering (beneath carpet tiles) | Vinyl Floor Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G31A | - | Floor Covering (beneath carpet tiles) | Vinyl Floor Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G32 | - | Floor Covering (beneath carpet tiles) | Vinyl Floor Tiles | Positive (chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G33 | - | Floor Covering (beneath carpet tiles) | Vinyl Floor Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G34 | - | Floor Covering (beneath carpet tiles) | Vinyl Floor Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G34 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | G35 | - | Floor Covering (beneath carpet tiles) | Vinyl Floor Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | G | GQ7 | North Side, Below Window | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 1 | 103A | South Side, Below Window (behind plasterboard wall) Note: Previously Room 125C | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 1 | 105A | South Side, Below Windows (behind plasterboard wall) Note: Previously Room 133 | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 1 | 122 | North Side, Below Window (behind plasterboard wall) Note: Previously Room 106 | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 1 | 123 | North Side, Below Window (behind plasterboard wall) Note: Previously Room 104 | Vertical Expansion Wall Joint | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 1 | 126 | South Side, Below Windows (behind plasterboard walls) Note: Previously Room 103, 105, 107, 109, 111, 112, 113 & 115 | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 1 | 1Q10 | East Side, Below Windows (behind plasterboard wall) | Vertical Expansion Wall Joints | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 1 | 1Q13 | Electrical Cupboard | - | Electrical Backing Board | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | F20 | Goodsell | 2 | 2Q3A | Plumbing Duct off Room 238 Toilets | Pipework | Insulation | Removed - Positive | - | - | - | Item Removed: Refer to NAA Clearance Certificate dated 3 September 2007 (Ref: 59392). | Yes |
KENC | Kensington Campus | F20 | Goodsell | 3 | 3Q1A | Fire Stairs, West | Fire Door (tagged 'Inglis, Asbestos Free Fire Door, 1990') | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | F20 | Goodsell | 3 | 3Q1A | Fire Stairs, North | Fire Door (not tag) | Insulation Core | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | B21 | Repository | G | G01 | Perimeter, South Side, Near SE Corner of Walls, Top of Walls | Expansion Joints | Bituminous Coating | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | B | - | Various Areas | Ductwork Flange Joints (old ductwork only) | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | LG | Exterior, West Wing, North Side, Outside Entry, Beneath Concrete Pavers | Ground Covering | Bituminous Membrane | Negative | - | - | - | - | N/A | |
KENC | Kensington Campus | C22 | Chancellery | LG | Exterior, West Wing, South Side, Beneath Concrete Pavers | Floor Covering | Bituminous Membrane | Negative | - | - | - | - | N/A | |
KENC | Kensington Campus | C22 | Chancellery | LG | LGQ2 | Stairwell | Fire Door (tagged 'Cecon, 199_') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | C22 | Chancellery | LG | LGQ8 | Adjacent LG23, Risers (adjacent Electrical Switchboard Cupboard) | Stored Conduits & Debris | Moulded Fibre Cement Pipe | Assumed Positive | Non-friable | Low | P4 | Restrict access to the riser in the interim. Remove under controlled conditions by a Class A/B contractor within a planned control program or prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | G | GQ3 | Stairwell | Gap Between Internal Window Framework & Glass Pane | Mastic Sealant | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | 1 | - | North Wing | Floor Covering | Vinyl Floor Tiles (beige colour) & Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | 1 | M1Q03 | Plumbing Duct off Room 146 Toilets | Pipe | Insulation | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | 2 | 203B | - | Floor Covering | Vinyl Floor Tiles (brown colour) & Adhesive | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | C22 | Chancellery | 2 | 246 | - | Air Conditioning Ductwork, Flange Joint | Mastic Sealant | Negative | - | - | - | N/A | |
KENC | Kensington Campus | C22 | Chancellery | 2 | 246 | Ceiling Space | Plasterboard Ceiling (above new ceiling) | Decorative Vermiculite Plaster Coating | Negative | - | - | - | N/A | |
KENC | Kensington Campus | C22 | Chancellery | 2 | 246 | Ceiling Space | On Top of New Ceiling - Debris | Decorative Vermiculite Plaster | Negative | - | - | - | N/A | |
KENC | Kensington Campus | C22 | Chancellery | 2 | 2Q14 | Ceiling Space | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 2 | 2Q15 | Ceiling Space | Ductwork Flange Joins | Sealant Mastic | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 2 | 2Q15 | Toilet | Plasterboard Ceiling | Decorative Vermiculite Plaster Coating | Negative | - | - | - | N/A | |
KENC | Kensington Campus | C22 | Chancellery | 2 | - | Exterior Throughout | Eaves | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | C22 | Chancellery | 3 | 302A | West Side | Fire Door (hatch-like door) | Core Insulation | Removed - Positive | - | - | - | Item Removed: Refer to RiskTech Asbestos Clearance Certificate dated 21 October 2017. | Yes |
MISC | Tarban Creek | TC1 | Tarban Creek Boat Shed | G | G03A | Store | Ceiling | Fibre Cement Sheeting | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
MISC | Tarban Creek | TC1 | Tarban Creek Boat Shed | G | GQ2 | - | Shower & Toilet Cubicle Partitions | Compressed Fibre Cement Sheeting | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | B | BQ03 | Communications Riser Cupboard, On Floor | Packing Material | Insulation Debris | Removed - Positive (Chrysotile & Amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 2 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | B | BQ03 | Communications Riser Cupboard, Inside Pipe Conduits (~30mm diameter x 2 pipes) | Packing Material | Insulation | Removed - Positive (Amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 2 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | G | GQ03 | Communications Riser Cupboard, Inside Pipe Conduits (~30mm diameter x 6 pipes) | Packing Material | Insulation | Removed - Positive (Amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 12 &16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | G | GQ03 | Communications Riser Cupboard, On Floor & General Surfaces | Packing Material | Insulation Debris | Removed - Positive (Amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 12 &16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | G | GQ03 | Hydraulic Riser Cupboard, West Wall Pipe Penetration | Packing Material | Insulation | Removed - Positive (Amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 12 &16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q05 | Electrical Cupboard | Door Lining | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q08 | Cleaners Cupboard | Floor Covering | Vinyl Floor Tiles | Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 2 | 2Q08 | Cleaners Cupboard | Floor Covering | Adhesive (attached to vinyl tiles) | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 2 | 218 | Cleaners Room, On Top of Blockwork North Wall (western section) | Packing Material | Insulation | Removed - Positive (Chrysotile & Amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 2 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 2 | 219A | Riser West of Room 219A, On Top of Blockwork South Wall and Debris on Floor & Residue on Wall | Packing Material | Insulation | Removed - Assumed Positive | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 2 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 3 | 3Q02 | Communications Riser Cupboard, Inside Pipe Conduits (~30mm diameter x 6 pipes) | Packing Material | Insulation | Removed - Assumed Positive | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 8 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 3 | 3Q02 | Communications Riser Cupboard, South Wall Penetrations | Packing Material | Insulation | Removed - Assumed Positive | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 8 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 3 | 3Q02 | Communications Riser Cupboard, On Floor | Packing Material | Insulation Debris | Removed - Assumed Positive | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 8 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 3 | 3Q02 | Fire Hose Reel Riser Cupboard, Vertical Wall Expansion Joint | Packing Material | Insulation | Removed - Assumed Positive | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 8 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 3 | 302 | Under Carpet | Floor Covering | Vinyl Floor Tiles | Assumed Positive | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 302 | - | Floor Covering | Adhesive (attached to vinyl tiles) | Assumed Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 3 | 318A | Riser West of Room 318A, On Top of Blockwork South Wall | Packing Material | Insulation Debris | Removed - Positive (Chrysotile & Amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 8 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 4 | 4Q02 | Communications Riser Cupboard, Inside Pipe Conduits (~30mm diameter x 6 pipes) | Packing Material (suspected beneath mastic) | Insulation | Suspected Positive | Friable | Low | P3 | Confirm status and if confirmed to contain asbestos, removed under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 4 | 4Q02 | Communications Riser Cupboard, On Top of Blockwork South & West Walls & Vertical Wall Expansion Joint | Packing Material | Insulation | Removed -Positive (Amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 6 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 4 | 4Q02 | Communications Riser Cupboard, On Floor | Packing Material | Insulation Debris | Removed - Assumed Positive | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 6 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 4 | 415A | Riser West of Room 415A, On Top of Blockwork North Wall | Packing Material | Insulation Debris | Removed -Assumed Positive | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 6 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 5 | 5Q01 | Communications Riser Cupboard, South Wall Penetration | Packing Material | Insulation | Removed - Assumed Positive | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 6 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 5 | 5Q01 | Communications Riser Cupboard, Inside Pipe Conduits (~30mm diameter x 6 pipes) | Packing Material | Insulation | Removed - Assumed Positive | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 6 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 5 | 513A | Riser West of Room 513A, On Top of Blockwork South Wall | Packing Material | Insulation | Removed -Assumed Positive | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 6 & 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 7 | 7Q02 | Corridor, North Side, Above Entry to Room 702 (Plant Room), On Top of Blockwork Walls | Packing Material (inside bulkhead enclosure) | Insulation | Suspected Positive | Friable | Low | P3 | Maintain in good condition. Remove under controlled conditions by a Class A contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 7 | 701 | Observation Room, On Top of South & East Blockwork Walls | Packing Material | Insulation | Removed - Assumed Positive | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 7 | 701 | Observation Room, East & South Sides, Pipe Wall Penetrations | Packing Material | Insulation | Removed - Assumed Positive | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 7 | 702 | Entrance | Fire Door (Tagged 'Bismac, 2004') | Core Insulation | Suspected Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 7 | 702 | Plant Room, Adjacent Entrance | Air Conditioning Ductwork Heater Bank | Internal Insulation | Suspected Negative | - | - | - | Note: Synthetic mineral fibre (SMF) insulation sandwiched between an outer metal sheet layer & an inner perforated metal sheet layer (via a 15mm drilled hole into duct). No insulation board observed lining interior face of the duct. | No |
KENC | Kensington Campus | K17 | Building K17 | 7 | 702 | Plant Room, East | Water Tank Joints | Mastic Sealant | Negative | - | - | - | - | No |
KENC | Kensington Campus | K17 | Building K17 | 7 | 702 | - | Ductwork Joints | Mastic Sealant | Positive (Chrysotile) | Non-friable | Low | P4 | Maintain in good condition. Remove under controlled conditions by a Class A/B contractor prior to demolition or refurbishment. | No |
KENC | Kensington Campus | K17 | Building K17 | 7 | 702 | Plant Room, On Top of Blockwork North & East Walls | Packing Material | Insulation | Removed - Positive (Chrysotile) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 7 | 702 | Plant Room, North Wall & Floor Slab Penetrations | Packing Material | Insulation | Removed - Positive (Amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 7 | 702 | Plant Room, Floor Slab Expansion Joint in Floor Slab Abutting North Wall | Packing Material | Insulation | Removed - Positive (Amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 7 | 702 | Plant Room, West Side, Immediately North of Boiler Unit, Floor Slab Pipe Penetration | Packing Material | Insulation Debris | Removed - Positive (Amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 7 | 702 | Plant Room, On Floor Near Boiler Unit & On Top of Duct Above North Entry | Packing Material | Insulation Debris | Removed - Positive (Amosite) | - | - | - | Item Removed. Refer to RiskTech Compliance Asbestos Clearance Certificate dated 16 June 2021. | Yes |
KENC | Kensington Campus | K17 | Building K17 | 7 | 702 | Plant Room, South, Below Non-Potable Water Tank | Floor Covering | Membrane Material | Negative | - | - | - | - | N/A |
KENC | Kensington Campus | K17 | Building K17 | 7 | 702 | Plant Room, South, Boilers | Flue & Motor | Gasket | Negative | - | - | - | - | N/A |
KENE | Kensington Environs | BS34 | 34 to 36 Botany Street | G | G21A | Toilet Block Ceiling | Fibre Cement Sheeting | Compressed Fibre Cement Sheeting | Positive - Removed | - | - | - | Item Removed- Refer to Risktech Clearance Certificate dated 04/11/2024 | Yes |
KENC | Kensington Environs | AS14 | 14 Arthur Street | G | - | Exterior, East, Entrance | Awning Ceiling | Plaster Material | Suspected Negative | - | - | - | - | No |
KENC | Kensington Environs | AS14 | 14 Arthur Street | G | - | Exterior, East Side | Timber Window Mastic | Mastic | Negative | - | - | - | - | N/A |
KENC | Kensington Environs | AS14 | 14 Arthur Street | G | - | Sub-Floor Space | Packing Strips, Floor Footings & Between Timber Flooring & Joists | Fibre Cement Sheeting | Assumed Positive | Non-friable | Low | P4 | Maintain item in good condition. Remove by a Class A/B licensed asbestos contractor prior to refurbishment/demolition. | No |
KENC | Kensington Environs | AS14 | 14 Arthur Street | G | - | Internal, South Bathroom | Wall Infill Panelling | Fibre Cement Sheeting | Negative | - | - | - | - | N/A |
FSSL | Smith Lake Field Station | SL1 | Smith Lake Laboratory | G | UGQ2 | Exterior, South | Awning Ceiling | Masonite (non-asbestos material) | Suspected Negative | - | - | - | - | No |
FSSL | Smith Lake Field Station | SL1 | Smith Lake Laboratory | G | - | Exterior, North, East & West | Eaves | Masonite (non-asbestos material) | Suspected Negative | - | - | - | - | No |